Magnetic Resonance Elastography (MRE) of Liver Disease

Similar documents
QIBA Profile: Magnetic Resonance Elastography of the Liver

J. A. Smith Process Modeling and Measurement Coming Incorporated Coming, NY 14831

New Technology Allows Multiple Image Contrasts in a Single Scan

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

8/11/2009. Common Areas of Motion Problem. Motion Compensation Techniques and Applications. Type of Motion. What s your problem

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.

MRI Physics II: Gradients, Imaging

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

Applications Guide for Interleaved

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

Supplementary methods

Motion Artifacts and Suppression in MRI At a Glance

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

FINDING THE TRUE EDGE IN CTA

A Virtual MR Scanner for Education

Automated segmentation methods for liver analysis in oncology applications

Semi-Automatic Segmentation of the Patellar Cartilage in MRI

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

7D Cardiac Flow MRI: Techniques & Automation of Reconstruction

Conference Biomedical Engineering

Automatic Determination of Arterial Input Function for Dynamic Contrast Enhanced MRI in Tumor Assessment

Parallel Imaging. Marcin.

ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma

M R I Physics Course

Computer-Aided Diagnosis in Abdominal and Cardiac Radiology Using Neural Networks

Lecture 6: Medical imaging and image-guided interventions

Supplementary Figure 1

Computation of the Effect of Implants on Tongue Motion. American Association of Otolaryngology-Head and Neck Surgery, Sept 19, 2007 Washington, DC

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

Breast MRI Accreditation Program Clinical Image Quality Guide

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Image Acquisition Systems

GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

Acknowledgments and financial disclosure

surface Image reconstruction: 2D Fourier Transform

High dynamic range magnetic resonance flow imaging in the abdomen

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Imaging protocols for navigated procedures

MR Elastography of the Liver: Defining Thresholds for Detecting Viscoelastic Changes 1

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

Supplementary Information

Use of MRI in Radiotherapy: Technical Consideration

Journal of Visualized Experiments

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Digital Image Processing

MR Advance Techniques. Vascular Imaging. Class III

연구용유방초음파질관리 원광대학병원김혜원

TUMOR DETECTION IN MRI IMAGES

QIBA PET Amyloid BC March 11, Agenda

Technical Publications

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

COMPREHENSIVE QUALITY CONTROL OF NMR TOMOGRAPHY USING 3D PRINTED PHANTOM

Ch. 4 Physical Principles of CT

Computer Aided Diagnosis Based on Medical Image Processing and Artificial Intelligence Methods

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Technical Publications

CHAPTER 3 RETINAL OPTIC DISC SEGMENTATION

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Lucy Phantom MR Grid Evaluation

Segmenting Lesions in Multiple Sclerosis Patients James Chen, Jason Su

Development and Optimization of Fourdimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy

TEMPLATE-BASED AUTOMATIC SEGMENTATION OF MASSETER USING PRIOR KNOWLEDGE

Global Thresholding Techniques to Classify Dead Cells in Diffusion Weighted Magnetic Resonant Images

Respiratory Motion Estimation using a 3D Diaphragm Model

Magnetic Resonance Angiography

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Quantitative IntraVascular UltraSound (QCU)

ThE ultimate, INTuITIVE Mr INTErFAcE

A fast breast nonlinear elastography reconstruction technique using the Veronda-Westman model

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software

RADIOMICS: potential role in the clinics and challenges

TOF-MRA Using Multi-Oblique-Stack Acquisition (MOSA)

High performance MRI simulations of motion on multi-gpu systems

Motion Artifact Suppression in MRI Using k-space Overlap Processing ABSTRACT

Skåne University Hospital Lund, Lund, Sweden 2 Deparment of Numerical Analysis, Centre for Mathematical Sciences, Lund University, Lund, Sweden

Whole Body MRI Intensity Standardization

Deep Learning for Fast and Spatially- Constrained Tissue Quantification from Highly-Undersampled Data in Magnetic Resonance Fingerprinting (MRF)

Technical Publications

Artefacts in body and breast MRI: lessons learned from second reading

Artefacts in body and breast MRI: lessons learned from second reading

Computational Medical Imaging Analysis

Resona 7. New Waves in Ultrasound Innovation. Premium Ultrasound System

Functional MRI in Clinical Research and Practice Preprocessing

4D Magnetic Resonance Analysis. MR 4D Flow. Visualization and Quantification of Aortic Blood Flow

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

Redundancy Encoding for Fast Dynamic MR Imaging using Structured Sparsity

Compressed Sensing for Rapid MR Imaging

Material Properties Estimation of Layered Soft Tissue Based on MR Observation and Iterative FE Simulation

SPM8 for Basic and Clinical Investigators. Preprocessing

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Volumetric Analysis of the Heart from Tagged-MRI. Introduction & Background

XI Signal-to-Noise (SNR)

Unaliasing by Fourier-Encoding the Overlaps Using the Temporal Dimension (UNFOLD), Applied to Cardiac Imaging and fmri

Transcription:

Magnetic Resonance Elastography (MRE) of Liver Disease Authored by: Jennifer Dolan Fox, PhD VirtualScopics Inc. jennifer_fox@virtualscopics.com 1-585-249-6231 1. Overview of MRE Imaging MRE is a magnetic resonance imaging (MRI)-based technology for non-invasively characterizing the biomechanical properties of tissues and may serve as a potential surrogate to invasive liver biopsies for diagnosing and staging liver fibrosis. MRE can be used to quantitatively image the direct consequence of liver fibrosis- increased stiffness of the hepatic tissue. MRE is performed following three basic steps: 1) using a vibration source to generate low frequency mechanical waves in tissue, 2) imaging the propagating waves using a phase contrast MRI technique and then 3) processing the wave information to generate quantitative images (elastograms) showing the mechanical properties, i.e. stiffness, of the tissue. 2. Liver MRE Acquisition 2.1 Generating Mechanical Waves To implement MRE imaging, a subject lies on the scanner table in the supine position and a disc-shaped acoustic passive driver is placed on the abdomen as shown in Figure 1 [1,2]. The driver is placed against the right anterior chest wall overlaying the right lobe of the liver with its center at the level of the xiphisternum as shown in Figure 2. The passive driver is then secured in place with an elastic belt. The passive driver is connected, via flexible polyvinylchloride (PVC) tubing, to an acoustic speaker system located outside of the scanner room. The acoustic speaker produces vibrations of approximately 60 Hz, which are transmitted to the passive driver via the tube. Commercially available MRE systems typically contain the necessary hardware (drivers and tubing) as well as specialized software for acquisition and processing.

Figure 1. Diagram of the MRE driver system setup for a clinical whole-body MRI scanner. 1: patient table, 2: patient, 3: passive MRE driver, 4: MRI scanner bore, 5: flexible PVC tube, 6: acoustic speaker. Figure taken from Chen et al. [1]. Figure 2. Diagram demonstrating how the mechanical driver is positioned over the right lobe of the liver. The center of the driver is typically centered at the level of the xiphisternum. Accurate positioning of the driver ensures that the largest cross-section of the liver is directly under the passive driver allowing good illumination of liver. Figure is from Venkatesh et al. [2]. 2.2 MRE Sequence MRE can be readily implemented on a conventional MR system with added hardware and software. For liver imaging, the MRE sequence that is most commonly implemented for clinical hepatic application is a modified gradient-recalled echo (GRE) sequence with a motion-encoding gradient (MEG) imposed along the longitudinal axis of the body [2]. Figure 3 provides a two-dimensional gradient echo-based MRE sequence. Typically, between two to four axial image sections are imaged through the widest transverse

dimension of the liver. As recommended by Ehman group [2] the following sequence parameters are used during MRE acquisition: TR/TE = 50/20 ms FOV = 30-48 cm Matrix = 256 x 64 NEX = 1 Phase offsets = 4 Band width = 33 Slice thickness = 6-10mm Using parallel imaging with acceleration factor of 2, each section can be acquired with an acquisition time of 16 seconds. The MRE can be implemented on scanners from 1.5 to 7T. Figure 3. Two-dimensional gradient echo-based MRE sequence. MEGs (shown in pink) that are synchronized with the applied vibration are added during the image acquisition. The MEGs sensitize the sequence to cyclic tissue motion in x, y, or z directions. The phase relationship (θ) between the MEGs and the applied waves can be adjusted in steps to acquire wave images at different phases of the cyclic motion. Figure is from Venkatesh et al. [2].

2.3 Generating Elastograms The third step of MRE is to us to generate images of hepatic stiffness. These elastograms are calculated using direct inversion of the differential equations describing the wave propagation. A review of the MRE methodology and associated equations are provided by Glaser et al. [3]. With commercially available systems, the wave images are automatically processed by the scanner to generate the quantitative images depicting stiffness (units of kilopascals [kpa]). These elastograms can be displayed in either gray scale or color scale. The inversion algorithms can also be configured to provide confidence maps to aid in identifying regions of reliable stiffness data [4]. Representative magnitude and wave images and elastograms are shown in Figure 4. Figure 4. Images acquired from MRE imaging. The left panel is a magnitude image that shows some signal loss and blurring due to the effects of the applied MEGs. The image aids in identifying anatomical locations on the corresponding elastogram (right panel). The center panel is the corresponding wave image which shows the pattern of propagating waves. The right panel is the elastogram (obtained by processing the wave information) which provides the stiffness measurements (0 to 8 kpa). The stiffness values reported by the elastogram are valid for regions with sufficient MRI signal, as seen in the magnitude image, and sufficient wave amplitude, as seen in the wave image. Figure is from Venkatesh et al. [2]. 3. Review and Analysis of Elastograms Elastograms can be reviewed for quantitative assessment of liver stiffness. The clinically relevant cut-off value for distinguishing between nonfibrotic and fibrotic liver tissue is a stiffness value of approximately 3 kpa; stiffness measurements above this cut-off indicate abnormal or diseased liver tissue [1]. In order to evaluate liver stiffness, the reader must review several images. The MR magnitude and phase images (Figure 4) are reviewed to confirm that blood vessels and boundary effects are excluded when defining regions of interest (ROIs) and that there is good wave quality in each two-dimensional slice [5]. If the color wave is acquired with cine mode, then the wave map can also aid in identifying ROIs that are free of wave interference [4]. Additionally, the reader can review the confidence map (Figure 5),

which displays crosshatched areas representing stiffness measurements that are less reliable (i.e. below 95% confidence), to confirm and optimize ROI selection [4,5]. The reader also reviews the elastogram for artifacts, i.e. hot/cold spots indicating wave interference or oblique wave propagation. Such artifacts are noted and excluded when defining the ROIs. In general, ROIs are placed in areas of the liver with adequate wave amplitude and usually do not extend closer than one-half wavelength to the liver margin as to avoid edge effects [2]. Additionally, ROIs are typically not placed over the left lobe of the liver since cardiac palpations can cause motion artifacts [4]. The mean stiffness within each ROI is then calculated using the elastogram image. This procedure is a manual process that is repeated for each slice acquired during MRE imaging. Algorithms aimed at automating the process of defining artifact-free ROIs and calculating liver stiffness have been created by the Ehman group at the Mayo Clinic [5]. Figure 5. Confidence maps aid in defining regions to analyze on elastograms. The left panel shows an elastogram with a 0 to 8 kpa stiffness scale. The right panel shows a confidence map overlaid on the elastogram. A threshold of 0.95 is applied in the confidence map and the black crosshatches represent regions with less valid measurements. When defining ROIs, regions with crosshatches should be avoided. Figure modified from Venkatesh et al. [4]. 4. VirtualScopics Analysis of MRE Images MRE is now being implemented in clinical trials due to its non-invasive nature and reliable ability to evaluate liver fibrosis. Given our expertise in MR imaging and the capabilities of our proprietary image analysis platform, which provides radiologists the necessary tools for viewing images and identifying ROIs, we are able to automatically extract mean stiffness measurements to facilitate liver fibrosis assessments to meet clinical trial goals and objectives. Additionally, our working relationship with the Ehman group, the pioneers of MRE imaging, further facilitates our ability to provide reliable MRE data to our sponsors.

5. References 1. Chen J, Yin M, Glaser KJ, Talwalkar JA, Ehman RL (2013) MR elastography of liver disease: State of the art. Applied Radiology: 5-12. 2. Venkatesh SK, Yin M, Ehman RL (2013) Magnetic resonance elastography of liver: Technique, analysis, and clinical applications. Journal of Magnetic Resonance Imaging 37: 544-555. 3. Glaser KJ, Manduca A, Ehman RL (2012) Review of MR elastography applications and recent developments. Journal of Magnetic Resonance Imaging 36: 757-774. 4. Venkatesh SK, Ehman RL (2014) Magnetic Resonance Elastography of Liver. Magnetic Resonance Imaging Clinics of North America 22: 433-446. 5. Dzyubak B, Glaser K, Yin M, Talwalkar J, Chen J, et al. (2013) Automated liver stiffness measurements with magnetic resonance elastography. Journal of Magnetic Resonance Imaging 38: 371-379.