Pre-programmed room controller with display and communication

Similar documents
RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Pre-programmed room controller with display and communication

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

STRA-17 Room controller. Installation and maintenance manual. Content

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

Room controller STRA-17

RCF-230CTD. Built-in or external sensor The controller has a built-in sensor. Alternatively, the input for an external PT1000-sensor can be used.

WE TAKE BUILDING AUTOMATION PERSONALLY MANUAL RCF

OP10. Pre-programmed, configurable controller for simple applications

EXOcompact. Third generation freely programmable controllers

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

AIAS. Technical description

Constant & Variable air volume controllers

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

HLS34 Modbus FCU/VAV Controllers installation instructions

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER

Field selectable application type and room module series, via dip-switches on controller

Corrigo E. Version 3.0 (ventilation), 3.0 (heating), 1.1 (boiler). Controllers for heating, boiler and ventilation applications in buildings.

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

FCU-MULTI Modbus Fan Coil Unit Controller

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

TAC Xenta 121-FC Programmable Fan Coil Application

Communicative controller for VAV systems

EXOcompact. Freely programmable controller

Semi Flush-mount Room Temperature Controllers with LCD

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controllers

Room Temperature Controller

Room Temperature Controller

SE7600E Series Application Guide

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

O P T I G O R E A D Y - S T E A D Y - G O Optigo OP5U Manual Copyright AB Regin, Sweden, 2012

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

Semi flush-mounted room temperature controllers with LCD

Non-communicating room controllers

Technical data sheet

SE7600E Series Application Guide

Temperature controller Ducted systems

Universal Controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TAC Xenta 121-HP Programmable Heat Pump Application

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

MOD-RI Room Interface Modules with Modbus

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

EY-RU : Room operating unit, ecounit

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Small distributed I/O module

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Non-communicating room controllers

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

TC-8900 Controller Units with PM-8900 Power Modules

EY-EM : Remote I/O module, ecolink

ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV

Specification Sheet For electronically commutated motors

Measure & Control Temperature & CO2 levels with analog & digital I/O

RXTP ROOM TEMPERATURE

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

CCM-204 MULTI-PURPOSE TEMPERATURE CONTROLLER

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

VZ7000 Series. BACnet Commercial Zoning System

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

RXTH DUAL ROOM SENSOR / SWITCH

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UCU Room Display. Operation Modes. Features. Applications DATASHEET

EY-RU : Room operating unit, ecounit

SE8300 Room Controller

Application program: description and examples

EY-RU 355: Room operating unit, ecounit355

EC-PU4. Processor unit with 4 communication ports

SEZ7000 Series. Wireless Commercial Zoning System

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Products for HVAC applications in Building Automation CATALOGUE ppm -9 C +20 C

Control systems. Efficient room control

R7426A TEMPERATURE CONTROLLER WITHOUT REAL-TIME CLOCK. MicroniK 200. Order Numbers

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

LLR-MOD Modbus Light Level and Occupancy Sensor

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface

EXOcompact Third Generation Manual

BACnet Product Overview

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS INTELLIGENT TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

7-day room temperature controller

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

Room unit with PPS2 interface

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Andover ContinuumTM. b3850 Series Terminal Controllers

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

5 year. Controllers for comfortable indoor climate and energy efficiency

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RWD68U Universal Controller

Transcription:

revision 10 2017 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling and CO 2 in a zone control system. RC-C3DOC is a room controller in the Regio series. It has display and communication via RS485 (Modbus, BACnet or EXOline) for systems integration. Regio Regio is an extensive range of controllers for control of heating and cooling. The controllers are divided into three different series; Mini, Midi and Maxi. Mini consists of pre-programmed, stand-alone controllers. Maxi consists of freely programmable controllers with communication. The Midi controllers, of which RC-C3DOC is a part, consists of pre-programmed controllers with communication. Applications The Regio controllers are suitable for use in buildings requiring optimum comfort and reduced energy consumption, such as offices, schools, shopping centres, airports, hotels and hospitals etc. See application examples on page 4. Sensor The controller has a built-in room temperature sensor. An external sensor for room temperature, change-over or supply air temperature limitation can also be connected (PT1000). There is also an input for CO 2 sensors. Short facts about RC-C3DOC Communication via RS485 (Modbus, BACnet or EXOline) Quick and simple configuration via Regio tool Easy installation On/Off or 0...10 V control Backlit display Input for occupancy detector, window contact, condensation sensor, CO 2 detector, or change-over function Supply air temperature limitation Easy to install The modular design, featuring a separate bottom plate for wiring, makes the entire Regio range of controllers easy to install and commission. The bottom plate can be put into place before the electronics are installed. Mounting takes place directly on the wall or on an electrical connection box. Actuators RC-C3DOC can control 0...10 V DC valve actuators and/or 24 V AC thermal actuators or On/Off actuators with spring return and dampers. Flexibility with communication RC-C3DOC can be connected to a central SCADA system via RS485 (EXOline, BACnet or Modbus) and configured for a specific application using the free configuration software Regio tool. Read more about Regio tool on page 4.

Display handling The display has the following indications: Setpoint Indoor / outdoor temp. OFF:The controller is turned off Forced ventilation STANDBY: Standby indication SERVICE: Parameter settings The buttons on the controller enables easy setting of parameter values using a parameter menu shown in the display. The parameter values are changed with the INCREASE and DECREASE buttons and changes confirmed with the Occupancy button. Occupancy button Changeable value INCREASE DECREASE Occupancy indication Current room temperature in C to one decimal point Open window COOL/HEAT: Shows if the unit controls according to the heating or cooling setpoint To prevent unauthorised users from making changes to the settings, it is possible to block button functionality. Parameter menu access may also be blocked. Control modes RC-C3DOC can be configured for different control modes/control sequences: Heating Heating/Heating Heating/Cooling via change-over Heating/Cooling Heating/Cooling with VAV-control and forced supply air function Heating/Cooling with VAV-control Cooling Cooling/Cooling Heating/Cooling/VAV Change-over with VAV function Operating modes There are five different operating modes: Off, Unoccupied, Stand-by, Occupied and Bypass. Occupied is the preset operating mode. It can be set to Stand-by using the parameter menu in the display. The operating modes can be activated via a central command, an occupancy detector or the Occupancy button. Off: Heating and cooling are disconnected. However, frost protection is still active (factory setting (FS))=8 C). This mode is activated if a window is opened. Unoccupied: The room in which the controller is placed is not used for a extended time period, such as during holidays or long weekends. Both heating and cooling are kept within a temperature interval with configurable min/ max temperatures (FS min=15 C, max=30 C). Stand-by: The room is in an energy saving mode and is not used at the moment. This can, for instance, be during nights, weekends and evenings. The controller stands by to change operating mode to Occupied if presence is detected. Both heating and cooling are kept within a temperature interval with configurable min/max temperatures (FS min=15 C, max=30 C). Occupied: The room is in use and a comfort mode is activated. The controller maintains the temperature around a heating setpoint (FS=22 C) and a cooling setpoint (FS=24 C). Bypass: The temperature in the room is controlled in the same way as in the Occupied operating mode. The output for forced ventilation is also active. This operating mode is useful for instance in conference rooms, where many people are present at the same time for a certain period of time. When Bypass has been activated by pressing the occupancy button, the controller will automatically return to its preset operating mode (Occupied or Stand-by) after a configurable time has elapsed (FS=2 hours). If an occupancy detector is used, the controller will automatically return to its preset operating mode if no occupancy is detected for 10 minutes. Bypass can also be activated if CO 2 levels are high. CO 2 control A CO 2 sensor is connected to AI2. In control modes where VAV (Variable Air Volume) has been selected, the damper will be affected by the CO 2 levels (UO2/UO3, depending on control mode). If the CO 2 concentration rises, the damper will open to increase air volume regardless of controller temperature requirements. The damper starts opening when the CO 2 levels exceed CO 2 level for starting opening damper and is entirely open at CO 2 level for fully opened damper. Occupancy detector By connecting an occupancy detector, RC-C3DOC can switch between the preset operating mode for presence (Bypass or Occupied) and its preset operating mode. This way, the temperature is controlled from requirement, making it possible to save energy while maintaining the temperature at a comfortable level. 2

The occupancy button Pressing the occupancy button for less than 5 seconds when the controller is in its preset operating mode will cause it to change to operating mode Bypass. Pressing the button for less than 5 seconds when the controller is in Bypass mode will change its operating mode to the preset operating mode If the occupancy button is depressed for more than 5 seconds will change the controller s operating mode to Shutdown (Off/Unoccupied) regardless of its current operating mode. Regio tool or the display enables selecting which operating mode, Off or Unoccupied, should be activated on Shutdown (FS=Unoccupied). If the occupancy button is depressed for less than 5 seconds when in Shutdown mode, the controller will return to Bypass. EC fan control Control of an EC fan can be set using Regio tool. It is possible to select whether the fan should run in Heating, Cooling or both Heating and Cooling. Fan boost function If there is a great difference between the room setpoint and the current room temperature, or if one simply wishes to hear the fan start, a boost function can be activated to make the fan run at top speed for a short start-up duration. Fan kickstart When using today s energy-saving EC fans, there is always a risk the fan will not start due to the low control voltage preventing the fan from exceeding its starting torque. The fan will then remain at a standstill while power still flows through it, which may give rise to damage. To prevent this, a fan kickstart function can be activated. The fan output will then be set to 100 % for a set time (1...10 s) when the fan is set to run at its lowest speed when starting from an off position. In this way, the starting torque is exceeded. After the set time has elapsed, the fan will return to its original speed. Change-over function RC-C3DOC has an input for change-over that automatically resets output UO1 to operate with heating or cooling function. The input can be connected to sensors of type PT1000, with the sensor mounted so that it senses the temperature of the coil supply pipe. As long as the heating valve is more than 20 % open, or each time a valve exercise takes place, the difference between the media and room temperature is calculated. The control mode is then changed based on the temperature difference. Optionally, a potential-free contact can be used. When the contact is open, the controller will operate using the heating function, and when closed using the cooling function. Forced ventilation Regio has a built-in function for forced ventilation. If the occupancy operating mode has been configured for this function, a closing of the digital occupancy detector input will set the controller to Bypass mode and activate the output for forced ventilation (UO3). This can for instance be used to open a damper. The function is terminated when the settable forcing interval has run out. Flow calculation AI2 can be configured to act as an input for flow calculation. A flow is then set corresponding to 0 V as well as one corresponding to 10 V, and flow is then calculated linearly between these two endpoints. Setpoint adjustment When in mode Occupied, the controller operates using a heating setpoint (FS=22 C) or a cooling setpoint (FS=24 C) that can be changed using the INCREASE and DECREASE buttons. Pressing INCREASE will increase the current setpoint by 0.5 C per press until the maximum offset (FI=+3 C) has been reached. Pressing DECREASE will decrease the current setpoint by 0.5 C per press until the maximum offset (FI=-3 C) has been reached. Switching between heating and cooling setpoints takes place automatically in the controller depending on heating or cooling requirements. Built-in safety functions RC-C3DOC has an input for a condensation sensor to detect moisture accumulation. If detected, the cooling circuit will be stopped. The controller also has frost protection. This prevents frost damages by ensuring that the room temperature does not drop below 8 C when the controller is in mode Off. Lighting control UO3 can be set to control lighting. When occupancy is detected, lighting is activated, remaining switched on for as long as someone is in the room. The Standby/ Occupied/Bypass operating modes are active as usual. If the controller is in Off-mode (Off/Unoccupied), the occupancy input will be active if UO3 is configured for lighting control. Supply air temperature limitation AI1 can be configured for use with a supply air temperature limitation sensor. A room controller will then work together with a supply air temperature controller using cascade control, resulting in a calculated supply air temperature maintaining the room temperature setpoint. It is possible to set individual min/max limitation setpoints for heating and cooling. Settable temperature range: 10 50 C. 3

Actuator exercise All actuators are exercised, regardless of type or model. The exercise takes place at intervals, settable in hours (FS=23 hours interval). An opening signal is sent to the actuator for as long time as its configured run time. A closing signal is then sent for an equal amount of time, after which the exercise is completed. Actuator exercise is switched off if the interval is set to 0. Configuration and supervision using Regio tool RC-C3DOC is pre-programmed upon delivery, but can be configured using Regio tool. Regio tool is a PC-based program that makes it possible to configure and supervise an installation and change its settings using a comprehensive user interface. The program can be downloaded free of charge from Regin s website www.regincontrols.com. Application examples Heating/Cooling/VAV Condensation sensor Temperature sensor Modbus EXOline BACnet RS485 TCP/IP EX8282 RS485 RC-C... EXOscada HUB Presence detector Window switch CO 2 sensor SCADA TCP/IP EX8282 EX8282 RS485 RC-C... RC-C... 4

Technical data Supply voltage Internal consumption Ambient temperature Storage temperature Ambient humidity Protection class Communication Modbus BACnet Communication speed Display Built-in temperature sensor Material, casing Weight Colour Inputs External room sensor or supply air temperature limitation sensor Change-over alt. potential-free contact Occupancy detector Condensation sensor, window contact Outputs Valve actuator (0...10 V), thermal actuator(on/off pulsing) or On/Off actuator (UO1, UO2) Valve actuator Thermal actuator On/Off actuator Output Damper actuator, EC fan or lighting control (UO3) Forced ventilation Output 18...30 V AC, 50...60 Hz 2.5 VA 0...50 C -20...+70 C Max 90 % RH IP20 RS485 (EXOline or Modbus with automatic detection/change-over, or BACnet) 8 bits, 1 or 2 stop bits. Odd, even (FS) or no parity. MS/TP 9600, 19200, 38400 bps (EXOline, Modbus and BACnet) or 76800 bps (BACnet only) Backlit LCD NTC type, measuring range 0...50 C, accuracy ±0.5 C at 15...30 C Polycarbonate, PC 110g White RAL9003 Available in other colours on inquiry, contact Regin for more information This product is CE marked. More information is available at www.regincontrols.com PT1000 sensor, 0 50 C. Suitable sensors are Regin s TG-R5/PT1000, TG-UH/PT1000 and TG-A1/PT1000. PT1000 sensor, 0 100 C. Suitable sensor is Regin s TG-A1/PT1000. Closing potential-free contact. Suitable occupancy detector is Regin s IR24-P. Regin s condensation sensor KG-A/1 resp. potential-free contact 2 outputs 0 10 V, max 5 ma 24 V AC, max 2.0 A (time-proportional pulse output signal) 24 V AC, Max. 2.0 A Heating, cooling or VAV (damper) 1 output 24 V AC, max. 2.0 A, alt. 0...10 V, max. 5 ma Forced ventilation, alt. EC fan or damper following Heating/Cooling in sequence alt. lighting control (on/off) Exercise FS=23 hours interval Terminal blocks Lift type for max cable cross-section 2.1 mm 2 Setpoint settings via Regio tool or in display Basic heating setpoint 5...40 C Basic cooling setpoint 5...50 C Setpoint displacement ±0...10 C (FI=±3 C) 5

Wiring Terminal Designation Operation 10 G Supply voltage 24 V AC 11 G0 Supply voltage 0 V 12-14 No function 20 GDO 24 V AC out common for DO. 21 G0 0 V common for UO (if using 0...10 V actuators) 22 UO3 Damper output for forced ventilation (24 V AC), alt. EC fan (0...10 V DC), alt. damper following heating/cooling in sequence, alt. lighting control (on/off) 23 UO1 Output for 0...10 V valve actuator alt. thermal actuator alt. On/Off actuator, heating (FS), cooling or heating/cooling via change-over. 24 UO2 Output for 0...10 V valve actuator/damper actuator alt. thermal actuator alt. On/Off actuators, heating or cooling (FS). 30 AI1 Input for external sensor, alt. change-over sensor, alt. supply air temperature limitation sensor 31 A12 Input for CO 2 sensor, 0...10 V DC, alt. air speed 32 DI1 Input for occupancy detector, alt. window switch, alt. digital change-over 33 DI2/CI Input for condensation sensor KG-A/1 alt. window switch alt. digital change-over 40 +C 24 V DC out common for UI and DI 41 AGnd Analogue ground 42 A RS485-communication A 43 B RS485 communication B Dimensions 60 68 95 28 mm Product documentation Document Regio Midi manual Installation instruction Regio RC-C3DOC Product sheet TG-R4/PT1000, TG-R5/PT... Product sheet TG-UH/PT... Product sheet CO2RT (-D) Product sheet IR24-P Instruction IR24-P Product sheet KG-A/1 Type Manual for the controllers from the Regio Midi series Installation instruction for Regio RC-C3DOC Information on suitable sensors for RC-C3DOC Information on suitable occupancy detector for RC-C3DOC Information about condensation sensors for the Regio controllers The documents can be downloaded from www.regincontrols.com. Head office Sweden Phone: +46 31 720 02 00 Web: www.regincontrols.com E-mail: info@regin.se