Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

Similar documents
PROXPRO WIEGAND/CLOCK-AND-DATA INSTALLATION GUIDE

REVISED PER ECO #E

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

Indala Reader Installation Guide

MS-3000 MicroStar Reader

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

DWG DESCRIPTION IRVINE, CALIFORNIA MANUAL, INSTALL, HID MIFARE READER REVISIONS INITIAL RELEASE PER EO #E6055-7

MS-7000: SuperStar Reader

MS-5000: MiniStar Reader

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Installation Manual Rev E MaxiProx Wiegand Reader 5375A

Installation Instructions RF5010 and RF5210

iclass INSTALLATION GUIDE

Pyramid Series Proximity Readers

MS-4000: ShootingStar Reader

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

Installation Instructions RF5010 and RF5210

Satellite INSTALLATION GUIDE

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

MECHANICAL ELECTRICAL CONNECTIONS. * Index (Z) optional. See Ordering Information

2000 Series e/em Style Keypad Installation and Programming Manual

rcc.1081 Installation Instructions

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

Parts 1 - Reader and base plate assembly 1 - Installation guide 2 - Terminal connector - terminal readers only

1.0 Wiring and Layout Diagrams

PanelView Plus/VersaView CE Terminals and Display Modules

MobileView Junction Box

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

Infosystem Remote Touchscreen Installation Instructions

Inductive Proximity Sensors E51 Limit Switch Style, Modular

Security Expert Smartcard Reader Mini

Quick Start Installation Guide

Ultrasonic Analog Output Sensors

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

FlexPass TM Advantage Series Proximity Plus TM ASR PowerProx TM Reader User Manual

Ultrasonic Analog Output Sensors

Smart Wireless THUM Adapter

ENTRACOMP 26SA With Remote Open Input. User/Installation Manual

KP2000E/EM Series Style Keypad

GE Contactless Reader Models 240/245/250 Installation Guide

Volume. EverAccess. Instruction Manual

Bulletin 800Z Zero-Force Touch Buttons

GV-Card Reader. User s Manual

Micro Motion. Series 3000

FLEX Ex Spring Clamp Terminal Base

HEAVY DUTY INCLINOMETER ANALOG & RS232 INTERFACE

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

232iLM Keypad Installation and Programming Instructions

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

MODEL 8000MP LEVEL SENSOR

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

Custom Controller Installation Instructions

SINGLE READER EXPANSION MODULE

Absolute encoders - SSI

Photoelectric Sensors Comet Series

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader

Mifare ID Reader. with selectable outputs

Installation Notes TII Model 341 Protector

955S BRIK. Series 955S Brik. Smart BRIK LDT ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS. Linear Displacement Transducer

Photoelectric Sensors Comet Series

Miniature Inductive Prox TL-W

Quick Start Installation Guide

Wireless General Purpose Adapter (WGA100) Installation Instructions

Installation Instructions

Material: Weight: Shaft Loads: Cable: Connector:

Proximity Card and Pin Reader Installation Manual

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

MRDT Display Terminal

COR Series Router IBR900/IBR950 AND IBR1100/IBR1150

REX F-0-9 Standalone or Access Controller

CompactBlock Guard I/O EtherNet/IP Safety Modules

Gallagher T20 Reader. Installation Note. The Gallagher T20 Reader

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

GV-RK1352 and GV-R1352 Card Reader

PXL-250 Tiger Controller

Product Manual Pushbutton Station for Modicon Programmable Controller MODBUS Interface

COMPACT30 Warning Tower Lights - General Description...J17 Complete Assemblies...J19 Accessories...J20 Technical Information...J21

EL-ST100 KEYPAD CONTROLLER

TruPortal Dual Door Interface Module Quick Reference

7511 / / / 711 / / 731 / Preset 27

IB080QM65VA3 Part Number

Micro Motion MVD Direct Connect Meters

Aceprox FSK Proximity Reader REV2 Data Sheet

Model DMX8DIM Installation and Operations Manual

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

XBR V4 INSTALLATION AND USER GUIDE

General-Purpose Photoelectric Sensor

Color Mark Photoelectric Sensor E3S-VS

6222 Two Door Module Technical Operations Manual

Installing a Power over Ethernet injector

4100/ VDC Converter Installation Instructions

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Safety Light Curtains GuardShield Remote Teach

Inductive Proximity Sensor

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)

INSTALLATION INSTRUCTIONS

Transcription:

Installation Manual - 5365-902 Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 1 of 7

MiniProx Reader Installation Manual System Overview The MiniProx Reader is a self contained proximity Reader, frequently used in Access Control Systems. The antenna and all associated electronics are assembled in a polycarbonate housing. The Reader contains a micro-controller unit that controls an RF field that is generated at 125kHz. The Reader has a sensitive receiver circuit that detects ID card data and passes it along to the micro-controller for decoding. The Reader output is configured in the "Wiegand" style electrical interface for model 5365B and Clock and Data style interface for model 5368B. The Reader has a single Bicolor LED that will emit red, green or amber colors. Installation of the MiniProx Reader consists of mounting the Reader and connecting the cable to the Host via the Pigtail or Terminal strip. Operation Access Cards are to be presented to the front of the Reader. The LED is red when ready to read an ID card. The LED turns green when the card is read and a message is transmitted to the Host computer or interface panel. When the system is ready for another card, the LED returns to red. The LED is flashed green and the Beeper is activated for 250 milliseconds when they are controlled by the internal microcontroller. The operation of the LED and beeper is often controlled by the Host panel. If Host controlled, the operation will deviate from Host to Host. The MiniProx may be configured in the dual LED control line that allows individual control of both the red and green colors of the LED. Parts List Quantity 1) MiniProx 1 (included) 2) #6-32 x 1" self tapping, Type T or 23 2 (included) 3) This Installation Sheet 1 (included) 4) Wire Splice 9 (installer supplied) 5) Grommet 1 Recommended (installer supplied) 6) DC Power Supply 4.75 to 16VDC, 50mA 1 (installer supplied) 7) Cable, 5 conductor, 22 AWG Up to 500ft. (installer supplied) Alpha 1295C See Cable Notes 8) Box, Hazardous 1 (included on hazardous units only) Installation Procedure: (excluding hazardous unit) 1. Determine an appropriate mounting position for the Reader. Drill two 7/64th (.109) Inch holes for mounting the Reader to the surface (see figure 1). Drill a 3/8 to 1.0 Inch hole for the cable. Place a grommet around the edge of the hole. Route the interface cable from the Reader and/or power supply to the Host. Check all electrical codes for proper cable installation. 2. There are two types of the MiniProx available, the MiniProx - Pigtail style has a 18 10 conductor cable, and the terminal strip MiniProx has a 10 conductor terminal strip for all the connections. See the diagrams of each type below. a. Pigtail - For the pigtail version, prepare the new cable by cutting the cable jacket back 1-1/4 and strip the wires ¼. Splice the cable and the pigtail together and seal the splice. Trim and cover all conductors that are not used. b. Terminal strip - For the terminal strip version, Loosen the terminal strip screws all the way out, until the top of the screw is flush with the back surface of the MiniProx. Be careful to not turn them out further, as they are not captive, and will fall out. Prepare the new cable by cutting the cable jacket back 1-1/4 inches and strip the wires ¼. Twist the ends of the wires to eliminate stray strands. Form each wire into a hook, and install each wire by wrapping it around the screw. 3. Connect the Reader and Host together according to the wiring diagram with figure 3 and the Host installation guide. The legend for wiring is color coded (according to the "Wiegand Standard") for the Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 2 of 7

recommended cable, but marking the wires will make future maintenance easier. The numbering for the terminals is also shown on the back label as well as in the diagram below. 4. After wiring the Reader and power supply, the Reader is ready to be tested. Power up the Reader and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one long delay. This indicates that the micro-controller unit is working properly. Present an ID card to the Reader and the LED should momentarily turn green, indicating a read of the card. If the Reader LED is controlled by the Host refer to the Host description of the LED operation. 5. Mount the Reader with the provided screws when mounting onto metal mullions or junction boxes. On other materials use the appropriate fastener. Dimension Diagrams, front and side views TOLERANCES:.XX +/-.03".XXX +/-.010" STANDARD HOUSING THIN HOUSING 2 PLCS,.172" 2 PLCS,.300" COUNTERBORE 5.25" 6.00" 1.00" 0.75" 1.70" FIGURE 1 Installation Procedure: (hazardous unit) Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 3 of 7

1. Determine an appropriate location for the junction box. Attach the junction box to the mounting surface using the 4 holes shown in figure 2. 2. Route conduit and cable to the junction box per National Electric Code Article 720-2. Provide enough cable length to allow wiring of the reader assembly outside of the junction box. Route wiring from junction box through the center hole of the junction box cover. 3. Loosen the terminal strip screws until there is sufficient room to wrap a wire around the screw post. Prepare the cable by cutting the cable jacket back 1-1/4 inches and strip the wires ¼. Twist the ends of the wires to eliminate stray strands. 4. Connect the Reader and Host together according to the wiring diagram with figure 3 and the Host installation guide. The legend for wiring is color coded (according to the "Wiegand Standard") for the recommended cable, but marking the wires will make future maintenance easier. The numbering for the terminals is also shown on the back label as well as in the diagram below. 5. After wiring the Reader and power supply, the Reader is ready to be tested. Power up the Reader and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one long delay. This indicates that the micro-controller unit is working properly. Present an ID card to the Reader and the LED should momentarily turn green, indicating a read of the card. If the Reader LED is controlled by the Host refer to the Host description of the LED operation. 6. Mount the junction box cover to the junction box and mount the Reader to the cover with the provided screws. 3.46 2.37 8.50 FIGURE 2 Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 4 of 7

R R Back view, Terminal Strip and Pigtail HID CORPORATION MiniProx TM 10 U.S. PATENT NO. 4,730,188 C 1996 HID CORPORATION HID CORPORATION MiniProx TM U.S. PATENT NO. 4,730,188 C 1996 HID CORPORATION 2.00" + + 10 9 8 7 6 5 4 3 2 1 CARD PRESENT (VIOLET) HOLD (BLUE) BEEPER (YELLOW) RED LED (BROWN) GREEN LED (ORANGE) SHIELD GROUND (DRAIN) DATA1/CLOCK (WHITE) DATA0/DATA (GREEN) GROUND (BLACK) 4.75-16 VDC (RED) 10 9 8 7 6 5 4 3 2 1 CARD PRESENT (VIOLET) HOLD (BLUE) BEEPER (YELLOW) RED LED (BROWN) GREEN LED (ORANGE) SHIELD GROUND (DRAIN) DATA1/CLOCK (WHITE) DATA0/DATA (GREEN) GROUND (BLACK) 4.75-16 VDC (RED) 1 LISTED ACCESS CONTROL SYSTEM UNIT ACCESSORY.REFER TO OPERATORS MANUAL 5365-902. ELECTRICAL RATING: 5VDC/40mA, 12VDC/50mA 8T29 CLASS I, DIVISION 2, GROUPS A-D, HAZ LOC :T4. FCC ID: JQ6536X This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference recieved, including interference that may cause undesired operation. LISTED ACCESS CONTROL SYSTEM UNIT ACCESSORY.REFER TO OPERATORS MANUAL 5365-902. ELECTRICAL RATING: 5VDC/40mA, 12VDC/50mA 8T29 FCC ID: JQ6536X This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference recieved, including interference that may cause undesired operation. FIGURE 3 Wire Connections 1 2 3 4 5 6 7 8 9 10 +DC Ground Data0 Data1 Shield Ground Green LED Red LED Beeper Hold Card Present Red Black Green White Drain Orange Brown Yellow Blue --- Cable Notes 1) Wiegand - +DC, Ground, Shield Ground, Data0 and Data1 are required for Wiegand Operation. All others (Green LED, Red LED, Beeper and Hold) are optional. 2) Clock and Data - +DC, Ground, Shield Ground, Data, Clock, and Card Present are required for Clock and Data Operation. All others (Green LED, Red LED, Beeper and Hold) are optional. Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 5 of 7

3) When using a separate power supply for the MiniProx, the power supply and Host should have a common ground (voltage reference). 4) If the Host is controlling the beeper, Hold, or the LEDs are configured for the dual LED mode, additional conductors will be required. The recommended cables are Alpha 1295C, 1296C, 1297C, 1298C and 1299C that are five, six, seven, eight and nine conductors respectively. Larger wire gauges are acceptable. The wire is to be stranded with an overall shield, either foil or braided. 5) The Cable shield should be connected to the Shield Ground on Reader TB1-5, and left floating at the panel or power supply end of the cable. This configuration is the best for shielding the reader cable from external interference and reducing the likelihood of the Reader causing interference. Product Configuration/Ordering Options 536X B X X XX -XXXX Y Customer Custom Artwork or Firmware Number - 1 through 9, A through Z Customer Custom Number Configuration Options - (00 standard) Standard Hardware Options - H = Hazardous, P = Pigtail, T = Terminal strip Color - G = Gray, B = Beige Current Revision Letter Model Number 5365 = MiniProx Wiegand 5368 = MiniProx Clock and Data Reader Standard Wiegand Part Number = 5365BGP00 is a MiniProx, Wiegand, Gray Standard (1 ) housing, Potted, with 10 conductor, 15 Pigtail. Standard Clock and Data Part Number = 5368BGP00 is a MiniProx, Clock and Data, Gray Standard (1 ) housing, Potted, with 10 conductor, 15 Pigtail. Option numberconnectionshousingpotting 1 Terminal stripstandard HousingNon-potted 2 PigtailStandard HousingNon-potted 3 PigtailThin HousingPotted 4 PigtailThin HousingNon-potted Product Specifications Read Distance Overall Operating Limits (12VDC - minimum) 4.00 inches (10.2 cm) Non-Metallic Mounting (12VDC - typical) 5.0 inches (12.7 cm) Mounted on Metal (12VDC - typical) 5.0 inches (12.7 cm) Overall Operating Limits (5VDC - minimum) 2.5 inches (6.3 cm) Non-Metallic Mounting (5VDC - typical) 3.0 inches (7.6 cm) Mounted on Metal (5VDC - typical) 3.0 inches (7.6 cm) Regulatory Requirements (applied for) Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 6 of 7

Underwriters Laboratories listing under UL 294, Access Control Unit Accessory Underwriters Laboratories listing under UL 1604, Electrical equipment for use in Class I and II, Division 2 and Class III Hazardous (Classified) Locations UK and Germany National Type Approvals CE Mark - See letter of Conformance FCC certification Environmental Characteristics Designed for listing under UL 294 Standard for Access Control System Units Operating Temperature Range -30 o C to 65 o C (-22 o F to 150 o F) Storage Temperature Range -40 o C to 85 o C (-40 o F to 185 o F) Operating Humidity Range 5% to 95% non-condensing Operating Vibration Limit.04 g 2 /Hz 20-2000Hz Operating Shock Limit 30g, 11mS, Half Sine Potting Material UL Recognized Filled Polyurethane Enclosure Material UL Recognized Lexan Polycarbonate Potted Weight - Terminal Strip/Pigtail 7.2oz (202gms) / 8.2oz (228grms) Power Requirements Power supply Linear type recommended Operating Voltage Range (+DC) 4.75VDC -16.0VDC Absolute Maximum (+DC non-operating) 18.0VDC Maximum Average Current 5V/12V 40mA/50mA Transient Protection (all terminals) 8,000 volts Reverse Voltage Protection YES Input Voltage (maximum data-0/1 lines) 16.0VDC Input Voltage (maximum interface lines) 16.0VDC Operating Parameters Excitation Frequency 125KHz Duty Cycle (alternate power level rate) 20% @ 60mS period Read and Report Speed (26 bit Wiegand Card) 175mS Maximum Cable Distance to Host 500 feet (152 meters) LED Type Bi-colored Red/Green LED Operation (host control of red/green).5v on LED control line Beeper Operation (host control).5v on beeper line LED Control (default) internal/single Beeper Control (default) Beeper enabled Anti-Pass Back Delay (default) 1 second Wiegand Data Pulse Widths (default) 40uS Wiegand Data Interval (default) 2mS Clock and Data Clock Bit time (default) 1.5mS Clock and Data Clock/Strobe Pulse width (default) 500uS Clock and Data Card Present Valid (default) Data Frame plus 1mS NOTES: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES. ALL LOCAL, STATE AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE. Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 7 of 7