LED-Illumination with Control Unit Ident.-No

Similar documents
RТTH DUAL ROOM SWITCH

icore Kiosk system Installation Guide

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

HCC-CW-201A. CWDM Analyzer. Operation Guide

Emergency power supply NV2.1-12iaE

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

38 MHz Passive Voltage Probe R&S RT-ZP1X

SCHOTT EasyLED Series

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Greenline-Laser 3P / 5P

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

SolConeX extra-low voltage flange socket

Operating instructions. Switching amplifier DN0210 DN / / 2015

CPA 40 Two Channel Amplifier

Crossfire. User Manual. Order code: EQLED061

BEETLE /Fusion Compact. Installation Guide

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Table of Contents List of Equipment General Information Safety Precautions Device Installation...

FastGene FAS-Nano. Catalogue Number GP06-LED

Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

ECOLINE EL 515 PLUS EL 515 PLUS SET

PI-EX-ME-2NAM/COC-24VDC

ENGLISH Flexstrip Set RGB

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

PMT 221A High Impedance Passive Probe. Instruction Manual

ENGLISH Flexstrip Set IP44 RGB

Technical Manual Room temperature controller

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Operating Instructions

Digital Overhead Stirrer

Lynx Pro Audio S.L. Valencia, Spain

xbrick Full-Colour 16 3W LED floodlight user manual

RXTH DUAL ROOM SENSOR / SWITCH

PML 791-RO Low-Z Passive Probe. Instruction Manual

Product manual plug, sockets and coupler 16 A.- Z0251

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

Operation and Installation Manual

TVAC25100 TVAC25110 User manual

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

OPERATING INSTRUCTIONS

F-712.PM1 Optical Power Meter

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Version-E Manual PR1a. Photocell. Manual. Page 1

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

Operating instructions. Speed monitor D / / 2014

RXTP ROOM TEMPERATURE

Technical Manual Movement detector/switch actuator, 1-gang

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

HX1 Bluetooth Stereo Headset

PM-204A/B. Power Meter. Operation Guide

RGB Power Batten. User Manual. Order code: EQLED032

Flexoled FTP3HP RGB LED DMX Driver

User Manual. pe-100 fiber. DOC-014 Iss 3 1

Power Supply (48Vdc, 2.5A)

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Operating Instructions

Installation Instruction. HART Add-On Module

HST -S1 Switching element (Translation of Original Manual)

Description. Kingbright

VR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

FTP1 Single Channel LED DMX Driver

Diffuse reflection light scanner with background suppression. Dimensioned drawing

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Technical Manual Sensor / Switch actuator 1/1gang; 2/1gang; 2/2gang

LED Profile 150W 3200K. User manual. LED spotlight

Sliding shutter control Aluminium shutters

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

DRAGON-X. Technical Operating Data DATA SHEET

-bio. Densitometer DEN-1B Operating instructions

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

LED Accu Penta 9x12W RGBWAU

Lighthouse LEDs. Customer Approval. Product Name High Bright Blue LED. Part Number. Customer. Customer PN. Version.

EQUIPMENT Operation Manual

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101

ShadowLESS lighting systems for microscopy

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Manual Movement detector/switch actuator, 1-gang

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

X-Beam Waterproof Action Camera Light USER GUIDE

ITB THROTTLE WITH INTEGRATED STEPPER MOTOR INSTALLATION INSTRUCTION

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

COMPACT eco -DIN Document Rev1

D Issue A. Instruction Manual. Active Strain Gauge

FT-20 Fire Training Fog Machine User Manual English

7032 Digital-Analog Multimeter

Transcription:

A HAAG-STREIT COMPANY MÖLLER-WEDEL OPTICAL GmbH, Rosengarten 10, D-22880 Wedel with Control Unit Ident.-No. 773 190 01 Valid from Hardware / Software Rev. / SN 1.0 IDENT.-NO. 217 321 09 Document Version 08.03.2013

Content 1. IMPORTANT INFORMATION... 3 Liability to Functions and Damage... 4 2. INTENDED USE... 5 2.2 Description of modules... 5 2.2.1 Control Unit... 5 2.2.2 LED-Head... 6 3. ASSEMBLING / STARTING UP... 7 3.1 Unpacking and inspection of delivery... 7 3.2 Starting up... 7 4. TECHNICAL DATA... 7 CE EG Declaration of conformity WEEE and RoHS declaration of conformity Ident.-Nr.: 217 321 09 2

1. Important information Safety Remarks This equipment must only be used following the instruction manual. Please read the instructions first. It is only allowed to use the equipment in the intended way. The equipment is only for use in clean and dry environment. Also see next paragraph. The valid accident prevention regulations of Employer s for Electrical Systems and Operating Materials are to be observed. Special accident prevention regulations may occur out of the specific use of the instrument and have to be considered. The year of manufacturing and the serial number of the equipment is documented on the identification label. Keep this manual for later use. Safety conditions for operating the Equipment The following conditions are to observe for save operating of the instrument: Only for indoor use. Use only in clean and dry environment. No conductance dirt cover or condensation. Equipment must be adapted to the operating conditions in time to avoid any condensation. Operating Temperature 5-40 C. Humidity less 80% up to 32 C linear decreasing to 50% at 40 C. Height above zero normal not more than 2000 m. Tolerance of mains voltage not above 10% from nominal value. Mains voltage 100-240V~ AC depending on country. Operating the equipment in mains, where transient over voltage peaks exceed the common values (more than allowed according to Over Voltage Class III according to EC664) is forbidden. It is not allowed to cover power supplies, to short-circuit the output or to pull them by cable. Defect or damaged supplies and cables must be disabled and substituted by original MÖLLER-WEDEL OPTICAL spare parts. Power plugs are only allowed to clean with a soft and dry cloth. Before cleaning disconnect them from the main voltage and the equipment. Do not short-circuit batteries or accumulators. Do not burn or open. Only use sealed batteries Additional restrictions in use may result of the measurement application and are listed in the technical data. There you will also find other base data. MAINTENANCE AND CARE Modifications or maintenance must only be carried out by persons explicitly authorised by MÖLLER-WEDEL OPTICAL GmbH. Only original parts of MÖLLER-WEDEL OPTICAL must be used for maintenance. After maintenance or technical modifications the equipment must be re-adjusted according to the technical instructions. In case of technical inquiries the numbers on the relevant parts must be indicated. Before cleaning or maintenance always disconnect from the mains and other equipment Ident.-Nr.: 217 321 09 3

Liability to Functions and Damage If the equipment is modified or repaired by not explicitly authorised persons, in case of improper maintenance (as far as not performed by MÖLLER-WEDEL OPTICAL) or in case of improper handling, any liability of MÖLLER-WEDEL OPTICAL is excluded. Accessories Electrically driven accessories are permitted on the equipment only if its technically safe application is documented by a notified person (relevant certificate must be available). Declaration of Conformity The declarations according to CE, environment and disposal are attached in the end of the manual. Ident.-Nr.: 217 321 09 4

2. Intended Use The is used as light source in Autocollimators and Collimators. Function description 2.1 Description of / Overview The consists of: Control Unit (Fig. 1.1), One or two LED-heads (Fig. 1.2) and Power supply (Fig. 1.3). 3 2 1 Fig. 1: Components of. 2.2 Description of modules 2.2.1 Control Unit At the control unit the power supply and one or two LED heads will be connected. This type of illumination is working besides with supplied power supply also with 4 NiCd- or NiMH-accumulators - type AA - (not included in delivery). The accumulators can be inserted in the battery case at the back of the case of Control Unit (attend to polarity!). Thereby a mains-independent operation is possible. In case of connecting up a power supply in the battery circuit is switched off. Please note that the batteries can not be charged by the control unit. An external charger is needed. Ident.-Nr.: 217 321 09 5

Use only NiCd- or NiMH-accumulators. Conventional batteries can damage the LED Head due to the higher voltage. With the lower two switches (s. Fig. 2.1) the LED Heads can separately be switched on and off. The regulation of the brightness is also carried out separately for both LED heads through the two upper switches(s. fig. 2.2). Rotating the upper switches clockwise increases the LED intensity, rotating the switches counterclockwise reduces the intensity 2 1 Fig. 2: Control Unit 2.2.2 LED-Head The LED-Head consists of a cable and a LED-head with five high performance LEDs. Four versions with the colours green, red, blue and white are available. The dominant wavelength is given in the technical data. Security advice : Due to the high brightness avoid direct eye contact. Do not look into the bright beam. 2.2.3 Power supply The power supply is for supplying the control unit with power Only use the supplied power supply! Using other power supplies can cause damage on the Control Unit and the LEDs. Ident.-Nr.: 217 321 09 6

3. Assembling / Starting up 3.1 Unpacking and inspection of delivery The is available in 8 versions: Description Article No.. - green - incl. control unit and universal power plug 217 321 - red - incl. control unit and universal power plug 217 322 - blue - incl. control unit and universal power plug 217 323 - white - incl. control unit and universal power plug 217 324 2-arms, green - incl control unit and universal power plug 217 325 2-arms, red - incl. control unit and universal power plug 217 326 2 arms, blue - incl. control unit and universal power plug 217 327 2-arms, white - incl. control unit and universal power plug 217 328 Each version contains: one Control Unit one (single arm) or two (two armed) LED-Heads and one power supply. Check the delivery immediately after receipt for completeness and damage 3.2 Starting up Connect the LED Head(s) and the Power Supply with the Control Unit. Connect the power supply with the mains. As described under 2.2.1 accumulators can alternatively be used. Install the LED-Head in the condenser mount of the Collimator or Autocollimator. Turn on the with the switches described (fig. 2.1) and adjust the brightness to the desired value 4. Technical Data Red green blue Dominant wavelength 640 nm 520 nm 470 nm Half-width of the spectral output 20 nm 40 nm 30 nm Power Supply Power Supply 100V-240VAC/5VDC optional:4 NiMH- or NiCd-accumulators Ident.-Nr.: 217 321 09 7

Ident.-Nr.: 217 321 09 8

Ident.-Nr.: 217 321 09 9