Compact Intercom Server GE 100

Similar documents
GE 800. Digital IP-Intercom Server GE 800 DATASHEET

ET 908. IP-Intercom Module ET 908 DATASHEET PRELIMINARY

GE 800. Digital IP-Intercom Server GE 800. Datasheet

AUDIO... INTERCOMS...

Converter Box Data Sheet

Global Intercom Hardware

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

IP Desktop Intercom Stations 12 NIB 001 Series

Media Converters. Media Converters. Product Selection Guides

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Process displays For current and voltage

Digital Intercom Stations DTM Series

RS232 Control Box. Table of contents

Neon pr. ph/ ORP measurement. Applications. Description

USB Connectivity. USB Connectivity

ISDN PABX System. Installation Manual. Profi Line: AS 100 IT

LVX Control Unit. Features:

Junos WebApp Secure 5.0 Hardware Guide

GS202 Encoder Switch

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

DATA CONNECT ENTERPRISE

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Compact Coded Magnetic Safety Interlock Switch and Control Units

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

AC5160 SiPass integrated controller kit

MC 11 EB-2 Power supply cabinet with external bus, AC version

Manual Fiber Optic Interfaces

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Faults on the system Proximity switch connection technology:

Extension module for BACnet over Ethernet / IP and graphic Web functions

MCX06C Programmable controller

Connecting a Cisco Output Module

iologik 4000 Series (M) Modules

Industrial Media Converters

IP Intercom Systems for Homes and Apartments

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

duplex communication (with handset) hands-free talking simplex communication can be activated standard 4 (up to 2 from front-door stations)

MCS 50. Discussion Control Unit. 1 of 7

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *

Extension module for graphic Web functions for one automation station

RTU560 Remote Terminal Unit Connections and Settings

Enhanced Mini-Chansim Model VCS-232

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Quick Start Installation Guide

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

CAMit I Camera with built in Modem

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Breadboard & Digital Input/Output Modules

Advantages of a Full Featured 700 Series Relay

Extension module for Web functions generic

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

Priva Blue ID C-Line system overview

Installation Manual. Multi Power Controller MPC-1 multi-line D

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K

TCNM-ACBB1 Installation Manual

MID approval no. DE-08-MI004-PTB004 Date of release

M-Bus Central Unit. Use

Installing Sentor. Hardware Installation

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

KD-AMP220. Operating Instructions. 2 Channel 20 Watt Per Channel, Compact Digital Audio Amplifier

Connecting a Cisco Input Module

Sauter Systems

PI-EX-ME-2NAM/COC-120VAC

K-Module 544 for: AS 43, AS 45, AS 200 IT. Installation Manual

PCI Express 4-Port Industrial Serial I/O Cards

RMB Peripheral Units Installation Guide

Installation manual CF8-W-Disp-AL

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Features and Benefits. Certifications

Installation and Operation

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

S6 High performance Intercom Server for rack mounting

PI-EX-ME-2NAM/COC-24VDC

CA-A480-A Elevator Controller. Reference & Installation Manual

Continuous level measurement Ultrasonic controllers

Comprehensive Modular Genset Controller

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Installation / Control / Monitoring Technique

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Displays Transducers. Displays and transducers

RТTH DUAL ROOM SWITCH

COM32. Installation & Operation Manual

TM221CE24R controller M IO relay Ethernet

GmbH, Stettiner Str. 38, D Paderborn. M-Bus Modem

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

RangerBOSS Network Ready Constant Monitor Model CM2800

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

UNIVERSAL CURRENT CONVERTER

EA500. Installation Instructions Transponder

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

SPX-7400_SPX-7410_MAN_161028

DIRECT SELECT CONTROL CARD DIRECT SELECT I10 CARD

Transcription:

Datasheet 1 2 Compact Intercom Server Compact and easy to put into operation, the Intercom Server also offers a variety of features. Like a modern PC, it is equipped with interfaces to other communication systems such as video systems, door and gate control, telephone systems or also to another. The simple modular construction of the basic operating system facilitates upgrading for new applications and features. The latest SMD design results in the system being physically compact and conforming to the highest standards of electronic reliability. The features of the connected intercom terminals depend on the G1GET subscriber cards, which are available with three different feature levels (B, C and D). 1. Basic central including power supply, with 5 plugin slots. Slot 1 to for subscriber cards (1 to 16 subscribers) and/or interface cards. Slot A for interface cards only. The motherboard includes an AF input for music/alarm, 2 inputs for floating contacts, 2 relay outputs and a socket for (remote) programming or maintenance. 2. (bottom) with (top) Expansion central including power supply, with 5 plugin slots. Slot 5 to 8 for subscriber cards (17 to 32 subscribers) and/or interface cards. Slot B for interface cards only. Datasheet Version 3.0/1207 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 1 6

Technical Data Benefits Technical Data AC power supply: DC power supply: 2 V ±5% / 0 VA / 16 subscribers 2 35 V / 0 W / 16 subscribers Emergency power consumption: 200 mah/h (without cards) cards see corresponding data sheet Power consumption: Frequency range: minimum (no conversation): 8 VA, maximum (all call): 0 VA internal 300 16,000 Hz Distortion: less than 0.9% Operating temperature range: 0 C to 50 C (32 F to 122 F) Storage temperature range: 30 C to 60 C ( 22 F to 10 F) Relative humidity: 20% to 80% Measurements of the housing: Weight including package: Mounting: Relay outputs: Music input: Inputs IN1, IN2: 310 x 210 x 77.5 mm (12.21 x 8.27 x 3.05 inch) : 2280 g (5.03 lbs) : 2230 g (.92 lbs) wall mounting max. switching capacity: 60 W / 125 VA, max. switching current: 2A max. switching voltage: 60 VDC / 0 VAC max. 800 mv at 600 Ohm for floating contacts, max. line resistance: 1.5 kohm Benefits Compact plastic housing suitable for wall mounting Easy installation and startup Over 150 standard features (a detailed list is available separately) Latest intercom technology: microprocessorcontrolled, high density design, SMD production, object orientated programming Integrated functions for door/gate control, alarms, conferences and central control desks Plug&Play CCTV integration Flexible expansion by means of different feature packages Wide range of applications Userfriendly programming with PC software (included in extent of supply) Remote programming via modem Connection of several central units via tieline Expansion Subscribers: Outputs: Inputs: Basic expansion: 0 2 2 Maximum expansion: see Plugin Position of the Cards Extent of Supply 1 Intercom Server in basic expansion, including: Power supply CD Software & Manuals Datasheet Version 3.0/1207 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 2 6

Precautions With regard to the CE mark, the central is suitable for the following types of application: residential buildings, office and commercial premises, small businesses and industrial premises with public lowvoltage mains supply. Defective power cables of the transformer may not be repaired or changed. In case of defective power cables, the whole transformer must be changed. Mounting and installation of the central and of the equipment may be carried out by authorised service personnel only. Cards may be inserted or removed only with voltage switched off. Before exchanging of cards, ESD precautions must be observed. The terminal of the motherboard G1GEM (see Mounting, Cable Run at page 5) is used as grounding point for Wrist Strap Grounding. Programming Cable For programming of the the following cable is required: Speech Channels Available per (incl. ): 2 Duplex controllers 12 Analogue audio lines The different types of conversation require a different number of audio lines, the free lines are allocated dynamically (see below). Required Lines Duplex controllers Analogue audio lines Max. conversations (incl. GEZ) Simplex 1 12 Switched 1 2 Full duplex 2 6 Feedin of audio signals* 1 12 channels * Features like feed in of music programs, conferences or radio conferences. For music T1 none of the mentioned lines are required (internal music bus). 1 2 3 5 2 5 5...GND (7) 3...TXD (2) 2...RXD (3) 7...RTS () 8...CTS (5) 9way 25way Remove the Cover Press here to remove the cover 1 3 PC Programming plug central The following cables, available as accessories, can be used for programming of the : XKAB100 (with yellow sleeve) XKABCOMWIN (with red sleeve) XKABKOFFER (with white sleeve) Datasheet Version 3.0/1207 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 3 6

Plugin Cards for Subscriber cards: G1GETB, C, D: for four wire intercom stations Input/output cards: G18E8A: 8 inputs for floating (voltfree) contacts and 8 floating (voltfree) relay contacts G116A: 16 outputs (floating (voltfree) relay contacts) G116E: 16 inputs for floating (voltfree) contacts Interface cards G1V2: V2 interface card with two RS 232, of which one can be configured as RS 22 G1TEL: analogue telephone interface Connection cards: G1GEL: tieline card for one leased line connection to another central, optional 2wire or wire Plugin Position of the Cards The plugin cards can be inserted in the following slots: Maximum number of cards Card type A 1 2 3 B 5 6 7 8 max. per max. per G1GETB, C, D G18E8A G116A G116E together 2 together 2 G1V2 1 1 G1TEL together 1 G1GEL 2 2 Datasheet Version 3.0/1207 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 6

Mounting, Cable Run Expansion Central 180 mm (7.1 inch) 206 mm (8.1 inch) max. 120 mm (.7 inch) 110 cm (.3 inch) Grounding point for wrist strap grounding 30V A B C D Cable bearer / / / 110 cm (.3 inch) Modular socket 8/8 2VAC supply Datasheet Version 3.0/1207 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 5 6

Connection Diagram Slot number B 5 6 7 8! Music / Alarm input Floating contacts No subscriber cards in the interface slots (A,B) Expansion plug Programming plug MUSIK IN1 IN2 S1 S2 ON OFF DIP switches Interface slot (e.g. G18E8A ) Interface slot (e.g. G18E8A) E.g. G1GET e.g. G1GET 13 12 11 10 53 52 51 50 E.g. G1GET E.g. G1GET 23 22 21 20 63 62 61 60 Slot number A 1 2 E.g. G1GET E.g. G1GET 33 32 31 30 73 72 71 70 3 E.g. G1GET E.g. G1GET 3 2 1 0 83 82 81 80 Subscriber numbers with standard programing Subscriber numbers with standard programing 30V Status LED 30V Power ON OFF optionally: output max. 100mA supply optionally instead of optionally: output max. 100mA supply optionally instead of e.g.: Door opener Power supply A B C D Datasheet Version 3.0/1207 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 6 6