Software Manual Virtual COM for Ethernet Driver / Configuration Tool

Similar documents
Windows Driver Manual Label Printers

Windows Driver Manual Label Printer

Printer Driver Manual Label Printer Rev. 5.00

Software Manual Net Configuration Tool Rev. 1.01

User Manual Network Interface

Installation Manual JPOS Driver. Rev. 3.05

Software Manual Net Configuration Tool POS Printer Rev. 2.03

User's Manual Ethernet Interface

Software Manual Net Configuration Tool Rev. 4.05

Software Manual Net Configuration Tool Rev. 4.03

SRP-E300/302 THERMAL RECEIPT PRINTER

Software Manual Label Artist-II Rev. 2.01

API Reference Guide Web Driver Rev. 1.04

TM Printer Service and Support Utility for Windows Version 2.xx User s Manual (English)

Unified Label Utility-II

Instructions for MX350 Firmware Upload

magicolor DL Series Firmware Updater Guide A A

USB driver and Software Installation. UPS Monitoring and Management Software

INTRODUCTION...1. Under Windows 98SE... 2 Under Windows ME... 6 Under Windows Under Windows XP...10

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Setting up the PC ready for BESA 11

Galileo Print Manager Installation Guide

VSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later.

Windows Driver Manual SRP-150 Thermal Printer Rev. 1.05

Windows Driver Manual SRP-275 Impact Printer Rev. 3.05

Windows Driver Manual SRP-275III Impact Printer Rev. 1.02

Windows Driver Manual SRP-350plus Thermal Printer Rev. 2.07

Hard Disk Drive (HDD) Installation Instructions

DairyPlan Interface Setup Index. 3. Gateway Setup (VC3/4 equipment)

INSTALLING THE PS3 XBOX READY SOFTWARE:

AN-77XX-XP 2K MCS77XX. Windows-2k & Windows-xp

DRIVER INSTALLATION MANUAL

Unified POS Utility Manual Thermal Printers

MF9300. Software setup guide

Hard Disk Drive (HDD) Installation Instructions

RTE for WIN32. Installation Manual (Rev.7.0) Midas lab

Windows Driver Manual SRP-275II Impact Printer Rev. 1.03

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

Fiery Installation Instructions for the WorkCentre 7300 Series

Galileo Print Manager Installation Guide

Product Family: Networking Hardware Number: AN-NH-012

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Software User's Manual

Utility Manual B-gate configuration utility

IPAdminTool User s Manual

Unified Utility-II Manual Label Printer

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

Windows Driver Manual SRP-350II Thermal printer Rev. 1.04

Application Note #5494 Upgrading Plus Ethernet Radio Firmware September 9, 2013

User Manual Network Interface

User Manual. Thermo Scientific Orion

Hard Disk Drive (HDD) Data Protection Kit Installation Instructions

Label Design Program Label Artist-II Manual Rev. 1.01

Cover. MATWorX Installation Guide NWA ISSUE 2.1

Kramer Electronics, Ltd. ETHERNET Configuration (FC-11) GUIDE

Midland BT Updater 1.0. Option 1: Wizard procedure

GP-N100 Utility Software Manual

Instructions to install IntelliBar Printer Driver on Win 7, Vista and Server 2008/2008-R2 For Model 48 and 412 Network Printers

CellRoute 3G. Fixed Wireless Terminal. Data Connectivity

Power Xpert Meter 2000 Gateway Card Kit

User's Manual. Network Interface. Rev SRP-F310II / SRP-F312II SRP-F313II.

Installation and Configuration User's Guide

Voice Pager MODEL:VP101

Windows Driver Manual STP-103II Thermal Printer Rev. 1.02

Serial 2-Port ExpressCard

Configuring the Switch with the CLI Setup Program

Windows Driver Manual SRP-350II Thermal printer Rev. 1.03

INTRODUCTION...1. I. Install the driver of USB TO IRDA Adapter... 2 Under Windows 98se/Me...2 Under Windows 2000/XP...9

12.0 Setting up the PC ready for BESA 11

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

CHAPTER 17 COMPILING/SIMULATING/DOWNLOADING A PANEL APPLICATION

Windows. Updating Camera Firmware. Get ready

Bluetooth Connection Manual. Mobile Printer SPP-R300 SPP-R400.

Centurion PLUS CPC4 Download Guide using C4 File Transfer Utility

Longshine Technologie Europe GmbH

Updating the Firmware for Digital SLR Cameras (Mass Storage) Windows

Manual Software Firmware Loader V1.1

C5100 Computer Connections & Software Install Guide

How to configure the Matlab interface

Procedures to Install Eye Com's ImageMouse and ImageMouse Plus using Windows XP platform

Table of Contents. D-Link SharePort Plus... 4 Introduction...4 System Requirements...4 Features...5. Installation... 6

Lab Establishing a Console Connection to a Router or Switch Instructor Version

CARD PRINTER. INSTALL GUIDE Revision 2.05

Be sure to download and utilize the correct version. If the incorrect version is utilized, then an error message will be shown.

Parallel Printers Set-Up

Windows XP Software Installation Instructions GCC Elite Series Printers

Windows XP - MVX Printer Driver Installation

Windows Download & Installation

Power Xpert Meter 2000 Gateway Card Kit

Install Manual. Advanced Printer Driver Ver.4. Overview. Installation and Setup. Silent Installation. M Rev. G

Install Manual. Advanced Printer Driver for TM-T81 Ver.4. Overview. Installation and Setup. Silent Installation. M Rev.A

User Manual of Acer EasyLink v1.0

Firmware install with Windows XP

Olimex Field Update Kit

Windows Driver Manual SRP-350III Thermal printer Rev. 1.00

POWERSTATION 2015 Installation and License Setup (Rev: 11/16/2016) (631)

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition

Windows Driver Manual SRP-350IIOBE Thermal printer Rev. 1.00

AN-27. Installing USB Drivers for Pumpkin's CubeSat Kit

P1322 Operator s Manual

Transcription:

Software Manual Virtual COM for Ethernet Driver / Configuration Tool Rev. 2.08 SRP-270 / SRP-275 SRP-275II / SRP-280 SRP-350 / SRP-350II SRP-350IIK SRP-350plus / 352plus SRP-350plusII / 352plusII SRP-500 / SPP-R200 SRP-F310 / SRP-F312 SRP-330 / SRP-340 SLP-T400 / SLP-T403 SLP-D420 / SLP-D423 SLP-TX400 / SLP-TX403 SLP-DX420 / SLP-DX423 SLP-DX220 / SLP-DX223 SRP-770II / SRP-770III http://www.bixolon.com

Table of Contents 1. Manual Information... 3 2. Usage Environment... 3 2-1 Recommended Specifications... 3 2-2 Virtual COM for Ethernet Driver Supported Printer Models... 3 3. Software Installation & Deletion... 4 3-1 Installation... 4 3-2 Deletion... 6 4. Configuration Tool Usage... 7 4-1 Configuration Tool Functions... 7 4-2 Printer Search... 8 4-3 Configuration of the Ethernet and the Virtual COM Port... 9 4-4 Virtual COM Port Addition... 10 4-5 Virtual Serial Port Deletion... 11 4-6 Firmware Update of the Ethernet Interface... 11 5. Virtual Serial Port Management... 12 5-1 Port Deletion Via the Device Manager... 12 5-2 Port Setting/Number Modification Via the Device Manager... 13 6. Win32 API... 15 6-1 File I/O API... 15 6-2 Communication API... 15 6-3 Precautions for Serial Communication Programming... 15 Rev. 2.08-2 -

1. Manual Information Virtual COM for Ethernet Driver / Configuration Tool This manual provides information on the usage of the Virtual COM for Ethernet Driver and Configuration Tool software associated with Ethernet interface use on BIXOLON printers. This software can be used to set and use the Ethernet interface via the serial communication mode. Executing the installation file (BXLVCOM4ETHERNET Installer x86 v1.0.x.exe / BXLVCOM4ETHERNET Installer x64 v2.0.x.exe) will install both the Virtual COM for Ethernet Driver and Configuration Tool programs. The Latest file versions is available for download from the BIXOLON website (www.bixolon.com). We at BIXOLON maintain ongoing efforts to enhance and upgrade the functions and quality of all our products. In following, product specifications and/or user manual content may be changed without prior notice. 2. Usage Environment The Virtual COM for Ethernet Driver and Configuration Tool programs operate under the following conditions. 2-1 Recommended Specifications Hardware Supported Operating Systems Hard Disk Capacity Memory Capacity IBM PC/AT or IBM PC/AT-compatible Windows XP Windows 2003 Server / Windows VISTA Windows 2008 Server / Windows 7 / Windows 8 Minimum 1Mbyte or higher space required 128Mbytes or higher 2-2 Virtual COM for Ethernet Driver Supported Printer Models The Virtual COM for Ethernet Driver software can be used only with Ethernet-supported printers. Rev. 2.08-3 -

3. Software Installation & Deletion 3-1 Installation Virtual COM for Ethernet Driver / Configuration Tool 1) Execute the BXLVCOM4ETHERNET Installer x86 v1.0.x.exe / BXLVCOM4ETHERNET Installer x64 v2.0.x.exe file. (This file must first be downloaded.) 2) Accept the terms of the software license, and click the Next button. Rev. 2.08-4 -

3) Clicking the Install button begins the installation process. (Install to: BIXOLON\VCOM4NET\ in the Windows Root Folder) 4) During installation, the following message will appear. Click the Continue Anyway button. 5) The following message appears upon the successful completion of installation. Rev. 2.08-5 -

3-2 Deletion 1) Click and activate the Add/Remove Programs icon in the Control Panel. 2) Select Virtual Com for Ethernet Driver 1.x.x and click the Change/Remove button. 3) Click the OK button to completely remove the application. Rev. 2.08-6 -

4. Configuration Tool Usage Virtual COM for Ethernet Driver / Configuration Tool The Configuration Tool program can be used to create a serial port, and set and/or delete printer devices. 4-1 Configuration Tool Functions After completing installation via the BXLVCOM4ETHERNET Installer x86 v1.0.x.exe / BXLVCOM4ETHERNET Installer x64 v2.0.x.exe file, run the Configuration Tool program. The program location is indicated as follows. (Start Program Menu-> BIXOLON -> BXLVCOM4NET -> Click the Configuration Tool shortcut icon.) 1 7 8 2 3 4 5 6 9 11 12 The Configuration Tool functions are described as follows. 1 Main Screen - This is the main screen of the Virtual COM for USB Configuration Tool program. 2 Printer Device Sequence Number - This function displays the connection sequence of printer devices. 3 Mac Address of the connected Printer via the Ethernet interface - This function displays the printer device models that are turned on and connected via the Ethernet interface. 4 IP Address - This function displays the current IP Address of the connected printer via the Ethernet Interface. 5 Port Number - This function displays the current Port Number of the connected printer via the Ethernet Interface. Rev. 2.08-7 -

6 Assigned Info - This function displays the current set virtual serial port number. If one is not set, the status is shown as Not Assigned. 7 STEP 1 Printer Search - This function is used to search the printer device models that are turned on and connected via the Ethernet interface. 8 STEP 2 Printer Configuration - This function is used to configure the Ethernet Interface and the Virtual Serial port Number. 9 STEP 3 Test Print - This function is used to perform a print test on the printer selected from the list box. The serial port must be set in order to perform a print test. 10 Detach the assigned port - This function is used to disconnect a connection between a printer selected from the list box and a virtual serial port. 11 Port Management - This function is used to add/remove virtual serial ports. 12 Exit - This function is used to exit the Configuration Tool program. 4-2 Printer Search The Configuration Tool program is used to search the printer. To search the connected printer via Ethernet interface, click the STEP 1 Printer Search button in the Configuration Tool. The following window appears during the searching the printer. Rev. 2.08-8 -

4-3 Configuration of the Ethernet and the Virtual COM Port To configure the Ethernet and the Virtual COM port, click the STEP 2 Printer Configuration button in the Configuration Tool. Clicking the Configuration button brings up the following dialog box. 1) Enter the IP Address, Subnet Mask, Gateway, Local Port, and Inactivity Time in the Network Setting section of the Ethernet interface card settings. 2) Select the port number to be used from the added virtual serial ports list to set the virtual port, and designate the Baudrate. Match the Baudrate to that specified on the test page printout from the corresponding printer. 3) After completion of settings, click the Save button to save the setting values. NOTE - For information regarding the Network Setting section, submit an inquiry to the network administrator of the corresponding area. - When connecting a virtual serial port, if the corresponding port is connected to another printer, the existing connection is automatically disconnected and the connection is made to the selected printer. - The test page printout is generated by holding down the Feed button while turning the printer power on. - Following the saving of settings, a printer search is repeated. Rev. 2.08-9 -

4-4 Virtual COM Port Addition Virtual COM for Ethernet Driver / Configuration Tool The Configuration Tool program is used to add a virtual COM port. To create a port, click the Port Management button in the Configuration Tool. 1) Clicking the Port Management button of the Configuration Tool brings up the following dialog box. 2) Click the Add Port button to add a port. The following warning message appears when adding a port if using a Windows XP or higher operating system. 3) Click Continue Anyway on the warning message, and the following message will appear upon port addition success. Rev. 2.08-10 -

4) If the port has been added successfully, the virtual serial port added will appear as follows. NOTE When adding a virtual serial port via the Add Port function, the port number indicated in COM# is determined according to the operating system. Refer to section 5 (Virtual Serial Port Management) of this manual for information on modifying the virtual serial port number. In addition, the warning message appears once for each virtual serial port added. 4-5 Virtual Serial Port Deletion Click the Port Management button to delete the connection settings of virtual serial ports. The Delete All Port button can be used to delete all virtual serial ports. 4-6 Firmware Update of the Ethernet Interface 1) To update the Ethernet interface firmware, the firmware update file must first be prepared. 2) After setting the file to a specified folder, click the Firmware Update button. 3) The file is selected, and the Ethernet interface firmware is updated. NOTE - The Firmware Update button and its function differs from that of the printer firmware update, and thus a different utility must be used for the firmware upgrade of the printer itself. - If the printer power is turned off during a firmware update, damage to the Ethernet interface card may result. Rev. 2.08-11 -

5. Virtual Serial Port Management Virtual COM for Ethernet Driver / Configuration Tool Port number modification, port deletion, and serial communication setting are done via the Device Manager. Control Panel -> System -> Device Manager: Upon examination of the ports (COM & LPT) section, the port(s) added previously via the Configuration Tool program can be seen. 5-1 Port Deletion Via the Device Manager Select the virtual serial port to be deleted and click the right mouse button. On the popup menu, select Uninstall to delete the port. Following deletion, the Configuration Tool program must be executed, and the changes must be updated. Rev. 2.08-12 -

5-2 Port Setting/Number Modification Via the Device Manager 1) Select the desired virtual serial port and click the right mouse button. On the popup menu, select Properties. 2) In the Properties window, click the Port Settings tab. 3) The Port Settings tab can be used to set the baud rate, data bits, parity, stop bits, and flow control of a port. 4) Click the Advanced button to modify the port number and/or designate buffer settings. Modification of buffer settings is not recommended. The COM port number is changed by selecting a number in the combo box. Rev. 2.08-13 -

Following port modifications, the settings utility must be run to update changes. If a printer was connected previously, the connection setting must be disconnected. CAUTION The selecting port must not already be in use. Following port modification, clicking the Yes button can result in the appearance of a warning message. Click the Yes button to finalize and set the modified information and settings. Port modification on certain operating systems will require the repeat opening of the Device Manager to confirm changes. Rev. 2.08-14 -

6. Win32 API The Virtual COM for Ethernet Driver program can be used in serial communication programming. Refer to Microsoft MSDN regarding the Win32 API for serial communication. NOTE Currently, only basic serial communication APIs are supported. In the future, additional APIs suited to user needs are set to be added. 6-1 File I/O API 1) CreateFile(): Supported 2) WriteFile():Supported 3) ReadFile():Supported 4) CloseHandle():Supported 6-2 Communication API 1) BuildCommDCB():Supported 2) BuildCommDCBAndTimeouts():Supported 3) CommConfigDialog():Supported 4) DeviceIoControl():Supported 5) GetCommModemStatus():Supported 6) GetCommState():Supported 7) GetCommTimeouts():Supported 8) PurgeComm():Supported 9) SetCommState():Supported 10) SetCommTimeouts():Supported 6-3 Precautions for Serial Communication Programming With CreateFile, any port name ranging from 1 to 9 may be used as COM1 to COM9. To use ports 10 to 256, the following format must be used, \\\\.\\COM10 to \\\\.\\COM256. Rev. 2.08-15 -