DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

Similar documents
DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

Acquisition and Evaluation, 2825A... TEL: Measuring Instrument Control and Configuration via Communication Interfaces RS-232C 501

DAQ-System for DynoWare

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

System Requirements Operating System Windows XP, Windows Vista >512 MB RAM CPU speed >2,5 GHz CD-ROM drive USB or parallel interface Important

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

Instruction Manual DynoWare Type 2825A

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

NextView 4 Software for Data Acquisition and Analysis

Part Numbers SNAP-IT-EMU1

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

...the precision signal conditioning company. Combustion Analyzer Series. Automotive Research & Development.

Overview DT Measure Foundry is a drag-anddrop test and measurement application builder designed to give you top performance

SCP for Plastics Processing

Quick Start Guide. Cole-Parmer USB-based Data Acquisition Software

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

catman Data Acquisition and Analysis software Special features Data sheet Generic Modules Application Modules

Chapter 6 Data Acquisition and Spectral Analysis System high-speed digitizer card for acquiring time-domain data. The digitizer is used in

DT Measure Foundry TM is a powerful software package designed for test and measurement,

HCC-F Software. Honigmann Computer Control - Precision Friction Meter

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

DT9828. USB Powered Thermocouple Measurement Module. Key Features: Analog Input Channels

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

maxymos BL Electronics & Software XY Monitor for Good/Bad Evaluation of Curves Type 5867B...

Logger Pro 3. Quick Reference

4-component Dynamometer (RCD)

Measurement Equipment for Future Transient Recorder TransCom-CompactX MF Instruments GmbH

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

data recorder Powerful, portable, intuitive to use Data acquisition with Genesis HighSpeed

±500 V Isolation Protects Your Data. Sample Rate. 16 bits ±1.25 V, ±2.5 V, ±5 V, ±10 V 100 ks/s 16 2

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

Hand-Held Thermometer Model CTH 6200

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

Data acquisition hardware

vsignalyzer Product Information

DT9828. Low-Cost, Isolated, Thermocouple Measurement Module. Overview. Key Features. Supported Operating Systems

MEphisto Scope 1 A D. Prozessor-Steuerung. Interner Daten-/Steuer-Bus. Digital I/O-Teil

Engineering Data Management (EDM) Software

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

EXPERIMETRIA LTD. S.P.E.L. Advanced Software Family. Brochure. Isosys Kymograph.

Agilent U2600A Series USB Isolated Digital I/O Devices. Data Sheet

BE/EE189 Design and Construction of Biodevices Lecture 5. BE/EE189 Design and Construction of Biodevices - Caltech

A variety of ECONseries modules provide economical yet flexible solutions

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Features Summary. Input Ranges

Electromechanical Systems Simulation Software (LVSIM -EMS)

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

Software Package Installation Instructions

Application The standard SmartCrash segment is used vertically in the automotive industry and in vehicle crash test centers, and horizontally in tower

Software. Supported Controllers F4T and EZ-ZONE RM. Operating Requirements. Page. COMPOSER With INTUITION EZ-ZONE Configurator

Welcome Subject to change without prior notice / Siemens AG, 2009

MicroBench MB-500A. Live Logic Logic source pattern generator Logic analyzer Arbitrary waveform generator Protocol interactive test

VIBbox 64-Channel Sound & Vibration Solution

PowerView for the EnergyPro

Tender No Technical Specification for Digital Image Correlation (DIC) System. Commodity Description

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

METRAwin 10. Parameters Configuring and Analysis Software for Electrical Measuring Instruments. Operating Instructions Version 1/09.

AKELA Vector Network Analyzer (VNA) Quick Start Guide

Practical and Compact!

User Manual for Portable National Instruments Board, Bridge Amplifiers, and VI Logger Software

Hand-held thermometer Model CTH6200

Characteristics and functioning

Flexible configuration of user interfaces and displays. Easy generation of protocol and presentation sheets

Ultra-Accurate Measurement for Temperature and Voltage

Data Acquisition Software and Hardware. Demonstration Guide. For: NetDAQ Logger, Hydra Logger, and Trend Link for Fluke V3.1

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

40 to 150 MHz digital and mixed oscilloscopes

TraNET FE Data Acquisition Instrument

ArbExpress AXW100 Waveform Creation and Editing Tool for Tektronix AWG/AFG Installation Manual

User s Manual. CW500Viewer IM CW500-61EN. 2nd Edition

6224 Ethernet-Based Strain Measurement Module

6220 Ethernet-Based Voltage Measurement Module

Hand-held thermometer Model CTH6200

GL500A Application Manual

DASYLab Data Acquisition System Laboratory

AUTOMOTIVE DYNAMOMETER HARDWARE AND SOFTWARE

Portable and Online Condition Monitoring System

Agilent U2722A USB Modular Source Measure Unit. Data Sheet

Hands-on Lab 2: LabVIEW NI-DAQ Basics 2

Automotive Dynamometer

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

Programmable Switching DC Power Supply

ThinkRF R5500. Real-Time Spectrum Analyzer 9 khz to 8 GHz / 18 GHz / 27 GHz. Technical Data Sheet Preliminary

41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet: Fax: +39-(0)

6220 Ethernet-Based Voltage Measurement Module

Testing and Diagnostics

DIAGNOSTICS PN# / / FSP

NI Technical Symposium ni.com

840CT Battery Discharger &Capacity Tester

DT MS/s High-Speed, Isolated Simultaneous USB Data Acquisition Module. Overview. Key Features. Bandwidth of the DT9862

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2)

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

Ultra-Accurate Measurement for Temperature and Voltage

CompuScope 1602 product introduction

DT Channel Analog Input USB DAQ Module. Key Features:

Soft-Engine - Data store software: Version 8

English. Software and System Training. Data Acquisition. Keep for future use. Companies / Brands of GHM

CMC-99 (RS ) multichannel CONTROLLERS data recorders

Transcription:

Electronics & Software DynoWare Software for Data Acquisition and Evaluation 2825A... Kistler DynoWare is a universal and easy to use software, which is particularly suitable for force measurements with dynamometers or single and multi-component force sensors. Simple operation Configuration and control of Kistler measuring instruments via USB, RS-232C, Ethernet or IEEE-488 Useful signal evaluation and calculation functions Simultaneous recording of up to 28 measuring channels depending on DAQ system Realtime visualization of measured curves The software is ideal for the acquisition and evaluation of physical measurands Description For signal analysis, DynoWare offers the technician realtime visualization of the measured curves together with useful calculation and graphics functions. Apart from simple configuration of the most important measuring instruments, this software supports individual documentation of the measurement, along with storage of configuration data and measured data. The signal evaluation also enables compensation of undesirable signal drift due, for example, to undue influence of temperature. DynoWare supports Kistler's DAQ System 5697A as well as the LabAmp System 5167A. Application DynoWare is the data acquisition software of choice for cutting force measurement. It supports both stationary and rotary measuring systems from Kistler. However, DynoWare can also be used for any reaction force measurements or crash measurements with Kistler multicomponent dynamometers. At the same time, the measured data from signal amplifiers of other manufacturers can also be measured and evaluated. Technical Data Data Acquisition Cards Supported 5697A: USB DAQ System Connection: USB 2.0 Number of measuring channels: 28 1), analog, single ended Resolution: 16 Bit Measuring ranges: ±0,1 V, ±0,2 V, ±0,5 V, ±1 V, ±2 V, ±5 V, ±10 V Sampling rate: 1 Channel active: 1 MS/s 8 Channels active: 125 ks/s 16 Channels active: 62,5 ks/s 5167A: LabAmp Measurement System Connection: Ethernet Number of measuring channels: up to 16 channels from different devices 2) Resolution: 24 Bit Measuring ranges: 100 1 000 000 pc Sampling rate: 100kS/s simultaneous acquisition 1) DynoWare 2825A as well as Update 2825E allow to control one charge amplifier only. DAQ system 5697 is capable to acquire 28 channels maximum. 2) DynoWare 2825A as well as Update 2825E allow to control multiple charge amplifier of LabAmp Family 5167A or for dynamic signals and voltage 5165A. Dynoware is able to acquire in overall 16 channels from different LabAmps in parallel. Page 1/5

DynoWare Software for Data Acquisition and Evaluation, 2825A... Measuring Instrument Control and Configuration via Communication Interfaces RS-232C 5011Bx2, 5015A..., 5017..., 5018A..., 5019..., 5070A, 5080A..., 5223..., 5237..., IEEE-488 5011Bx1, 5015Ax1xx, 5070Axxxx1 USB 2.0 5018A..., 5080A... Ethernet 5167A, (5165A ) Triggering Analog, digital and by Keyboard Tools Voltmeter function Oscilloscope function Documentation of the Measurement Each measurement can be individually documented. Storage of measurement and configuration data with or without remarks Export of measured data and ASCII format (.txt) or (.csv) for Excel, DIAdem, LabVIEW, Matlab, etc. Printer Printing of test records and configuration data is supported by Windows Signal Analysis Within a measuring window Averaging Minimum and maximum Values Integral RMS FFT Smoothing/filtering Moving mean value Moving median value Filters: High pass, low pass, band pass and band stop Compensation of signal drift Example of a Test Record Graphics Functions Measured data represented on one or more graphs Display as y(t) and y(x) graphs Display of numeric Values Cursor function Zoom function Polar plot Display of FFT analysis Calculation Functions Multi-component force-moment calculation Calculation of radial and tangential forces with rotating cutting force dynamometer 9123 /24, 9170.../71... Mathematical functions Page 2/5

DynoWare Software for Data Acquisition and Evaluation, 2825A... Cable Concept for DynoWare 2825A with DAQ System 5697A Signal Conditioner Measuring Signal Connecting Cable A/D Acquisition Card 5070 5080... 3) D-Sub pos. 15 pole 1700A111A2 D-Sub neg. 15 pole 5697A 5011 5015 5018... 5080... other products 8x BNC pos. 1700A113A2 D-Sub neg. 15 pole D-Sub pos. 15 pole 3) Cable 1700A111A2 can be used in addition with DAQ system 5697A, regardless of summed or output signals being acquired. Page 3/5

DynoWare Software for Data Acquisition and Evaluation, 2825A... Interface Cables Signal Conditioner RS-232C Interface Cable (Null Modem) 5011Bx2 D-Sub pos. 25 pole 1475A3 D-Sub neg. 9 pole 3 m 5015 5018... 5070 5080... D-Sub pos. 9 pole 1200A27 5 m D-Sub neg. 9 pole Typical Measuring Chain with DAQ System 5697A1 Dynamometer High resistant cable Charge amplifier Connecting cable DAQ system 9129AA 1677A5 5070A 1700A111A2 5697A1 1200A27 Notebook (customer) with DynoWare Typical Measuring Chain with DAQ System 5697A1 Dynamometer High resistant cable Charge amplifier 9129AA 1677A5 5167A Notebook (customer) with DynoWare Page 4/5

DynoWare Software for Data Acquisition and Evaluation, 2825A... System Requirements Microsoft Windows 7 / 8 / 10 Acrobat Reader for reading the PDF Instruction Manual Pentium-class PC or 100% compatible computer (1 GHz or higher recommended) 512 MB of RAM (1GB recommended) Super VGA monitor with the following settings: Screen resolution set to at least 800x600, small fonts selected Disk (free) space required: 1 GB in the target directory for data storage and software installation Microsoft compatible mouse 1 USB port For 5167A: 1 Ethernet port 100Mbit A color printer is recommended for creating hard copies of graphs Optional Accessories DAQ system, USB 5697A... Charge Amplifier System 5167A Charge Amplifier System 5165A Connecting cable 1500B15 Connecting cable 1500A67 Connecting cable 1700A111A2 Connecting cable 1700A113A2 Interface cable 1200A27 Interface cable 1475A3 USB/RS-232C converter 2867 Ordering Key Scope of Delivery Including Accessories DynoWare Complete Version 2825A-03-2 Runtime license key for USB interface (HASP) DynoWare Update Version DynoWare Demo Version DAQ-System for DynoWare Complete version HASP license key, 2825A USB 2.0 DAQ-box USB cable, length 1,8 m Universal AC/DC adapter 100... 240 V DAQ-System for DynoWare Update version, 2825E USB 2.0 DAQ-box USB cable, length 1,8 m Universal AC/DC adapter 100... 240 V 2825E-03-0 2825D-03-0 5697A1 5697A2 Windows is a registered trade mark of Microsoft Corporation. Adobe Reader is a registered trade mark of Adobe. LabAmp 5167A with DynoWare Complete system LabAmp 5167Ax1, 4 or 8 channel version DynoWare software on CD ROM, 2825A Ethernet cable, l = 2m Power supply 24V Quick start guide 5167Ax1DK Page 5/5