MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Similar documents
SP SP-T-9

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Momentum 171 CCC Processor with Ethernet Communication Port

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

MODEL CIO-EN PROGRAMMING GUIDE MODBUS/TCP, MODBUS/RTU I/O MODULE. Revision A1 Rapid City, SD, USA, 09/2008

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Electronic timer CT-ERS.21

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Electronic timer CT-ERD.12

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

02/11/2015

DI-904MB/DI-905MB/DI-906MB

AND OPTIONAL ACCESSORIES

02/11/2015

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

MGate 5111 Quick Installation Guide

Contact protection relay

MGate 5105-MB-EIP Series

DI572 Digital Input Module

Output Voltage* (nom.)(adjustable)

08/07/2015

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Electronic timer CT-AHD.22

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Ethernet Interface Module

MGate 5105-MB-EIP Quick Installation Guide

78 Series Electromechanical Relay Selection Guide

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

MGate 5102-PBM-PN Series

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

iologik E1200H Series

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

NetBiter I/O Extender User Manual

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

TALON Network Manager- 2 & 6 Express

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

P3-SCM. General Specifications

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Features and Benefits. SNMP MIB-II for network management. Certifications

CompactBlock Guard I/O EtherNet/IP Safety Modules

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

DI561 Digital Input Module

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

DI-924MB. Thermocouple/Millivolt Input Module

DI-932MB/DI-934MB. RTD/Resistance Input Module. Four RTD or Resistance Inputs

COMTRAXX COM460IP. BMS-Ethernet-Gateway

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Electronic timer CT-ARS.11

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

TM221CE24R controller M IO relay Ethernet

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

DC562, digital input/output module,

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

TM241CE24T controller M IO transistor PNP Ethernet

Logic Controller Millenium Evo

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Model Number Structure

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

DX561 Digital Input/Output Module

TU531, TU532 Terminal Unit

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

AI561 Analog Input Module

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Features and Benefits. Certifications

TM221M16R controller M IO relay

MIC-2 Multi-instrument DATA SHEET

Industrial 2-port RS422/485 Modbus Gateway

DC561, digital input/output module,

TM241CE40R controller M IO relay Ethernet

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

TF501, TF521 Terminal Bases

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Transcription:

INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION. The CIO-EN Module is a convenient and cost-effective Modbus/TCP and Modbus/RTU interface capable of providing discrete control and monitoring of a SymCom overload relay over a Modbus or Ethernet network. The CIO-EN is designed to provide the following benefits in both new and existing installations: reduced field wiring greater operator efficiency ease in system startup and commissioning The CIO-EN Modbus I/O Module provides four (4) inputs and two (2) AC/DC rated relay outputs. It can be DIN rail mounted or mounted directly to a back panel. The CIO-EN s compact size, ease of wiring, and Modbus communications capability makes the use of traditional discrete devices on Modbus cost-effective and simple. The CIO-EN Module is compatible with SymCom s Model 777-P and 777-P1 overload relays. It simply connects to the side of the 777-P/P1 and in addition to the extended I/O functions, permits remote monitoring and control of the 777-P/P1 over a Modbus network. An additional remote reset input is available on the CIO-EN to reset a connected 777-P/P1. CONNECTIONS 1. Mount the CIO-EN in a convenient location in a properly rated enclosure. The module can be mounted to a back panel using screws or can be snapped onto a DIN rail. 2. For Modbus/RTU networks, connect the three Modbus wires (A, B, Shield) to the 5-pin connector on the front of the CIO-EN module. 3. For communication with a SymCom overload, connect the CIO-EN to the side of a 777-P/P1 via the 9-pin D-SUB connector located on the side of the CIO-EN. NOTE: Do not plug a modem or any other PC compatible device directly into the 9-pin D- SUB connector on the CIO-EN. 4. For Ethernet, connect an Ethernet cable to the Ethernet jack on the top of the CIO-EN module. 5. CIO-EN Inputs (refer to Figure 1): Connect one side of each input contact to C and connect the other side to I1, I2, I3, or I4. NOTE: CIO-EN input connections are dry contact connections only. 6. OUTPUT A, OUTPUT B and the REMOTE RESET connections are made on the top green connector of the CIO-EN Module. 7. Power the device by connecting 24VDC to V+ and V- on the front green connector. 8. The MODBUS MODULE NETWORK STATUS LED indicates communication between the CIO-EN and a Modbus master. The OVERLOAD COMM. STATUS LED indicates communication between the CIO-EN and the 777-P/P1 overload. 9. The yellow LED on the Ethernet jack indicates the link between the CIO-EN and a computer/lan network. The green LED on the Ethernet jack indicates network activity between the CIO-EN and a computer/lan network.

FIGURE 1: Typical Wiring Diagram (CIO-EN) TABLE 1: CIO-EN Terminals Terminal Designations Function V- 24 VDC - Connection V+ 24 VDC + Connection A RS-485 A Connection SHIELD Shield Connection B RS-485 B Connection R Remote Reset Switch R Remote Reset Switch C Input Common I1 Input 1 I2 Input 2 I3 Input 3 I4 Input 4 1 Output A terminal 1 2 Output A terminal 2 3 Output B normally open 4 Output B common 5 Output B normally closed

REMOTE RESET The R terminals can be connected to a normally open pushbutton to remotely reset a connected 777-P/P1 overload. DIAGNOSTIC INDICATOR LIGHTS (CIO-EN) The unit is energized when 24 VDC is applied between V+ and V- on the 5-pin connector on the front of the CIO-EN module. The MODBUS MODULE NETWORK STATUS (MNS) LED and OVERLOAD COMM. (OLC) STATUS LED will flash until communication is established. The MNS LED indicates the state of an upstream Modbus connection to the module. The OLC LED indicates the state of the overload connection to the module. For a complete description of the indicator LED s see tables 2 and 3 below: TABLE 2: MNS LED State Table For this state: LED is: To indicate: Not Powered Off The CIO-EN is not powered. Upstream Modbus/RTU The CIO-EN is communicating with an upstream Modbus/RTU device Green Comm. Operational and the CIO-EN is powered. Upstream Modbus/RTU Comm. NOT Operational Flashing Green The CIO-EN is powered but upstream communications are not established. TABLE 3: OLC LED State Table For this state LED is: To Indicate: Not Powered Off The CIO-EN is not powered. Overload Comm. Operational Green The CIO-EN is communicating with an overload device and the CIO-EN is powered. Overload Comm. NOT Operational Flashing Green The CIO-EN is powered but overload communications are not established. NOTE: If an unrecoverable error has occurred with the nonvolatile memory (which stores the device settings), the CIO-EN will enter a lockdown mode and flash both the OLC and MNS LEDs every second. The remote reset input must be triggered in order to reset all settings to factory defaults. The connected 777-P/P1 will not be reset when this occurs. The CIO-EN Ethernet jack on top of the unit contains LED s to represent communication and activity over the network. Tables 4 and 5 describe the LED functions. TABLE 4: Yellow Ethernet LED For this state: LED is: To indicate: No Link Off The CIO-EN is not connected to an Ethernet network. Active Link Solid Yellow The CIO-EN is connected to an Ethernet network. TABLE 5: Green Ethernet LED For this state LED is: To Indicate: No Network Activity Off The CIO-EN is not transmitting or receiving any data over Ethernet. Network is Actively Operational Green The CIO-EN is transmitting or receiving data over Ethernet.

MODBUS/RTU CONFIGURATION Flexible Modbus/RTU addressing is enabled by default on the CIO-EN. This means that when the CIO-EN is connected and communicating to a 777-P/P1 overload relay, the CIO will automatically assume and keep the Modbus address of the overload. If the CIO-EN is used as a stand-alone device, its Modbus address is defaulted to 1. MODBUS/RTU COMMUNICATIONS The CIO-EN Module provides the ability to communicate with both an upstream device (Modbus/RTU master) and a 777-P/P1 (Modbus slave). In order to communicate with the CIO-EN via an upstream device such as a PLC, DCS, SCADA system or PC, an RS-485 network must exist between the upstream device and the CIO-EN. The upstream device must be connected to the CIO-EN using an 18-24 AWG shielded, twisted-pair cable connected to A, B, and Shield of the 5-pin connector on the front of the CIO-EN module. The CIO-EN can be programmed as device address 01 to 99 and can communicate at baud rates of 9600, 19200, 38400, and 57600. The default communications settings for the CIO-EN are: Baud Rate: 19200 Parity: Even Modbus Address: Flexible when attached to overload; 1 when stand-alone Terminating Resistors The RS-485 network may require terminating resistors if the length between the CIO-EN and an upstream device exceeds 100 feet or if the twisted pair cable is in a noisy environment. When terminating resistors are required, 120Ω terminating resistors should be connected at both the CIO-EN (across A and B) and also at the upstream device (also across A and B). SymCom recommends that terminating resistors be used in all circumstances to optimize RS-485 signals. Existing Network Installations The CIO-EN can be added to a Model 777-P/P1 overload in an existing network. Flexible addressing is enabled by default; therefore, the CIO-EN will automatically assume the address of the 777-P/P1 upon being plugged into the overload. Equipment Setup 1. Connect the CIO-EN to the Modbus network using the communication terminals on the front of the unit (A, B and Shield). 2. Connect the CIO-EN to the overload using the serial port on the side of the overload. 3. Connect the power supply terminals to V+ and V- of the CIO-EN. NOTE: Ensure the power supply output is set to 24 VDC, and that it is off while being connected to the CIO-EN. 4. Power the overload, and then power the CIO-EN. Modbus/RTU Network Solutions Setup 1. Open Solutions 2. Click Modbus/RTU in the Select Network Connection Type box. 3. Ensure the network communication settings are correct, and the device connections are correct. 4. Right click the network window and select Auto Detect for Units. All units on the network will be automatically detected and should appear on the screen click on a unit to view its properties. NOTE: If the unit does not appear on the screen, recheck the device connections and network communication settings. Reattempt to Auto Detect for Units.

ETHERNET CONFIGURATION The default IP address for the CIO-EN is 192.168.50.1. However, flexible IP addressing is enabled by default on the CIO-EN. This means that when the CIO-EN is connected and communicating to a 777-P/P1 overload relay, the CIO-EN will automatically assume and keep the Modbus address of the overload as the last octet in its IP address. For example, if the CIO-EN is connected to a 777-P1 with a Modbus address of 29, the IP address will automatically become 192.168.50.29. Please note that the first three octets of the IP address (192.168.50) are not affected by flexible IP addressing. ETHERNET COMMUNICATIONS The CIO-EN Module is 10Base-T Ethernet compatible, meaning it is capable of transmitting data at a maximum rate of 10 Megabits/second. TCP/IP Protocols supported by the CIO-EN include: Modbus/TCP HTTP for an embedded webpage FTP for data logging ICMP (ping) DHCP for automatic IP assignment The default Ethernet communications settings for the CIO-EN are: IP Address: 192.168.50.1 as stand-alone; 192.168.50.FLEX where FLEX = 777-P/P1 Modbus Address Subnet Mask: 255.255.0.0 Gateway: 192.168.50.1 DHCP: Disabled Changing the Ethernet Configuration Settings The Ethernet configuration settings can be changed at any time through the CIO-EN's embedded webpage (Figure 2). To access this webpage, simply type the IP address of the CIO-EN in the address bar of an Internet browser (i.e. http://192.168.50.1/) and click on Configure. The CIO-EN will ask for a user name and password. The user name is: admin The password is: symcom Once the settings have been changed and saved, communications with the CIO-EN may be lost for a short period of time. Ethernet configuration settings can also be easily changed using SymCom's Solutions Software. Figure 2: CIO-EN Embedded Webpage Modbus/TCP Network Solutions Setup 1. Open Solutions 2. Click Modbus/TCP in the Select Network Connection Type box. 3. Ensure the Ethernet network communication settings are correct, and the device connections are correct.

4. Right click the network window and select Auto Detect for Units. All units on the network will be automatically detected and should appear on the screen click on a unit to view its properties. NOTE: If the unit does not appear on the screen, recheck the device connections and network communication settings. Reattempt to Auto Detect for Units. PHYSICAL DIMENSIONS (CIO-EN) All dimensions are in inches. FIGURE 3: Physical Dimensions (CIO-EN)

TABLE 6: CIO-EN SPECIFICATIONS Ethernet Controller Compatibility IEEE 802.3 Capability 10Base-T Output Relay Contact Rating SPDT (1), SPST (1) Pilot Duty General Purpose Inputs (4) General Purpose Voltage Range Current (for use with optional Remote Reset 777-P/P1 overload) Power Requirements 480VA @ 240VAC, B300 5A @ 240VAC 12 24VDC 2mA (typical) Normally open pushbutton rated 24VDC, 10mA (min.) Voltage 24VDC (+/- 10%) Current 95mA (max.) 70mA (typical) Power 2.28 W (max.) 1.7 W (typical) Weight 14 oz. Enclosure Polycarbonate Terminal (depluggable terminal block) Torque 3 in.-lbs. (max.) Wire AWG 12-20 AWG Safety Marks UL UL508 (File #E68520) CSA C 22.2 CE IEC 60947 Standards Passed Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air Radio Frequency Immunity, Radiated 150 MHz, 10V/m Fast Transient Burst IEC 61000-4-4, Level 3, 4kV input power Hi-Potential Test Meets UL508 (2 x rated V +1000V for 1 minute) Surge Input Power IEC 61000-4-5, Level 1 Inputs/Data Lines IEC 61000-4-5, Level 2 Environmental Temperature Range Ambient Operating: -20 to 70 C (-4 to 158 F) Ambient Storage: -40 to 80 C (-40 to 176 F) Class of Protection IP20 (Finger Safe) Relative Humidity 10-95%, non-condensing per IEC 68-2-3