DAIKIN Internet remote control unit

Similar documents
Software Installation Guide. Version 1.1

AirPatrol WiFi Version 2 Full Manual V4.2

mcamview HD for ipad User Manual

AirPatrol WiFi Version 2 Full Manual. for ios V4.2

power port make sure the ac adapter is plugged into the correct port Make sure to include at the beginning.

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

Quick Start Guide 4/8/16-CH DVR.

300 Series Cube Wireless HD Surveillance Camera with Microphone. Installation Manual. Important! Ensure your NVR has the latest firmware!

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

IP116 Plus HD WiFi Camera

User Manual. For H.264 Cameras. Version 2.0.0

AirTouch 2 Zone Control System

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

User Manual DIR-850L. Wireless AC1200 Dual Band Gigabit Router.

Tranquil T7-HSA. Harmony Home Server

Heatmiser Netmonitor v3

ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV

Series SD-3PB Digital THERMOSTAT + TIMER

J60 Thin Client. User Guide

WHG325 V3.30. Secure WLAN Controller

TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 1.0.0

GXP 1620 USER MANUAL_Ver2.0.1

Citrix CloudBridge CB User Manual

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Quick Start Guide HGWOB-751

BACnet FF Configuration Wizard Guide

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

SP31. User Guide. January 2015 Document Revision 03

Bush Baby Stealth Fan Manual SKU: BBSFAN

Installation of the PCMeasure Movement Sensor (30114)

Troubleshooting. Connection Problems

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

IS-IR-WIFI-1 User Manual

Operation Guide CT32 ENGLISH

Quick Installation Guide

Home Control Gateway Troubleshooting

OK - Functions of the buttons. = "Arrow up" = ON / OFF. = Enter. = Temperature. ="Arrow down" = Preset time / Start time.

1. Introduction P Package Contents 1.

GXP 1400/1405 USER MANUAL

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Introduction. MyAir5 User Guide

Unified Office Gateway UMG Quick Installation Guide. Version: 1.0

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Smart Home System Kit

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

ThermoPad Reference Manual

HSPA+ WiFi Router with Voice

ETH002-2 Relays at 16A Technical Documentation

IP Camera. Apr 2012 V

Contents 1 Warnings, Cautions, and Notes Description Features... 1

INNOV.NET PTY LTD. User guide

Wireless Network Video Recorder

RGX COMMUNICATIONS GATEWAY

REEKBOX.com Thank you for choosing Shenzhen Sundeu Technology Please read the user manual carefully before using the product for any purpose

MIUFLY Body Camera User Guide

UTM Content Security Gateway CS-2001

Installation & Operations Manual

USER S MANUAL. DAS-G01 The Power of Tomorrow

Colour Touch Panel 3.5

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

ETH044-4 SSR (230VAC) and 4 Digital IO

OPERATION INSTRUCTIONS

BMR Operating Instructions

Enklov Security Camera Instruction. for video instruction

Delivered the Way Yo u Want

SG520 Series. Infrared Digital Scouting Camera User Manual. Page 1

Studio NDI. User Guide 1.0d

Operation 6035 ENGLISH PROG MENU

IP Camera. Mar 2012 V

EnCell Battery Cell Monitor

2 Mega-Pixel Fish-eye Panorama IP Camera ICA-HM830. Quick Installation Guide

GPS Cycle Computer Device. Quick Stat Guide

Millennium Simplicity Elite Parameter Points and Quirks

Xpander Desktop Elite Gen 3 User Guide

Connector for sensing cable

High Definition LCD Digital Signage Display

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Wifi Smart. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

On occasion, due to a failure or water damage it may become necessary to replace an APEX, APEX LITE, or APEX JR with another controller.

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER

How to Use Google Cloud Print

HD Pan/Tilt Wi-Fi Camera

Connect. Protect. Control. BS6425L. Need help?

Operation Guide. for the MultiPresenter Stick. DS1-MP10RX series. (Compatible with Ver. 1.01)

LEGUANG N900 Wireless Router Configuration Guide

Control systems. Efficient room control

MOD-RI Room Interface Modules with Modbus

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

TVB103C Thin Client. User Guide

SysLINK 1000/1500 Family Quick Start Guide

Connect. Protect. Control. BS6425L. Need help?

Version 13. Cisco to Meraki Firewall Upgrade Graphical Instructions

ACE Live on RSP: Installation Instructions

Poseidon 4002 MANUAL

Quick Start Guide HGWIP-818

Options Overview. February 6, Ben Newell

Transcription:

DAIKIN Internet remote control unit User s manual v1, May 2013 http://harizanov.com This is a part of an open source project that I have worked on and documented here. The Daikin Internet remote control unit emulates the ARC433** remote control (pictured to the left) that many modern Daikin split air conditioners use. It allows the user to remotely control the AC over the Internet, using the in-built web server, which you can access using your mobile phone, tablet or laptop from anywhere in the world. The unit includes a microsd card slot for firmware updates. Should there be newer firmware version, the user can save it to a SD card and the unit will automatically be re-flashed with it. No SD card is included, it is entirely optional to use this feature. A card of capacity 2GB or less is required as only FAT16 is supported. On-board is a TMP36 temperature sensor that can be used to check the room temperature. The temperature may be mounted on the PCB itself, but note that there may be heat transfer and hence false readings. In your setup, you

may wire the temperature sensor at a farther position from the board or calibrate the readings. Board dimensions are width 38mm depth 20mm and height 16mm. For the advanced users, JSON status string is available if the unit is queried at the default IP address, http://192.168.1.55/json it will return: {"state":"0","mode":"4","temp":"21","fan":"176","aux":"0","roomt":"22.9"} State has values 0 or 1 meaning off/on Mode has meaning 3 = Cool 4 = Heat 0 = AUTO 2 = DRY Temp shows the set temperature Fan shows the fan speed and has the following meanings: 176=Night mode 160=Auto 48=Speed 1 80=Speed 2 112=Speed 3 Aux shows the aux mode i.e. 0=Normal 1=Powerful 16=Silent Roomt is the room temperature in degrees Celsius detected by the on-board TMP36 temperature sensor JSON can be used for automation scripts, for example I use a PHP script to check outside temperature and decide on weather I need heating/cooling. Also, based on other criteria I may increase/decrease the set temperature during nights for better efficiency. The unit can take remote commands using query string, for example http://192.168.1.55/r?d=4&t=21&f=176&a=0&s=1 will set the AC in heat mode (see above for details), temperature 21, fan speed to night mode, normal mode and state ON. Note: Please do not use force when plugging in the microusb power plug: the jack is soldered on the board, not thru it and is fragile. To power-cycle the unit, rather disconnect from the mains and not from the microusb plug. Note: To access the Daikin Internet remote control from outside your local area network, you will need to set up your firewall accordingly. This brief document cannot elaborate on the possible firewall

configurations, please check how you can configure your firewall to allow incoming connections to be forwarded to the unit prior to purchasing. The unit supports only static IP address. The default IP configuration is: IP address: 192.168.1.55 Gateway: 192.168.1.1 DNS: 8.8.8.8 (Google s DNS, do not change unless you know what you are doing) Plug the unit to Ethernet connection and power up the unit. The unit check for firmware on the microsd card, and if it is not present will resume booting in few seconds. Upon starting, the on-board LED will go solid for about 20 seconds. Note: If for some reason you need to reset the settings to their default, you may briefly short using metal clip the jumper on the bottom of the IR board during the 20 seconds of solid LED at startup. If you do so, the LED will flash several times to indicate the board is reset. Power-cycle for the changes to apply. After the initial 20 seconds, the board will start and the LED will flash every second to indicate it is running. To access the unit s web server, you need to navigate to the default IP address: http://192.168.1.55 The UI will look differently depending if you chose to use JQuery or plain HTML in the HTML settings page. Pictured below are the two versions, the plain text version is more compatible, while the JQuery one is much more fancy and better to use with mobile phone for example.

The home page contains links to the possible pages. Below the menu will be the firmware version (FW), the uptime statistics and your unit s detected IP address (WAN). The Remote Control page allows for manual setting of the desired AC parameters:

The Schedule pages allow you to set up to 10 timers (0 to 9) that will transmit the desired setting at the defined time. This feature requires NTP settings to be configured properly so that the board can poll the time and date.

The network settings page is where you re-configure the IP address, gateway and DNS. The DNS is preset to Google s DNS, I advise you leave it so. f The NTP settings page is where you set the network time server, this is how the unit gets its time and date, needed for the scheduler. Time offset will adjust for the time zone, you may use positive or negative number.

The DynamicDNS page is where you configure for using Dyn.com s dynamic IP services. Username and password cannot exceed 10 chars.

The HTTP settings page allows you to set alternative HTTP web server port, valid ranges are 1-255. You can enable the JQuery UI from here too. For added security, you may enable HTTP authentication by setting a user and password (10 chars each max)