Monte Carlo Simulations for In Vivo Internal Dosimetry (including phantom development)

Similar documents
State of the art of voxel phantom development

Anthropomorphic Phantoms

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

MODELLING RADIATION TRANSPORT IN VOXEL GEOMETRIES WITH THE MONTE CARLO CODE MCNPX

DEVELOPMENT AND CHARACTERISATION OF A HEAD CALIBRATION PHANTOM FOR IN VIVO MEASUREMENTS OF ACTINIDES

Development and Use of Computational Anthropomorphic Phantoms for Medical Dosimetry Nina Petoussi-Henss

Voxel phantoms and Monte Carlo methods applied to internal and external dose calculations.

Image-based Monte Carlo calculations for dosimetry

ICRP Symposium on Radiological Protection Dosimetry

TWENTY YEARS OF VISUAL MONTE CARLO

OBJECT ORIENTED DESIGN OF ANTHROPOMORPHIC PHANTOMS AND GEANT4-BASED IMPLEMENTATIONS ABSTRACT

Towards patient specific dosimetry in nuclear medicine associating Monte Carlo and 3D voxel based approaches

Improvement in the calibration techniques of approved dosimetry services in Spanish nuclear power plants of whole body counters with NaI detectors.

Three Dimensional Dosimetry Analyses In Radionuclide Therapy Using IDL And MCNP-based Software Tools

Mesh Human Phantoms with MCNP

GSF Male and Female Adult Voxel Models Representing ICRP Reference Man

Library of Mesh and NURBS female phantoms for pulmonary in vivo counting studies

Tomographic Anthropomorphic Models. Part IV: Organ Doses for Adults due to Idealized External Photon Exposures

Computational Anthropomorphic Models of the Human Anatomy: The Path to Realistic Monte Carlo Modeling in Radiological Sciences

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code

CT vs. VolumeScope: image quality and dose comparison

IMPLEMENTATION OF SALIVARY GLANDS IN THE BODYBUILDER ANTHROPOMORPHIC PHANTOMS

Michael Speiser, Ph.D.

EFFECTIVE DOSE RATIOS FOR TOMOGRAPHIC AND STYLIZED MODELS FROM EXTERNAL EXPOSURE TO PHOTONS

Absorbed Fractions for Multi-Region Models of the Kidneys in ICRP/ICRU Voxel Phantoms

Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology

Internal radionuclide dosimetry of model and patient based voxelised phantoms using the GATE toolkit

Dose Point Kernel calculation and modelling with nuclear medicine dosimetry purposes

Deformation of mesh-type ICRP reference computational phantoms in different statures and postures for individualized dose calculations

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

Mathematical methods and simulations tools useful in medical radiation physics

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Evaluation of RayXpert for shielding design of medical facilities

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Av. Professor Lineu Prestes São Paulo, SP ABSTRACT

NKS GammaUser

GSF MALE AND FEMALE ADULT VOXEL MODELS REPRESENTING ICRP REFERENCE MAN THE PRESENT STATUS

ANALYSIS OF CT AND PET/SPECT IMAGES FOR DOSIMETRY CALCULATION

Attenuation Coefficients for Layered Ceiling and Floor Shields in PET/CT Clinics

ISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry

3D/4D HUMAN MODELING AND MONTE CARLO DOSE CALCULATION FOR RADIATION PROTECTION, IMAGING AND RADIOTHERAPY

Computational Phantoms of the ICRP Reference Male and Reference Female

SESAME: A NEW TOOL FOR THE NUMERICAL DOSIMETRIC RECONSTRUCTION OF A RADIOLOGICAL ACCIDENT CAUSED BY AN

FASH and MASH: Female and Male Adult human phantoms based on polygon mesh surfaces Part II: Dosimetric calculations

MEASUREMENTS OF AIR KERMA AS FUNCTION OF POTENTIAL IN X-RAY TUBES FOR ESTIMATES STANDARD QUANTITIES USED FOR DOSIMETRIC EVALUATION

Application of MCNP Code in Shielding Design for Radioactive Sources

Quantitative imaging for clinical dosimetry

Monte Carlo Simulations for the Purpose of Efficiency Curve Calibration for the Fastscan Whole Body Counter

Deliverable D10.2. WP10 JRA04 INDESYS Innovative solutions for nuclear physics detectors

Katja the 24 th week of virtual pregnancy for dosimetric calculations

Proton dose calculation algorithms and configuration data

Modeling the ORTEC EX-100 Detector using MCNP

JRP EMRP ENV09: MetroERM. Exploitation plan D4.3.1

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

DRAFT TO BE SUBMITTED TO HEALTH PHYSICS JOURNAL

Advantages of combining gamma scanning techniques and 3D dose simulation in dose optimisation problems.

Detector simulations for in-beam PET with FLUKA. Francesco Pennazio Università di Torino and INFN, TORINO

Basics of treatment planning II

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

DUAL energy X-ray radiography [1] can be used to separate

Small scale dosimetry for 211 At distribution in thyroid and liver models using AlfaMC Monte Carlo simulations

Limitations in the PHOTON Monte Carlo gamma transport code

Improved Detector Response Characterization Method in ISOCS and LabSOCS

Master of Science Thesis. Activity quantification of planar gamma camera images

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

An Investigation into the Limitations of Tomographic Scanning for Quantitative Nondestructive Gamma-ray Measurements of High Density Radioactive Waste

A Monte Carlo shielding model for PET/CT clinics

METHODOLOGY FOR CONVERTING CT MEDICAL IMAGES TO MCNP INPUT USING THE SCAN2MCNP SYSTEM

Outline. Monte Carlo Radiation Transport Modeling Overview (MCNP5/6) Monte Carlo technique: Example. Monte Carlo technique: Introduction

LA-UR- Title: Author(s): Intended for: Approved for public release; distribution is unlimited.

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Scatter Correction Methods in Dimensional CT

Disclosure 7/24/2014. Validation of Monte Carlo Simulations For Medical Imaging Experimental validation and the AAPM Task Group 195 Report

PARAMETRIC STOCHASTIC MODEL OF BONE STRUCTURES TO BE USED IN COMPUTATIONAL DOSIMETRIC PHANTOMS OF HUMAN SKELETON *

Introduction to Positron Emission Tomography

Ch. 4 Physical Principles of CT

Comparison of Predictions by MCNP and EGSnrc of Radiation Dose

Hybrid Imaging for Patient-Specific Dosimetry in Radionuclide Therapy

Case Study Core Capabilities in Nuclear Forensics

Development and anatomical details of Japanese adult male/female voxel models

PSG2 / Serpent a Monte Carlo Reactor Physics Burnup Calculation Code. Jaakko Leppänen

664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

Small Angle Gamma Ray Scatter: What Is The Impact On Image Quality

Voxels and Medical Applications. FLUKA Beginners course

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

VCU Radiation Oncology

3-D PET Scatter Correction

GammaUser2014 Spectrum Analysis Exercise

Monte Carlo simulations

Optimization of Beam Spectrum and Dose for Lower-Cost CT. Mary Esther Braswell. Graduate Program in Medical Physics Duke University.

Theoretical Investigations of Tomographic Methods used for Determination of the Integrity of Spent BWR Nuclear Fuel

Geant4 in Brachytherapy

Transcription:

Monte Carlo Simulations for In Vivo Internal Dosimetry (including phantom development) Gianfranco Gualdrini ENEA - Istituto di Radioprotezione Bologna - Italy IRPA11 Madrid - Spain 23-28 May 2004

Quantities for Internal Dosimetry t 0 +τ Committed Equivalent Dose H (τ)= H (t) dt T τ t 0 Committed Effective Dose E(τ) =..H T (τ) w T T

Internal Dosimetry - Routes of Intake Inhalations Ingestion Injection Wound Through intact skin (possible only for few radionuclides e.g HTO, iodine isotopes)

Compartment Model Indication of ICRP pub. 78 Transfer Absorption Excretion

E(50) Calculation and Monte Carlo E(50) = w U SEE(.T..S) T S H T (50) T S E(50)= Committed Effective Dose w T = Tissue weighting factor U S = Number of Nuclear Transformations in Source Organ S during 50 years post intake. SEE= Specific Effective Energy Monte Carlo Plays a role!

Estimation of U S Compartment Modelling Excreta Measurements 50 y U S = 0 q S (t) dt Monte Carlo In Vivo Measurements Detector Efficiency MDA - Calibration q S (t) = activity in organ S at time t

Definition of MDA MDA = 3 + 4.65 S B t ε MDA = a-priori MDA (Bq) ε = in vivo detection efficiency (cps.bq -1 ) t = measuring time (s) S B = uncertainty of the counts in the region of interest for the blank measurement

Dosimetric Models

Specific Effective Energy SEE(T S) = R E R Y R w R AF M T (T S) R Energy absorbed in T AF(T S) = Energy emitted in S E R = Emitted energy from Radiation R Y R = Yield of Radiation R w R = Radiation R weighting factor T = Target Organ S = Source Organ M T =Mass of target organ Monte Carlo

Summarizing

MONTE CARLO AS A TOOL FOR CALIBRATION AND DOSIMETRY STUDIES from simplified phantoms to complex voxel models

ANSI Phantom Intercomparison on Thyroid Measurements

Bottle Phantom Italian - Hungarian Intercomparison It is possible to simulate various sizes

Each polyethylene module contains 4 rods with homogeneous radioactive source: 57 Co(122; 136 kev) 60 Co(1.17; 1.33 MeV) 137 Cs (662 kev) 40 K (1.46 MeV) St. Petersburg Phantom

BOMAB Phantom Standard adult 10 elements phantom for intercomparison studies

BOMAB in vivo measurement WBC standard chair calibration condition

Lawrence Livermore National Laboratory phantom for lung dosimetric studies

What is the extent of the uncertainties associated with the usage of more or less complex phantoms? (Courtesy D.Franck)

The use of more detailed experimental phantoms and Monte Carlo evaluations based on complex mathematical phantoms is necessary in the case of radionuclides present in single organs of complex geometry, in presence of significant variations of dimensions and morphology of the investigated subjects, especially for low energy gamma emitters.

A Monte Carlo simulation is suitable to calculate efficiency e variations for two different measurement geometries (e.g. standard chair and bed geometries)

G.H. Kramer Studies (Radiation Protection Bureau-Ontario Canada) Studies on the influence of the lung deposition conditions on the counting efficiencies. MCNP analytical model of the trunk with simulation of different source geometries. The uncertainty on the Pu-239 (17 kev) source geometric distribution can cause underestimations of a factor of 4, overestimation of a factor ~30 until the complete loss of the counts vs. an assumed homogeneous distribution of the nuclide in the lungs. Kramer validated his model vs. the LLNL e JAERI experimental calibration phantoms. The validation suggested an improvement to the model, with the addition of a detailed representation of the sternum and the ribs. A further interesting study was performed by Kramer through Monte Carlo simulations to assess the effect of the possible self-attenuation of homogeneously distributed natural Uranium in a lung phantom and the effect of activity deposited in the ribs on the activity estimate from a lung in vivo measurement

Oedipe -1/2 An interesting example of computer aided calibration procedure is represented by the voxel model of the Lawrence Livermore trunk phantom for lung contamination measurements developed by the group of IRSN. The CT phantom obtained from the Lawrence Livermore in employed with an appropriate software for the evaluation of the internal dose (Oedipe).

Oedipe -2/2 (Courtesy D.Franck)

Advanced Mathematical Human Models Nowadays the high computer power available allows complex Voxel human phantoms to be managed in Monte Carlo (VOXEL= 3-D pixel) These are based on CT or NMR scans Employment in medical field (not yet routine), and increasing application in research in dosimetry for radiation protection

The GSF phantoms family 1/4 GOLEM (courtesy M.Zankl)

The GSF phantoms family 2/4 The thoracic region, at heart level, in ADAM (MIRD analytical phantom) and GOLEM (voxel phantom) (courtesy M.Zankl) BABY (8 weeks old ~ 9 million voxels) CHILD (7 years old ~ 9.5 million voxels) GOLEM (38 years old male, 176 cm high with 69,2 kg weight veryclose to the standard man ~ 14,5 milioni di voxel)

The GSF phantoms family 3/4 (courtesy M.Zankl) HELGA DONNA IRENE

The GSF phantoms family 4/4 Comparison between female phantoms: EVA (analytical from MIRD) DONNA (voxel) (courtesy M.Zankl)

VIP-Man (courtesy G. Xu) 38 years male -186 cm height 103 kg - 3,7 billion voxels 0,3x0,3x1 mm

NRPB Phantom: NORMAN NORMAN (NMR) adult ~ 9 million voxels (2x2x2mm) and 31 different materials External Dosimetry: Jones - STUDY on the model effect on HT and E. Significant differences at low energies and for AP irradiations. Now used also for NIR

Software: MC_In Vivo J. Hunt (Istituto de Radioproteção e Dosimetria (Rio de Janeiro-Brazil)). Visual Basic (VB5), operative under Windows 95. Adjustments to the voxel phantom NORMAN (NRPB): it is able to simulate a large variety of subject-detector configurations and evaluate the associated counting efficiencies. Validation Campaign vs real activities of reference experimental phantoms (NRPI phantom- Czech Republic Phantom, BfS Phantom -Germany, BPAM- Transuranium and Uranium Registry Americium Bone Phantom USA)

Simulation MC_in vivo of 241 Am (59.5 kev) deposition in a point in the posterior part of the lung (interaction points in the lung and in the Phoswich detector-sandwich : e.g NaI(Tl) + CsI(Tl)) are shown). Simulation MC_in vivo of 235 U (186 kev) uniformly deposited in the lung (interaction points in the lung and in the NaI(Tl) detector are shown) Courtesy J. Hunt ENEA-Istituto per la Radioprotezione

Yale (G. Zubal) Phantom: VOXELMAN Union of two CT examinations (trunk and head) using mathematical algorithms. 6,3 million voxels (2x2x2mm) Segmentation to be carefully checked Employed in different application fileds and available on web site on request.

CIEMAT 1/3 (Courtesy J.M. Gómez-Ros)

CIEMAT 2/3 (Courtesy J.M. Gómez-Ros)

Knee voxel phantom for actinides in vivo measurements CIEMAT 3/3 (Courtesy J.M. Gómez-Ros)

Baby Child Onago A summary of voxel model by M.Zankl Voxelman NORMAN VIP-Man Adelaide Otoko Golem MAX Irene Name UF newborn UF 2-month Donna Frank Helga Visible Human Age (y) 8 w 7 35 adult 38 14 adult 38 6 d 2 m 40 48 26 38 35 Gender f f f m m m f m m f m f m f m m Height (cm) 57 115 178 170 186 157 170 176 170 174 170 186 175 Mass (kg) 4.2 21.7 79 95 81 103 Whole body 3.8 5.4 32 f 163 51 Whole body adult f Whole body 70 70 103 48 65 69 75 Body region Whole body Whole body Whole body Head to thigh Whole body Whole body Torso Whole body Whole body Whole body Whole body Whole body Head and torso Head to thigh Head to thigh Voxel (mm 3 ) 490. 2.9 19.0 56.25 8.0 0.1 / 64.0 62.5 9.6 34.6 0.35 0.30 35.2 2.8 9.6 4.3 46.7 17.6 9.6

Assessment of Specific Absorbed Fractions recent evaluation through detailed voxel models

As explained before the absorbed fraction (AF) is a necessary quantity for the dose calculation from incorporated radionuclides. It is defined as the fraction of the emitted energy from a given source organ that is absorbed by a given target organ. The Specific absorbed fraction (SAF) is obtained from AF dividing by the target organ mass. This transfer quantity is therefore crucial for the evaluation of the committed equivalent dose and the committed effective dose and variations in the employed SAF values have an immediate influence on the committed dose evaluation.

Since a long time the set of SAF values that is widely used is based on Monte Carlo (and sometimes point kernel ) calculations based on the MIRD mathematical phantom, that is analytical. It has to be pointed out that the MIRD model is affected by significant approximations and simplifications compared with the strong heterogeneity of a real subject. The employing of voxel models allows a significant improvement in the SAF calculations

A summary internal dosimetric studies involving voxel model by M.Zankl Radiation type Energies Quantites Model MC code Photons, radiopharmaceuticals 20 kev 4 MeV SAFs, Organ doses Baby, Child Home-made Photons 10 kev 4 MeV SAFs NORMAN Home-made Photons 20 kev 4 MeV SAFs Baby,Child, Golem,Voxelman Home-made Photons, electrons 10 kev 4 MeV AFs, SAFs Voxelman MCNP-4B Radiopharmaceuticals Organ doses Baby,Child,Golem Home-made Electrons Radionuclides Photons 100 kev 4 MeV 10 kev 4 MeV SAFs Committed dose AFs, SAFs VIP-Man Golem Voxelman EGS4 Home-made MCNP-4B Photons 10 kev 4 MeV SAFs Child,Otoko,Onago EGS4 Photons, radiopharmaceuticals 10 kev 4 MeV SAFs, Organ doses Frank,Golem,Vis. Voxelman, Donna,Helga,Irene Home-made

A comparison of SAF calculation between MIRD and voxel phantoms (courtesy M.Zankl)

SAF calculation: a comparison on two different MCNP simulations on the same voxelman phantom

An example of Monte Carlo aided design for in vivo monitoring ENEA IRP Bologna

Behavior of actinides in the skeleton Plutonium in the bone Americium in the bone Years after injection

241 Am in vivo measurement For an effective and fast screening on internal contamination from actinides it is recommended to determine the activity of 241 Am in the bone (skull or knee). 241 Am decays with a photon of 59.5 kev energy The mean free path at this photon energy is: 1.7 cm in cortical bone 3.6 cm in trabecular bone 4.5 cm in soft tissue The contamination distribution can be assumed homogeneous on the bone surfaces. As a function of time after intake one can also assume that the nuclide migrates inside the bone, therefore generating an homogeneous volumetric contamination (as a first approximation).

The need of suitable calibration phantom To calibrate the instrumentation to be employed in the routine measurement it is necessary to rely on a suitable calibration phantom where a known radioactivity is placed. A commercial Alderson TM developed for angiography studies was used.

Design Strategy Traditionally such phantoms are developed painting the internal and external bone surface by radioactive paints. This technique does not guarantee a homogeneous application of the paint. Point sources in optimised position (based on Monte Carlo) + correction factors (based on Monte Carlo) where choosen as a more reliable solution.

The adopted procedure A CT scan of the plastic phantom was made. A first analytical multilayer model was produced for MCNP. This model was afterwards updated with a voxel model well suited for the voxel MCNP patch developed at ENEA. The Monte Carlo models were employed in order to state the best configuration for 24 241 Am sources used to simulate the homogenous distribution in the Alderson plastic phantom. This was accomplished determining 24 isovolumetric regions, whose centroids defined the source positions. All the calibration set-up was simulated, including the two Ge detectors A correction coefficient was evaluated for the calibration factor to take into account the difference between the in vivo measurement on the subject (assumed homogeneous) and the calibration condition (with point distributed sources).

The evolution of the calibration head models Preliminary analytical model Plastic calibration phantom Voxel model

The procedure

Conclusions The validity of a Monte Carlo result is strongly linked to the correspondence of the model to the real irradiation experience to be simulated: the more complete and accurate the modelling, the more accurate are the obtained results. The use of Monte Carlo codes and detailed anthropomorphic phantoms allows improving the quality of the results both for the in vivo measurements (calibration procedures) and for internal dosimetry evaluations (SAF coefficients). The availability of advanced code packages, that could be used in every laboratory dealing with radiation physics problems, should suggest the need a non extemporary use of these tools. Training initiatives at the European level are therefore to be encouraged in the field of Radiation Protection Dosimetry together with thematic workshops on specific computational dosimetry applications.

A tribute to Leonardo da Vinci 1452-1519