Minneapolis Blower Door Building Air tightness Testing Systems

Similar documents
Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door

Please send completed forms by to: Shipping Address (if different than Billing Address): Contact Name: Company Name: Street Address:

TEC WiFi Link and Updated itec-700 ios App

CONSERVATORY. The ENERGY. TECTITE (Ver. 4.0) Software User s Guide. (Building Airtightness Test Analysis Program)

Comparison between Retrotec and Minneapolis Gauges

Field Calibration Check Procedure Minneapolis Duct Blaster System (with DG-700)

Speed Control Adapter

Minneapolis BlowerDoor Measurement Systems

rev Operation Manual Software FanTestic (ASTM)

Price List. System Description List Price Image DE V/50Hz DucTester 2, case, 20 ft (6m) umbilical and hard panel

itec-700 for PC (The itec-700 App is also available for both ios and Android devices.)

[ Capture Hoods. What is a capture hood?

rev Operation Manual Software FanTestic (Duct Testing)

FlowBlaster. Operation Manual. Attachment for the Minneapolis Duct Blaster Fan and DG-700 Pressure and Flow Gauge

Model 90. thermwood. Thermwood CNC Machining Centers. Machine Features Shown

BlowerDoor. Standard. Minneapolis BlowerDoor Modell 4.1 with DG-1000 TECTITE Express version 5.1

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

rev Operation Manual Software FanTestic (EN13829 Europe)

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

New Model Fact Sheet

Dräger UCF 6000 Thermal Imaging Camera

STANDS Speaker Television. All-Steel Speaker Stand SS7725B (page 82)

Operation Manual. rev Charge then remove battery when stored for more than 1 week. Flow Finder MK2. Powered Flow Hood

MICROPHONE stands & accessories

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

What is new at The Energy Conservatory?

Flow Finder MK2 Powered Flow Hood

Dräger UCF 9000 NFPA Certified Thermal Imaging Camera

Free-Standing Type 12 Enclosures

FX 3300 Air Permeability Tester III Scope

OPEN FACE Industrial East Grand Ave., Pomona, CA Fax:

UltraRack. Advanced Data Centre Enclosures SR SERIES

Smart flow meter. Smart phone. Smart idea.

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

Prepare your EPIC for action.

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

ROLLER SHUTTER LOUVER WINDOWS. Contact us now for more information on Thailand or visit us at

PRODUCT OVERVIEW. Well Inspection Cameras & Systems. See what you re missing. Proudly made in the U.S.A.

PRODUCT OVERVIEW. Well Inspection Cameras & Systems. See what you re missing. Proudly made in the U.S.A.

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

CHORE-TRONICS 3 Whole House Controller

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

Precision for People. SNAPFamily of Products

Air Permeability Tester FX 3300 LABOTESTER III

Air Moving Solutions. axipal adjustable pitch airfoil fans

DIGITUS Server Cabinet Unique Series

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

HPX-PRO. For Non-Destructive Testing. THE ANSWER TO PORTABLE DIGITAL NDT.

IC CONES TRAFFIC CONES TRAFFIC CONES CONES TRAFFIC TRAFFIC C ONES TRAFFIC CONES TRAFFIC CONES TRAFFIC CONES TRAFFIC CONES TRAFFIC CONE

VRX & VR12. GrainVac

4520 Soft Case for Brochure Stand $ $ Hard Case for Brochure Stand $ $ 73.50

kena TM Instruction Manual T-1050

Brasch Washdown Unit Heaters

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

SD Series Cord and Light Reels

MPT-250C Wire Crimp Pull Tester

R u b b e r d i s t r i b u t o r

da Vinci Super Quick Guide da Vinci Super Safety Precautions Product instructions Unboxing and Installation Product specification

Operation Manual. rev Software. FanTestic (ATTMA) Retrotec Inc.

Product Overview. Features

The Most Advanced Racking Solutions Available!

Navigator Series. The Only Scale in its Class with Touchless Sensors That Free Up Your Hands! Portable Scales. Standard Features Include:

TV & Office Solutions by equip solutions with a high value of benefit

F&J SPECIALTY PRODUCTS, INC.

ITB THROTTLE WITH INTEGRATED STEPPER MOTOR INSTALLATION INSTRUCTION

XL-80 spares list. Application note. Overview

AUW-D/AUW/AUX/AUY Series

LIGHTWEIGHT TRIPOD 190D, 190CL, 190PRO, 190NAT3, 190MF3, 190MF4 SUGGESTED HEADS. Ball Head. Two way Head. Three Way Head. Geared Head 390RC2 460MG

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Roller Shutter Door Kits. Diversity in profiles

kena Instruction Manual T-1050

130 Salt Contamination Meter

Model VDL 115 Vacuum drying chambers for flammable solvents

QuickSpecs. HP Carrying Cases Overview. HP Basic Notebook Case. DA Worldwide Version 9 September 1, 2008 Page 1

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

IRIS Damper Application Guide

SICO Tri-Height Mobile Folding Stage System. A dual or triple height adjustable stage with reversible deck.

DL1000 DURABILITY & LUBRICITY TEST SYSTEM

2017 Store. Transport. Secure.

Company, Simplex Onsite, providing nationwide load bank rentals.

TABLE OF CONTENTS INTRODUCTION 3 BENEFITS AND USES 3 PRODUCT INFORMATION 4 PRODUCTS INFORMATION 5-8 PART NUMBERS AND DESCRIPTION 9 WARRANTY POLICY 10

Iso Floor for Electrical Equipment Rooms

Assembly and Maintenance

IS-3000-LS-ABB INFRARED SCANNER

Fast-paced. Travel-ready.

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

DP DP2500 DP0250

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

Laboratory Exhaust Systems

Dräger UCF 8000 NFPA Certified Thermal Imaging Camera

Product Information. Wheel Distance Measurement Unit HGE-WD HGE-DataManager Software. with Handheld Computer PSION WORKABOUT

A Product of

Pros demand of Tripods, Heads and Support Accessories. And INDURO delivers with a wide and growing range

Connectivity Products

Terminal Accessory Guide

2009 Tripod Range. Luben Solev w w w. g i o t t o s - t r i p o d s. c o. u k

Transcription:

DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE ENERGY CONSERVATORY The Blower Door Minneapolis Blower Door Building Air tightness Testing Systems

Minneapolis Blower Door Blower Door tests are used to measure the airtightness level of building envelopes, diagnose and demonstrate air leakage problems, estimate natural infiltration rates, estimate efficiency losses from building air leakage, and certify construction integrity. For more than 25 years, the Minneapolis Blower DoorTM has been recognized as the best designed and supported building airtightness testing system in the world. Combined with specialized accessories and complete testing procedures developed by The Energy Conservatory (TEC), The Minneapolis Blower Door is the system of choice for building science trainers, utility programs, energy raters and auditors, HVAC contractors, builders, insulation contractors and weatherization professionals. Minneapolis Blower Door Features Precision Engineered, Calibrated Fan Lightweight and rugged injection molded fan housing. Quick and accurate flow measurements from 300 to 6,100 CFM (141 to 2,879 l/s, 510 to 10,364 m3/h). Optional rings C, D and E will measure down to 11 CFM (5 l/s, 19 m3/h). Powerful 3/4 hp motor provides continuous flow for testing and air sealing work. Solid state variable speed fan control. Compatible with both pressurization and depressurization testing. Both 110V and 220V models available. Accurate, Powerful Digital Gauge DG-700 Pressure and Flow Gauge contains 2 precision pressure sensors to provide simultaneous display of both building pressure and Blower Door fan flow readings. Auto-zeroing of both channels eliminates sensitivity to orientation and temperature. Specialized @50 and @25 test modes make it simple to conduct one-point airtightness tests of buildings and duct systems. Test results can be displayed in CFM or square inches of leakage area. Cruise 75, 50, 25 and 0 Pa building pressure without connection to a computer. The Cruise Control feature automatically adjusts the speed of the Blower Door fan to maintain a constant building pressure while you perform additional diagnostics or air-sealing procedures. Four separate time-averaging modes (1, 5, 10 second & long-term) allow you to accurately measure fluctuating pressures. Baseline feature allows the user to measure and record a baseline pressure reading, and then display the baseline adjusted reading. The DG-700 can be used along with a computer and specialized TEC software: TECTITE to conduct automated Blower Door tests; and TECLOG2 for data logging of pressure measurements and large building airtightness tests. The DG-700 has both a USB and a serial port for connection to your computer. Automated Testing Accessories Included With Every System Automated testing provides computerized control of the Blower Door fan and automated capture of the building pressure and fan flow measurements. This feature reduces operator error, ensures that tests are conducted the same way every time, and improves test accuracy in windy weather. Automated testing accessories include: TECTITE Software Fan Control Cable. USB Cable to connect the Blower Door system to your laptop computer. Testing of large buildings with multiple fans and gauges is done with our TECLOG2 software. (Can be downloaded at no-charge from our website) 2012 The Energy Conservatory DG-700 Pressure and Flow Gauge with Cruise feature

A n a to my o f t h e M i n n eapol i s Bl owe r D oor Lightweight, Durable Door Frame and Panel This innovative design is the result of years of refinements based on the experience of thousands of users. There is no easier way to seal a Blower Door fan into a door opening. Snap-together aluminum frame comes in a compact case and sets up in seconds. Precision cam lever mechanism securely clamps the nylon panel into the door opening. Fits an 8 foot door without special parts. DG-700 Pressure and Flow Gauge Specifically designed for airtightness testing with specialized measurement functions. One of the best all around pressure measuring gauges on the market. Built-in Cruise Control feature with settings for 75, 50, 25 and 0 Pa. Channel A measures the change in building pressure. Channel B measures air flow from the Blower Door fan. DG-700 can be connected to a laptop computer for fully automated testing. (Both USB and serial ports included.) Fan Speed Controller Precision control of fan speed throughout the entire range. Fan Control port for Cruise Control and automated testing. Fan cooled controller is easy to handle and improves the life of the controller. Powerful, Calibrated Fan The 3/4 hp motor of the Minneapolis Blower Door Fan is designed to maintain accurate flow for hours while you work. Accuracy of the Blower Door Fan and DG-700 Gauge is +/- 3% down to 85 CFM. No special calibration or extra charges required. The Blower Door Fan comes with Rings A and B to measure a wide range of airtightness conditions. Optional Rings C, D and E extend the low range of the Blower Door fan. Precision readings from 11 CFM to 6100 CFM.

Multi-fan Blower Door Systems Airtightness testing of larger buildings requires more fan flow. The Minneapolis Blower Door can be configured to install 2 or 3 fans in a single doorway, making it possible to measure the airtightness of almost any size room or building. Very large or complex buildings may require more than a single door location. Our TECLOG2 software is designed specifically for multifan and multi-gauge testing in large buildings. TECLOG2 provides a master control for all fans, as well as individual fan control. All data from each gauge is captured by a single computer and airtightness test results can be displayed onscreen or exported for use by other software. The Energy Conservatory All of our products come with a full two year warranty on parts and labor, and access to the most knowledgeable customer service staff in the industry. When your personnel have questions on the use of our products or how to handle unusual situations they encounter, you can count on us to give dependable answers. We always stock a complete line of replacement parts and can respond quickly to any service or equipment problem. Our nearly 30 years of expertise goes beyond simply knowing our equipment. The Energy Conservatory s on-going research, active participation with technical associations, and close working relationship with the world s leading building scientists has kept us actively involved in the development and field testing of many of the techniques currently being used in the performance testing industry. This experience ensures that our customers always have the most up to date information and testing procedures.

Blower Door Accessories/Options TECTITE Airtightness Test Analysis Software Calculates building airtightness test results including leakage areas, ACH50, CFM50, building leakage curve, estimated natural and design infiltration rates and the estimated savings of air sealing. Includes the 3 new RESNET Blower Door test standards (auto and manual) in addition to the CGSB standard. The zonal pressure feature can be used with multiple DG-700 gauges Compatible with both manual Blower Door tests and automated tests using a DG-700 or APT System. Calculates mechanical ventilation requirements in accordance with updated to ASHRAE 62.2-2010.. Easy to use data entry screens, file storage and file retrieval features. Choice of report formats including an easy to read homeowner report or a detailed technical report. along with a built-in pdf file report generator. Included with each new Blower Door kit and available for free download. TECLOG2 Data Logging Software Datalog values from up to 16 gauges or APT Systems. Control each individual fan or all fans simultaneously. (Total number of fans controlled and measured is based on available number of pressure channels.) Calculate and display multi-fan airtightness test results, ideal for testing in large commercial buildings. Data viewing capabilities include auto-axis rescaling, adjustable graph scrolling, quick graph zooming, and a moveable measurement line for determining the numeric value and time for individual data points. A statistics utility can be used with stored data files to provide basic statistical summaries for the entire file, or for a user selected portion of the data. Laptop Computer Stand Using a computer stand increases the stability of your laptop while conducting a Blower Door test. This collapsible laptop stand can be taken anywhere. Minimum height is 15 inches and extends to a height of 27 inches. The detachable top is 11 x 13 and has a non-skid surface that helps keep the laptop computer in place. Smoke Puffer A convenient source of white smoke for diagnosing air leakage sites. The smoke puffer consists of a small 3 inch (7.6 cm) high Teflon bottle and 2 vials of chemical smoke. The smoke puffer will last for several months and can be easily refilled. Fan Cases The Standard Minneapolis Blower Door System does not come with a fan case. The rugged and durable fan can handle transport in a car or minivan without any further protection. If storing or transporting the fan in a panel or delivery style truck, a fan case is suggested. Our lightweight, heavy duty, water resistant nylon case provides excellent protection from dirt and scratches. The Padded nylon case is made of the same tough material as our lightweight fan case, but also includes plenty of high density foam to protect your Blower Door fan from the bumps and bangs of everyday use. Pressure Pans The pressure pan is a duct leakage diagnostic tool which is used along with the Blower Door and digital pressure gauge to identify exterior air leakage in duct systems. The pattern of pressure pan readings allows for quick identification of major exterior leakage sites, and can be used to tell technicians if they have sufficiently air sealed the duct system. Because the pressure pan does not require taping off registers and grills, it is an extremely quick diagnostic procedure. Two size pressure pans are available: 12 1/2 in. x 14 1/2 in. x 4 in. (32 cm x 37 cm x 10 cm) and 22 in. x 22 in. x 2 in. (56 cm x 56 cm x 5 cm). Handle with heavy duty Velcro provides a secure connection to the Pressure Pan. The threaded handle fits most standard painter s pole.

Blower Door Specifications Component Specifications Model 3 Blower Door Fan Maximum Flow: 6,100 CFM at free air (2,879 l/s, 10,364 m 3 /h). 5,250 CFM at 50 Pa (2,478 l/s, 8.920 m 3 /h). 4,900 CFM at 75 Pa (2,313 l/s, 8.325 m 3 /h). Minimum Flow: 300 CFM with Ring B (141 l/s, 510 m 3 /h). 85 CFM with Ring C (40 l/s, 144 m 3 /h). 30 CFM with Rings D (14 l/s, 51 m 3 /h). 11 CFM with Rings E (5 l/s, 18 m 3 /h). Dimensions: 20 in. (50 cm) inlet diameter, 10.25 in (26 cm) length. Weight: 33 lbs. (15 kg) with Flow Rings A & B. Flow Accuracy: +/- 3% with DG-700, Rings D & E +/- 4% or 1 CFM. Calibration: Meets ASTM Standard E779-10, E1554-07, CGSB-149.10-M86, RESNET 2012 EN 13829, CIBSE TM23, ATTMA TS-1 and NFPA 2001. Power 3/4 hp motor available in 110V or 220V. Adjustable Frame and Frame Material: Extruded Aluminum. Frame Material Width: 28 in. to 40 in. (71 cm to 101 cm). Height: 52 in. to 96 in. (132 cm to 244 cm). Seal: EPDM flexible gasket. Panel Material: Nylon w/built-in vinyl window. Specifications subject to change without notice. Minneapolis Blower Door, TECTITE and TECLOG TECLOG2 are trademarks of The Energy Conservatory. Duct Blaster and TrueFlow are registered trademarks of The Energy Conservatory. Standard Minneapolis Blower Door Kit includes: Fan with variable speed controller and fan control cable. Two Flow Rings (A and B) and No Flow Plate. DG-700 Pressure and Flow Gauge TECTITE Building Airtightness Testing Software USB cable - 16 feet (5 meters) long Other building diagnostic products available from The Energy Conservatory Fabric door panel with viewing window. Five piece adjustable aluminum door frame and frame case. Padded attache case to hold gauge, manuals, tubing, speed controller, and fabric panel, with room for a laptop computer and other documents. The Minneapolis Duct Blaster is used to measure the airtightness of duct work. Infrared Cameras by Flir help speed up diagnostic work, especially when used with a Blower Door. The TrueFlow Air Handler Flow Meter, shown with DG-700, is used to measure the total amount of air moving through an air handler. To Order, or for more information contact: The Energy Conservatory 2801 21st Avenue South, Suite 160 Minneapolis, Minnesota 55407 phone: (612) 827-1117 fax: (612) 827-1051 e-mail: info@energyconservatory.com website: www.energyconservatory.com