ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Similar documents
ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

115/230 VAC Digital Input Module OHDI-01

User s Manual Pulse Encoder Interface Module OTAC-01

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

ABB Drives. User s Manual I/O Module Adapter AIMA-01

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

Options for ABB drives, converters and inverters. User s manual FEA-03 F-series extension adapter

Start-up Guide. AF 100 Adapter Kit NAFA-01

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

Options for ABB drives. User s manual FSE-31 pulse encoder interface module

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

RER 123 Bus Connection Module. Technical Description

Installation Instructions

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor Start-up Guide DeviceNet Adapter Module NDNA-02

ICF-1150 Series Quick Installation Guide

Installation Instructions

Installation Instructions

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

Installation Instructions

Installation Instructions

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

5 Fieldbus Technology

Dimensional drawings. Dimensional drawings

Installation Instructions

ICF-1150 Series Quick Installation Guide

- Alii -,..., ~~~~~~~~'-~" ..., ,..- ))) --t ..., )(1. User s manual FEPL-02 Ethernet POWERLINK adapter module. IIIIIJ!ll"

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

270 MHz Control Modules

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

R507 I.S. Interface Module User Manual

Installation Instructions

ABB industrial drives. EMC filter and ground-to-phase varistor disconnecting instructions ACS880 frames R1 to R11

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

25 South Street, Hopkinton, MA

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual

EX-RC1 Remote I/O Adapter

Digital ac/dc (24V) Input Module

Installation Instructions

Serial PROFIBUS Interface

Manual Fiber Optic Interfaces

EX-RC1 Remote I/O Adapter

TCF-142-RM Series Hardware Installation Guide

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

205 CPU NETWORK ADAPTER F2-UNICON

TCF-142 Quick Installation Guide

CS485. User s Manual. Version ZYPEX, Inc.

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

General Specifications. P2-SCM Serial Communications

P3-SCM. General Specifications

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

RS485 MODBUS Module 6RO

RS485 MODBUS Module 8AO

Manual Industry Interfaces

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

Installation Guide VLT EtherNet/IP MCA 121

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

EX-RC1 Remote I/O Adapter

Installation Guide VLT PROFIBUS DP MCA 101

PTC/PT100 board 2.0 Option

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Model 7705 Control Module

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

crio PN Installation Instructions V0.2/ COMSOFT

PROFIBUS-DP/MODBUS RTU REPEATER

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Allen-Bradley Drives

GT- IRDM-9603 Product description Rev. 2 17/06/2014

IMPORTANT SAFETY INSTRUCTIONS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

SFP 10/100/1000Mbit Copper RJ45 Transceiver

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Installation Instructions

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

Unitronics Devices and RS485 Table Of Contents

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives

RS 485 Mini Modbus 1AO

RTU560 Remote Terminal Unit Connections and Settings

Model 3750 Multifunction I/O Card

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

Installation Guide Controller Series E130/E230/E430

ABB industrial drives. Supplement ACS880 distributed I/O bus

Installation Instructions

MOVIDRIVE Drive Inverters

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Transcription:

ABB Drives User s Manual Modbus Adapter Module FMBA-01

Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved.

5 Safety instructions Overview This chapter states the general safety instructions that must be followed when installing and operating the FMBA-01 Modbus Adapter module. The material in this chapter must be studied before attempting any work on, or with, the unit. In addition to the safety instructions given below, read the complete safety instructions of the specific drive you are working on. General safety instructions WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians. The drive and adjoining equipment must be properly earthed. Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied, regardless of motor operation. There can be dangerous voltages inside the drive from external control circuits even when the drive mains power is shut off. Exercise appropriate care when working on the unit. Neglecting these instructions can cause physical injury or death. Safety instructions

6 Safety instructions

7 Table of contents Safety instructions............................................ 5 Overview.................................................... 5 General safety instructions....................................... 5 Table of contents............................................. 7 Introduction................................................. 9 Intended audience............................................. 9 Before you start............................................... 9 What this manual contains....................................... 9 Terms used in this manual...................................... 10 Overview................................................... 11 Overview................................................... 11 RS-485 standard............................................. 11 The FMBA-01 Modbus Adapter module............................ 12 Compatibility............................................... 13 Delivery check............................................. 13 Mechanical installation....................................... 15 Mounting................................................... 15 Electrical installation......................................... 17 Overview................................................... 17 General cabling instructions..................................... 17 RS-485 connection............................................ 17 Bus termination.............................................. 18 Table of contents

8 Technical data and diagnostics................................. 19 FMBA-01 Modbus Adapter module................................ 19 RS-485 link.................................................. 20 LED indications............................................... 20 Table of contents

9 Introduction Intended audience Before you start The manual is intended for the people who are responsible for commissioning and using an FMBA-01 Modbus Adapter module. The reader is expected to have a basic knowledge of electrical fundamentals, electrical wiring practices and how to operate the drive. It is assumed that the drive is installed and ready to operate before starting the installation of the extension module. In addition to conventional installation tools, have the drive manuals available during the installation as they contain important information not included in this manual. The drive manuals are referred to at various points of this document. What this manual contains This manual contains information on the wiring, configuration and use of the FMBA-01 Modbus Adapter module. Safety instructions are featured on the first few pages of this manual. Overview contains a short description of the RS-485 standard and the FMBA-01 Modbus Adapter module and a delivery checklist. Mechanical installation contains placing and mounting instructions for the module. Electrical installation contains wiring, bus termination and earthing instructions. Introduction

10 Technical data and diagnostics contains information on physical dimensions and connectors of the module and the specification of the RS-485 link. It also explains how to trace faults with the status LEDs on the FMBA-01 Modbus Adapter module. Terms used in this manual Communication Module Communication Module is a name for a device (e.g. a fieldbus adapter) through which the drive is connected to an external communication network (e.g. a fieldbus). The communication with the module is activated with a drive parameter. FMBA-01 Modbus Adapter module The FMBA-01 Modbus Adapter module is one of the optional fieldbus adapter modules available for ABB drives. The FMBA-01 is a device through which an ABB drive is connected to a RS-485 network. Introduction

11 Overview Overview This chapter contains a short description of the RS-485 standard and the FMBA-01 Modbus Adapter module, and a delivery checklist. RS-485 standard RS-485 is a serial interface standard for communication over a twisted-pair cable. Because the RS-485 signal transmission is differential, it provides better protection against noise and longer transmission distances than the RS-232. RS-485 is a half-duplex multi-drop network, which means that multiple devices may reside on line. Only one transmitter may be active at any given time. The RS-485 standard specifies only the electrical characteristics of the bus system. The communication protocol and communication speed depend on the used application. For example the electrical characteristics of the PROFIBUS and MODBUS are based on the RS-485 standard. The RS-485 transmission line consists of two wires, A and B. The signal transmission is based on the voltage difference between the wires. Minimum detected voltage difference is 200 mv. The potential difference between the two wires determines the logic state bit: when B is at higher voltage than A, the state is defined as bit 1 (data high) and when A is at higher voltage than B, the state is defined as bit 0 (data low). The common mode voltage between RS-485 network devices is limited to -5...+12 V. Ground wire and cable shield should be connected to prevent common mode voltage between the network devices from drifting outside the allowable limits. Overview

12 RS-485 bus cable should be terminated with a 120 ohm resistor on both ends to prevent signal reflection. When no device on the network is transmitting, noise can be falsely interpreted as communication data. To avoid this, termination can be included with a fail-safe circuit (pull-up and pull-down resistors). The circuit forces the bus into a known idle state when no device is transmitting. The FMBA-01 Modbus Adapter module The FMBA-01 Modbus Adapter module is an optional device for ABB drives which enables the connection of the drive to a RS-485 network. The FMBA-01 provides galvanic isolation between the drive and RS-485 network and converts serial communication signals of the drive to RS-485 signal levels. The FMBA-01 has a built-in bus termination with fail-safe circuitry. The termination can be activated with a jumper. The adapter module is mounted into an option slot on the motor control board of the drive. See the drive documentation for module placement options. Construction of the RS-485 network and the FMBA-01 Other RS-485 device ABB drive Other RS-485 device Diagnostic LEDs (See chapter LED indications) Termination jumper J1 (See chapter Electrical installation) Bus connector X1 (see chapter Electrical installation) Overview

13 Compatibility The FMBA-01 Modbus Adapter module is compatible with all stations that comply with RS-485. Delivery check The option package for the FMBA-01 Modbus Adapter module contains: Modbus Adapter module, type FMBA-01 this manual. Overview

14 Overview

15 Mechanical installation WARNING! Follow the safety instructions given in this manual and the drive documentation. Mounting The FMBA-01 Modbus Adapter module is to be inserted into its specific position in the drive. The module is held in place with plastic pins and one screw. The screw also provides the earthing of the fieldbus cable shield connected to the module. On installation of the module, the signal and power connection to the drive is automatically made through a 20-pin connector. (All drives do not use all the available signals so the connector on the drive may have fewer pins.) Mounting procedure: Insert the module carefully into its position on the drive. Fasten the screw. Note: Correct installation of the screw is essential for fulfilling the EMC requirements and for proper operation of the module. Mechanical installation

16 Mechanical installation

17 Electrical installation Overview This chapter contains: general cabling instructions instructions for setting the bus termination instructions for connecting the module to the RS-485 network. WARNING! Before installation, switch off the drive power supply. Wait five minutes to ensure that the capacitor bank of the drive is discharged. Switch off all dangerous voltages connected from external control circuits to the inputs and outputs of the drive. General cabling instructions RS-485 connection Arrange the bus cables as far away from the motor cables as possible. Avoid parallel runs. Use bushings at cable entries. RS-485 cable is connected to connector X1 on the FMBA-01 Modbus Adapter module. X1 1 2 3 4 Description 1 SHLD Bus cable shield. Connected internally to GND_B via an RC filter and directly to CH_GND (chassis). 2 DATA_B Data positive 3 DATA_A Data negative 4 GND_B Isolated signal ground Electrical installation

18 Bus termination Bus termination is required to prevent signal reflections from the bus cable ends. The FMBA-01 Modbus Adapter module is equipped with internal bus termination, which is configurable with jumper J1 pins. Termination should be activated on devices located at bus ends and deactivated on other devices. See the figure below. RS-485 bus termination J1 J1 J1 J1 Termination activated Termination deactivated Termination deactivated Termination activated RS-485 device RS-485 device RS-485 device RS-485 device Term. Term. Term. Term. ON OFF OFF ON Electrical installation

19 Technical data and diagnostics FMBA-01 Modbus Adapter module Enclosure: 63 3.3 20.5 13 74.4 65 5 21.3 Mounting: Into the option slot on the drive Degree of protection: IP20 Ambient conditions: The applicable ambient conditions specified for the drive in its manuals are in effect. Indicators: Three LEDs (HOST, RXD, TXD) Connectors: 20-pin connector to drive (X2) 4-pin detachable screw connector to bus (X1) 6-pin jumper block for bus termination configuration (J1) Power supply: +3.3 V ±5% max. 150 ma (supplied by the drive) Technical data and diagnostics

20 General: Estimated min. lifetime: 100 000 h All materials UL/CSA-approved Complies with EMC standards EN 50081-2 and EN 50082-2 Bus interface functionally isolated from drive RS-485 link Compatible devices: All RS-485 compliant devices LED indications Medium: Shielded twisted pair cable, impedance 100 to 150 ohm Termination: 120 ohms (built in the FMBA-01 Modbus Adapter module) Topology: Trunk line, drop lines allowed Transfer rate: 5 Mb/s max. Serial communication type: Asynchronous, half-duplex RS-485 Protocol: Depends on the used application. Typically Modbus. The FMBA-01 Modbus Adapter module is equipped with three green diagnostic LEDs. The LEDs are described below. Name Colour Function HOST Green The module is powered up. RXD Blinking The module receives data from the bus. The LED blinks whether the received data is address to the unit or not. TXD Blinking The module sends data to the bus. Technical data and diagnostics

3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 ABB Oy AC Drives P.O. Box 184 FI-00381 HELSINKI FINLAND Telephone +358 10 22 11 Fax +358 10 22 22681 Internet http://www.abb.com ABB Inc. Automation Technologies Drives & Motors 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone 262 785-3200 800-HELP-365 Fax 262 780-5135