Minicap FTC260, FTC262

Similar documents
Capacitive Limit Detection minicap FTC 260, FTC 262

Technical Information Minicap FTC260, FTC262

Assembly. Function 41

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Liquipoint T FTW31, FTW32

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Capacitance level switches LS 210 LS 220

Soliphant M FTM50, FTM51, FTM52

Operating Instructions Soliswitch FTE20

FOR LIQUIDS AND SOLIDS

Liquiphant T FTL20. Technical Information. Level limit switch for liquids

CAPACITIVE: CONTROL CLS2 CLS4 CLS5. Applications liquids / solids liquids / solids solids / granules

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

Technical Information Promonitor NRF560

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

LS 5000 series Vibration Level Switch for liquids

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

LS 6600 Technical Datasheet

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Continuous level measurement Radar transmitters

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Technical Information Liquipoint FTW23

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids

ISO-9001:2000 certified. SAL Series RF Admittance Point Level Sensor. Aplus Finetek Sensor, Inc.

Technical Information RIA16

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level measurement CleverLevel LBFI Point level detection

Technical Data Sheet. OPTISWITCH 3000 series Vibration level switch. for solids

SAL Series RF Admittance Point Level Sensor

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

E2Q4 Square Proximity Sensor

Contact protection relay

itemp TMT180 Technical information

Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N

Technical Information RIA15

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Level. Conductive. Level detection. Overview Page 142 VEGAKON series 60 Page 144 EL 1 EL 8 Page 148 Limit switches VEGATOR Page 157

Voltage Current Front-mounting bracket

Level measurement CleverLevel LBFI Point level detection

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Technical Information RIA16

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Thread length (overall length) material

4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops

Level limit switch Series RF 3000 Selection list. Overview 2

Level measurement CleverLevel LBFH Point level detection

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Solid-state Timer H3YN

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Series 3730 Electropneumatic Positioner Type

WirelessHART Adapter SWA70

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

PHOENIX CONTACT - 07/2006

Temperature Switches

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Operating Instructions for Level Switch for Liquids. Model: RFS

Level sensor Stainless steel version Model RLT-1000, for industrial applications

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

BUFFER MODULE SHORT-FORM DATA MARKINGS

Photoelectric Sensors E3F2

02/11/2015

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Continuous level measuring system NB 3000 Selection list

Suitable for detecting transparent films or transparent bottles

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP

Flow Measurement SITRANS F M

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Flow Measurement SITRANS F M

Electronic pressure switch with display For sanitary applications Model PSA-31

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet December 2014 IP207, Rev DA

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Technical information Soliphant M FTM50, FTM51, FTM52

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Operating Instructions

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Three-phase monitoring relay

Model Number Structure

Product information. Guided Wave Radar. Level measurement in bulk solids VEGAFLEX 82 VEGAFLEX 86. Document ID: 46598

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

SITOP in the SIMATIC Design

Series 3730 Type Electropneumatic Positioner

RTU500 series Data Sheet Power Supply CP-E 24/2.5

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Safety switches with separate actuator

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Redundancy Module QUINT-DIODE/40

Technical Data. General specifications. Rated operating distance s n 3 mm

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

SIY. Features. PC-Programmable Signal Isolator/Converter

Operating Instruction

Transcription:

Technical Information Minicap FTC260, FTC262 Capacitive Limit Detection Compact switch for limit detection with active build-up compensation, no calibration necessary Version available for dust explosion areas Applications Minicap is designed for limit detection of light bulk solids, with a grain size up to max. 1.2" (30 mm) and a dielectric constant ε r 1.6, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum. Versions: Minicap FTC260 (left): with 5.5" (140 mm) rod probe, with FDA listed material; for bulk solids and liquids Minicap FTC262 (right): with max. 236" (6 m) cable probe; for bulk solids Relay output (potential-free change-over contact / SPDT) with AC or DC power PNP output with three-wire DC power Your Benefits Complete unit consisting of the probe and electronic insert: simple mounting no calibration on start-up Active build-up compensation accurate switch point even with heavy build-up on the probe high operational safety Mechanically rugged no wearing parts long operating life no maintenance The cable probe of the Minicap FTC262 can be shortened optimum matching to the measuring point in the silo less stock required TI 287F/24/ae

Table of contents Function and system design..................... 3 General Information................................... 3 Measuring principle................................... 3 Measuring System.................................... 6 Input...................................... 6 Measured variable.................................... 6 Measuring range...................................... 6 Output..................................... 6 Output signal........................................ 6 Signal on alarm...................................... 6 Switching delay when free or covered...................... 7 Overvoltage category.................................. 7 Protection class...................................... 7 Power supply................................ 7 Electrical connection.................................. 7 Supply voltage....................................... 8 Terminal compartment................................. 8 Performance characteristics..................... 8 Reference operating conditions........................... 8 Hysteresis........................................... 8 Switch point......................................... 8 Power up response.................................... 8 Long-term drift....................................... 8 Influence of medium temperature......................... 8 Human interface............................ 13 Display elements.................................... 13 Operating elements.................................. 13 Certificates and approvals..................... 13 CE approval........................................ 13 Ex approval........................................ 13 Overspill protection FTC260........................... 13 Ordering information......................... 14 Product structure FTC260............................. 14 Product structure FTC262............................. 15 Accessories................................ 15 Adapter........................................... 15 Transparent cover................................... 15 Cable shortening set.................................. 15 Supplementary documentation................. 16 Operating manual (BA)............................... 16 Safety instructions (XA)............................... 16 Operating conditions.......................... 8 Installation.......................................... 8 Installation instructions FTC260.......................... 9 Installation instructions FTC262......................... 10 Environment............................... 11 Ambient temperature range T1.......................... 11 Ambient temperature limits............................ 11 Storage temperature.................................. 11 Climate class....................................... 11 Degree of protection.................................. 11 Shock resistance..................................... 11 Vibrational resistance................................. 11 Electromagnetic compatibility........................... 11 Process................................... 11 Process temperature range T2........................... 11 Process temperature limits............................. 11 Process pressure range................................ 11 Temperature diagrams................................ 11 Mechanical construction...................... 12 Design, Dimensions.................................. 12 Material for wetted parts.............................. 13 Process connections.................................. 13 Housing........................................... 13 2 Endress+Hauser

Function and system design General Information Technical specifications to DIN 19259 Measuring principle Limit Detection A metal plate at the end of the probe, within the insulation, and the integrated counter-electrode together with the surroundings combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the Minicap switches. Active Build-up Compensation The Minicap detects build-up on the probe and compensates for its effects so that the switch point is always accurate. The effects of build-up compensation depend on: the thickness of the build-up on the probe, conductivity of the material, the sensitivity setting on the electronic insert. Setting the Sensitivity The Minicap is so calibrated at the factory that it correctly switches in most cases. Greater sensitivity can be set using a multi-pole switch on the electronic insert. This is only necessary, however,if there is very strong build-up on the probe, or if the dielectric constant of the material ε r is very small. LEDs MIN MAX A B C D FTC262 10.8V 45V DC + 1 2 3 DC PNP I max 200 ma 1 2 3 Switch position Maximum fail-safe Sensitivity Factory setting on switches L00-FTC26xxx-15-06-xx-en-001 Endress+Hauser 3

Function Range There is a loose relationship between the dielectric constant ε r and density ρ of the material. However, this depends on the solid. The table on the left indicates whether the Minicap can be used or if application limits are exceeded. Grain, seed, legumes and their products Examples ρ in lb/ft 3 (g/l) (approx.) ε r (approx.) Function Rice 48.1 (770) 3.0 yes Cornstarch (packed) 42.5 (680) 2.6 yes Flour (wheat) 36.3 (580) 2.4 yes Corn grist 31.2 (500) 2.1 yes Sunflower seeds 23.7 (380) 1.9 yes Noodles 23.1 (370) 1.9 yes Bran (wheat) 15.6 (250) 1.7 yes Popcorn 1.87 (30) 1.1 no Minerals, inorganic materials Cement 65.5 (1050) 2.2 yes Plaster 45.6 (730) 1.8 yes Chalk (packed) 33.7 (540) 1.6 (yes) Chalk (loose) 22.5 (360) 1.4 no Plastics ABS granulate 39.3 (630) 1.7 yes PA granulate 38.7 (620) 1.7 yes PE granulate 34.9 (560) 1.5 no PVC powder 34.3 (550) 1.4 no PU-PU dust 4.9 (80) 1.1 no Grey background: Application limits of Minicap exceeded. Recommendation: Soliphant FTM to be used. In general: If the dielectric constant of the solid is not known, then the density (apparent weight) of the solid is a deciding factor. Under normal conditions the Minicap functions in foodstuffs with a density of 15.6 lb/ft 3 (250 g/l) and above or in plastic or mineral materials with a density of 37.5 lb/ft 3 (600 g/l) and above. 4 Endress+Hauser

Minimum/Maximum Fail-Safe Mode The Minicap FTC260 can be set to minimum or maximum fail-safe mode (see following table). AC or DC version with relay output (potential-free change-over contact): Maximum fail-safe mode: The relay is de-energized when the probe is covered or the power supply fails. Minimum fail-safe mode: The relay is de-energized when the probe is free or the power supply fails. DC version with PNP output: Maximum fail-safe mode: The switch output is blocked when the probe is covered or the power supply fails. Minimum fail-safe mode: The switch output is blocked when the probe is free or the power supply fails. Switch position Level Relay output SPDT Transistor output PNP Red LED for switching status Green LED for Stand-by Probe covered 3 4 5 Relay de-energized 1 3 L+ Blocked Maximum fail-safe mode Probe free 3 4 5 Relay energized 1 3 L+ + Connected 3 4 5 1 L+ 3 + Probe covered Relay energized Connected Minium fail-safe mode Probe free 3 4 5 Relay de-energized 1 3 L+ Blocked U 0V Power failure 3 4 5 Relay de-energized 1 3 L+ Blocked Selecting the switch position and function L00-FTC26xxx-15-06-xx-en-002 Endress+Hauser 5

Measuring System Minicap is an electronic switch. The complete measuring system consists of: the Minicap FTC260 or FTC262 a power supply and controllers, switching devices, signal transmitters (e.g. lamps, horns, PCS, PLC, etc.) FTC262 FTC260 MAX MIN FTC260 Limit detection in silos containing solids L00-FTC26xxx-14-06-xx-xx-001 Input Measured variable Limit detection Measuring range FTC260: ε r 1.6 FTC262: ε r 1.5 Output Output signal Signal on alarm DC, PNP transistor output: Switching: PNP I max 200 ma overload and short circuit protection residual voltage at transistor at I max < 2.9 V AC/ DC, Relay output: Contact: change-over, potential-free U~ max 253 V, I~ max 4 A (AC) P~ max 1000 VA, cos ϕ = 1 P~ max 500 VA, cos ϕ > 0.7 I% max 4 A up to U% 30 V (DC) I% max 0.2 A up to U% 253 V (DC) DC, PNP transistor output: < 100 µa AC/ DC, Relay output: relay de-energised 6 Endress+Hauser

Switching delay when free or covered FTC260: 0.5 s FTC262: 0.8 s Overvoltage category Category III (EN 61010) Protection class Protection class to EN 61010-1 FTC260: Class II FTC262: Class I Power supply Electrical connection To ensure that the Minicap operates safely and without electrical interference, it must be connected to a grounded silo with metal or reinforced concrete walls. For silos made of non-conductive materials, the external ground wire of the Minicap must be connected to a conductive and grounded component which is grounded near the silo. The protective ground can be connected to the internal ground terminal of the Minicap. Connections can be made with standard instrument cabling. See TI 241F/00/en for information on EMC (testing procedures, installation). Connect the potential matching lead (PAL) when using in dust explosion hazardous areas. Note national regulations! Minicap AC or DC connection and relay output F1: Fine-wire fuse to protect the relay contact, dependent on the connected load F2: Fine-wire fuse, 500 ma M: E: Ground connection to silo or metal components on silo Ground F1 3 4 5 1 2 F2 PAL E X E M L1 N GND oder or VAC L+ L max. 253 V/ 4 A max. 1000 VA, cos j = 1 Supply = 20 to 253 VAC Supply = 20 to 55 VDC VDC max. 30 V/ 4 A max. 253 V/ 0.2 A No ground lines (PE) or potential matching lines (PAL) are required with Minicap FTC260. L00-FTC26xxx-04-06-xx-en-001 Minicap with three-cable DC connection; Transistor output PNP F: R: M: E: Fine-wire fuse, 500 ma Connected load, e.g. PLC, PCS, relay Ground connection to silo or metal components on silo Ground 1 2 3 + E X E M F PAL R max. 200 ma L+ L GND V = 10.8 to 45 VDC L00-FTC26xxx-04-06-xx-xx-001 Minicap is protected against reverse polarity. The green LED for standby goes out if the connections are reversed. No ground lines (PE) or potential matching lines (PAL) are required with Minicap FTC260. Endress+Hauser 7

Supply voltage Terminal compartment DC, PNP transistor output: Supply: 10.8 to 45 VDC transient pulses to 55 V current consumption max. 30 ma reverse polarity protected AC/ DC, Relay output: Supply: 20 to 253 VAC or 20 to 55 VDC current consumption max. 130 ma Stranded wires max. 16 AWG (1.5 mm 2 ) in end sleeves Electric wire max. 14 AWG (2.5 mm 2 ) Performance characteristics Reference operating conditions Hysteresis Switch point Power up response Long-term drift Influence of medium temperature (for plastic vessels) Ambient temperature: 74 (23 C) Medium temperature: 74 (23 C) Medium pressure p e : 0 psi (0 bar) Medium: dielectric constant ε r = 2.6 Conductivity: < 1 µs Sensitivity setting: C FTC260: Horizontal 0.16" (4 mm), Vertical 0.28" (7 mm) FTC262: Vertical 0.2" (5 mm) FTC260: Horizontal: center of probe -0.2" ( 5 mm), Vertical: 1.47" (40 mm) above probe tip FTC262: Vertical: 1.38" (35 mm) above probe tip FTC260: Correct switching aftermax. 1.5 s FTC262: Correct switching after max. 2 s FTC260: Horizontal 0.12" (3 mm), Vertical 0.24" (6 mm) FTC262: Vertical 0.24" (6 mm) FTC260: Depending on material to be measured FTC262: Depending on material to be measured Operating conditions Installation Silo Material The Minicap can be installed in a wide range of silos made of different materials (e.g. metal, plastic, concrete). Mounting Point Note the angle of the material mounds and the outlet funnel when determining the mounting point or probe length of the FTC262. The Minicap switches when the probe tip is covered by a few centimeters of material or when it is free. Material flow should not be directed at the probe. 8 Endress+Hauser

Installation instructions FTC260 Correct Installation Incorrect Installation Max. 1 (25) d) a) Min. 8 (200) Min. 4 (100) e) Max. 2 (50) 8 (200) 8 (200) 8 (200) b) f) Min. Max. 314 lb f (1400 N) c) Min. 8 (200) General information and recommendations for installing the Minicap FTC260 limit switch Dimensions in inches (mm) L00-FTC26xxx-11-06-xx-xx-001 Correct Installation a. Minimum distance: To prevent mutual interference with the FTC260, the probes must be at least 8" (200 mm) from each other. b. Mounting point: The tip of the probes must point slightly downwards so that the material can slide off more easily. The protective cover protects the probe rod from collapsing mounds or mechanical strain at the outflow when the Minicap FTC260 is set to minimum detection. c. Mechanical load: The maximum lateral load on the probe rod must be taken into account when used for minimum detection. It should therefore only be used for minimum detection with loose materials that have good flow characteristics. Incorrect Installation d. The probe can be damaged by the inflowing material and cause faulty switching. Cable gland pointed upwards can allow moisture to enter. e. Threaded socket too long with material build-up on the silo wall. (less than the minimum mounting depth of 4" / 100 mm). f. Mounted near build-up in the silo. The probe tip is too near to a silo wall (less than a minimum distance of 8" / 200 mm). Endress+Hauser 9

Installation instructions FTC262 Correct Installation a) Incorrect Installation d) e) Max. Min. 12 (300) b) f) FTC260 Min.12 (300) max. 674 lb f (3000 N) c) Min.12 (300) g) Min. Min. 8 (200) max. 674 lb f (3000 N) General information and recommendations for installing the Minicap FTC262 limit switch Dimensions in inches (mm) L00-FTC26xxx-11-06-xx-xx-002 Correct Installation a. Minimum distances: Sufficent distance from the material filling curtain and the other probe. b. Mounting point: Do not install in the centre of the outlet cone. Ensure there is sufficient distance from the silo wall and from material build-up on the wall. c. Mechanical load: Note the tensile strain on the probe rope and the strength of the silo roof when used for minimum detection. Very high tensile forces may occur at the material outlet especially with heavy, powdery bulk materials which tend to form build-up. These forces are significantly greater over the outlet than at the silo wall. For minimum detection Minicap FTC262 should only be used for light, easily flowing solids, and that do not tend to form build-up. Incorrect Installation d. In the centre of the material outflow; the high tensile forces at this point may tear off the probe or damage the silo roof. e. The probe may be damaged by inflowing material. f. Mounted laterally g. Too near silo wall; when swinging gently the probe can hit the wall or touch any build-up which may have formed. This can result in error switching 10 Endress+Hauser

Environment Ambient temperature range T1 Ambient temperature limits Storage temperature 40 to +160 ( 40 to +70 C) (to +140 / +60 C, Dust-Ex version] (see the temperature diagrams) 40 to +180 ( 40 to +80 C) (to +140 / +60 C, Dust-Ex version] (see the temperature diagrams; grey background) 40 to +180 ( 40 to +80 C) Climate class IEC 68 part 2-38 Degree of protection NEMA 4 (IP66) Shock resistance Probe: 5.2 ft/lbs force (7 J) Vibrational resistance EN 60068-2-64 (IEC 68-2-64), 20 to 2000 Hz, spectral rate of velocity 0.5, 100 min per axis Electromagnetic compatibility Interference Emission to EN 61326, Electrical Equipment Class B Interference Immunity to EN 61326, Annex A (Industrial) and NAMUR Recommendation NE 21 (EMC) See TI 241F/00/en for general instructions regarding the EMC test conditions for E+H instruments. Process Process temperature range T2 Process temperature limits Process pressure range p e FTC260: 40 to +250 ( 40 to +120 C) (to +176 / +80 C, Dust-Ex version) FTC262: 40 to +160 ( 40 to +70 C) (see the temperature diagrams) FTC260: 40 to +270 ( 40 to +130 C) (to +176 / +80 C, Dust-Ex version) FTC262: 40 to +180 ( 40 to +80 C) (see the temperature diagrams; grey background) FTC260: 14.5 to +360 psi ( 1 to +25 bar) FTC262: 14.5 to +90 psi ( 1 to +6 bar) Temperature diagrams FTC260 T1 176 158 122 EX T1 140 E X 40 40 176 158 248 266 T2 40 40 176 T2 L00-FTC26xxx-05-06-xx-xx-001 FTC262 T1 176 158 E X T1 140 E X 40 40 176 158 T2 40 40 158 176 T2 L00-FTC26xxx-05-06-xx-xx-002 Endress+Hauser 11

Mechanical construction Design, Dimensions (in mm) Minicap FTC260 Minicap FTC262 Max. 3.94 (100) 3.70 (94) Max. 3.94 (100) 3.70 (94) ~3.54 (90) 41 AF ~0.79 (20) ~3.74 (95) 50 AF 1 NPT 1-1/2 NPT ~0.98 (25) Wall thickness 0.2 (5) 5.51 (140) 3.07 (78) 0.31 (8) Top view, FTC260 and 262 1.26 (32) L min. 20 (500) L max. 236 (6000) Adapter for FTC260 Max. 1.65 (42) 55 AF ~ 10.6 (270) 1.57 (40) 1-1/4 NPT 1 NPT female 1-1/4 NPT: Carbon steel, PN: 943215-0042 316 TI SS, PN: 943215-0043 Probe length tolerances: L00-FTC26xxx-06-06-xx-en-002 Proble length L Up to 40" (1000 mm) Up to 120" (3000 mm) Up to 236" (6000 mm) Tolerances +0, -0.4" (-10 mm) +0, -0.8" (-20 mm) +0, -1.2" (-30 mm) 12 Endress+Hauser

Material for wetted parts Probe rod FTC260: PPS = Polyphenylene sulphide (fiberglass content approx. 40%), FDA listed Probe length: FTC260: 5.5" (140 mm) FTC262: min. 20" (500 mm), max. 236" (6000 mm) Flexural strength FTC260: 314 lbs f (1400 N), at probe tip Probe rope FTC262: Surface in High Density PE over steel coating Other probe parts FTC262: PPS = Polyphenylene sulphide (fiberglass content approx. 40 %) Tensile strength F of FTC262: Max. 674 lbs f (3000 N) up to 104 (40 C), max. 629 lbs f (2800 N) at 176 (80 C) F Lb f 674 630 40 32 104 176 T2 L00-FTC26xxx-05-06-xx-xx-003 Process connections Housing Threaded boss: FTC260: 1 BSPT (R 1, ISO 7/1); Adapter for 1½ BSPT and 1½ BSP (G 1½) see accessories 1" NPT, ANSI B 1.20.1; Adapter for 1-¼" NPT see accessories FTC262: 1½ BSPT (R 1½, ISO 7/1) 1-½" NPT, ANSI B 1.20.1 Housing F14: Polyester PBT-FR, NEMA 4 (IP66) Human interface Display elements Operating elements Green LED: stand-by Red LED: switch status Switch on electronic insert switching between minimum and maximum fail-safe mode sensitivity setting (depends on the dielectric constant ε r and build-up). A sensitivity adjustment is normally not required (see section "Measuring principle") Certificates and approvals CE approval Ex approval Overspill protection FTC260 In attaching the CE Mark, Endress+Hauser confirms that the device conforms to all relevant EU directives. ATEX, FM, CSA See section Product structure DIBt, General design approval Endress+Hauser 13

Ordering information Product structure FTC260 10 Approval A Non-hazardous area D Non-hazardous area, WHG B ATEX II 1/3 D U CSA, General purpose S CSA, DIP Cl. II Gr. E-G, Cl. III J FM, DIP Cl. II, III Gr. E-G, T5 Y Special version 20 Process connection A Thread DIN2999 R 1, PPS B Thread ANSI NPT 1, PPS Y Special version 30 Switch output 2 3-wire PNP 10.8 to 45 V DC 4 Relay 20 to 253 V AC / 20 to 55 V DC 9 Special version 40 Housing, Cable entry B F14 Polyester NEMA 4 (IP66) Thread NPT ½ C F14 Polyester NEMA 4 (IP66) Thread G ½ D F14 Polyester NEMA 4 (IP66) Gland M20 Y Special version 50 Additional option 1 Basic version 2 Transparent cover 9 Special version FTC260 Product designation 14 Endress+Hauser

Product structure FTC262 10 Approval A Non-hazardous area B ATEX II 1/3 D U CSA, General purpose S CSA, DIP Cl. II, III Gr. G+coal dust Cl. III J FM, DIP Cl. II, III Gr. E-G, T5 Y Special version 20 Process connection A Thread DIN2999 R 1 ½, PPS B Thread ANSI NPT 1 ½, PPS Y Special version 30 Probe length, L=20 to 236 inch (500 to 6000 mm) 1... mm L (500 to 6000 mm) steel HD-PE insulated 2... inch L (20 to 236 inch) steel HD-PE insulated 3 59 inch (1500 mm) steel HD-PE insulated 4 98 inch (2500 mm) steel HD-PE insulated 5 157 inch (4000 mm) steel HD-PE insulated 6 236 inch (6000 mm) steel HD-PE insulated 9 Special version 40 Switch output 2 3-wire PNP 10.8 to 45 V DC 4 Relay 20 to 253 V AC / 20 to 55 V DC 9 Special version 50 Housing, Cable entry B F14 Polyester NEMA 4 (IP66) Thread NPT ½ C F14 Polyester NEMA 4 (IP66) Thread G ½ D F14 Polyester NEMA 4 (IP66) Gland M20 Y Special version 60 Additional option 1 Basic version 2 Transparent cover 9 Special version FTC262 Product designation Accessories Adapter Transparent cover Cable shortening set FTC260, 1 BSPT female (R c 1), ISO 7/1 (see dimensional sketch): Part No.: 943215-1001, for 1½ BSPT (R 1½ ISO 7/1), PPS Part No.: 943215-1021, for 1½ BSP (G 1½ DIN ISO228), PPS FTC260, 1 NPT female: Part No.: 943215-0042, for 1¼ NPT, steel Part No.: 943215-0043, for 1¼ NPT, AISI 316Ti (1.4571) FTC260/262: Part No.: 943201-1001 FTC262: Part No.: 52005918 Endress+Hauser 15

Supplementary documentation Operating manual (BA) Safety instructions (XA) Minicap FTC260 KA093F/00/a6 017476-0000 Minicap FTC262 KA155F/00/a6 52005985 Cable shortening set for FTC262 KA157F/00/a6 Safety instructions (ATEX) for FTC260 XA011F/00/a3 4 0 II 1/3 D 52000928 Safety instructions (ATEX) for FTC262 XA092F/00/a3 4 0 II 1/3 D 52005988 United States Canada Mexico Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 Tel. 317-535-7138 Sales 888-ENDRESS Service 800-642-8737 Fax 317-535-8498 inquiry@us.endress.com www.us.endress.com Endress+Hauser Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel. 905-681-9292 800-668-3199 Fax 905-681-9444 www.ca.endress.com Endress+Hauser, México, S.A. de C.V. Av. Gustavo Baz No. 43 Fracc. Bosques de Echegaray Naucalpan de Juárez, C.P. 53310, Estado de México México Tel: (52) 55-5371-1110 Fax (52) 55-5371-1128 eh.mexico@mx.endress.com TI287F/24/ae/08.05 2005 Endress+Hauser, Inc. 16 Endress+Hauser