Magnetically Coded Non Contact Switch (MC2) Installation Instructions

Similar documents
SensaGuard TM Rectangular Flat Pack Unique Coded Installation Instructions

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

SensaGuard. Description. Features. Benefits. Specifications

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

MSR178DP. Description. Features. Specifications

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts

SafeC S to MSR127 Conversion

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

SensaGuard 18 mm Barrels

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding

MSR42 Micro 400 Controller/Muting Module

3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard

Magnetically Actuated Safety Interlock Switches

NHP SAFETY REFERENCE GUIDE

TLSZR/L-GD2 Guard Locking Switch Installation Instructions

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Magnetically Actuated Safety Interlock Switches

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Compact Magnetic Non-contact Safety Switches. Model Number Structure

3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.

Application Technique. Safety Function: Safety Camera with E-stop

Magnetic Non-contact Safety Switches. Model Number Structure

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Tongue Switches Trojan 5 & 6

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Compact Coded Magnetic Safety Interlock Switch and Control Units

Datasheet - RSS 36-D-R-ST

Operating instructions. Switching amplifier DN0210 DN / / 2015

Original operating instructions Fail-safe inductive sensor GI712S

MECHAN. CAT 4 SIL 3 PLe. Installation Guide : SCU-1 & HE Safety Switches. Description. Operation. Applications. Declaration of Conformity

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Auxiliary Contacts

Original operating instructions Fail-safe inductive sensor GG711S

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions. Speed monitor D / / 2014

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Coded Non-Contact Safety Sensor Eden OSSD

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Safety Light Curtains GuardShield Remote Teach

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

NHP SAFETY REFERENCE GUIDE

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

Presence Sensing Safety Devices

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Compact Magnetic Non-contact Safety Switches. Model Number Structure

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

SR B series coded magnetic safety sensors

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Datasheet - CSS 11-30S-D-M-ST

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Guardmaster Safety Relays DI, DIS, SI, CI, GLP, EM, And EMD

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

Coded magnetic safety sensor SR B series

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Operating instructions Safety sensor BNS About this document. Content

Bulletin 800Z Zero-Force Touch Buttons

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Inputs. Switching Voltage, Min. Conductor Size, Max.

Application Technique. Safety Function: SensaGuard Non-contact Interlock Switch

Operating instructions Safety sensor BNS About this document. Content

Installation instructions Inclination sensor EC2019 EC / / 2013

Bulletin 440R 440R 440R-S

Safety. Detection. Control. MAGNUS RFID ENG - REV

MECHAN CONTROLS. CAT 4 SIL 3 PLe. Installation Guide : F-SERIES Safety system

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

MA Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Declaration of Conformity

Datasheet - SRB 301LC/B-24V

Lifeline 5 Cable-pull Safety Switch

User's Manual. english

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Datasheet - AZM300Z-ST-1P2P-A

em4 Accessories Digital expansions

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

CompactBlock Guard I/O Modules ArmorBlock Guard I/O Modules POINT Guard I/O Modules

SR A series coded magnetic safety sensor

Magnetic Style Safety Interlock Switches

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Safety Mats & Area Guarding

AS-i Safety Relay Output Module with Diagnostic Slave

NHP SAFETY REFERENCE GUIDE

Operating instructions. Standstill monitor A / / 2011

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Transcription:

Magnetically Coded Non Contact Switch (MC2) Installation Instructions 44N-Z21W1PA 44N-Z21W1PB 44N-Z21W1PH 3 Metre Cable 1 Metre Cable 8-Pin micro (M) Pigtail Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE e: Refer to Technical Specifications for Certification information and ratings.

2 Magnetically Coded Non Contact Switch Installation Instructions ENGLISH: GERMAN: FRENCH: ITALIAN: SPANISH: PORTUGUESE: POLISH: This instruction sheet is available in multiple languages at www.rockwellautomation.com/literature. Select publication language and type "SensaGuard" in the search field. Dieses Instruktionsblatt kann in mehreren Sprachen unter www.rockwellautomation.com/literature gelesen werden. Bitte Ihre Sprache anwählen und "SensaGuard" im Suchfeld eintippen. Ces instructions sont disponibles dans différentes langues à l'adresse suivante www.rockwellautomation.com/literature. Sélectionner la langue puis taper SensaGuard dans le champ de recherche. La presente scheda d'istruzione è disponibile in varie lingue sul sito www.rockwellautomation.com/literature. Selezionare la lingua desiderata e digitare "SensaGuard" nel campo di ricerca. Puede encontrar esta hoja de instrucciones en varios idiomas en www.rockwellautomation.com/literature. Seleccione el idioma de publicación y escriba "SensaGuard" en el campo de búsqueda. Esta folha de instruções está disponível em várias línguas em www.rockwellautomation.com/literature. Seleccione a língua de publicação e entre com "SensaGuard" no espaço de busca. Ta kartka z instrukcjami jest dostepna w wielu jezykach na stronie: www.rockwellautomation.com/literature Wybierz jezyk publikacji i wpisz w polu poszukiwania "SensaGuard". Table of Contents Installation Instructions 3 Warnings 3 Technical Specification 3 Safety Ratings 3 Operating Characteristics 3 Physical Characteristics 3 Outputs 3 Response Time 3 Environmental 3 Protection 4 Dimensions 4 Mode of Operation 4 Status Indicators 4 Mounting Information 4 Nut Torque Specification 4 Minimum Distance Between Sensors 5 Misalignment Curve 5 Diagnostics 6 Troubleshooting 6 Wiring Diagram 7 Recommended Mating Cable 7 Power Supply Requirements 8 Approved Relays 8 Application Wiring Examples 9 Maintenance Repair Declaration of Conformity

Magnetically Coded Non Contact Switch Installation Instructions 3 1. Installation Instructions Installation must be in accordance with the following steps and stated specifications and should be carried out by suitable competent personnel. The unit is not to be used as a mechanical stop. Guard stops and guides must be fitted. Adherence to the recommended maintenance instructions forms part of the warranty. This device is intended to be part of the safety related control system of a machine. Before installation, a risk assessment should be performed to determine whether the specifications of this device are suitable for all foreseeable operational and environmental characteristics of the machine to which it is to be fitted. Refer to Technical Specifications for Certification information and ratings. ATTENTION: WARNING: The presence of spare actuators compromise the integrity of the safety systems. Personal injury or death, property damage or economic loss can result. Appropriate management controls, working procedures and alternative protective measures should be introduced to control their use and availability. Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel could result. 2. Technical Specification 2.1 Safety Ratings Standards EN188,ISO14119, IEC/EN6947-5-3 Safety Classification Dual contacts suitable for Cat.3 or 4 systems Functional Safety Data B1d: > 2 x 1 6 operations at min. Usable for ISO 13849-1:26 and IEC 6261. Data other than B1d is based on: Usage rate of 1p/1mins., PFH D : > 3 x 1 7 MTTFd: > 385 years 24 hrs/day, 36 days/year, representing 5184 operations Dual channel interlock may be suitable for performance per year. levels PLe or PLd (according to ISO 13849-1:26) and for use in SIL2 or SIL3 systems (according to IEC 6261) e: For up-to-date information, visit www.ab.com depending on application characteristics. Certifications CE marked for all applicable directives, culus, and TUV 2.2 Operating Characteristics (at rated temperature range) Make, minimum Break, maximum Sensing distance horizontal plane of operation 1mm 25mm Sensing distance vertical plane of operation 6mm 2mm Typical misalignment ±4mm (see Misalignment Graphs) Operational Current 3mA + 1 Maximum # of switches, connected in series Monitoring Relay Unit dependent (see Section 1) Operating Voltage 24V dc +1% / -15% (see Section 9) 2.3 Physical Characteristics Case Material Actuator Material Colour 2.4 Outputs Safety Output (Solid State Relay) iliary 2.5 Response Time Switch response time Series response time Maximum Frequency of Operation 2.6 Environmental ULTRADUR ULTRADUR Red 2 x N.C. 5mA 1 x PNP N.O. 2mA 5ms 5ms 1Hz Operating Temperature -1 +55 C (+14 +131 F) Operating Humidity 5% -95% relative Washdown rating / Enclosure type rating NEMA 3, 4X,,13, IP67, 68 & 69K Shock & Vibration IEC6868-2-27 3 g, 11ms IEC6868-2-6 1 55Hz E.M.C. EN 61-6-2, EN 6947-5-3 2.7 Protection Safety Output Short-Circuit Protection Provided by the approved safety Relays (See section 1) iliary Overload Protection Internal Resettable Fuse 24V Supply Reverse Polarity Protection Incorporated Electrical Life 1 x 1 6 cycles

4 Magnetically Coded Non Contact Switch Installation Instructions 3. Physical Dimensions - mm (inches) 48. (1.89) 22. (.87).5 (.65) 2. (.79) 5.5 (.22) 53 (2.1) 29. (1.14) Ø4.2 (.17) 48. (1.89) 22. (.87).5 (.65) 2. (.79) 5.5 (.22) 29. (1.14) Ø4.2 (.17) 4. Mounting Information Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not over torque the mounting hardware. It is recommended to use M3 screws and washers throughout. Position the switch and actuator so they are aligned with each other. 4.1 Mounting for Maximum Misalignment Mount the Sensor to the fixed part of the guard and the Actuator to the movable section. Keep the Sensor and Actuator within the sensing range detailed in section 4.4. e: Refer to Technical Specifications for Certification information and ratings.

Magnetically Coded Non Contact Switch Installation Instructions 5 To obtain maximum switching distance center switches +/- 4mm Actuator Sensor To prevent damage it is recommended that a 2mm gap be maintained between the actuator and sensor Actuator To prevent damage it is recommended that a 2mm gap be maintained between the actuator and sensor Actuator Sensor Sensor distance 8-14 mm To obtain maximum switching distance 8-14 mm For more detailed misalignment characteristics refer to the misalignment curves 4.2 Maximum Torque Specification - 1 N M (8.86 in lbs), use non-magnetic fixing hardware. 4.3 Minimum Distance Between Sensors - 5mm 4.4 Misalignment Curve 24 2 8 8 4 2 4 2mm Gap 8 4-4 -8 - - -2-24 2 2mm Gap 2mm Gap 8 4-4 -8 - - -2-24 24 2 2 8 4 8 2mm Gap 4 2 4-4 -8 - - -2 8-24 2mm Gap 2 4-4 -8 - - -2 8-24 e: To prevent damage to the MC2 it is recommended to leave a 2mm gap between the Sensor and Actuator. The maximum switching distance and misalignment tolerance will be obtained when the MC2 is mounted on non-ferrous material. Mounting the MC2 on ferrous/magnetic material will reduce the switching distances and tolerance to misalignment. 4.5. Direction of Approach e: Refer to Technical Specifications for Certification information and ratings.

6 Magnetically Coded Non Contact Switch Installation Instructions 5. LED Operation and Diagnostic Unit Indicators (per IEC 673) State Status Troubleshooting Off Powered Check supply, check wiring to controller A Device Output Off Overload Check AUX connections LED Red Actuator not present If actuator present check misalignment. Green Actuator Present NA Green Actuator Present Check wiring to controller flashing Actuation not present on other Check actuators on other switches switches or wiring fault 6. Troubleshooting 6.1 Series Circuit - 2 Guards Open S11 S21 24V 24V 24V 24V 24V S S22 LED - Green - OFF LED - Red - ON LED - Flashing Green - OFF LED - Red - ON LED - Flashing Green - OFF The auxiliary contacts close at the same time as the first safety contact opens 6.2 Series Circuit - Open circuit on channel A Open Circuit between two MC2s S11 S21 24V 24V 24V 24V 24V S S22 LED - Green - OFF LED - Green - OFF LED - Flashing Green - OFF LED - Flashing Green - OFF LED - Flashing Green - OFF The auxiliary contacts close at the same time as the first safety contact opens e: Refer to Technical Specifications for Certification information and ratings.

Magnetically Coded Non Contact Switch Installation Instructions 7 7. Connection Information 7.1 Wiring Diagram Pin # Wire Colour Signal 1 White PNP 2 Brown +24V 3 Green connected 4 Yellow 5 Grey 6 Pink 7 Blue V 8 Red connected 2 3 4 8 5 1 7 6 +24V Gnd 7.2 Recommended Mating Cable For 8-Pin micro (M) option. 889D-F8AB-*. Lengths are available up to 3m (98.4 ft) 7.3 Connection Table MSR1 family MSR2/3 Red/ S11 S11 Grey/ S S or S42 Yellow/ S21 S21 Pink/ S22 S22 or S52 Brown / +24V A1 / +24V A1 / +24V Blue / V A2 / V A2 / V e: When the MC2 is used with any MSR1 series Relay for the diagnostic function to operate correctly the Red and Grey wires () must be connected to S11 and S. e: Refer to Technical Specifications for Certification information and ratings.

8 Magnetically Coded Non Contact Switch Installation Instructions 8. Power Supply Requirements 24V dc +1%/-15% has to be supplied by a power supply that complies with IEC / EN 624 and IEC / EN 61558-1. Such a power supply meets the electrical safety requirements and maintains the minimum power of 2.4V dc during 2ms even in the event of voltage dips. When using an approved Relay with an MC2 and the same power supply is utilised for all devices the Relay will provide surge protection for the MC2. If a separate power supply is used for the MC2 then extra protection will be required. 9. Approved Monitoring Relay Units 1. MC2 can only be used with the approved Relays, use of other devices not listed is at the users own risk. 2. Only 24Vdc MSR Relays or MSR Relays configured for 24Vdc operation are compatible with MC2. 9.1 Approved Monitoring Relay Unit List and maximum number of series MC2s Monitoring Relay Series Catalogue Part No. Maximum number of MC2 units in series 24Vdc Supply Voltage MSR Series -5% -1% -15% MSR3RT/RTP 44R-N23197/44R-N23198 1 1 1 MSR 1 Series MSR1RT 44R-J23 8 - - MSR3RT 44R-J23 8 - - MSR4RT 44R-G2311/44R-G2318/44R-G2317 1 1 1 MSR6T/R 44R-N23117/44R-N233 1 1 1 MSR6.1T/.1R 44R-N23114/44R-N23 1 1 1 MSR7T/TP 44R-N236/44R-N23132 1 1 1 MSR7R/RP 44R-N239/44R-N23135 1 1 1 MSR131RTP 44R-C23139 1 1 1 MSR138DP 44R-M23151 1 1 1 MSR138.1DP 44R-M2384 1 1 1 MSR142RTP 44R-G232 1 8 - MSR144RTP 44R-C2325 1 1 1 MSR178DP 44R-M23227 1 1 1 MSR 2 Series MSR21P 44R-H23176 1 1 1 MSR22P 44R-H23177 1 1 1 MSR3 Series MSR32P connected to a 44R-W23218 1 1 1 MSR31 or MSR3 e: For up-to-date information, visit www.ab.com 9.2 Safety Ratings 1. An MC2 can achieve up to Cat 4/PLe, SIL CL3 when individually monitored by an approved Monitoring Relay Unit (see 9.1) that itself achieves Cat 4/PLe, SIL CL3. 2.. Two or more MC2 Sensors connected in series with an approved Relay achieves up to CAT3/PLd/SIL CL2. e: Refer to Technical Specifications for Certification information and ratings.

Magnetically Coded Non Contact Switch Installation Instructions 9 1. Application Wiring Examples 1.1 Single Switch, Automatic Reset, Monitored Outputs MSR7TP v + - + - +24V V A1 S11 S52 S 13 23 33 41 MSR7RP A2 S21 S22 S34 14 24 34 42 K1 K2 L1 L2 L3 MC2 Yellow Pink Red Grey e: To maintain correct diagnostic operation the red wire (QD pin 8) must be connected to S11. e: Refer to Technical Specifications for Certification information and ratings.

1 Magnetically Coded Non Contact Switch Installation Instructions 1.2 Multiple Switches, Automatic Reset, Monitored Output MSR7TP v + - + - v - v - +24V V Actuator in place LED Green Actuator in place LED Green Actuator NOT in place LED Red Actuator in place Flashing LED Green Actuator in place Flashing LED Green MC2 S1 MC2 S2 MC2 S3 MC2 S4 MC2 S5 Fuses + - + + - + A1 S11 S52 S 13 23 L1 L2 L3 Red Grey MSR7TP K1 K2 A2 S21 S22 S34 14 24 Yellow Pink v + - + - v + - + - Grey Red Grey Red Grey Red Grey Red Pink Yellow Pink Yellow Pink Yellow Pink Yellow 24 24 24 24 e: To maintain diagnostic function the Red (QD pin 8) wire from the first switch (S1 in this example) must be connected to S11

Magnetically Coded Non Contact Switch Installation Instructions 11 1.3 Multiple Switches, Manual Reset, Monitored Output MSR21P v v +24V V MC2 MC2 Fuses A1 S41 S22 S32 S S51 Y31 Y4 Y41 Y42 13 23 A2 S11 S42 S52 S62 S21 Y3 Y32 Y33 S34 Y1 Y2 RESET L1 L2 L3 K1 K2 Termination or Expansion Cable 14 24 31 32 Termination or Expansion Cable

Magnetically Coded Non Contact Switch Installation Instructions 11. Maintenance Every six months Check the correct operation of the switching circuit. Also check for signs of abuse or tampering. Inspect the switch casing for damage.. Repair Check the machine is isolated and stopped whenever the interlocked guard door is open. IMPORTANT: After installation and commissioning, the actuator, switch and hardware should be coated with tamper evident varnish or similar compound. If there is any malfunction or damage, no attempts at repair should be made. The unit should be replaced before machine operation is allowed. 13. Declaration of Conformity This is to declare that the products shown on this document conforms with the Essential Health and Safety Requirements (EHSRs) of the European Machinery Directive (98/37/EC Machinery Directive, 24/18/EC EMC Directive). These products also conform to EN 6947-5-3, EN 188, EN ISO 1 parts 1 & 2, EN 624-1 and have Third Party Approval. For a comprehensive certificate please visit: www.ab.com R Copyright 2 Rockwell Automation, Inc. All Rights Reserved.