Leica Geosystems CS20 Data Controller CS - PXS8 CDMA Cellular Modem Setup for Verizon Wireless, Internet Connection for Network RTK Rover Surveying.

Similar documents
SiteMetrix Configuring RTK Corrections

Sokkia GSR 2700 ISX GPRS Configuration

Gateway 2.0 Cellular (P/N )

Altus APS3 Configure Rover for Radio, NTRIP or GPRS RTK Link

Topcon GRS-1 1 Receiver Field Preparation

MaCORS Quick Guide. Rover Configuration for Topcon GR 3 using Carlson SurvCE 2.x & Internal CDMA Modem

How to use Airlink Raven CDMA/GPRS Modems with Z-max?

ig8 as Network Base Date: 21 December 2017 By: Mark Silver, x16

APS-3 with FieldGenius Configuration Manual

Lab - Share a Printer in Windows 7 and Vista

SmartWorx Viva How to Record Static Observation Data On-Board GS Receivers Operating in Base Mode

Setup a VSN Survey Style Using Trimble Access (Bluetooth Phone)

SXBlue RTN. User s Guide. (for Windows Desktop and Windows Mobile 6.x) Revision Date: April 2012 (rev 1.0)

VR1600v (NBN FTTN & NBN FTTB) Windows 10

Setup a VSN Survey Style Using Trimble Access (MiFi Card)

Connect to Wireless, certificate install and setup Citrix Receiver

This how to guide should be used in conjunction with the following documentation:

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60, TS13 GNSS Sensors: GS18 T

CellRoute 3G. Fixed Wireless Terminal. Data Connectivity

Leica Viva CS & GS Driver Installation

APS-3 with Seismic Surveyor

Viva TPS. TS11/15 Total Stations Connect the CS Controller and TS15 with Bluetooth. October Summary

Banner Connected Data Solutions Web Service

How to achieve WIFI Client (Datalink) to receive RTK corrections from your Android or Windows device

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60. Release date 5 th March 2018

The SSID to use and the credentials required to be used are listed below for each type of account: SSID TO CREDENTIALS TO BE USED:

Connecting a GPS Rover to a Modem or Base Network

User Manual For TX204B/TX204G/TX306 Receivers

RediGate 400 Series Getting Started Guide

Security Management System SNMP Trap Interface

Leica Viva TPS October 2010

Scepter / Scepter II Getting Configured for Real Time Networks with an Internet Hot Spot

Leica Viva GS14 Designed for Performance

GE MDS, LLC. 175 Science Parkway, Rochester, NY USA Phone +1 (585) , FAX +1 (585) Web:

Setting up the Linksys WRT32X

TelkomInternet. APN Device Settings

Spectre RT3G Quick Start Guide and FAQ

Installing ImageTrends EMS Field Bridge

Eos Server User s Guide

Wireless Installation Instructions for Windows Vista

Orifice Flow Meter

Internet Access: Wireless WVU.Encrypted Network Connecting a Windows 7 Device

Now SMS/MMS Android Modem Quick Start Guide

Connecting to ehoundnet-fsa

Using the EN-2000 s Management System

ConnectPort X5 R Family Getting Started Guide

SBCC Web File System - Xythos

INVICTUS 3G/GPRS MODEM TECHNICAL INFORMATION

Instructions for connecting to the FDIBA Wireless Network (Windows Vista)

FOTA Update Procedure for NL-SW-LTE-S7588-V

[Outlook Configuration Guide]

USER S MANUAL v.2. Settop CellXtrem

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60. Release date 7 th June 2016

SBCSC Staff BYOD (bring your own device) Instructions: 08/11/2016

Leica Viva GS14 Designed for Performance

Access Connections 5.1 for Windows Vista: User Guide

Port Forwarding Setup (NB7)

Support Note. CenterPoint RTX Correction Service: Unlocking and Setting up the FM-750 Display and FM-1000 Integrated Display

The Preferences link will display the following user options. These may be changed by the user at any time.

Lab - Share Resources in Windows

On the left hand side of the screen, click on Setup Wizard and go through the Wizard.

REGISTERING YOUR BYOD DEVICE

GSR Reference Station Software

ADT Pulse Mobile App Settings

TCC College WiFi and Printer Setup 07/11/2018 College WiFi and Printer Setup Guide

WINDOWS NT 4.0 USER GUIDE

LAB: Configuring LEAP. Learning Objectives

5. A small dialog window appears; enter a new password twice (this is different from Dori!) and hit Go.

How to migrate to Chameleon

DI GHz Wireless Router

ios BYOD Wireless Instructions

I-Fly Wireless Broadband Router

Version 3.0 English. GRX1200 Series Getting Started

Electronic Prescribing of Controlled Substance (EPCS) Registration Single Provider Process

IS L02-MIGRATING TO SEP 12.1

Windows 95/98 Infoway Connection Instructions 1/4/2002; rev. 1/9/2002

INTRODUCTION...2 LOGGING IN...2 Homepage:...7 Current Location (1)...8 Account (2)...9 Equipment (3)...9 Services (4)...10 Billing (5)...

MHealth App For My Health Info with Newman Regional Health

Our Challenge : To manage an increasingly complex world!

1. QUICKSTART GUIDE TOOLBAR ADMIN LOWER TOOLBAR DEVICES CLIP DB MONITORING GSM SETTINGS...

MOZILLA FIREFOX (Version 52) EXTENDED SUPPORT RELEASE (ESR) Guidance for Windows PC Patient Portal End Users

Setting up the Wireless Communication on the Apollo Solar Cabinets

Windows 7 & 8.1 Driver Installation For Skywire (mpcie) Mini PCI Express Adapter Board

Step-by-Step Guide to Ansur Executive 3.0 With or without Electronic Signatures

Using the Leica Rover. A guide to locating And capturing locations Using the Leica GPS1200 Rover. Cleveland Utilities

IP Network Camera J2ME (Java) Application

BEFORE INSTALLATION: INSTALLATION:

X90 GPS X90GPS RTK. 1 -

DWL-G800AP. Check Your Package Contents. AirPlus Xtreme G TM

Leica RX1250 & TPS 1200 Robot

Leica Viva GS14 Designed for Performance

Benefits of Telecommunications Technology to GPS Users

Troubleshooting Guide DCM-300 Modem with Correction Services

Release 4.1. Description

capvpn Instructions for Windows

Multimedia 2006 Software User Manual

Skywire Development Kit User Manual

Digi Remote Manager. User Guide

GM862-GPS-OT User Guide

Advisor Advanced UltraSync Reference Manual

Transcription:

Leica Geosystems CS20 Data Controller CS - PXS8 CDMA Cellular Modem Setup for Verizon Wireless, Internet Connection for Network RTK Rover Surveying. Turn on the CS20 Data Controller, start the Leica Captivate Software, On the CS20 Data Controller, Select/tap > Fn Instrument, Select ( ) Use GS only, then Select/tap F1 OK button, User is return to Captivate Home screen, Select/tap Settings, PAGE 1

From the Settings panels, Select 1 Connections, From the Connections panel, Select/tap, 4 All other connections, PAGE 2

From the Connection Settings panel, Select CS connections, Select/tap F3 Edit button, From the Internet Connection panel, Select/tap F5 Device This is a VERY Important Step!!! Be sure the Check Mark is active, DO NOT Select Use user ID & Password [ ] Check Box in this panel, this is NOT for your NTRIP User ID & password, this User ID & password that could be required for the Cellular Service Provider. In the USA & Canada, a Username & password is no longer required for the Internet connection. PAGE 3

From the GPRS Internet Devices panel, Select the CS PXS8 CDMA Device, Select/tap F1 OK button, Select/tap F1 OK, button again The User is returned to the Connection Settings panel, From the Connection Settings panel, Select/tap F5 Info button, PAGE 4

From the CDMA Information panel, Select/tap the, F3 Reg button, The CS20 Data Controller will Register the Cinterion CDMA modem to the active Verizon Wireless Data Plan, assigned to the IMEI / MEID Number. Note, observe the Cinterion PXS8 Cellular Modem s MEID number, this is unique to this CS20 Data Controller and the CS Internal Cinterion CDMA modem device. This process may take a few minutes, be patient When the Verizon Wireless CDMA Activation is successful, a confirmation message will be scrolled across the Leica Captivate Home page status banner. Select F1 OK, then select F1 OK, again to return to Leica Captivate Home screen. Note: The End User must have already provided the CS20 Data Controller s Internal CS Modems IMEI number, the (Unique MEID Number), to Verizon Wireless, requetsed a Verizon Wireless Data Plan activation, Verizon Wireless Activates the Customer s Data Plan, sends an Over the Air activation over the Verizon Wireless Network, based on the CS20 s uniques MEID, (Mobile Electronic ID), or IMEI, (15-Digit Number) for the CS20 s Internal CS PXS8 Cellular Data Modem. PAGE 5

After Verizon Wireless has sent the Over the Air Activation, through the Leica Captivate software on the CS20 Data Controller, the End User REG, or Registers the CS20 s Verizon Wireless Data Service on the CS Internal Cinterion PXS8 CDMA modem. From the Leica Captivate Home screen, Note/observe the @ Symbol on the Top Row Task Bar, This is a visual indication the CS20 Data Controller s Internal CS Cinterion PXS8 CDMA modem is Connected to the Internet via the Verizon Wireless Cellular Network PAGE 6

Note/observe the Connectivity Check list, Top to Bottom, all Connectivity settings are OK, working as they should be The End User can now configure the Settings > Connections > RTK Rover Wizard, Configure the NTRIP Server/Mount Point details, consisting of the NTRIP Server Name, the IP Address, (or Domain Name), the TCP/IP Port Number, and the User s NTRIP Username & Password Credentials, Start the RTK Data Stream, then begin the Network RTK Survey. NOTES: The CS20 Data Controller CS PXS8 CDMA Modem IMEI Number: Provide the CS20 Data Controller s CS PXS8 CDMA Modem IMEI Number to Verizon Wireless retain a copy for future reference. PAGE 7