SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

Similar documents
GS Dupline Profinet Gateway. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

SBPDIS2Axx. Dupline Carpark Display. Benefits. Description

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

SPST-NO SPDT DPST-NO DPDT

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

02/11/2015

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Zelio Control-modular measurement and control relays 1

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

SA2WEB24. Central unit module. Benefits. Description

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

B5X-LS4-U. Light switch. Benefits. Description

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

SRT2-ROC08, SRT2-ROC16

SH2WEB24. Central unit module. Benefits. Description

02/11/2015

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Zelio Control Measurement Relays Multifunction 3-phase supply control relays RM17T 00

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RM35TF V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM35LM33MW liquid level control relay RM35-L V AC/DC

Energy Management BUS Adapter Type VMU-B

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Programmable controller MCX152V

Syr-line TMR48D Digital Timer

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

XPSMCMDO Digital output pairs expansion modules with screw term

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Interface Relay CRINT-1x

Syr-line TMR48D Digital Timer

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy Management BUS Adapter Type VMU-B 01

MCX06C Programmable controller

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Technical data. Safety notes. Product features

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Time Counters mini "h", DC Version

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Programmable Relay ZEN V2 Units

Visualize the actual worksite status! Simple and Intelligent I/O Slave Units.

DI572 Digital Input Module

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

General information. Display. Supply voltage

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

must Operate Voltage (V)

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

Analog Voltage Combination Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

EM270. Multi-channel power analyzer. Benefits. Description

ETD-BL-1T-OFF-CC- 10S

General information. Display. Supply voltage. Input current

XPSMCMMX inputs 2 output pairs expansion module with screw term

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

TU531, TU532 Terminal Unit

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

General information. Display. Supply voltage. Input current. Encoder supply. Output current

BMX DDM Mixed Relay Input/Output module

Transcription:

Fire damper I/O Module Benefits Ready-to-use junction box housing for fast and easy decentral installation One I/O-module can control and monitor two fire dampers Fast and easy wiring to the main controller through the Dupline bus (free topology and long distance capability) Up to 64 fire dampers on one Dupline bus segment The system can be interfaced to the main controller via BACnet or Modbus Description The module is an I/O module for monitoring and control of two fire dampers. The module has 4 contact inputs for position feedback and relay outputs for control of fire damper actuators. The I/O module is implemented in a robust junction box for a decentralized installation near the two fire dampers. The I/O module is part of the Smart building product range. Several I/O modules can be multi-dropped via the same Dupline -wire bus and thus the wiring to the controller can be significantly simplified. Applications Control and monitoring of fire damper Main functions Robust I/O module in junction box housing 4 x contact input (voltage free) +SPST relay output (30VAC/3A) Smart Dupline protocol 30 VAC power supply Easy installation EG

Features Power Supply Power supply 30 VAC ±5% Max current consumption 3. VA Max current on -out / -out Bridge 0 Amp (Internal bridge on PCB) See fig. out out I(+) I(-) I(+) I(-) I3(+) I3(-) I4(+) I4(-) m m M D(+) D(-) D(+) D(-) Fig. Dashed lines indicate internal connection on the PCB. Max.0 Amp is allowed. Dupline bus Dupline voltage rated Min. Dupline peak voltage Dupline Current consumption 8. V 4.5 V. ma EG

Inputs umber of inputs 4 Type Voltage-free contact Cable length < 0 m Outputs umber of outputs Type SPST AC Max. switching voltage 50 VAC Max. current load 5 Amp (50 VA) DC Max. switching voltage 30 VDC Max. current load 3 Amp (90 watt) Indication Power supply Green ED Bus OK Yellow ED Input OK Yellow ED x 4 Output OK Yellow ED x 4 The input EDs indicate when the input is active (taking care of the O/C configuration) The output EDs indicate when the relay is active and closed (C) (According to the O/C configuration) Environmental Pollution degree (IEC 60664-. Par. 4.6.) Operating temperature 0 to 50 C (-4 F to F) Storage temperature -50 to 85 C (-58 F to 85 F) Humidity 0 to 90% (not condensing) Degree of protection IP55 EMC Immunity Emission E6000-6- E6000-6-3 Mechanics EG 3

Housing Type Dimensions (HxWxD) Standard junction box with 0 knockout openings for or 6 cable 50 x 0 x 70 mm Terminal block Power supply in / out 4 x Spring terminal Dupline bus in / out 4 x Spring terminal Relay inputs 4 x Spring terminal Contact inputs 8 x Spring terminal Cross-section area Terminal:.5 mm Power for Motor and Motor 4 x Spring terminal Dielectrical strength Power supply to Input Power supply to Dupline Dupline to input Dupline to output Input to output Power supply to output Inputs not insulated from each other 4 KVAC for min., 6 KV impulse. / 50 µs Isolation Isolation between Power supply and output If the installer uses the external bridge m / m, the same power supply for PCB and motors must be used. However, in this case the isolation (Power supply to output) is lost. EG 4

Wiring I J A B I H G out out I I I I3 I3 I4 I4 3 4 C m m M D+ D- D E M M D+ D- F A Bus OK F Dupline OUT B Power OK G External power to the motors C I H Green bridge D OUT I Power supply 30 VAC E Dupline I J 30 VAC OUT ote: Do not use if green bridge is used. If the green bridge is used, the motors are powered from the module. EG 5

Compatibility and conformity Approvals CE-marking cuus According to U 60950 Programming The fire damper module is programmable by using the configuration tool Input.O. (Default).C. Filter O From To Input 0 ms* s (step of 6 ms) *(Default filter O input 0 s) Output Configuration state.o..c..o..c. Mode of operation The is a 4 inputs and SPST outputs module designed for monitoring and controlling of two fire dampers. The I/O module is part of the Smart Building product range, and several I/O modules can be multi-dropped via the same Dupline -wire bus whereby the wiring to the controller is significantly simplified. The module must be programmed before use by means of the SBWEB configuration tool. The output relays can be powered with 30 VAC by the module itself or by external power supply. See relay specification. EG 6

References Product selection key Code Options Description SB - Smart building B - Box (Housing) 4I - 4 inputs O - outputs 30 - Power supply COPYRIGHT 05 Content subject to change. Download the PDF: www.productselection.net EG 7