AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Similar documents
AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Add-on Residual Current Protection PBSM MW

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Disconnect Switches. Safe Switching and Disconnecting

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Defender B Board. Make The Switch

Residual Current Devices drcm Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

DSE201, DSE201 M Compact design with enhanced protection

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Combined RCD/MCB Devices FRBmM, 1+N-pole

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

1492-SP Supplementary Protectors

UL 489 DIN Rail Miniature Circuit Breakers

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

UL 489 DIN Rail Miniature Circuit Breakers

NEW Titan II A & B Distribution Boards

TP&N DISTRIBUTION BOARD TYPE B RANGE

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Protect Circuit Protection

For Sales and Support call KMParts.com (866)

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Dorman Smith Loadbank 125 MCCB Panel Boards

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

Circuit Breakers Type CTI 25M, CTI 45MB

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

MOTOR PROTECTION CIRCUIT BREAKERS

Allen-Bradley 1492-RCDA4A40

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Motor protection circuit breakers

Distribution Systems ALPHA. Answers for infrastructure and cities. Edition Catalog LV 51

Electronic timer CT-ARS.11

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

References. References. Rating (A) Référence

Surge Protection Devices Ex9UE2

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Electronic timer CT-ERD.12

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Table of Contents Protective Devices / Components

Electronic timer CT-AHD.22

the Santon FCS-type switch Disconnect Superior Switch Solutions

Datasheet - SRB 402EM-24V

RB60 RANGE. Miniature circuit breakers

Horizontal distribution busbar HX 3 80/125 A plug-in

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Pan assemblies and installation accessories

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

XL 4000 metal free-standing enclosures and cable compartments

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

US Catalog July 2016 SMISSLINE TP

IT power distribution Power distribution units (PDU) Basic. Versions available:

Electronic timer CT-ERS.21

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

CS8 Industrial Control Relays

Jtec 10kA Miniature Circuit Breaker

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

3RV1 Circuit-Breakers

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

RATINGS AND SPECIFICATIONS

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

SIRCO Load break switches for power distribution from 125 to 5000 A

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

B60 Domestic Voltage Optimisation Unit

Power Supply HARTING pcon

Thermal-Magnetic Circuit Breaker 4220-T...

ic60n RCBO 30 ma IEC , IEC , AS/NZS

Product Guide. UL 489 DIN rail miniature circuit breakers

Safety switches for hinged doors

OsiSwitch Limit Switches Innovation through modularity

MINI-PS AC/10-15DC/8

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Transcription:

www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer Units XPole Miniature Circuit Breakers, RCDs and RCBOs A + B Type Distribution Boards Mini Panel Boards Panel Boards AThink future. Switch to green.

Mini Panel Board The Mini Panel Board is a highly innovative new board featuring a pan assembly rated to 400A. It offers a cost effective and compact alternative to a traditional, assembled panel board, and is well suited to commercial and industrial applications. As part of Moeller s comprehensive range of consumer units, A + B type boards and panel boards, the Mini Panel Board has been developed to meet the needs of UK specifiers, electrical contractors and distributors to the latest British, European and international standards. Keyhole fixings for ease of installation Fully reversible door with document holder (lockable option available) Sturdy 1.25mm gauge enclosure Removable pan assembly rated to 400A Unique miniature circuit breaker for outgoing ways rated from 20A to 125A, at 25kA Accessible earth and neutral bars for ease of wiring Incoming MCCB Main Switch 20A to 400A Neutral disconnect Main busbar shroud All terminals and fixing screws use just one screwdriver a No2 Pozi screwdriver Available with spreader box to meet larger cable requirements Modular service box to house automation, control devices and metering packs

Mini Panel Boards Three Phase with 400A Busbar Number of Outgoing Ways Part Number Height Width Depth 4 FG-LH-04 960 610 200 8 FG-LH-08 960 610 200 12 FG-LH-12 1290 610 200 16 FG-LH-16 1290 610 200 Incoming Devices 3 Pole Rated Current (A) Moulded Case Circuit Breaker Switch Disconnector 160 PMC2-160/3 PSC2-160/3 200 PMC2-200/3 PSC2-200/3 250 PMC2-250/3 PSC2-250/3 300 PMC3-300/3 PSC3-300/3 400 PMC3-400/3 PSC3-400/3 Note: PMC3/PSC3 must be used in conjunction with FG-LH/INC400 (below) Incomer Enclosure supplied complete with shrouds and copper links For use with Part Number Height Width Depth PMC3- * or PSC3- * FG-LH/INC400 340 610 200 Outgoing Devices Miniature Circuit Breakers PLHT Thermomagnetic release, switching capacity up to 25kA at 415 50/60Hz Poles Rated Current (A) B Type C Type D Type 20 PLHT-B20 PLHT-C20 PLHT-D20 25 PLHT-B25 PLHT-C25 PLHT-D25 32 PLHT-B32 PLHT-C32 PLHT-D32 40 PLHT-B40 PLHT-C40 PLHT-D40 1-Pole 3-Pole 50 PLHT-B50 PLHT-C50 PLHT-D50 63 PLHT-B63 PLHT-C63 PLHT-D63 80 PLHT-B80 PLHT-C80 PLHT-D80 100 PLHT-B100 PLHT-C100 PLHT-D100 125 PLHT-B125 PLHT-C125 20 PLHT-B20/3 PLHT-C20/3 PLHT-D20/3 25 PLHT-B25/3 PLHT-C25/3 PLHT-D25/3 32 PLHT-B32/3 PLHT-C32/3 PLHT-D32/3 40 PLHT-B40/3 PLHT-C40/3 PLHT-D40/3 50 PLHT-B50/3 PLHT-C50/3 PLHT-D50/3 63 PLHT-B63/3 PLHT-C63/3 PLHT-D63/3 80 PLHT-B80/3 PLHT-C80/3 PLHT-D80/3 100 PLHT-B100/3 PLHT-C100/3 PLHT-D100/3 125 PLHT-B125/3 PLHT-C125/3

Accessories Description / Used for Part Number Glazed Door for FG-LH-04,08 for FG-LH-12,16 FG-LH-GD-4/8 FG-LH-GD-12/16 Spreader Boxes Dimensions height width depth for FG-LH- * Mini Panel Board FG-LH-EX 340 610 130 Modular Service Box Dimensions height width depth 19" Modular DIN rail FG-LH-SM30 340 610 130 Terminal Extension Adapters to 35mm 2 (pack of 10) to 50mm 2 (pack of 10) FG-KLA/ZB-35 FG-KLA/ZB-50 Accessories for FG-LH- * Lock and key Busbar tag shrouds (pack of 20) Blanking strips (6 modules) FG-DOORLOCK FG-BTS AP-45-W Cable Lugs required as standard Cable size (mm 2 ) For use with Poles Part Number 95 PMC/PSC2 3 KS95-NZM7 120 PMC/PSC2 3 KS120-NZM7 150 PMC/PSC2 3 KS150-NZM7 185 PMC/PSC2 3 NZM2-XKS185 185 PMC/PSC3 3 NZM3-XKS185 Note: Order 3 off for 3-pole. 240 PMC/PSC3 3 NZM3-XKS240 Box Terminals copper cable, stranded For use with Poles Terminal Capacity I n (A) Part Number PMC/PSC2 3 1 x (4 16) + 2 x (4 16) 160 NZM2-160-XKC PMC/PSC2 3 1 x (25 185) + 2 x (25 70) 250 NZM2-250-XKC PMC/PSC3 3 1 x (35 240) + 2 x (16 120) 500 NZM3-XKC

Technical Data Mini Panel Board Three Phase with 400A Busbar General Incoming Options 3 Pole MCCB, 3 Pole Switch Disconnector Applicable Standard BS EN 60439-1: 1994 Technical Data Electrical Busbar Nominal Rating 400A Busbar Short Circuit withstand 40kA for 0.5s, 25kA for 1s Rated Voltage U e 415V AC 50/60Hz Maximum Incomer Rating 400A Maximum Outgoing Device 125A Safety Class I Electromagnetic compatibility Environment 1 Maximum amount of heat to be dissipated* * Calculated regarding IEC 890 FG-LH-04 148W FG-LH-08 148W FG-LH-12 123W FG-LH-16 123W Technical Data Mechanical Ingress Protection IP40 when the door is closed, IP30 when the door is open, IP2X without cover plate Paint Finish RAL 7035 textured, epoxy powder coated Limits of Operation 40 C ambient 50% RH Enclosure Steel Gauge 1.5mm Gland Plate 1 blank and 1 with knockouts Maximum Cable Capacity Neutral Bar 25mm 2 * Earth Bar 25mm 2 * * 35mm 2 with adaptor (FG-KLA/ZB-35), 50mm 2 with adaptor (FG-KLA/ZB-50) Main Earth Termination 150mm 2 Main Neutral Termination 150mm 2 Material Plastic Parts Support for busbar Noryl SE1 Cover for busbar PVC grey Cover for neutral wire PVC transparent Hinge roller Polyamide Rotary lever lock Polyamide Metal Parts Console for devices ST 37 1.00mm galvanized Casing ST 37 1.25mm Lid ST 37 1.25mm Door ST 37 1.25mm Mounting plate ST 37 1.5mm Busbar copper E-Cu 58 Neutral and earth busbar MS 58 Screws Galvanized and passivated Environmental Conditions Ambient temperature -5 to +40 C Average ambient temperature over 24 hours 35 C Relative air humidity 50% at 40 C

Technical Data Moulded Case Circuit Breakers PMC General Standards IEC/EN 60947, VDE 0660 Protection against direct contact Finger and back-of-hand proof to VDE 0160 part 100 Climatic proofing Damp heat, constant, to IEC 60068-2-78, Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature -25 C / +70 C Mechanical shock resistance 20g (half-sinusoidal shock 20ms) Safe isolation to VDE 0106 part 101 & 101/A1 Between auxiliary contacts and main circuits: 500V AC Between the auxiliary contacts: 300V AC Direction of incoming supply As required PMC2- PMC3- Rated impulse withstand voltage Main contacts U imp (V) 8000 8000 Auxiliary contacts U imp (V) 6000 6000 Rated operational voltage U e (VAC) 690 690 Rated insulation voltage U i (V) 1000 1000 Overvoltage category / pollution degree III/3 III/3 Terminal capacity mm 2 1 x (25 185) 2 x (25 70) 1 x (25 240) 2 x (25 240) Switching capacity Rated short-circuit making capacity 240V AC I cm (ka) 63 187 400/415V AC I cm (ka) 53 105 Rated short-circuit breaking capacity I cu to IEC/EN 60947 test cycle O-t-CO I cs to IEC/EN 60947 test cycle O-t-CO-t-CO 240V AC I cu (ka) 30 85 400/415V AC I cu (ka) 25 50 240V AC I cs (ka) 15 42.5 400/415V AC I cs (ka) 12.5 25 Utilisation category A A Rated making and breaking capacity Rated operational current AC-1 240V AC I e (A) 250 630 400/415V AC I e (A) 250 630 Lifespan, mechanical operations 10000 7500 (of which max. 20% trip by shunt/undervoltage release) Maximum operating frequency S/h 30 30 Lifespan, electrical AC-1 240V AC operations 5000 2500 400/415V AC operations 5000 2500 Current heat loss per pole at I u W 19 40 Overload releases Temperature compensation for PMC2 to IEC/EN 60947, thermomagnetic %/K 0.3 VDE 0660, part 101. Residual error in range -25 C/+70 C (ref. temperature 40 C) electronic %/K 0.3 0.3 Total opening delay on short-circuit ms < 10 < 10

Technical Data Switch Disconnectors PSC PSC2- PSC3- Rated impulse withstand voltage Main contacts U imp (V) 8000 8000 Auxiliary contacts U imp (V) 6000 6000 Rated operational voltage U e (VAC) 525 525 Overvoltage category / pollution degree III/3 III/3 Terminal capacity mm 2 1 x (25 185) 2 x (25 70) 1 x (25 240) 2 x (25 240) Switching capacity Rated short-circuit making capacity I cm (ka) 5.5 25 Rated short-time withstand current t = 0.3s I cw (ka) 3.5 12 t = 1s I cw (ka) 3.5 12 Rated conditional short-circuit current with back-up fuse A gg/gl 250 630 240V AC ka 100 100 400/415V AC ka 100 100 Rated making and breaking capacity Rated operational current AC-22/23A 240V AC I e (A) 250 630 400/415V AC I e (A) 250 630 Lifespan, mechanical operations 10000 7500 Maximum operating frequency S/h 30 30 Lifespan, electrical AC-1 240V AC operations 5000 2500 400/415V AC operations 5000 2500 Current heat loss per pole at I u W 16 40 Miniature Circuit Breaker PLHT Electrical Design according to EN 60947-2 Current test marks as printed onto the device Rated voltage AC 230/400V DC 60V (per pole) Ultimate short circuit breaking capacity according to IEC/EN 60947-2 Characteristics B, C I n = 20 63A 25kA I n = 80 100A 20kA I n = 125A 15kA Characteristic D I n = 63A 25kA I n = 80A 20kA I n = 100A 15kA Characteristic in accordance with characteristics B, C, D Back-up fuse max. 200 A gl Rated insulation voltage 440V Peak withstand voltage U imp 4kV Selectivity class in accordance with class 3 Endurance 20,000 operating cycles Mechanical Frame size 45mm Device height 90mm Device width 27mm (1.5MU) per pole Mounting quick fastening with two lock-in positions on DIN rail EN 50022 Degree of protection, built-in IP40 Upper and lower terminals lift terminals Terminal protection finger and hand touch safe, BGV A3, ÖVE-EN 6 Terminal capacity 2.5 50 mm 2

Moeller Electric Limited PO Box 35, Gatehouse Close Aylesbury Buckinghamshire HP19 8DH www.moeller.co.uk Direct sales ordering tel 01296 397400 fax 01296 392413 email sales@moeller.co.uk Technical support tel 01296 310323 fax 01296 392413 email support@moeller.co.uk Moeller Electric Limited 12/05 W0200-268GB Article number: 641151 AThink future. Switch to green.