Changing the 16-Pin Bayonet Cartridge

Similar documents
Changing the 16-Pin Bayonet Cartridge

FRESHMARX 9417 QUICK REFERENCE

Field Equipment for Measuring Electrical Conductivity, Humidity and ph of Soil

Instructions for SVC-KIT-0020

1 Press the cover release button and then open the front cover of the printer. 2 Take out the drum unit assembly (drum unit with toner cartridge).

MONARCH 9416 XL QUICK REFERENCE

Agilent InfinityLab Companion

Datacard CR500 Instant Issuance System. User Reference Guide. July Rev B

QUICK REFERENCE. Getting Started

CLEANING THE DRUM UNIT

At 5% print coverage (A4 or Letter size). The actual number of printed pages will vary depending on the average type of print job and paper.

GTA PREVENTIVE MAINTENANCE CHECKS AND SERVICES ON THE ZOOM STEREOSCOPE 95R

SONNET. CI and EAS Audio Processors. Quick Guide

imac Intel 27" EMC 2429 Hard Drive

1. Review the printer safety information in the Regulatory Compliance document provided with your printer.

Ricoh 2000L Type 1135/1435 Toner Cartridges DOC-0297

Caution PROTECT YOUR FACTORY WARRANTY!

SONNET. CI and EAS Audio Processors. Quick Guide

User Manual. Trinocular Stereo Microscope

Service & Maintenance

FT-20 Fire Training Fog Machine User Manual English

TD-700 FLUOROMETER SERVICE MANUAL

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

2. REFERENCE DOCUMENTS 90R0047 Safety Guidelines for Handling Equipment 90F0112 Safe Handling and Cleaning Procedures for Serviceable ZOLL Product

HP DesignJet 3500CP/3000CP Printer. Quick Reference Guide

When you are ready to build your computer you will have the following materials to work with.

Chapter 2: Disassembly

Replacing the Hardware Configuration Option EPROM on the 1822

TT230SM THERMAL TRANSFER PRINTER USER S MANUAL

HP OfficeJet Enterprise Color MFP X585

Apple 3.5 Drive External Floppy Drive

Fuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW

SONNET CI Audio Processor

S200 Series Brushless Servo Drive EPROM Upgrade

HP 2300 LASERJET PRINTER

FT-20 Fire Training Fog Machine User Manual English

Agilent 2100 Bioanalyzer 2100 Expert User s Guide

S-100X / S-200X Snow Machine User Manual

Agilent 2100 Bioanalyzer. User s Guide for Molecular Assays

apple Service Source Apple Cinema Display 22" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

SONNET. CI and EAS Audio Processors. Quick Guide

imac Intel 27" EMC 2390 Optical Drive

Removal and Installation8

Optional Lens User s Manual

Polarization Microscope. Omano OM349P Series. User Guide

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

SONNET. CI and EAS Audio Processors. Quick Guide

HP CP6015/CM6030/CM6040MFP Remove and Shake Black or Color Cartridges" or " , " Error Messages

Installing imac Intel 27" EMC 2390 Dual HDD or

Bluelab ph Meter TM Instruction Manual

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Chapter 4 Replacement Procedures

learn about the printer... 1

Replace the edrive TINI Module and Battery

Esfera SPM Instruction manual

QUICK REFERENCE. RFID Overview

Instrument User Manual Update RAM209AEN

Instruction Manual Temp JKT Temperature Meter Series

Hewlett-Packard Product Number C6119A Maintenance Manual

imac Intel 27" EMC 2390 Optical Drive Fan

Magnetic Immunoassay Reader Operator Manual

RONDO. Single-Unit Audio Processor. Quick Guide

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

imac Intel 27" EMC 2309 and 2374 Bluetooth

imac Intel 27" EMC 2390 LED Driver Board Replacement

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Replacement Instructions. Backplane PCA for the HP Router 650

Product Recycling Passport Page 1 of 11

VTPC190V / VS / VDC / VSDC

HP 1300 Remanufacturing Instructions Oasis Imaging Products, Inc. Technical Support: ext 110

MVPplus Quick Reference Guide

Chapter 4 Replacement Procedures

Model 8101-PIV Test Fixture User s Guide. Overview. SMU Device holder (near latch) Two Leaded Part Plungers. PIV Device holder (near hinge)

Replacement of analog modules of the IM6/IM6e

Owner s Manual. The Forward Compatible Video Housing for Sony Camcorders.

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

K Service Source. StyleWriter

New Ricoh 1060 Copier. August 2004

Before you can use the machine, you must set up the hardware. Please read this Quick Setup Guide for the correct setup procedure.

RONDO Single-Unit Audio Processor. Quick Guide

CANADIAN D.O.C. WARNING

then remove the printed switched off (the switch is located on 25 Manual duplex (special) heavy-media, card stock. 1 Load composting instructions

FiberExpress Brilliance Connectors

Microsoft Surface Camera Replacement

RONDO 2 Single-Unit Audio Processor

Agilent 2100 Bioanalyzer System & Applications Site Preparation Checklist

K Service Source. Color StyleWriter 2200

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, TX Phone (210) Fax (210) INSTRUCTIONS FOR

The goal of the article to analyze and evaluate this modest personal printer. First

imagine. print. create. Edible Printing Insights SET UP AND TROUBLE SHOOTING GUIDE

Fiber optics solution manual. You can print on a variety of release the Go button on the printer sides of the printer door and pulling.

9 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module. InfinityLab LC Series Diode Array Detectors User Manual

ExpressCard Instant Issuance Card Personalization System Image Printer Lid Cover Replacement. September 30, 2016

870 KF Titrino plus. Installation and tutorial EN

Alienware Area-51 R5 Service Manual

Agilent 1290 Infinity II Evaporating Light Scattering Detector (ELSD) in Empower Environment

Nexa PX700IIS Thermal Receipt Printer. User Manual. P a g e 1

Transcription:

Changing the 16-Pin Bayonet Cartridge Introduction The 16-pin bayonet cartridge (reorder number 5065-4413), see Figure 1, contains 16 electrodes. These are configured to fit in to the wells of an analysis chip. The electrodes make contact with the liquid in the wells when the lid of the Agilent 2100 Bioanalyzer instrument is closed. The cartridge, which includes the pin set, can be removed if the electrodes become contaminated or damaged. Pin Set Figure 1 16-Pin Cartridge and Pin Set of Cartridge Agilent Technologies

Removing the 16-Pin Cartridge Removing the 16-Pin Cartridge CAUTION Touching the electrodes Possible damage to the electrodes and high voltage power supplies Do not touch the electrodes while the cartridge is in the 2100 Bioanalyzer instrument. The line switch is located at the rear of the 2100 Bioanalyzer instrument. 1 Turn off line power to the 2100 Bioanalyzer instrument. 2 Open the lid. 3 Pull the metal lever on the inside left of the lid to the vertical position as shown in Figure 2. When the lever is in the vertical position, the cartridge is released from the lid by about 10 mm. 4 Gently pull the cartridge out of the lid as shown Figure 2. Cartridge released Metal lever Figure 2 Removing the 16-Pin Cartridge 2

Removing the Pin Set of the 16-Pin Cartridge Removing the Pin Set of the 16-Pin Cartridge 1 Remove the 16-pin cartridge as described above. 2 Open the bayonet socket of the pin set by turning the plastic lever to the left as described in Figure 3. Plastic lever Figure 3 Opening the Bayonet Socket of the Pin Set 3

Removing the Pin Set of the 16-Pin Cartridge 3 Remove the cover of the bayonet socket by gently pulling the plastic lever as shown in Figure 4. The pin set may stick to the electrode base. Remove it by carefully pulling it off. See Figure 4. Electrode base Pin set Gently pull cover of bayonet socket Figure 4 Releasing the Pin Set NOTE For hints on how to clean the pin set, refer to Cleaning the Pin Set of the 16-pin Cartridge on page 8. 4

Inserting the Pin Set of the 16-Pin Cartridge Inserting the Pin Set of the 16-Pin Cartridge CAUTION Liquids (even small amounts) on the pin set Possible damage to the high voltage power supply Make sure that the pin set is completely dry before placing it back into the electrode base. 1 Put the pin set on the cartridge base and the bayonet cover on the pin set (see Figure 5). Electrode base Pin set Bayonet cover Figure 5 Inserting the Pin Set 5

Inserting the Pin Set of the 16-Pin Cartridge 2 Lock the pin set to the electrode base by pushing the plastic lever of the bayonet cover to the right as shown in Figure 6. Plastic lever Figure 6 Closing the Socket of the Pin Set 6

Inserting the 16-Pin Cartridge Inserting the 16-Pin Cartridge CAUTION Liquids (even small amounts) on the pin set Possible damage to the high voltage power supply Make sure the pin set is be completely dry before putting in the 16-pin cartridge. 1 Slide the 16-pin cartridge into the 2100 Bioanalyzer lid as shown in Figure 7. 2 Move the metal lever in the flat (closed) position. 3 Push the metal front of the 16-pin cartridge to ensure a tight connection to the 2100 Bioanalyzer. Push here to ensure that a tight connection is made Metal lever Figure 7 Inserting the 16-Pin Cartridge 7

Cleaning the Pin Set of the 16-pin Cartridge Cleaning the Pin Set of the 16-pin Cartridge After removing the pin set from the 16-pin cartridge you can clean it by using de-ionized water, or isopropanol, or RNAse Zap. Pin set Figure 8 Pin Set On a regular quarterly basis, or after contamination, gently clean the pin set with a lint-free surgical cotton swab damped in de-ionized water. In case of highly contaminated or dirty pins you may autoclave the pin set. NOTE NOTE The pins of the pin set should not be bent or misaligned. Both will lead to poor quality results or pre-terminated assay runs. For autoclaving the pin set, follow your standard procedures for plastic material. CAUTION 1 Sonicate the pin set for 10 min. 2 Gently clean the pin set with a soft tooth brush. Liquids (even small amounts) on the pin set Possible damage to the high voltage power supply Make sure the pin set is be completely dry before putting in the 16-pin cartridge. 3 Insert the 16-pin cartridge, see Inserting the 16-Pin Cartridge on page 7. *G2938-90105* *G2938-90105* G2938-90105 Rev. B Edition: 02/2017 For Research Use Only Not for use in diagnostic procedures Printed in Germany Agilent Technologies, Inc 2001-2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn Germany