Planning Manual Hand-held remote control Article No.: 000004 0444 / 0 Contents Device descripition........................... Technical data............................... Accessories................................. Accessories supplied........................... Accessories (plus surcharge)..................... Connection diagram (Ergoline Sunrise, Beauty Angel CVT 4)........................ 7 Connection diagram (Ergoline Essence, Ergoline Balance 440, Beauty Angel CVT 3, Beauty Angel CT 8).......................... 8 Overview to connection options................ 3 Connection diagram (Ergoline Affinity-S / Affinity, Ergoline Balance 00, Ergoline Inspiration-S / Inspiration, Sunangel S 4, Beauty Angel C 4 sun, Beauty Angel C 34 plus ) Series from 0/007.......................... 4 Connection diagram (Ergoline Prestige 400, Ergoline Prestige 00, Ergoline Prestige 000, Ergoline Prestige-S / Prestige, Ergoline Esprit-S / Esprit, Ergoline Open Sun Pilot, Sunangel Duo 400, Sunangel Duo S / Sunangel S, Sunangel Duo 00 Beauty Angel CHP plus,) Series from 0/007.......................... Connection diagram (Ergoline Passion-S, Ergoline Flair, Beauty Angel C 8).............. Hand-held remote control
Hand-held remote control Planning Manual C Device descripition. Display. Operating keys 3. Chip card slot Dual safety cutout switch to standards EN 033--7 and A 000 sections.08 and.09 3 0478 / 0 Technical data Equipment: Relay control for connection to a professional device, with chip card reader Operating voltage: Supply from the respective device with a 7-pole plug / direct connection Max. ambient temperature: 0 to 40 C Max. relative air moisture content: 70 % Max. storage temperature: 0 to 0 C Dimensions [mm]: width x height x depth 00 x 80 x 3 Accessories Accessories supplied Accessories Article / Part No. Notes Master Card ( piece) Control line ( m) Connector plug (extra-low voltage) Accessories (plus surcharge) Accessories Article / Part No. Notes Adapter (Transformer 4 V to 30 V) 343400 e.g. for third-party units Adapter (Transformer 4 V to 30 V) 000083 only in the Ergoline Sunrise series and Beauty Angel CVT 4 Control line (0 m) 7000740 Extension (Handheld remote control to transformer) Hand-held remote control
Planning Manual Hand-held remote control Overview to connection options with Adapter (343400 or 000083) Ergoline Prestige 400 / 00 / 000 from 0/03: see page Ergoline Prestige-S / Prestige from 0/007: see page Ergoline Esprit-S / Esprit from 0/007: see page Ergoline Affinity-S / Affinity from 0/007: see page 4 Ergoline Balance 00 see page 4 Ergoline Inspiration 00 / Inspiration 00 from 0/03: see page Ergoline Inspiration-S / Inspiration see page 4 Ergoline Passion-S see page Ergoline Flair see page Ergoline Sunrise see page 7 (000083) Ergoline Essence see page 8 Ergoline Balance 440 see page 8 Ergoline Open Sun Pilot see page Sunangel Duo 400 / Sunangel Duo 00 from 0/03: see page Sunangel Duo S / Sunangel S see page Sunangel S 4 from 0/007: see page 4 Beauty Angel C 4 sun / Beauty Angel C 34 plus see page 4 Beauty Angel C 8 see page Beauty Angel CVT 4 see page 7 (000083) Beauty Angel CVT 3 / Beauty Angel CT 8 see page 8 Beauty Angel CHP plus see page Hand-held remote control 3
Hand-held remote control Planning Manual Connection diagram (old X3 clamp) Series from 0/007 Ergoline Affinity-S / Affinity Ergoline Balance 00 Ergoline Inspiration-S / Inspiration Sunangel S 4 Beauty Angel C 4 sun Beauty Angel C 34 plus The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge Old X3 clamp: grey yellow 3 white 4 brown green green-yellow 07 / 0 43 4 3 080 / 0 4 Hand-held remote control
Planning Manual Hand-held remote control Connection diagram (new X3 clamp) Series from 0/007 ) > 0/03 Ergoline Prestige 400 ) Ergoline Prestige 00 ) Ergoline Prestige 000 ) Ergoline Prestige-S / Prestige Ergoline Esprit-S / Esprit Ergoline Open Sun Pilot Sunangel Duo 400 ) Sunangel Duo S Sunangel S Sunangel Duo 00 ) Beauty Angel CHP plus The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge New X3 clamp: grey yellow 3 white 4 brown green green-yellow 07 / 0 4 3 07 / 0 Hand-held remote control
Hand-held remote control Planning Manual Connection diagram (new X3 clamp) Ergoline Passion-S Ergoline Flair Beauty Angel C 8 The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge New X3 clamp: grey yellow 3 white 4 brown green green-yellow 4 07 / 0 3 400 / 0 Hand-held remote control
Planning Manual Hand-held remote control Connection diagram (connection ST) Ergoline Sunrise Beauty Angel CVT 4 The connecting cable () of the manual control unit is routed through the cable channel to the top section of the professional device. The connector (3) on the manual control unit is plugged into the jack (4) of the transformer () connection cable. The control cable () from the transformer to the professional device is hooked up directly to the terminal (7) of the professional device. If the connection cable for the manual control unit with microprocessor should be extended (max. 0 m), then a flexible, shielded control cable (8 x 0. mm², item number 7000740 / part number 0740) must be used.. Manual control unit with microprocessor. Manual control unit control cable 3. Control cable plug 4. Transformer jack. Transformer (30 V to 4 V, item number 000083). Control cable 7. Connection strip in professional device (ST) Connection ST: Wire Colour Terminal block black (Start/remote start) black (Start/remote start) 3 black 3 (Lamps ON) 4 black 4 (Lamps ON) black (N) 7 black 7 (30 V) 8 greenyellow 8 (PE) ) B = bridge B ) 43 / 0 Hand-held remote control 7
Hand-held remote control Planning Manual Connection diagram (ST clamp) Ergoline Essence Ergoline Balance 440 Beauty Angel CVT 3 Beauty Angel CT 8 The plug on the hand-held remote control () must be removed. The control cable () is connected directly to the connection strip (3) of the professional device.. Hand-held remote control with micro-processor. Connection cable (control line) 3. Connection strip in professional device 4. Bridge ST clamp: grey yellow 3 white 4 brown green green-yellow 07 / 0 8 Hand-held remote control