Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4 Modular Data Centers T4 ISO Data Centers T4 Data Center POD s SOLUTIONS T4 Data Center Components T4 Data Center Manager T4 Plant & Machinery T4 Data Centers Complete Turnkey data center solutions from design through to support created in client buildings. T4 Mini Data Centers Single Rack data center with all infrastructure components within a single enclosure. T4 Modular Data Centers A modular room with power and cooling for multiple racks or large system components. T4 ISO Data Centers ISO Containerized data center solutions for high density loads and mobile applications. T4 Data Center POD s Aisle containment POD solutions for new or existing data centers. T4 Data Center Components Component products to enhance existing non T4 solutions. T4 Data Center Manager A state-of-the-art, remote or local management, monitoring and alarm system.
Grey is the New Green Order Chameleon Grey White to reduce your electricity bill Reduce your Electricity Bill for Lighting by up to 40% Customers confirm that our Grey White (RAL 9002) rack color has reduced Data Center lighting needs by up to 40% when compared to the lighting needs for their black racks. So our Grey White is the new Green which is why we call it "Chameleon" (Of course we are happy to sell "Velvet Black" racks as well)
SOLUTIONS A i s l e C o c o o n i n g The Cannon Aisle Cocooning System provides segregation of cold aisle air flow from hot aisle exhaust air in data centers. By preventing the contamination of cold air by hot air, the full effect of this cooling resource is available to servers and other power hungry equipment contained in IT enclosures, ensuring effective cooling. Servers mounted at the upper levels of a cabinet are particularly prone to overheating due to the combined effects of: Upwards heat convection and radiation, from equipment below Heat gradient up the vertical height of the computer room Undesirable air recirculation, in which hot exhaust air is pulled to the front of the enclosure, re-entering the server with damaging effect. This is often called air scavenging Aisle Cocooning, usually of the cold aisle, dramatically lowers the cold air temperature available to the servers by preventing contamination of the cold air by hot/exhaust air. This protects equipment against damage, prolongs equipment life, reduces the load on the computer room air conditioning and saves energy, reducing carbon footprint. Visit www.cannont4inc.com/cannon_videos.html and see Cannon s Aisle Cocooning video for the full picture Cannon Aisle Cocooning is a component of Cannon T4 Data Center Solutions Aisle Cocooning Features and Benefits Segregated cold aisle air flow from hot aisle air flow Maximizes cooling effect of cold aisle Reduces workload of computer room air conditioning Reduces energy cost Reduces carbon footprint Passive cocooning versions Active cocooning versions with automated roof panel opening for instances of fire Totally integrated with cabinet infrastructure Not connected to the building Can be quickly installed Easily relocated CannonGuard remote management upgrades Can be retrofitted to existing bays of enclosures with the use of customizing kits Within aisle lighting upgrades For details please see the Cannon Aisle Cocooning Brochure
Cannon T4 Modular Data Center (MDC) For outside deployment and challenging environments Features & Benefits Rapid deployment Assembled onsite with manual handling only - no cranes or large machinery required No road closures required Shipped in containers or crates worldwide Expandable, scaled growth High density configurations Low CapEx Low OpEx Low carbon footprint Traditional white space normal data center width aisles Cold & Hot Aisle Cocooning integrated Free Form Aisle Cocooning / Infrastructure - allows simple deployment of third party racks and equipment into the aisle containment solution NOC, UPS, Battery, Meet Me, entry vestibule space(s) incorporated Highly secure building Cable management and containment included within the design - static cable system, no flexible connections to the racks required Cooling systems: Water or DX - traditional and eco Power systems: Busbar, Whips, intelligent power distribution Fire protection and suppression Full range of Racks / Cabinets available including the award winning Smart Space Cabinet Full turnkey systems available www.cannont4inc.com
Cannon T4 Modular Data Center (MDC) Specification Specification Construction Weatherproof galvanized powder coated steel for long life Non-combustible materials used throughout Thick insulated walls to cope with extremes of temperature Foundations Simple concrete slab No foundations - Car park, hangar, warehouse floor, etc White Space Well lit and airy working environment Easy integration of third party racks and equipment Office, NOC, Air Lock entry space(s) available Racks / Cabinets Various U heights, sizes, colors Data Center Managed systems o Access / Security / CCTV o Power control o Environmental Monitoring Full range of rack accessories including air management Site Assembly Assembled using hand tools, no wet trades or hot works Rapid construction and availability Site construction service available worldwide
Cannon T4 Modular Data Center (MDC) Options Options Any size, Any shape, Anywhere Cooling solutions: o Integrated WithIn Row Cooling - Water or DX o Traditional CRAC or Eco type wall edge cooling o Water chillers, M&E, installation o Leak detection Power solutions: o Integrated UPS, batteries in aisle or room edge o Power Distribution Units, Cabling containment o Static or rotary UPS systems available Cabling infrastructure and containment Fully configured network solutions (Including servers) Fire protection systems: gas, water sprinkler or combination to suit the area of deployment Cabinet and aisle environmental monitoring Green lighting systems: occupancy and LED Remote monitoring using Cannon T4 Data Center Manager (DCM): o Environmental o Power & alarms o Access security o Cooling & PUE o Rack: biometric or pin code entry, remote alarms, multiple temperature sensors and more Access ramps. Loading areas and steps Multiple wide doors: optional electrical operation To discuss your requirements and to visit a demonstration facility to see a built Cannon T4 Modular Data Center please call us Toll Free on: (855) 398-2733 or Email: sales@cannont4inc.com
Cabinets, Racks & Accessories T4 Free Form Infrastructure Aisle Cocooning Air Management Solutions T4 Modular Data Center (MDC) To request a different product brochure please call us Toll Free on: (855) 398-2733 Cannon T4 Inc. 21641 Beaumeade Circle, Unit 315, Ashburn, VA 20147. USA www.cannont4inc.com For all Cannon office locations please visit www.cannont4inc.com All the information given herein, including illustrations, graphs and technical illustrations are believed to be reliable at time of going to print. Cannon makes no guarantees as to its accuracy or completeness and disclaims any liability regarding to its use. We advise that the user should evaluate the suitability of our products for each specific application. Cannons responsibilities are only those listed in our Standard Terms and Conditions of Sale, and in no instance will Cannon be liable for any incidental, indirect or consequential damages arising from sale, resale, transfer or misuse of the products. Cannon Technologies and the Cannon logo are registered trademarks of the Cannon Technologies Group. OCT/13/SBJJIGSAW