Modbus Actuator Control

Similar documents
Modbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

HART. Actuator Control. Redefining Flow Control

Profibus Actuator Control

Profibus. Serial communication and control of Rotork actuators. Established Leaders in Actuation Technology

DeviceNet. Controller Area Network control of Rotork actuators. Redefining Flow Control

Foundation Fieldbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation

DeviceNet. Controller Area Network control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

DTM Solutions. Setup, parameterisation, monitoring, and asset management information. Redefining Flow Control

Modbus RTU Actuator Control Mk2 Option Card Technical Manual (IQ Pro, IQT Pro, SI Pro, EH Pro, ROMpak and Q)

Foundation Fieldbus. actuator control. Established Leaders in Actuation Technology. Foundation Fieldbus. Freedom to Choose, Power to Integrate

Note 1: Throughout this manual the Modbus Module Mk2 may simply be referred to as the module.

CVA Range. Control and Monitoring Facilities. Keeping the World Flowing

Modbus RTU Actuator Control Mk 3 Option Card Technical Manual. (IQ3, SI3, CVA, CMA, K-Range) Publication PUB _0918

Profibus Actuator Control Profibus DP Option Card Installation Manual

IQ Range Intelligent Electric Actuator

IQ Pro SIL option TÜV Certified for use in SIL 2 & 3 applications

IQ SIL Option. IQ actuators for use in applications up to SIL 3. sira CERTIFICATION

Foundation Fieldbus FF01 Mk 2 Option Card Installation Manual

Established Leaders in Actuation Technology. Pakscan IIE high integrity master station. Publication S110E issue 09/04

Pakscan Field Unit Technical Manual. (IQ / IQT 3 rd generation, CVA, CMA, ROMpak, CK, SI3) Publication PUB _1116

CVA Range. Control and Monitoring Facilities. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

Skilmatic SI3-3 Electric Fail-Safe Actuators

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

Pakscan P3 Wireless Quick Start Guide

E.CK Centronik Control and Indication Specification CENTRONIK FUNCTION AND PROTECTION DETAILS. Local Control. Local Indication.

IQT 3 rd Generation Intelligent Part-turn Electric Actuator

Electric Actuators and Control Systems. Established Leaders in Valve Actuation. Pakscan P3 Systems. Network Control. Publication S000E Issue 05/07

PRODUCT INFORMATION. DeviceNet Triple Play Digital Communications Board. SA Actuator with AUMA Matic Motor Controls

Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves

IQ Range. IQ and IQT Multi-turn and Part-turn Electric Valve Actuators Control and Monitoring Facilities. Redefining Flow Control

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

ROSoV Actuation Solutions

Established Leaders in Actuation Technology. In-Vision PC based supervisory control. Publication S210E issue 04/03

PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455

HART Actuator Field Unit Technical Manual. (IQ / IQT 3 rd generation, CVA, CMA DEV_REV2) Publication PUB _0615

Foundation Fieldbus FF-01 Option Card Installation Manual

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD Instruction Manual. Publication P972E Issue 08/09

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

/8 DIN Motorized Valve Controller

Pakscan P3 System. Network Control. Established Leaders in Actuation Technology

S-series Serial Interface

The final column has Navigation controls to the individual FCU screens.

Chapter 1. Introduction. Additional Documentation

QUCM Limitorque Controller

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

profibus Actuator control by Profibus Profibus DP module - serial communication unit publication S113E issue 11/99

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Designing a Reliable Industrial Ethernet Network

Skilmatic SI 3 Range. Spring-Return and Double-Acting Self-Contained Electro-Hydraulic Actuators. Keeping the World Flowing

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

M-series Serial Interface Series 2

Mega_Link Telemetry Communication System

3rd Generation Skilmatic SI Range

Profibus DP Option Card Technical Manual. IQ Mk3, IQT Mk3, SI 3, CVA, CMA. Keeping the World Flowing

INTEGRATED AUTOMATION ACTUATORS AND OPERATORS

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD-8140 & AD Instruction Manual. Publication P971E Issue 08/09

ATS Automatic transfer switches Advanced version

Designing a Reliable Industrial Ethernet Network

/8 DIN Universal Process Indicator

M-series Serial Interface Series 2

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Pakscan General Purpose Field Control Unit Technical Manual

Getting Started with your D3000M Series Module

Documentation. M-Bus 130-mbx

FEATURES DESCRIPTION SPECIFICATIONS

MULTIPLE PROTOCOLS FOR VALVE ACTUATOR CONNECTIVITY

Revolutionizing control wiring

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

S-series Serial Interface

TECHNICAL MANUAL. NR 1177_rev01 MASTER STATION MS202

EXCEL XR. Metering Pump. You can rely on LMI. EXCEL XR Communications Model

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

F02 SERIES ELECTRIC ACTUATORS

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Wall-/Pipe Mounted Universal Process Indicator

100% electricity. Automatic transfer switch controllers ATL series

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Metering Pumps. The Intelligent Metering Pump. PROTEUS Series. an Accudyne Industries brand

Intrinsically Safe Temperature Concentrator System

DI-904MB/DI-905MB/DI-906MB

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation

INTELLIS. Modbus Direct Network Monitor

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

GE MDS, LLC. NETio Series. Protocol Communications Supplement. March 2013 Part No A01, Rev. C

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

NetBiter I/O Extender User Manual

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

HART Actuator Field Unit Technical Manual Modular Design Electric Valve Actuators

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Transcription:

Modbus Actuator Control Serial communication and control of Rotork actuators Redefining Flow Control

Contents Section Page Introduction 3 Modbus Overview 4 Modbus Features Modbus Module 5 RS-485 Communication Highway 5 Rotork Modbus Module Formats 6 Modbus RTU 6 Modbus Commands 6 Dual Channel Module 7 Single Channel plus Repeater Module 7 Control and Feedback 8 Valve Torque Profile Data 10 Function Code Support 10 Configuration 10 Lightning Protection 11 Modbus Technical Data 11 Rotork is the global market leader in valve automation and flow control. Our products and services are helping organisations around the world to improve efficiency, assure safety and protect the environment. We strive always for technical excellence, innovation and the highest quality standards in everything we do. As a result, our people and products remain at the forefront of flow control technology. Uncompromising reliability is a feature of our entire product range, from our flagship electric actuator range through to our pneumatic, hydraulic and electro-hydraulic actuators, as well as instruments, gearboxes and valve accessories. Rotork is committed to providing first class support to each client throughout the whole life of their plant, from initial site surveys to installation, maintenance, audits and repair. From our network of national and international offices, our engineers work around the clock to maintain our position of trust. Rotork. Redefining flow control. 2

Introduction Direct Modbus control of Rotork actuators by 2-wire RS-485 serial communications provides a simple and reliable control strategy for valve automation. Rotork electric actuators may be controlled over the low cost RS-485 network using the Modbus RTU protocol when they are fitted with the Rotork Modbus option module. The inherent flexibility of the Modbus RTU protocol allows the systems engineer to control the data flow on the highway as well as the registers read and written to. There are no complications with device description files or special tools needed to set up a Modbus system. The PLC and DCS drivers are all simple and easy to use. Redefining Flow Control 3

Modbus Overview Modbus is the most popular communication protocol in use today. It has the widest acceptance and highest number of applied systems of any automation protocol. International Open Standard Highly reliable standardised communications Simple connectivity, easy configuration Rotork Modbus module: Compatible with all IQ, IQT, SI/EH, CMA, CVA, ROMpak, Q and K range actuators RS-485, RTU communication Low installation and maintenance costs High control system flexibility Data transfer between 300 and 115 kbaud Simple plant expansion Cabling requires 2 wires only per channel provided the ground potentials are equal Three versions available: Single Channel, with and without repeater and Dual Channel For more information on Modbus consult the web site at http://www.modbus.org. Modbus was developed by Modicon in the 1980s and remains one of the leading protocols used in the field of process control and automation. 4

Modbus Module The Modbus module is fitted inside the actuator electrical housing and interfaces directly with the actuator electronics. Once fitted, all the normal commands associated with moving the actuator together with feedback and some historical data become available on the Modbus RS-485 highway. There are a number of user settings to be made for the system variables and actuator performance, such as the baud rate and the slave address of the actuator. These are set by either using the infrared or Bluetooth communication link to the actuator, or by writing over the network to the appropriate registers in the module. All the settings are held in non-volatile EEPROM memory on the card. RS-485 Communication Highway The Modbus module is a slave device and it uses 2-wire, half duplex, RTU communications on the balanced RS-485 highway. An additional connection is provided at each actuator for a common wire linking all the actuators together. The RS-485 standard requires the common mode differential voltage between all the points on the highway to be less than 7 Volts. If the site wide common mode voltage is above this level, the additional connection to a third wire should be made to ensure successful field communication. PLC Address 1 Address 2 Address 3 1,500 metres at 9,600 baud Data Rate (baud) 300 600 1k2 2k4 4k8 9k6 19k2 38k4 57k6 115k2 Maximum Cable Length 24 km 12 km 12 km 6 km 3 km 1.5 km 1.2 km 1.0 km 750 m 500 m Total Spur Length 2 km 1 km 1 km 500 m 500 m 500 m 500 m 300 m 200 m 100 m Note: Each actuator includes up to 0.6 m of cable spur. Calculations based on Belden 8770 cable parameters, 18 AWG, 1 mm 2 cross section, 3 cores. Redefining Flow Control 5

Rotork Modbus Module Formats The Rotork Modbus Module is available in three forms for different applications. The Single Channel card is the simplest of the three with only one highway connection. The Dual Channel card has two independent communication channels and is usually connected to two highways with redundant communication paths. This increases the plant availability by reducing the probability of communication failure preventing the actuator from being controlled. The third option has an internal repeater so that it can be used on a single highway and allows the highway to be extended in distance or number of units without an external repeater. The repeater option also allows connection in a ring topology. Communications is normally through a master at one end of the ring. If the ring gets broken, a second master communicates with all the devices downstream of the break, from the other end of the ring. This also allows continued communication with all devices after a cable break or short-circuit. Modbus RTU The protocol used for the communication is Modbus RTU (Remote Terminal Unit). This is the most common Modbus application, where each network will have one master, usually a PLC or DCS, and several slave devices. In all cases the Rotork module is a slave device and will only send a message in response to a request from the master on the system. Because all messages are under the control of the master there should never be any data collisions or interruptions. The master also controls the message retry mechanism and monitors each slave for its responses to requests for data. Only one slave device at a time sends messages on the highway. The Rotork module only supports half duplex communication. On a 2-wire RS-485 Communications Highway cable the pair is used for passing messages in one direction at a time, either from the master to the slave, or vice versa. This means the master is transmitting only half of the time, hence using half duplex communication. Full duplex requires 4 wires and is more complex, while a half duplex communication system is easier to troubleshoot and keep running. Modbus Commands The single channel option is the simplest implementation of the Modbus module to apply. There is only one RS-485 highway connection to the actuator and only one channel inside the actuator for communication. The module operates as an RTU slave on the network and uses only one address. 2-wire RS-485 Single Communications Highway Full actuator control and data reporting Network or tool selectable termination Full isolation on the RS-485 connection Includes lightning protection on RS-485 highway connection Fully network configurable 6

Dual Channel Module The dual channel version caters for those applications where redundant highways are being used for high integrity field connection. The two channels are isolated from one another and provide independent communications. Both channels share the same processor and baud rate for the communications. The address of each channel may be the same or different to the other. The ability to use dual highways makes this version ideal for critical installations where redundant communication paths are required. Two 2-wire RS-485 communication highways Full actuator control and data reporting Network or tool selectable termination Full isolation on both channels and between channels Includes lightning protection on each RS-485 highway connection Channel 1 takes priority over Channel 2 when simultaneous messages are received Fully network configurable Common or different address for the two channels Common communication speed for both channels Single Channel plus Repeater Module The single channel with repeater Modbus module includes an internal repeater to allow the highway to be extended over greater distances, or for those applications where a ring is to be constructed. The repeater works in both directions and has minimal turn round time between transmit and receive modes. The number of connected modules can be extended to over 32 using the repeater version, however the recommendation for repeaters is that no more than 9 are used in a system. With 9 repeaters it is easy to build a system over 15 km in length that will run at 9600 baud. The operation is similar to the single channel unit with the addition of the repeater function. Two connections for single RS-485 highway use Full isolation between the two segments Minimal turn round time within the repeater to ensure maximum speed communication Allows for spur and ring topology networks Includes lightning protection on each RS-485 highway connection Network or tool selectable termination on both segments Redefining Flow Control 7

Control and Feedback The Modbus module allows data to be collected from the actuator about the status of the valve and actuator combination. This data includes logging features when the module is in an IQ or IQT actuator. In addition, full digital and analogue control of the actuator is available without the need to add more components to the actuator. Control Data IQ/IQT Q CVA CMA ROMpak SKIL/EH K Digital Outputs: Stop Close Open ESD Relay 1 * 7 7 7 7 7 Relay 2 * 7 7 7 7 7 Relay 3 * 7 7 7 7 7 Relay 4 * 7 7 7 7 7 Partial Stroke 7 7 7 7 7 Analogue Outputs: Desired position * Extra relay board must be fitted. 8

Digital Inputs: Feedback Data IQ/IQT Q CVA CMA ROMpak SKIL/EH K Actuator moving Close limit switch Open limit switch Actuator running closed Actuator running open Remote control selected RUN Selector in Remote STOP Selector in Local 1 Thermostat tripped 7 2 Monitor relay Valve Obstructed / Jammed Manual movement 7 Motion inhibit timer active 7 7 Positioner control enabled 7 Watchdog tripped 3 7 7 Slow mode 4 7 7 7 7 7 7 Open interlock input 7 7 7 7 7 Close interlock input 7 7 7 7 5 Battery low 7 6 7 7 7 Aux input 1 7 7 7 7 Aux input 2 7 7 7 7 Aux input 3 7 7 7 7 Aux input 4 7 7 7 7 Analogue Inputs: Measured actuator position Current actuator torque 7 7 7 7 7 1 Manual control using Enlight. (see www.rotork.com) 2 Fault Relay 3 UPS Fault 4 IQT only 5 HW Partial Stroke input 6 UPS in use 7 Torque on CVA, Thrust on CVL Redefining Flow Control 9

Valve Torque Profile Data With IQ and IQT actuators the Modbus module also makes available some of the standard data logger feedback information. A torque profile is provided in each direction together with the total number of times the motor starter has been energised in each direction. There is a short delay after the actuator Starts - Open stops (around 2 seconds) 7796before this data is compiled and Starts presented - Close to the network. 7421 Closed 0 10 20 30 40 50 60 70 80 90 100 Open Opening Direction Torque Starts - Open 7346 Starts - Close 7782 The registers containing this information can be accessed periodically to update the control system with the latest data. Function Code Support The Modbus module supports all the major function codes and uses a technique whereby data and commands can be read and written using more than one code. For example, all actuator control and indication can be obtained using register read/write functions 03 and 16, or discrete inputs can be read with function 02 and so on. Full position control of the actuator can be achieved by writing a value to the position control register. Closed 0 10 20 30 40 50 60 70 80 90 100 Open Closing Direction Torque Closed 0 10 20 30 40 50 60 70 80 90 100 Open g Direction Torque Code Function 01 Read Output Coil status 02 Read Input status 03 Read Holding register 04 Read Input register 05 Force single coil 06 Preset single register 07 Read Exception status 08 Loopback Diagnostic test 15 Force multiple coils 16 Preset multiple registers 17 Report Slave ID Configuration The Modbus module requires a number of configurable parameters to be set, including the address and baud rate for communication. All the parameters may be set using the communication link itself. In most cases, the default setting will match the valve operation. To cater for those more exacting applications, the ability to match the communication and actuator performance to the valve characteristics is invaluable. In the case of the IQ and IQT actuator the primary parameters can be set using the actuator infra-red communication link. Description Modbus Address Baud Rate (baud) & Parity/Stop bits Actuator Tag Name Action on Loss of Communications Limited Range Position Min & Max Deadband and Hysteresis Motion Inhibit Time Aux Input Mask & ESD DI-4/Net Disable Valve Jammed Time Manual Movement Travel Watchdog Timeout & Communications Fault Timer Analogue Input Max Network Termination off/on 10

Lightning Protection All the communications ports on each variant of the Modbus module are fitted with components designed to reduce the effect of high voltage induced signals, such as those generated by a lightning strike. A combination of gas discharge tubes, rectifier diodes and Zener diodes ensures that in most cases the induced voltage levels cause no damage to the communication network. To make full use of the internal protection, the screen should be earthed and a separate common wire should be used. Modbus Technical Data Interface: Number of Channels: Address Range: Data Rate: Parity: EIA-485 (RS-485) suitable for 2-wire connection. 1 on Single channel, fully isolated from the actuator circuits. 2 on Dual channel, fully mutually isolated. 2 on Single channel with repeater, fully mutually isolated. 1 to 247, address 0 reserved for broadcast messages. 300 to 115k2 baud, selected over the Modbus network. Configurable, odd, even or none. Communication Protocol: Modbus RTU (slave device). Function Codes: User Defined Digital Inputs: User Defined Digital Outputs: Enclosure: Environment: Power Consumption: All popular function codes including 01, 02, 03, 04, 05, 06, 07, 08, 15, 16. 4 off (IQ, IQT, SI/EH only), potential-free input contacts. 4 off contacts 5 A, 120 VAC or 1 A, 30 VDC (IQ/IQT and CMA require additional relay board option). Suitable for fitting within Rotork IQ, IQT, SI/EH, K ROMpak and Q range actuators. -40 to +70 ºC, environmentally protected by Rotork actuator double-sealing to IP68 (IQ, IQT, SI/EH, K and Q ranges). All Modbus module power is taken from the actuator, no external supply is required. Redefining Flow Control 11

Redefining Flow Control www.rotork.com A full listing of our worldwide sales and service network is available on our website Rotork plc Brassmill Lane, Bath, UK tel +44 (0)1225 733200 fax +44 (0)1225 333467 email mail@rotork.com Scan with your smart phone for more information on rotork products and services PUB091-001-00 Issue 05/15 As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at www.rotork.com The name Rotork is a registered trademark. Rotork recognises all registered trademarks. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rotork is under licence in the UK. Published and produced in the UK by Rotork Controls Limited. POWSH0615