PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002

Similar documents
Precision Farming System Operators Manual

Insight Cable Connections to Rawson, New Leader Mark III & Mark IV, Flexi-Coil Controllers

Insight Cable Connections to Mid-Tech Controllers with Datalink

Activations. Set date and time prior to entering Activation codes to ensure the Activations will be acknowledged. Data Transfer

Precision Farming System PF3000 Cotton Yield Monitor Operators Manual

SeedStar 4 Planter Quick Reference Guide

OPERATORS MANUAL FOR THE LH 665 VRT

We will do our best to ensure that you are happy with your current system and that it is upgraded in the future to better meet your needs.

Available Map Views & Dash View Screen

AgGPS Autopilot Automated Steering System Quick Reference Card

SOFTWARE OPERATING GUIDE

Table of Contents. CenterLine 250/IC18 Quick Start Guide Chapter 1 - Product Overview... 5 Key Functions Startup Sequence...

Quick Reference Guide for Daily use of Yield-Pro Planter

Quick Reference Guide

ACCESSORY APPLICATIONS

Quick Reference Guide

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.*

Cruizer II Snow Depth Feature

Agri-Spread Apollo II

AG3000 Terminal Navigation. Basic Mode Operation

For use with Aeros 9040 v4.30 DynaJet Flex IC18 Sprayer v1.10

834-P Sprayer Control User Guide (Y1.04) R0

OPERATOR S GUIDE. Document revision: 1.0 Last revised: January 29, 2018

Quick Reference Card. Setting up the FmX Integrated Display with the Autopilot System

Quick Reference Guide for Daily use of Yield-Pro Planter

Table of Contents. GPS Legacy Products...1 Configuring GPS 6500 and 6000 For Legacy Displays...1

TopCon X5 Operator's Manual

Ag Leader Technology. DirectCommand Installation Rogator 900/1100/1300 Sprayers

DirectCommand Installation 5 Channel Spreader Control Module Technology

Agxcel. AgXcel GX2. Fertilizer System Integration for Integration into TOPCON. AgXcel GX2 Dual Electric Pump GPA Specifications GX2B

Part Name/Description Part Number Quantity

DirectCommand Installation RoGator Model Year Ag Leader Technology

Quick Reference Card

PM PLANTER MONITOR. Operator s Manual

NOTE: This is only a guide! Please consult your local dealer for detailed instructions or troubleshooting!

Pro-Series 8000i Artemis Variable Rate Drill Control Calibration

Loup Electronics Planter Monitor LPM II. User Guide

TABLE OF CONTENTS. Safety Notices... 1

Note: Indented items indicate parts included in an assembly listed above

InSight User Manual Firmware Version 8.0 Ag Leader PN Rev. H

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

Operating Instructions

Generation 4 Displays Software Update 18-1 Release Notes

IF YOU DO NOT UPDATE BOTH THE DISPLAY AND DESKTOP SOFTWARE VERSIONS, DATA LOSS COULD OCCUR WHEN UNLOADING DATA.

Note: Indented items indicate parts included in an assembly listed above

EDGE User Manual Firmware Version 4.5 Ag Leader PN Rev. F

Transporting Data Files from the Office to the Field Manual Mode

Ag Leader Technology. DirectCommand Installation RoGator Model Years

SINCE 1966 INTELLIAG AI-120 ISO VIRTUAL TERMINAL. Operator s Manual

Note: Indented items indicate parts included in an assembly listed above

Table of Contents. Part I USB Communication. Part II User Interface. Part III User Settings (Tab Control) DFS-1000 Dataview. 2 File Menu.

AG-NAV GUÍA LITE Differential GPS Guidance System. OPERATOR S HANDBOOK Version Sept. 2017

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

Online - Display and CommandARM TM Simulator. Help Guide

Farm Works Mobile with Geonics Sensors

Introduction... 3 Features... 3 Harness Connections... 4

CFX-750 Menus. Starting in the Settings Menu

Front-Fold Planters All Makes & Models

GETTING STARTED GUIDE

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.6.*

Online - Display and CommandARM TM Simulator. Help Guide

VM Operator s Manual. The Daugherty Companies, Inc. P.O. Box 306 Warren, IN Ph Fax

MEDALLION INSTRUMENTATION SYSTEMS MasterCraft Viper system

CS 440RC. Solid De-icer Controller Detailed Configuration and Set-up Manual

Task Controller Setup Manual

Instructions for Micro-Trak Liquid Systems Used with TOPCON ASC-10 System 150 Direct Connect

Trimble FMX/FM100 - with Hydraulic Steer - Case IH Factory Install Installation & Configuration Guide for Harness :

icon SYSTEM 2016 QUICK START GUIDE

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

GPS 2000/2100. Operator s Manual. Copyright 1998 Ag Leader Technology

INTEGRA Version Firmware Release

with the Yield Monitoring System Quick Reference Card

Release Notes. Important Notes:

Strip Till. Ultimate in Strip Till Versatility & Performance. The. Toll Free:

Installation & Operation Manual

ISOBUS Quick Reference Installation Guide. Liquid Fertilizer Anhydrous Ammonia Sprayer Spreader Slurry

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

AEROS FIELD COMPUTER RELEASE NOTES RELEASE NOTES

Installation & Operation Manual

IntelliAg Planter/Drill Control. Operator s Manual DICKEY-john Corporation

Display Quick Reference Guide

Ag Leader Technology. DirectCommand Installation Miller Nitro 5000 & 6000 ISO Kit

MATRIX GUIDANCE RELEASE NOTES

we can help you get there Wherever your Precision Agriculture is taking you... Service & Products for Precision Agriculture

Cobalt - Basic Setup Setting up Grower, Farm, Field

844-AB SPRAYER CONTROL

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Introduction... 1 System Overview Safety Notices... 5

GENERAL DESCRIPTION... 1 INSTALLATION... 2 CONNECTIONS... 3 OVERVIEW... 6 AREA & SPEED METER SETUP (WIZARD)... 9

User Manual. Gateway 6.2: Map Math

Rigid Planters All Makes & Models

DirectCommand Installation RoGator 864/874/1064/1074 (MY 2006 & Earlier) Ag Leader Technology

DEFAULT SCREEN. Button and Screen Layout DRILLING WIDTH TARGET RATE HOPPER NUMBER CROP NAME DRILLING ACTION CROP NUMBER. HOPPER selection POWER On/Off

Operator s Manual. Morbark Integrated Control System Woodhog Series Model 2600

RELEASE NOTES. FmX Integrated Display. Introduction. Feature change overview. Feature changes. Upgrade procedure

Legacy 6000 MID-TECH ESC. RMS-Office User Guide. Roadway Management S Y S T E M

OPERATING INSTRUCTIONS. ICE31 Version August, 2005

GETTING STARTED 5 WORKING WITH CUTTING DEVICE SETUPS 11 TABLE OF CONTENTS. Basic elements of your software 5. Setup area 6 Job area 6

CS 550/150 Symmetry. Spreader and Joystick Controller Calibration Manual

Pro-Series 8000i Artemis Variable Rate Drill Control Operation

Transcription:

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002 Menu Key FIELD LOAD SHOW MAP OPTIONS CAL SETUP DIAG Press Menu Key to switch between Main Menu keys FIELD LOAD SHOW MAP OPTIONS [Create or change field and name field functions. Active configuration for field displayed.] VIEW CONFIG [Create or change load and name load functions.] [Splits screen and shows On Screen Map on left side. Press HIDE MAP key to return to full screen. ] MARKS LIGHTBAR NAVIGATE BOUNDARY GRID [Set active configuration and active tgt prescription file.] SET A SET B RESET PAUSE ADD/STRT CLR/STOP AREA PT ACTIVE ON/OFF EDIT TGT FILE [Select and accept new tgt prescription file.] VIEW INFO Press at beginning of reference pass. Press at end of reference pass. When using curve pattern, press at end of every pass. Press to reset and area points to start a new field. Press to pause when filling applicator. Drive back to swath and press RESUME key. Used for Headlands. See Lightbar Manual. Used for Headlands. See Lightbar Manual. Press at every corner of field to calculate field area. Must have Field Area displayed on main screen to see area. [Screen displays field, product, units/ac and default rate stored in tgt file.] Revision 3 1 of 9 P.N. 2002831-16

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002 Menu Key FIELD LOAD SHOW MAP OPTIONS CAL SETUP DIAG Press Menu Key to switch between Main Menu keys CAL SETUP DIAG AREA DISTANCE APP RATE CONFIG MARKS CARD LOAD CONSOLE MEMORY GPS MAP [Radar calibration screen] [Screen Displays all product/controller configurations] EDIT CREATE NEW DELETE Logging device Logging interval Log file [To erase files, press SHOW ALL FILES key, select file, press FILE OPTIONS key and press ERASE FILE key.] Operating mode Units of Measure Month/Day/Year Time Serial number Box cal Voltage cal GPS check sum Field marker input Display brightness [Clear data in loads or erase all fields functions] Selections NMEA MESSAGE GPS/PORT CONFIGURATION BEACON DIFFERENTIAL SATELLITE DIFFERENTIAL LIGHTBAR GUIDANCE SYSTEM SENSORS GPS RAW NMEA Controller Make Controller Model Product Units Ground Speed Source App Distance From GPS Full Swath Tgt Units:Contrler Units Target Rate Increment Actual Rate Scale Factor ADVANCED CONTRLER Guidance Screen Pattern Headland Type Look-Ahead Display Mode Swath Direction Swath Width Antenna Offset Pass Skips Units Displayed Contour Log Interval Satellite Differential Screen Differential source = BEACON or WAAS or SATELLITE Differential provider Satellite frequency Satellite baud rate Provider user code Omnistar code Subscription expiration Age of differential Target rate outside field Controller time delay Actual rate units Log actual rate Drive # of seeds/row/5 rev Number of rows Drive A Number of rows Drive B Number of rows Drive C Actual rate source Jump start speed Maximum drive RPM Manual speed Manual speed Revision 3 2 of 9 P.N. 2002831-16

PF3000 Pro Quick Reference Setup Instructions for Direct Drive of Accu-Rate drive on a planter March 2002 CAUTION: When hydraulics are turned on to the hydraulic drive, the planter is ready to run. KEEP CLEAR OF MOVING PARTS! MANDATORY: You must install and use a planter monitor. It will inform you of plugged rows or rows not planting. for Direct Control of Rawson Accu-Rate drive for planting 1. Press SETUP key. Press APP RATE CONFIG key. Press CREATE NEW key. Set the following: Controller Make: Set to DIRECT. Controller Model: Set to RAWS PLANT. Product: Press EDIT key. You can select an existing product and press ACCEPT key or create a new product by pressing CREATE NEW key. Press EDIT NAME key and enter name of hybrid or variety. Use Left or Right Arrow keys to select a character. Use Up or Down Arrow key to change the character. Set each character and press ACCEPT key twice. Units: Set to SEEDS. This is the Units/Acre of application. Ground Speed Sensor: Set to RADAR. GPS is not recommended. App Distance From GPS: Set to distance between planter toolbar and position of GPS antenna on tractor. Example: If toolbar is 20 feet behind GPS antenna set to 20 ft back. Full Swath: Set to full swath of planter (# of rows x Row Spacing in feet). Example: 12 row planter, 30 inch row spacing. 12x2.5ft=30 ft Tgt Units:Contrler Units: Set to 1:1.0000. This ratio is used to convert the units in a target file (.tgt) to the units of application. If your planting target file is in seeds/ac set this number to 1:1.0000. Target Rate Increment: Set to 500.0 or 1000.0. This determines the increment value by which you can change the manual target rate with each press of Up or Down arrow keys. Actual Rate Scale Factor: Set to 1.000. 2. Press CONTRLER key. Set the following: Drive: If you have a single drive system set to DRIVE A. If you have a dual drive system set to DRIVE AB. If you have a three drive system, set to DRIVE ABC. # of seeds/row/5 rev: 1)Fill seed hopper with appropriate amount of seed. 2)Place container under hopper to catch seeds. 3)Press CAL DRIVE key and press START key. (Use caution, planter will run for 5 turns of the hydraulic drive). 4)Count seeds and rerun drive to find a true average value. Might need to ignore initial runs because hopper dispensing unit is not fully primed. 5)Press EXIT key and enter the correct value for this setting. Number of rows Drive A: Set to number of rows controlled by Drive A. Number of rows Drive B: Set to number of rows controlled by Drive B. Number of rows Drive C: Set to number of rows controlled by Drive C. Actual Rate Source: Normally set to DRIVE RPM. Set to SEED MANGR if want to get the rate from a Seed Manager or Vanguard planter monitor. Jump start speed: Set to 2 mph Maximum drive RPM: Set to 300 rpm unless otherwise advised. The Pro will not let the drive rpm get above this setting. A message SLOW DOWN!! will be displayed every time the maximum rpm is reached. Manual speed: Set this to your average speed if you are using manual speed in place of your radar gun. Manual speed: Normally this should be set to OFF. The only reason to set this to ON is if you can not get ground speed from your radar gun or you want to run the drive in a stationary position. 3 Press EXIT key to return to screen with ADVANCED key. Press the ADVANCED key. Target Rate Outside Field: This only pertains to using a target file. Set to ZERO if want rate outside field to be zero. Set to USE LAST if want rate to be the last rate used at the time the vehicle is detected outside the field. This is useful when experiencing problems with the vehicle being falsely detected outside of the field during the outside pass. Set to TGT DEFAULT if want rate outside field to be the default rate stored in the target rate file. Controller Time Delay: Set to 3 seconds. Actual Rate Units: Set to SEEDS. Log Actual Rate: Set to YES to log actual rate to card. Set to NO, otherwise. 4 Exit back to main screen. a)press FIELD key twice. b)select appropriate field and press VIEW CONFIG key. c)select appropriate product/controller configuration and press ACTIVE ON/OFF key to check it as active.(all other configs must be unchecked first). d)if you will be using a target file, press EDIT TGT FILE key, otherwise press EXIT key and skip to step f. e)select target file. Press VIEW INFO key to ensure it is the correct one. After exiting the view info screen, press ACCEPT key. Press EXIT key. f)press ACCEPT key to accept field. Revision 3 3 of 9 PN: 2002831-16

PF3000 Pro Quick Reference Setup Instructions for Direct Drive of Accu-Rate drive on a planter March 2002 5 Press CAL key. Press DISTANCE key. a)select RADAR and press ENTER DISTANCE key. b)pick a good place to travel back and forth in a straight line. Measure and mark off a travel distance. A path of at least 200 feet is suggested. c)select line displaying Actual Distance and set the distance equal to the measured distance. (To select line, press key to right of line). d)position vehicle at the beginning of the path. e)press CLEAR DISTANCE key if Measured Distance is greater than zero. f)press START TRAVEL key and drive vehicle until you reach the end of the path. Stop it at the end of the path. g)press STOP TRAVEL key. Press PERFORM CAL key. h)repeat steps d-g to verify the accuracy of the calibration. i)press EXIT key to return to main screen. Setting the Target Rate 1 The display item Target Rate must be displayed on the main screen to set the rate. Arrow symbols on the line displaying target rate indicate that this display item is selected for changing. Press the key to the right of the line displaying target rate if you do not see these arrows. Press it again to deselect the line (remove the box) but keep the arrow symbols. 2 You can either set a manual rate or use a target file to automatically control the rate based on the vehicle position in the field. Setting a manual rate a) Press Right Arrow key to highlight man ( m if viewing on screen map). b) Use the Up or Down Arrow keys to set the manual rate. c) If you want to change how much the rate changes with each arrow press refer to step 1 on other side of sheet and edit the Target Rate Increment setting. Using a target file and setting an automatic rate a) Press Left Arrow key to highlight auto ( a if viewing on screen map). b) You must have a target file (.tgt) selected for the field, otherwise the rate will always be zero. Refer to step 4 on other side on how to set the Target File. You can switch between auto and man whenever you are on the main screen and Target Rate is selected for changing. Selecting display items You can display four different items on the main operating screen. To change what is displayed, press the key to the right of the line you want to change. Scroll through the list of display items shown on the bottom by pressing the bottom left and right arrow keys. Press the key on the bottom to pick which display item you want. Useful display items (more available than listed here) Target Rate (required) Actual Rate based on RPM of drive Ground Speed Drive Status displays when drive is on or off Drive RPM Total Units Turning Drive(s) On/Off Use the external on/off toggle switch (provided by Rawson) to turn the drive(s) on or off. Rawson does offer an optional Whisker Switch (Part Number: 300779) for installing on the implement. When the drive is on, the green light on the switch located on the lower right of the front panel of the Pro will be on. When the drive is off, the red light will be on. Dual Drive system A special dual drive selector switch provided by Rawson will come wired in with the master on/off toggle switch if you have a dual drive system. The Pro uses this switch to turn Drive A or B off independently or keep them both on (as long as master on/off switch is on). The Pro also automatically adjusts the swath based on which drives are on for accurate area counting. Three Drive system A special three drive switch console provided by Rawson comes with your three drive system. This console works in conjunction with the master on/off switch. The Pro automatically adjusts its swath based on which drives are on. Using jump start speed When you start planting from a stationary position, you should push and hold the master on/off toggle switch in the fully on or forward position. The Pro will set the ground speed equal to the jump start speed set in step 2 (see other side) until the speed from the radar gun gets above the jump start speed. You will only have to hold the switch down for a short time. Using jump start speed prevents skips when starting from a stand still. Revision 3 4 of 9 PN: 2002831-16

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a fertilizer applicator March 2002 Menu Key FIELD LOAD SHOW MAP OPTIONS CAL SETUP DIAG Press Menu Key to switch between Main Menu keys FIELD LOAD SHOW MAP OPTIONS [Create or change field and name field functions. Active configuration for field displayed.] VIEW CONFIG [Create or change load and name load functions.] [Splits screen and shows On Screen Map on left side. Press HIDE MAP key to return to full screen. ] MARKS LIGHTBAR NAVIGATE BOUNDARY GRID [Set active configuration and active tgt prescription file.] SET A SET B RESET PAUSE ADD/STRT CLR/STOP AREA PT ACTIVE ON/OFF EDIT TGT FILE [Select and accept new tgt prescription file.] VIEW INFO Press at beginning of reference pass. Press at end of reference pass. When using curve pattern, press at end of every pass. Press to reset and area points to start a new field. Press to pause when filling applicator. Drive back to swath and press RESUME key. Used for Headlands. See Lightbar Manual. Used for Headlands. See Lightbar Manual. Press at every corner of field to calculate field area. Must have Field Area displayed on main screen to see area. [Screen displays field, product, units/ac and default rate stored in tgt file.] Revision 3 5 of 9 P.N. 2002831-16

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a fertilizer applicator March 2002 Menu Key FIELD LOAD SHOW MAP OPTIONS CAL SETUP DIAG Press Menu Key to switch between Main Menu keys CAL SETUP DIAG AREA DISTANCE APP RATE CONFIG MARKS CARD LOAD CONSOLE MEMORY GPS MAP [Radar calibration screen] [Screen Displays all product/controller configurations] EDIT CREATE NEW DELETE Logging device Logging interval Log file [To erase files, press SHOW ALL FILES key, select file, press FILE OPTIONS key and press ERASE FILE key.] Operating mode Units of Measure Month/Day/Year Time Serial number Box cal Voltage cal GPS check sum Field marker input Display brightness [Clear data in loads or erase all fields functions] Selections NMEA MESSAGE GPS/PORT CONFIGURATION BEACON DIFFERENTIAL SATELLITE DIFFERENTIAL LIGHTBAR GUIDANCE SYSTEM SENSORS GPS RAW NMEA Controller Make Controller Model Product Units Ground Speed Source App Distance From GPS Full Swath Tgt Units:Contrler Units Target Rate Increment Actual Rate Scale Factor ADVANCED CONTRLER Guidance Screen Pattern Headland Type Look-Ahead Display Mode Swath Direction Swath Width Antenna Offset Pass Skips Units Displayed Contour Log Interval Satellite Differential Screen Differential source = BEACON or WAAS or SATELLITE Differential provider Satellite frequency Satellite baud rate Provider user code Omnistar code Subscription expiration Age of differential Target rate outside field Controller time delay Actual rate units Log actual rate Fertilizer type Drive Gate setting or rate setting Material density Delivery rate Gear ratio Jump start speed Maximum drive rpm Drive switch Manual speed Manual speed Revision 3 6 of 9 P.N. 2002831-16

PF3000 Pro Quick Reference Setup Instructions for Direct Drive of Accu-Rate drive on a fertilizer applicator March 2002 CAUTION: When hydraulics are turned on to the hydraulic drive, the applicator is ready to run. KEEP CLEAR OF MOVING PARTS! for Direct Control of Rawson Accu-Rate drive for fertilizing 1. Press SETUP key. Press APP RATE CONFIG key. Press CREATE NEW key. Set the following: Controller Make: Set to DIRECT. Controller Model: Set to RAWS FERT. Product: Press EDIT key. You can select an existing product and press ACCEPT key or create a new product by pressing CREATE NEW key. Press EDIT NAME key and enter name of product. Use Left or Right Arrow keys to select a character. Use Up or Down Arrow key to change the character. Set each character and press ACCEPT key twice. Units: Set to the Units/Acre of application. Ground Speed Sensor: Set to RADAR or GPS. App Distance From GPS: Set to distance between where product exits applicator and position of GPS antenna on vehicle. Example: If fan or spinner on fertilizer buggy is 20 feet behind GPS antenna set to 20 ft back. Full Swath: Set to full swath of applicator in feet. Tgt Units:Contrler Units: Normally this is set to 1:1.0000 and only pertains to using a target file. This ratio is used to convert the units in a target file (.tgt) to the units of application. Example: If your lime target file is in lbs/ac and you apply based on tons/ac your ratio will be 1:0.0005. Target Rate Increment: This determines the increment value by which you can change the manual target rate with each press of Up or Down arrow keys. Actual Rate Scale Factor: Use chart below for setting. Avg. Speed Swath Application Rate between Scale Factor 0-25 mph 0-80 ft 0-10 units/ac 1.000 0-10 mph 0-80 ft 11-100 units/ac 1.000 11-15 mph 0-50 ft 11-100 units/ac 1.000 11-15 mph 51-80 ft 11-100 units/ac 0.100 16-25 mph 0-80 ft 11-100 units/ac 0.100 0-25 mph 0-80 ft 101-500 units/ac 0.100 0-10 mph 0-80 ft 501-1000 units/ac 0.100 11-15 mph 0-50 ft 501-1000 units/ac 0.100 11-15 mph 51-80 ft 501-1000 units/ac 0.010 16-25 mph 0-80 ft 501-1000 units/ac 0.010 0-25 mph 0-80 ft 1001+ units/ac 0.010 When the data is mapped, the rate will be 1/10 th of the real rate when the Actual Rate Scale Factor is 0.100. It will be 1/100 th of the real rate when the Actual Rate Scale Facotr is 0.010. The rate actually applied and rate that appears on Pro is unaffected by this setting. 2. Press CONTRLER key. Set the following: Fertilizer type: Set to DRY or LIQUID. Drive: Set to DRIVE A. Gate Setting (dry) or Rate Setting (liquid): If applying dry product, enter the feed gate opening in inches. If applying liquid and using a John Blue piston pump enter the stroke setting (usually between 1-10). Material density: If applying dry product, enter the density of product in lbs/cubic feet. If applying liquid product, this number will be automatically set to 1.0 and it can not be changed. Delivery rate: If applying dry product, enter the cubic feet/rev per 1 inch of gate setting of applicator (not hydraulic drive). If applying liquid product and using a John Blue piston pump, enter the gal/rev per one stroke of pump. If pump is model LM-2450, enter.0047. If pump is model LM-4450, enter.0076. If pump is model LM-4950, enter.0152. Gear ratio: Enter ratio of sprockets from applicator to hydraulic drive. See Rawson manual for selecting proper sprockets. Jump start speed: Set to 2 mph Maximum drive RPM: Set to 500 rpm unless otherwise advised. The Pro will not let the drive rpm get above this setting. A message SLOW DOWN!! will be displayed every time the maximum rpm is reached. Drive Switch: Set this to EXTERNAL to turn drive on/off using On/Off/Jump start switch or whisker switch from Rawson. Set to INTERNAL to shut drive on/off using switch on bottom right of Pro s front panel. Manual speed: Set this to your average speed if you are using manual speed in place of your radar or GPS ground speed source. Manual speed: Normally this should be set to OFF. The only reason to set this to ON is if you can not get ground speed from your radar or GPS or you want to run the drive in a stationary position. Revision 3 7 of 9 PN: 2002831-16

PF3000 Pro Quick Reference Setup Instructions for Direct Drive of Accu-Rate drive on a fertilizer applicator March 2002 3 Press EXIT key to return to screen with ADVANCED key. Press ADVANCED key. Target Rate Outside Field: This only pertains to using a target file. Set to ZERO if want rate outside field to be zero. Set to USE LAST if want rate to be the last rate used at the time the vehicle is detected outside the field. This is useful when experiencing problems with the vehicle being falsely detected outside of the field during the outside pass of the field. Set to TGT DEFAULT if want rate outside field to be the default rate stored in the target rate file. Controller Time Delay: Set to 3 seconds. Actual Rate Units: Set to Units/ac of application. Log Actual Rate: Set to YES to log actual rate to card. Set to NO, otherwise. 4 Exit back to main screen. a)press FIELD key twice. b)select appropriate field and press VIEW CONFIG key. c)select appropriate product/controller configuration and press ACTIVE ON/OFF key to check it as active.(all other configs must be unchecked first). d)if you will be using a target file, press EDIT TGT FILE key, otherwise press EXIT key and skip to step f. e)select target file. Press VIEW INFO key to ensure it is the correct one. After exiting the view info screen, press ACCEPT key. Press EXIT key. f)press ACCEPT key to accept field. 5 Press CAL key. Press DISTANCE key. a)select RADAR and press ENTER DISTANCE key. b)pick a good place to travel back and forth in a straight line. Measure and mark off a travel distance. A path of at least 200 feet is suggested. c)select line displaying Actual Distance and set the distance equal to the measured distance. (To select line, press key to right of line). d)position vehicle at the beginning of the path. e)press CLEAR DISTANCE key if Measured Distance is greater than zero. f)press START TRAVEL key and drive vehicle until you reach the end of the path. Stop it at the end of the path. g)press STOP TRAVEL key. Press PERFORM CAL key. h)repeat steps d-g to verify the accuracy of the calibration. i)press EXIT key to return to main screen. Setting the Target Rate 1 The display item Target Rate must be displayed on the main screen to set the rate. Arrow symbols on the line displaying target rate indicate that this display item is selected for changing. Press the key to the right of the line displaying target rate if you do not see these arrows. Press it again to deselect the line (remove the box) but keep the arrow symbols. 2 You can either set a manual rate or use a target file to automatically control the rate based on the vehicle position in the field. Setting a manual rate a) Press Right Arrow key to select man ( m if viewing map). b) Use the Up or Down Arrow keys to set the manual rate. c) If you want to change how much the rate changes with each arrow press refer to step 1 on other side of sheet and edit the Target Rate Increment setting. Using a target file and setting an automatic rate a) Press Left Arrow key to highlight auto ( a if viewing map). b) You must have a target file (.tgt) selected for the field, otherwise the rate will always be zero. Refer to step 4 on other side on how to set the Target File. You can switch between auto and man whenever you are on the main screen and Target Rate is selected for changing. Selecting display items You can display four different items on the main operating screen. To change what is displayed, press the key to the right of the line you want to change. Scroll through the list of display items shown on the bottom by pressing the bottom left and right arrow keys. Press the key on the bottom to pick which display item you want. Useful display items (more available than listed here) Target Rate (required) Actual Rate based on RPM of drive Ground Speed Drive Status displays when drive is on or off Drive RPM Total Units Tgt File Rate Shows rate from target file. This will be different from rate shown Target Rate display item if Tgt Units:Contrler Units ratio is not 1:1.0000. Revision 3 8 of 9 PN: 2002831-16

PF3000 Pro Quick Reference Setup Instructions for Direct Drive of Accu-Rate drive on a fertilizer applicator March 2002 Turning Drive On/Off Use the external on/off toggle switch (provided by Rawson) to turn the drive on or off. Rawson does offer an optional Whisker Switch (Part Number: 300779) for installing on the implement. When the drive is on, the green light on the switch located on the lower right of the front panel of the Pro will be on. When the drive is off, the red light will be on. Using jump start speed When you start applying from a stationary position, you should push and hold the master on/off toggle switch in the fully on or forward position. The Pro will set the ground speed equal to the jump start speed set in step 2 (see other side of sheet) until the speed from the radar gun or GPS gets above the jump start speed. You will only have to hold the switch down for a short time. Revision 3 9 of 9 PN: 2002831-16