Water /Electrical Heating Thermostat

Similar documents
MH9-CO2-WA/WD. Introduction. Specification

Touch Panel Dimmer MH-P511. Introduction

Mini Energy Dimmer MH-P210

Micro Dimmer MH-P220. *Note: For non-resistive load, a derating output is highly suggested.

Installation Instructions

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Digital Overhead Stirrer

Quick Start Installation and User Manual

SOLARIMMERSION IV Advanced Installation Manual v1.9

ARIENSE SENSE YOUR WORLD. 3-Axis Force Sensor FSE103. User Guide. Version 2.1. July VARIENSE INC.

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

V ARIENSE SENSE Y O UR W ORLD. Inertial Measurement Unit VMU931. User Guide. Version 1.3. March VARIENSE INC.

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

SP6R Level Controller Operation Manual

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

1411 S. Roselle Rd. Schaumburg, IL Phone (847) Fax (847)

VR 80 Remote Control Device

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT

RТTH DUAL ROOM SWITCH

LevCon. Liquid Level Indicator / Controller DIAL-SJE ( )

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

Wireless Lighting Control ZRM-M80 Z-Wave Smart Plug (with switch and energy meter) USER MANUAL

RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

Installation, Start-up and Operating Instructions

PS8 - II. Professional Power Sequencer. User s Manual

ERT50T Triac Noiseless Digital Room Thermostat for Underfloor Heating Applications

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Digital Timer Outlet Model No.: EDT-1USA. Questions or Concerns? (855)

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

Motion Sensor 2 with temperature sensor

Pulse LED Instruction Guide

Conductive Level Controller

Digital Room Thermostat for Underfloor Heating Applications

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Semi flush-mounted room temperature controllers with LCD

7 Day Digital Programmer 2 Channel Surface Mount

ABB Drives. User s Manual I/O Module Adapter AIMA-01

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

PIXIM Micro Dome Camera

Programmable(5+1+1)Touch Screen LCD Wired Thermostat. General. Features. Operating Algorithm

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

Installation Instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Tempco Instruction Manual

Operating Manual RISH DPM Hz

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

Semi flush-mounted room temperature controllers with LCD

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

Wireless Doorphone Intercom

Carbon Monoxide (CO) Gas Detection and Control System

POP_ Z-Wave Schuko Plug-in Switch plus Power Meter Firmware Version : 1.1

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Wireless 7 Day Programmable Room Thermostat

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 5

EM10 TEMPERATURE / HUMIDITY /DEW POINT METER

ELV12 Series. Instruction Manual

RXTP ROOM TEMPERATURE

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

Temperature Controller

HD-SDI Vandal Dome Camera

Model: Available in : Sapphire Black and Glacier White

Sonic Ruptor 400. User Manual

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

MICRO GROW GREENHOUSE SYSTEMS, INC

Bluetooth Ceiling Fan Control with App Owner's Manual

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Escort LED LIGHTS USER MANUAL

ML-20IP INNOVATION DIRECT. IP video door station. User manual. Thank you for the choice of our equipment. { Design. Uniqueness. Innovations } SERIES

User Manual - KVM Rear Kit Version

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

SHUTTERBOSS VERSION II USER MANUAL

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

7-day room temperature controller

LED FOLDING WORKLIGHT TM

Digital Room Thermostat

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

Self-Adjusting Ultrasonic Wall Switch Sensor

Smart Touch Thermostat Colour Touchscreen Thermostat

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

b. Time Setting c. Volume Setting d. Backlight Setting e. Sleep Setting f. Pin Setting g. Joystick Calibration...

Model: Available in : Sapphire Black and Glacier White

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Installation Instructions

Operation Manual for VXC4000 VXC4000 V

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

PMCG - MANUAL PMCG ORIGINAL INSTRUCTIONS. Preservatech Europe sp z o.o. Równa 1, Bydgoszcz, Poland

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

High Performance Sound Pick-up Microphone Kits

Model: EP210. Dual channel programmable controller. Installation Manual

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Transcription:

Water /Electrical Heating hermostat MH7H-WH / MH7H-EH Introduction MCOHome Water / Electrical Heating hermostat is a Z-Wave enabled device for indoor temperature control. MH7H-WH is mainly applied to control wall mounted boiler, water valve/pump etc., while MH7H-EH is for electrical heating system. he device is of high reliability and practicability, which can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. Features: Capacitive touch buttons empered glass panel, PC alloy enclosure Precise temperature calibration function Attractive appearance Clear display, easy to operate Specification Power Supply:AC85-260V, 50/60HZ Output: MH7H-WH 5A ; MH7H-EH 16A Self Consumption: 1W Internal emp. Sensor: C 15K External emp. Sensor(optional): C R25 =15KΩ B25 /50 =3550K Working Environment:0-50 ; 0-90% RH(on-condensation) emperature Setting:5-37 (41-99 )(Adjustable) Dimension:86* 86*15mm Hole Pitch:60-61mm Safety Information o protect yourself and others from danger and to protect the device from damage, please read the safety information before using it. Important! A qualified electrician with the understanding of wiring diagrams and knowledge of electrical safety should complete installation following the instructions. Before installation, please confirm the real voltage complying with the device s specification. Cut off any power supply to secure the safety of people and device. During installation, protect the device from any physical damage by dropping or bumping. If happens, please contact the supplier for maintenance. Keep the device away from acid-base and other corrosive solids, liquids, gases, to avoid damage. MCOHome echnology Co., td 1

www.mcohome.com Avoid overexertion during operation, to protect device from mechanical damage. Read all instructions and documentation and save for future reference. Installation & Wiring ocation: hermostat is suggested to be installed indoor, a place with around 1.5m height above the floor where represents the average room temperature. It should be away from direct sunlight, any cover, or any heat source, to avoid false signal for temperature control. CAUIO: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock or death! Step 1: Separate the device into two parts: the display panel and the bottom. Step 2: Insert all wires into the right terminals and tighten screws. Wiring diagrams are shown below. Step 3: Push the bottom into the junction box and secure it with two screws, and then mount the touch panel back. Step 4: Confirm the device is well mounted, power on and it is ready to operate. Passive com ormal open ormal close Sensor COM O C Valve Sensor COM O C Elec Sensor OU (1)Passive Wall-boiler (2)Active normal close valve (3)Electrical Heating Model erminals Control devices Wiring instructions For passive control, COM O hermostatic follow wiring diagram MH7H-WH C valve/electric (1); For active control, ball valve/pump follow wiring diagram (2) terminal is to be Heating film connected with an MH7H-EH OU electric radiator, external sensor with heating cable ect high temperature protection function Contact capacity 10A 16A MCOHome echnology Co., td 2

MH7H-WH- W15 COM O C hermostatic valve/electric ball /pump terminal is to be connected with an external ambient temperature sensor 10A MH7H-EH- W15 OU Heating film electric radiator, heating cable ect terminal is to be connected with an external ambient temperature sensor 16A Button & Display Operation On/Off operation When power on, thermostat displays,all outputs are forced off. ouch S3 button to switch (manual/off/auto) mode, then press S2 to confirm and proceed power on/off setting. After power on, device displays current week, local time, working mode, current temperature, output status etc. ote:after the backlit goes out, please press the button to light up the backlit first, then press the button again for corresponding operation. emperature setting In normal working status, press S4 or S5 button will enter into temperature setting interface. he setting range is 5-37 (41-99 ). hen press S4 or S5 can adjust the value. Press S3 or wait 25 seconds without any key operation will save the setting and return back to the normal operation interface. Auto Mode: he changed value only valid in the current time period for this time, and the device will not effect the preset time period value. Manual Mode: he changed value will be valid until next setting. Vacation Mode: he changed value will be valid until next setting. MCOHome echnology Co., td 3

Key lock function In normal operating interface, long press S1+S4 button, icon appear that indicates the button is locked, at this time all buttons are disabled; When long press S1+S4 button again, icon disappear that indicates the button is unlocked, all buttons back to normal work. Control specifications MH7H-WH Detection temperature < setting temperature - 0.5, output turns on, and output icon displays. Detection temperature setting temperature + 0.5, output turns off, and output icon disappears. MH7H-EH Detection temperature < setting temperature - 1.5, output turns on, and output icon displays. Detection temperature setting temperature, output turns off, and output icon disappears. Manual / Auto mode setting In normal display interface, touch S3 button can switch between Manual and Auto mode. Choose the mode you may need and press S2 button to save the setting. Auto Mode: Device will follow the preset time periods and temperature to control heating system automatically. Manual Mode: Device will follow the manual setting temperature to control the heating system. Vacation mode setting In normal working interface, if vocation mode is not activated, long press S2 button to enter vacation mode temperature setting. he default temperature is 10, and setting range is 5-37 (41-98 ). Press S4 or S5 to adjust the value, then press S3 or wait 25 seconds to save the setting and return to the normal working interface. In this time vacation mode icon displays, and device will follow the setting. ong press S2 again will end vacation mode and resume to normal work, vacation mode icon will be disappeared. ocal ime Setting In normal working interface, long press S1 to enter into local time setting interface. In local time setting interface, press S4 or S5 button to set the week, hour & minute parameter, and press S1 button can switch among the week, hour & minute. After finish the local time setting, press S1 or wait 25 seconds without any key operation will save the setting and return to normal display. MCOHome echnology Co., td 4

Auto Mode ime Periods Parameter Setting In normal working interface, short press S1 to enter into time periods setting. Four time periods can be set for each day of the whole week. Press S2 can switch among Hours, Minutes, emperature value. Press S4 or S5 can change the value. After finished the setting of 4 time periods on Monday, press S1 and follow the same way to set periods of next days. After all periods set, press S1 /S2 or wait 25 seconds without any key operation will save the setting and return to normal display. Device will operate in accordance with the new setting. he default setting is as follow: Week\Periods Period 1 Period 2 Period 3 Period 4 Mon~Fri 5:00 18 7:00 16 16:00 22 21:00 16 Sat~Sun 6:00 18 8:00 16 16:00 22 21:00 16 High temperature protection (For MH7H-EH Electrical Heating OY) When external temperature sensor detect the temperature value 55, device will open high temperature protection, electric heating will be forced off, and high temperature protection icon displays. When external temperature sensor detect the temperature value<50, device will return to normal work, high temperature protection icon disappears. Anti-freeze protection function: (Optional) In shutdown interface: When the built-in temperature sensor detect the temperature value 5, device will open anti-freeze protection, electric heating will be forced open, and anti-freeze protection icon displays. When the built-in temperature sensor detect the temperature value>8, device will turn off anti-freeze protection and return to normal work, anti-freeze icon disappears. ote: If MH7 thermostat do not connect with an external temperature sensor, it will only display the indoor temperature icon; If MH7 thermostat connect with an external temperature sensor, it will display the indoor temperature and high temperature protection icon; When it is under high temperature protection, high temperature protection icon flickers. Humidity display operation In normal working interface, long press S1+S5 buttons and enter into humidity display interface, when press S1+S5 buttons again, it will back to the normal interface. Z-Wave Operation Including & Excluding of Z-Wave network In normal working interface, press & hold S4 to enter interface for inclusion or exclusion of Z-Wave network. Before device included into network, - - - will display on the screen. hen press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID will display on the screen in a few seconds. MCOHome echnology Co., td 5

A node ID can always inform us whether the device is in the network or not. ote: Follow the same steps to exclude the device from the network. After inclusion, turn off the device and then turn it on. ow the device is ready to be operated by controller/ gateway in Z-Wave network. Association Group hermostat supports 1 association group. A gateway is suggested to associate with this group. hen if any changes happen, such as: temperature, working mode, etc., the thermostat will report to this associated device (gateway). Command Class supported by the device: COMMAD_CASS_BASIC; COMMAD_CASS_SESOR_MUIEVE; COMMAD_CASS_HERMOSA_SEPOI; COMMAD_CASS_HERMOSA_MODE; COMMAD_CASS_HERMOSA_OPERAIG_SAE; COMMAD_CASS_IME, COMMAD_CASS_ASSOCIAIO; COMMAD_CASS_VERSIO; COMMAD_CASS_MAUFACURER_SPECIFI COMMAD_CASS_IME_PARAMEERS ote: his device supports 4 kinds of modes in Z-Wave: Off mode; Heating mode (Manual); Energy Saving heating mode (Auto) ; Away heating mode (Vacation). Users can set these 4 modes via COMMAD_CASS_HERMOSA_MODE. And COMMAD_CASS_BASIC can switch among Heating mode & Energy saving heating mode. COMMAD_CASS_HERMOSA_SEPOI can be used to set the heating temperature threshold value in Heating mode or Energy saving heating mode. Parameters Settings: Add Function Byte Options Default Remark Upload temperature 0x00Celsius 0x01Fahrenheit 1 1 format automatically 0x02Follow the main display 0x02 0x00 0x01 Upload the difference 2 Upload temperature and humidity automatically 1 value only 0x02 iming upload mode only 0x03 Upload the 0x03 difference+timing upload mode 3 Upload temperature difference 2 Base on 0.1 unit, 0x0005 by default, 5*0.1 =0.5, 0x0003~0x03E8 0x0005 0.5 4 Upload time interval regularly 2 Base on 1s unit, it suggest to be set above 30s 0x000A~0xFFFF 0x001 E 30S MCOHome echnology Co., td 6

5 Upload humidity difference 1 FF Factory setting 1 When the detection humidity value differ with the last percentage value, uploading activated 0x02~0xFF 0x55 Restore the factory setting(write only) 0x03 3% Parameters setting back to default value, association groups deleted 1-year imited Warranty MCOHome warrants this product to be free from defects in material and workmanship under normal and proper use for one year from purchase date of the original purchaser. MCOHome will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. HIS IMIED WARRAY DOES O COVER AY DAMAGE O HIS PRODUC HA RESUS FROM IMPROPER ISAAIO, ACCIDE, ABUSE, MISUSE, AURA DISASER, ISUFFICIE OR EXCESSIVE EECRICA SUPPY, ABORMA MECHAICA OR EVIROMEA CODIIOS, OR AY UAUHORIZED DISASSEMBY, REPAIR OR MODIFICAIO. his limited warranty shall not apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the product was not used for its intended function. his limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, that has not been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary to Country and other applicable export regulations. Secret Menu In shutdown state, long press S3+S5 synchronically can enter into secret menu. Press S4 or S5 to enter code 1234. ouch S3 to enter setting interface. Following are parameters which can be set. Item Explain Default Range Remark P01 emp. Setting upper limit 37.0 (99 ) 00-99.5 (32-211 ) Always confirm the upper limit > bottom P02 emp. Setting bottom limit 5 (41 ) 00-99.5 (32-211 ) limit P03 Slave Address 1 96 1~64 12~576 Reserved P04 Hourly 24 12/24 P05 P06 EH back by emp. differential WH back by emp. differential EH emp differential WH emp differential 1.5 (3 ) 0.0-10.0 (0-18 ) 0.5 (1 ) 0.0-10.0 (0-18 ) 0.0 (00 ) 0.0-10.0 (0-18 ) 0.5 (1 ) 0.0-10.0 (0-18 ) MCOHome echnology Co., td 7

P07 Anti-freeze temperature setting 5 (41 ) 0-30 (32-86 ) P08 Protection temperature 55 (131 ) 45-95 (113-203 ) Indoor temperature control High temperature control P09 Power on state /OP/PRU = electricity power off,= OP electricity power on,= PRU power failure memory P10 P11 he time of temperature change emperature calibration 2 0-99 0.0 (00 ) -9.5-9.5 (-16-16 ) P12 Sound level 3 OF/0-9 P13 Backlit level 2 1-8/O/ P14 External temperature 0.0 (00 ) -9.5-9.5 (-16-16 ) P15 External temperature control switching O O/ O/ Indoor temperature control External sensor temperature control P16 External temperature display switching O O/ O/ Indoor temperature display External temperature display =OC,Celsius; P17 emp. format OC OC/OF =OF,Fahrenheit(After modify settings, to restore the factory settings.) P18 Restore factory setting * After power failure: Display: 53 Password: 55 00-99 0 indicates device will be in shutdown state ( ) when power on again; Change 53 to 55, and press S3 to confirm 1 indicates device will be in working interface when power on again; 2 (default) indicates device will stay the status before power failure when power on again. MCOHome echnology Co., td 8