FSA-CU Configuration Utility Programming Guide

Similar documents
USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

USB-Link 2 Technical Guide

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

USB-Link 2 Technical Guide

CommLink IV Technical Guide

Lab IP Addresses and Network Communication

MMI6070 Quick Start Guide

CodeLoader. Users Guide. P/N: Rev: OCT04

CommLink 5 Technical Guide

USB-Link Technical Guide

MigmaWalktime TM for pedestrian detection and walk time extension

HLSE02P Dual Port Serial to Ethernet server Quick Installation guide for Windows 7 32-bit

Product Family: Networking Hardware Number: AN-NH-012

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

1.0 Connecting OpenGN to FleX-Net TM

Canlan INSTALLATION MANUAL

N30 Supervisory Controller Quick Start

A Connect the Broadband Router

VisionTouch 5 Software

IMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information.

SmartPick Service Interface Installation, Setup and Event Log Download, Windows XP

HEX File Update TCS Technical Bulletin

and System Administration Terminals (SAT) Technician s Guide INT-1027 (IPK) Document Revision 1C (Applies to Release 1000 through Release 4500)

Appendix A Cable Pinouts

SmartPick Service Interface Installation, Setup and Event Log Download, Windows 7 & 8

COMMUNICATION WITH OTHER SERIAL DEVICES

Code Dynamics, Inc. Port Splitter

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Cable Pinouts. SRP I/O Module

Stevens SatComm. Product GUI Quick Start Guide

Talk Light Time Manager User Instructions

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

DFS/Cutter. Debugging Communication Problems

PFCS/Qualifier Interface

Hardware Installation Guide Installation (x3350)

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

MigmaIntersection TM for detecting pedestrians at intersection crossings

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

ADC REVISION HISTORY INTRODUCTION INSTRUCTIONS CABLE REQUIREMENTS

DI-808HV 8-Port Broadband VPN Router

Options. Parts List. Optional Expansion Hub Optional Ignition Module Optional Memory Card

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips.

1 System Requirements

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

F Series Indoor Fixed IP Camera. Quick Start Guide

Industrial Serial Device Server

Ethernet Network Card Installation and Operation Manual

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Abstract: The document defines the set up of the PC network card and tools for Ethernet communication to SQ6 and SQ6M ECUs.

4-channel MPEG-4 Video Encoder ACD-2000Q/ACD-2000QT. Ver Quick Installation Guide

Data Cable KXMDSWBRS3

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401

SERVICE BULLETIN NUMBER: SUBJECT: VISION 1000 MPEG VERSION EMBEDDED SOFTWARE UPDATE #1 COMPLIANCE LEVEL: OPTIONAL DATE: 5/1/2014

NX-588E USB Flash Programmer Instructions v1.1

QUICK START GUIDE. Section 6: MAC OSX 1. USB DRIVER INSTALLATION

PI Scanner User Guide

Trouble shooting the DeskCNC controller:

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

Microsoft PowerPoint 2016 Part 2: Notes, Links, & Graphics. Choosing a Design. Format Background

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

BiPAC 8200M. BiPAC 8200N

SVMi-8E/SVMi-16E Installation

installation manual SALES AND ADMINISTRATION (toll free)

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE

Bellatrix Systems, Inc. Maintenance Test Station For Windows XP Version 1.0. User Manual

Executive summary. Gather up the materials & tools required. Set up the BT2S for the ProChrono baud rate:

Nuance Field Certification Program 2-09

User s Guide. Ethernet Module for Barcode Printer

WVL2 Wireless Vehicle Link 2 Installation and Setup Manual

Technical Note. Configuration process to control domes connected to VT units with the Supervisor software handset

Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set

DT-CONFIG SOFTWARE USER S MANUAL

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

DI-704P Ethernet Broadband Router. Ethernet (Straight Through) Cable. 5V DC Power Adapter

CV-TAC400. Telephone Access System. Installation Guide

Ethernet (CAT5 UTP/Straight-Through) Cable. 5V DC Power Adapter

RC-SV Configuration Guide Revision 3

User s Manual 2005 All Right Reserved

3.1 I-7560 Pin Assignment and Specifications: Introduction

Connection to the OS32C

INDUSTRIAL POE SWITCH

RC-SV Configuration Guide (Rev 4)

Broadcast A/V Division V-SG4K-3G. HDMI / SDI Portable Signal Generator. Operation Guide

UPDATING THE FIRMWARE IN FRAME BASED MODULES...

MIU-1000 v. Revised: 4/20/2009. Copyright 2008, Traf-SYS, Inc.

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

Gateway for EIP - DF1 Allen-Bradley PLC

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

This guide will hopefully explain how Evolution works and what you need to do to get the system installed and configured.

Installation and Operation Manual for Comm-Card II Communications Card for Signal Booster II

TH800DS CONTROLLER MANUAL

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

GV-AS200 Controller. Hardware Installation Guide

VP- X Pro & VP- X Sport

Subject: ASC/2M Ethernet Connection Using Comtrol DeviceMaster RTS

IS-DM240, V User Manual. Ver 1.0

Advanced Graphical Interface, AGI 100

NKL Edge Software User Manual

Transcription:

FSA-CU Configuration Utility Programming Guide Revision 3 October 2013

Introduction The following guide will show you the basics of the FSA-CU configuration utility program. The CU can be used with the Edwards FS(C) 3/5/10 series conventional fire alarm panels, but its biggest use will probably be with the E-FSA64/250 addressable panels. This guide will deal with the addressable panel (but some screens will be the same as used with conventional panels). As you become more familiar with the E-FSA panels, you will find there is more than one way you can program them. This guide will show you probably the most common method. It will take you step by step from opening a new project to downloading to the panel. It does not show all the things you can do with the CU, however, such as writing a program from scratch before you even connect to the panel. There is a detailed Help menu built in to the program that should be able to answer any questions you might have. Before you begin programming your system, be sure all your devices are connected to the panel, the system is powered up, and the panel has been Auto Programmed. For your reference, the next page is copied from the Technical Reference Manual, P/N 3101202, which describes the Auto Programming procedure. When programming a system by the method described in this guide, leave the options on the Auto Program screen at No. You can refer to the Tech Manual for a description of the options. In this case, these will be changed as needed using the configuration utility. Auto Programming will get your panel up and running with a factory defaulted, general alarm system. From there you can use the FSA-CU program to make any necessary changes, such as creating custom messages for the devices and making correlation changes. 1

Auto Programming Notes: The menu button on the panel s keypad is: The default level 2 password is 2222. For a description of the options referenced in item 5, refer to the Technical Reference manual. When following this guide to program an FSA-64/250 panel, leave the Auto Program options at No. Auto Programming will erase all previous program information, and is typically only done once on a new installation. 2

Opening a New Job File After opening the FSA-CU program, click on Project New on the main menu at the top. On the Project Manager screen, click on New Project, enter a project name in the pop-up box, and click OK. 3

While the project you just created is still highlighted, click on Open Project. 4

Selecting Panel Type From the main menu at the top, select Configure Add Panel, then select the panel you are working with. (Note: if Configure is grayed out, click on the project s name immediately below. Configure should then turn a darker color so you can select it.) A main configuration screen will appear, beginning with the Panel tab. Next to Panel 1 in the upper left, click on the + symbol to drop down the available selections (you can select different sections by either clicking on each one under Panel 1 on the left, or by clicking on the option tabs, shown here below the display). 5

Communicating With Panel Communications with the panel is password protected. You must know the panel s level 2 password in order to connect your laptop or pc. On the Panel tab under Properties there is a selection called Password. The password entered here must match the panel s level 2 password (the default is 2222). If it doesn t, you will see the error below when you try to connect. 6

The next step is to upload the Auto Programmed information from the panel. Be sure your laptop is connected to the panel using the proper cable for the method you choose before you attempt to communicate. Click on the Communications tab. Select the communications method by clicking in the bullet (small white circle) next to the one you want. In this example, TCP/IP is selected (the panel must have the optional SA-ETH card installed). When you first connect to the panel this way, it s probably easiest to direct connect from your laptop s Ethernet port to the SA-ETH card in the panel using a standard network cable. Be sure the IP address in the Properties box to the right is the same as the panel s IP address (you can change this by clicking in the IP address box if necessary). By default, the SA-ETH address is 192.168.1.3. When (if) you connect the panel to the building s network, you can change the panel s IP information as needed (described later under Panel Properties). If you are using the optional SA-232 serial card to communicate, select the COM Port bullet. A Properties box will appear allowing you to change settings, but most of the time they can be left at default (you may have to change the Com Port Number depending on what the laptop is using). Before communicating to the panel with the SA-232 card, however, you must first enable the RS232 port at the E-FSA panel. From the main menu on the panel, select Program, then scroll down to RS232 CU Enable and press Enter, then while the cursor is next to On, press Enter again. After each upload or download, you will have to re-enable the RS232 port if you wish to reconnect (also note this port will time out, or disconnect, with no activity). 7

Note: When selecting the communications method, click on the bullet above the symbol in the Communications Method box. Clicking on the image will highlight it, but may not actually select it. Attached at the end of this document is AE Bulletin 100913, which will give you more information on the different communications methods and how to set up your laptop. When ready, click on Connect. A Communications Status screen will pop-up and then should quickly disappear. If the screen remains and shows it s trying, but failing to communicate, then double check the settings and cable connections and try again. (Remember to enable RS232 port at that panel if using the COM Port method and SA- 232 card, even if you think you already turned it on.) 8

Uploading (Reading) From Panel After connecting to the panel, click on Read from panel. A Communications Status screen will appear as the panel information is uploaded. When finished, another pop-up will say Read from panel complete click OK. Select Yes when it asks Overwrite CU data with panel data?, then Close the Communications Status screen. Finally, click on Disconnect to stop communicating with the panel. 9

Panel Properties After you have uploaded the panel information, return to the Panel screen by clicking on the Panel tab. On the right side is a Properties box with the panel s default parameters. Most of these can be left at their default values, but if you need to make a change, just click in the box in the right column next to the item. As mentioned earlier under Communicating with Panel, panels using a SA-ETH Ethernet card have a default address of 192.168.1.3. This Properties box is where you can change those IP settings (the network administrator should be able to provide you with the proper settings for your network). 10

Device Configuration Next, click on the Devices tab, then select Device Configuration. A Configuration screen will appear showing all the devices that are connected to the panel with their default configurations and messages. You can begin making any necessary changes here. 11

To change the device description, for example, click in the Message Line 1 and/or Message Line 2 box for a particular device, and type the description you want (a device s loop number and address is the default device message). If you want to change a device type, click in the Device Type box, and a drop down box will give you a list of choices available. The device type (such as Pull Station) will automatically appear on the panel s LCD when the device goes active or is in trouble, so you do not need to include that in the device message. Note: The device type here must match the P1/P2 switch setting for those addressable modules with the device type switch, such as the E-IDC2B. For example, if the switch for an input on an E-IDC2B module is set in the Supervisory position, you cannot change the device type in the CU to Pull Station, because that is an Alarm type. If the device type in the program does not match the actual device on the loop after you download (Write to panel), you will get a Device Type Mismatch error on the panel. You can refer to the Help in the lower right of the Device Configuration screen to review what all the different device types are and which settings correspond to each type (see below). When finished making all the changes, Close the screen. 12

Correlations From the main screen, click on the Correlations tab next. When the panel is Auto Programmed, Correlation Group 1 is automatically created. This correlates all the alarm input devices to all the alarm output devices (any alarm input device that activates will trip all signals) for a general alarm system. Note that it does not include non-alarm devices such as supervisory inputs or relay outputs. On the left side of the Correlations screen are all the input devices and output devices that are included in the program (in this case, from when the panel was Auto Programmed). The right side of the screen shows what devices are part of a particular Correlation Group. The Correlation Group number will be highlighted at the top under Correlations. Immediately beneath that will be the Activation Count. This determines how many input devices that are part of the Correlation Group must activate before the outputs in that group will turn on. (Note: Activation Count feature is available with v3.2 FSA-CU and higher.) The above example shows that in Correlation Group 1, input device addresses 1, 2, & 7 on loop 1 are correlated to activate output device address 6 on loop 1 plus the two NACs on the main panel. The Activation Count is set for one, so if any of the inputs alarm, all outputs will activate. 13

To add a device to a Correlation Group, highlight it on the left side, then click on the right pointing arrow (there may be an addressable relay used for door holders, for example, that needs to be part of the general alarm programming). To remove a device, highlight it on the right side, then click on the left pointing arrow. To create a new Correlation Group (you may have certain detectors that must also activate relays for elevator recall), select an unused number at the top under Correlations, (click on the drop down arrow) then add devices as described above. A device can be part of more than one Correlation Group. When finished, Close the screen. If your system is going to be general alarm, and there are no addressable relays, most of the time you will not have to make any changes to the Correlations screen. Note: You would only need to set the Activation Count higher than 1 when you require cross zoning. For example, if there are two smoke detectors in an elevator lobby, and both must alarm before the elevator is recalled, you would create a separate Correlation Group with just those two smokes and the relay used for elevator control, and set the Activation Count to 2. 14

Dialer Configuration If the panel has a SA-DACT dialer module installed for central station monitoring, from the main screen, click on the CMS tab. Click on the Telco Dialer box in the upper left and a Properties box will appear on the right. Change the dialer mode setting to Single Line or Dual Line by clicking in the box in the right hand column next to Dialer Mode. Most of the time the other options can be left at default. Next click on the Telco Account 1 box. Another Properties box will appear on the right. Here you have to at least enter your account number and phone numbers. You can change the other options if needed, otherwise leave them at default. 15

Note: Only if you are connecting to a second central station for monitoring do you need to select Telco Account 2, otherwise just fill in information for Account 1 (Account 2 should therefore have no phone numbers or account numbers entered). If you inadvertently enter information for Account 2, the panel will display dialer troubles because it will be trying to connect to another account that does not exist. Also, if your panel has a dialer installed but you are not ready to use it (no phone lines, don t have an account set up yet, etc.), leave the Dialer Mode at None or Modem Only. Otherwise, again, the dialer will try to connect to something that s not there, and cause troubles. 16

Custom Banner Under normal conditions the panel s LCD should only show the date and time of day. You also have the option of creating a 2 line, 20 character custom banner to display on the LCD as well. This could be something like the project s name, or the name of the building the panel is installed in. To create the banner, click on Banner from the drop down options on the left side of the screen. In the Properties box towards the right, click in the Line 1 and/or Line 2 box to create your banner. 17

Downloading (Writing) To Panel When you have finished creating your program, it s time to download to the panel. Click on the Communications tab and connect to the panel as described earlier under Communicating with Panel. Before you can download (write) to the panel, you must enter a level 2 password at the panel (by code, any program changes made to a system must be tested, which therefore requires someone on site). The easiest way to do this is to press the menu key on the panel s main display board, go to Control and enter your password (the default is 2222). After you have entered the password, you can exit the menu by pressing the menu key again. The panel s display should now be flashing a Login:2 message in the upper right of the LCD. When ready, click on Write to panel to begin downloading. When finished downloading, click on Disconnect (the panel will display a Programming Mode trouble until you disconnect). After downloading, the panel may take a few minutes for it to be clear of any troubles (depending on the number of devices and the number of changes, the panel may go in and out of trouble as the system updates the device programming). When finished, only the green Power LED on the panel s front display should be lit, with no trouble messages on the display. 18

Saving Project When you have finished creating your program, be sure to save it before you close the file or exit the CU (in reality, the program automatically saves as you make the changes, but it s good practice to manually save it first.). If you just select Save, the program will save using the same name and revision number. If you do a Save As*, you have the option of saving the program as a different name, or you can use the same name, but a different revision number (this can be handy if you want to keep track of changes, which can easily be done using the Difference Report under the Reports menu). *Note: If you open an existing project to make changes and wish to save previous versions, do a Save As immediately after opening the project and create a new name or revision number. Then make the necessary changes under the new name or revision. 19

Conclusion As mentioned in the beginning, it is not the intent of this guide to show you all the different things you can do with the configuration utility, or all the different programming methods. This just shows the basics for getting a system up and running. The following pages are taken from AE Bulletin 100913 with more detailed information on connecting a laptop to the panel 20

E-FSA Panel to Laptop Connections Introduction There are three different option modules available for the E-FSA series of small analog panels. Each allows for communications between the panels and a laptop computer running the FSA-CU configuration utility program. You must have one of these three to be able to communicate to an E-FSA panel with a computer. The modules are not included with a panel and must be ordered separately. 1. The SA-232 provides an RS-232 interface to the panel. The SA-232 has a four position terminal block, and requires a download cable with a DB9 female connector. This DB9 connects directly to a DB9 male connector on a laptop. For those computers without a serial port, a USB to RS232 serial port adapter is required (purchased locally). The Edwards part number for the download cable is 260097, or you can make your own. To build your own download cable, refer to the picture of DB9 connector to the right and pin designations below. Pins on DB9 are numbered looking at the female side facing you.. Proper Connection Female DB9 to SA-232 DB9 pin which is connects to 2 RX TX 3 3 TX RX 4 5 Common GND terminal on SA-232 1 SA-232 card. Wire colors shown are for 260097 cable. RTS connection not used. The SA-232 card is small pc board measuring approximately 2 wide x 1 high. In lieu of ordering one card for every panel, consider making up a portable download assembly for each technician. Connect the wire leads of the download cable to the SA-232 terminal block, and use heat-shrink tubing or a small plastic case available from a local electronics store to protect the assembly, leaving the small ribbon cable accessible. Connect the ribbon 21

cable to the main board to download to the panel, then take it with you when you re done. Be careful when unplugging the ribbon cable from the panel. The panel does not have to be powered down, but the physical connection is delicate. Since most computers today do not come with a serial port, you will probably need a USB to RS232 Serial port adapter (not supplied by Edwards). Be sure the adaptor works with the particular laptop and operating system being used. Also pay particular attention the first time the adaptor is plugged into the laptop to make sure the drivers install properly. You will need to know which COM port is configured when the adaptor is installed. To find out, open Device Manager and look for the USB-to-Serial Comm Port as shown below. This will be needed when you select the COM port to use in the FSA-CU Configuration Utility Communications tab. Be sure the COM port number assigned to the USB adaptor is between 1 and 8. If higher than 8, you will need to reassign it a new number. You can do this by right clicking on the port, then select Properties > Port Settings > Advanced > COM Port Number. 2. The SA-DACT dialer module can be used as a modem to provide communications to the control panel over a telephone line system. Phone line connections must be available for the SA-DACT and laptop computer. 3. The SA-ETH provides an Ethernet network connection. This connection can also be used as a direct connection from a laptop to the control panel. A standard network cable (crossover type not required) is all that s needed from your laptop to the SA-ETH card. See below for computer network 22

connection settings for both Windows XP and Windows 7 operating systems. From your Windows XP Start menu, go to Settings, Network Connections. Double click on Local Area Connection. Stay on the General tab, click Properties. 23

Scroll down to Internet Protocol (TCP/IP) option. Highlight it, and click on Properties. Select the Use the following IP address option. 24

Note: If the pc already has an IP address listed in the field, copy it down so that the address can changed back to that setting once panel programming is complete. The SA-ETH card defaults to IP address 192.168.1.3. Enter an IP address that is different from that by one or two places (or different from whatever the panel s IP address is if it s been changed). Then hit Tab, and Subnet mask will fill in as shown. Hit OK. You can now connect a network cable between your laptop and SA-ETH card to communicate with the panel. 25

If your laptop has Windows 7 operating system, go to Control Panel from your Start menu. Click on the Network and Sharing Center icon. Select the Change adapter settings option on the upper left hand side of the screen. 26

This will display the available network connections on your laptop. Highlight the Local Area Connection option, right click on it and select the Properties option. Highlight the Internet Protocol Version 4 (TCP/IPv4) option and click on Properties. Then follow the same steps to set the IP address as described earlier for Windows XP. For more laptop to panel connection troubleshooting tips, refer to AE Bulletin 121709. The latest version of the FSA-CU can be found at www.edwardssignaling.com. 27