EN TECHNICA MANUA Door-entry phone art. 78W
Warning Intended use This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and in public buildings or buildings used by the public. Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the manuals / instruction sheets supplied with those products. Wires Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual. We advise against running the system wires through the same duct as the power cables (0V or higher). Safe usage To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets make sure the system created using Comelit products has not been tampered with / damaged. Maintenance Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the manuals / instruction sheets. Any repair work must be carried out for the products themselves, exclusively by Comelit Group S.p.A., for systems, by qualified technical personnel. Disclaimer Comelit Group S.p.A. does not assume any responsibility for any usage other than the intended use non-observance of the indications and warnings contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual / instruction sheet at any time and without prior notice Table of contents Warning... Description... Technical characteristics... 4 Installation... 5 Connections... 6 Connection to the video entry riser and the floor door call button...6 Branched connection to the video entry riser from the internal video unit...6 Connection to the door entry riser and the floor door call button...6 rogramming... 7 DI-switch programming table... 7 EXAME: dip switch setting for code 00...7
Description MINI series door-entry phone complete with key button, button and a -position ringtone / rivacy selector, suitable for use in audio systems with power supply unit 0 and audio-video systems with power supply units 09, 0, 4888C. Dimensions: 05 x 90 x 8 mm.. 4.. 5. 6.. oudspeaker. Audio hook Do not press and hold the audio hook while the handset is lifted. -position ringtone / rivacy selector: High position: Maximum ringtone volume Middle position: Medium ringtone volume ow position: rivacy activation (rivacy service means exclusion of the call ringtone from the external unit and switchboard) 4. Red indicator signaling: rivacy service active 5. button for switchboard call / Generic actuator 6. Key button 7. Terminal block M: CF CF floor door call input BUS line connection 8. DI-switch for setting user code (See DI-switch programming table ) 9. Bell / rivacy selector 0. J jumper for selecting the Generic actuator / Switchboard call function of button A Generic Actuator C Switchboard. Handset connector
Technical characteristics MAIN FEATURES System SimplebusTop (S e S) Audio system Yes Audio/video system Yes Wall-mounted Yes Desk base-mounted Yes Hands-free function - Induction loop function - roduct color White Total buttons ED signaling No FUNCTIS Actuator control function Yes Switchboard call function Yes anic call - General intercom call - Selective intercom call - rivacy function Yes Doctor - Floor door call function Yes Electronic bell Yes Customisable ringtone - SETTINGS oudspeaker volume control Ringtone volume control Yes Yes TECHNICA SECIFICATIS Supply voltage 5 Vdc ower consumption stand-by (ma) 0,5 0, 70 In called absorption (ma) 5 0 In communication absorption (ma) 0 Microphone Ø 9,6 x 6,9 mm Speaker Ø 0,50 mm ; Max Imput ower 0,5W I Rating 0 Operating temperature ( C) -5 +40 Operating humidity (%) 5-75 Dimensions ( x H x D) mm 05 x 90 x 8 roduct weight (Kg) 0,57 Clamps,,CF,CF 4
D C B S SW J CF CF S SW J CF CF max 7cm CACK! CACK! 6 5 4 cm 60 cm 0 A mm 90 mm 05 7 5 Installation
4 5 6 Connections Connection to the video entry riser and the floor door call button IN IN 4/C M M C F C F 78W 09 / 0 /4888C Branched connection to the video entry riser from the internal video unit C C F F 67W 67W C F C F 78W C F C F 78W 6700W 670W 670B IN IN 4/C M M M M IN IN 4/C 09 / 0 /4888C Connection to the door entry riser and the floor door call button Audio-only systems C F C F 78W 0 0 m MAX - Use shielded cable for the connection and do not route the cables in the vicinity of heavy inductive loads or power supply cables (0V / 400V). Where multiple door-entry phones or monitor backplates have the same user code, connect the CF button on one only; all the devices will ring simultaneously. 6
rogramming Each door-entry phone in the system is identified by means of its own code. This code must be set using the on the phone card. The user code must be set according to the corresponding information provided in the programming table. Coding can take place at any time, even without a power supply. DI-switch programming table,,,4,5 6,,4,5,6 9,,4,5,7,4,5,6,7 5,,,5,8 8,,5,6,8,,5,7,8 6 6,,4,5,6 9,4,5,7,4,5,6,7 5 4,5,8 8,,5,6,8,5,7,8,,6 6,,,4,5,6 9,,4,5,7,,4,5,6,7 5,4,5,8 8,,,5,6,8,,5,7,8 4 4,6 64 7 94,,4,5,7 4,4,5,6,7 54,4,5,8 84 4,5,6,8 4,,5,7,8 5, 5,,6 65,7 95,,,4,5,7 5,,4,5,6,7 55,,4,5,8 85,4,5,6,8 5,,,5,7,8 6, 6,6 66,7 96 6,7 6,,4,5,6,7 56,4,5,8 86,4,5,6,8 6 4,5,7,8 7,, 7,,6 67,,7 97,6,7 7,,,4,5,6,7 57,,4,5,8 87,,4,5,6,8 7,4,5,7,8 8 4 8,,6 68,7 98,6,7 8 8 58,,4,5,8 88,4,5,6,8 8,4,5,7,8 9,4 9,,,6 69,,7 99,,6,7 9,8 59,,,4,5,8 89,,4,5,6,8 9,,4,5,7,8 0,4 40 4,6 70,,7 00,6,7 0,8 60 6,8 90,,4,5,6,8 0,4,5,7,8,,4 4,4,6 7,,,7 0,,6,7,,8 6,6,8 9,,,4,5,6,8,,4,5,7,8,4 4,4,6 7 4,7 0,,6,7,8 6,6,8 9 7,8,,4,5,7,8,,4 4,,4,6 7,4,7 0,,,6,7,,8 6,,6,8 9,7,8,,,4,5,7,8 4,,4 44,4,6 74,4,7 04 4,6,7 4,,8 64,6,8 94,7,8 4 6,7,8 5,,,4 45,,4,6 75,,4,7 05,4,6,7 5,,,8 65,,6,8 95,,7,8 5,6,7,8 6 5 46,,4,6 76,4,7 06,4,6,7 6 4,8 66,,6,8 96,7,8 6,6,7,8 7,5 47,,,4,6 77,,4,7 07,,4,6,7 7,4,8 67,,,6,8 97,,7,8 7,,6,7,8 8,5 48 5,6 78,,4,7 08,4,6,7 8,4,8 68 4,6,8 98,,7,8 8,6,7,8 9,,5 49,5,6 79,,,4,7 09,,4,6,7 9,,4,8 69,4,6,8 99,,,7,8 9,,6,7,8 0,5 50,5,6 80 5,7 0,,4,6,7 40,4,8 70,4,6,8 00 4,7,8 0,,6,7,8,,5 5,,5,6 8,5,7,,,4,6,7 4,,4,8 7,,4,6,8 0,4,7,8,,,6,7,8,,5 5,5,6 8,5,7 5,67 4,,4,8 7,4,6,8 0,4,7,8 4,6,7,8,,,5 5,,5,6 8,,5,7,5,6,7 4,,,4,8 7,,4,6,8 0,,4,7,8,4,6,7,8 4 4,5 54,,5,6 84,5,7 4,5,6,7 44 5,8 74,,4,6,8 04,4,7,8 4,4,6,7,8 5,4,5 55,,,5,6 85,,5,7 5,,5,6,7 45,5,8 75,,,4,6,8 05,,4,7,8 5,,4,6,7,8 6,4,5 56 4,5,6 86,,5,7 6,5,6,7 46,5,8 76 5,6,8 06,,4,7,8 6,4,6,7,8 7,,4,5 57,4,5,6 87,,,5,7 7,,5,6,7 47,,5,8 77,5,6,8 07,,,4,7,8 7,,4,6,7,8 8,4,5 58,4,5,6 88 4,5,7 8,,5,6,7 48,5,8 78,5,6,8 08 5,7,8 8,,4,6,7,8 9,,4,5 59,,4,5,6 89,4,5,7 9,,,5,6,7 49,,5,8 79,,5,6,8 09,5,7,8 9,,,4,6,7,8 0,,4,5 60,4,5,6 90,4,5,7 0 4,5,6,7 50,,5,8 80,5,6,8 0,5,7,8 *40 5,6,7,8 EXAME: DI switch setting for code 00 7
ª edizione /06 cod. G4000780 CERTIFIED MANAGEMENT SYSTEMS www.comelitgroup.com Via Don Arrigoni, 5-400 Rovetta (BG) - Italy