Modular data centres in containers

Similar documents
RiMatrix S Make easy.

LCP Hybrid Efficient performance with heat pipe technology

Perfect Cooling. A perfect climate for high performance servers

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems

Rittal LCP T3+ High-availability IT cooling with no compromise

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

PRESSEINFORMATION. RiMatrix S: First order received. Wollschläger Group buys off-the-peg data centre

Data Centre In A Box

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

84 kw, Tier 3, Direct Expansion, 937 ft 2

White paper adaptive IT infrastructures

Rittal The System. White paper RiMatrix S A strategy for designing standardised data centres. Faster better worldwide

Dazelidis Thanos - Product Manager Rittal Greece 1

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Total Modular Data Centre Solutions

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Thermal management. Thermal management

Efficiency of Data Center cooling

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Switch to Perfection

Rittal Cooling Solutions A. Tropp

Rittal RiZone Data Centre Management Software

200 kw, Tier 3, Chilled Water, 5250 ft 2

IT Air Conditioning Units

1008 kw, Tier 2, Chilled Water, ft 2

IT solutions prepared for the tasks of tomorrow.

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Service Perfect all-round support package for your data centre

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Green Data Centers A Guideline

Close-coupled cooling

Rack & Enclosure Systems

Blue e+ chillers with the principle

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Modular Services. Comprehensive services for maximum operational reliability and effi ciency

STATE-OF-THE-ART INFRACTRUCTURE FOR HPC. Alessio Casagrande Product manager & Solution Architect Div.IT & Telecomunicazioni 1

System solutions for your energy requirements

SmartMod Intelligent, Integrated Infrastructure for the Data Center

DATACENTER CAMPUS FRANKFURT. Plan for Every Second

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

White Paper RiZone The Rittal Management Software for IT infrastructures

Industry leading low energy evaporative fresh air cooling.

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Liebert DCW CATALOGUE

The Shared Data Centre Project

White Paper - Infrastructure in an energy-efficient data centre

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

WELCOME TO THE FUTURE OF CONNECTION AND PROTECTION

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

18 th National Award for Excellence in Energy Management. July 27, 2017

Ecotel Free Cool 5-15kW

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Power and Cooling for Ultra-High Density Racks and Blade Servers

HPC Solutions in High Density Data Centers

Smart Monitoring System compact, secure, efficient

Close Coupled Cooling for Datacentres

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Green IT and Green DC

COLOCATION 1/4 RACK RACK COLD AISLE CONTAINEMENT PRIVATE CAGE PRIVATE SUITE FLEXIBLE PRICING OPTIONS

M+W Group s Visionary Delta Datacenter

WIRELESS ENVIRONMENTAL MONITORS

Next Generation Cooling

DATACENTER BERLIN Definitely a Good Perspective

30 th September Always Right Size Modular Data Centres. Cannon Technologies Ltd (2015)

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Planning a Green Datacenter

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

One Stop Cooling Solution. Ben Tam Business Development Manager

ENCLOSURE HEAT DISSIPATION

Comprehensive Data Center Energy Management Solutions

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

APC APPLICATION NOTE #146

Data Center Energy and Cost Saving Evaluation

It`s the size of science & research...

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

Data Center Design: Power, Cooling & Management

Constru January 15, 2013

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

) ) page 04. page 07. page 10. page 10. page 12. page 14. page 14. page 16. page 18. page 19. page 19. page 20. page 21. page 22

Cannon T4 Modular Data Center (MDC)

World Class. Globally Certified. High Availability.

Datacentre Reading East 2 Data sheet

Transcription:

Modular data centres in containers

2 Modular data centres

Contents IT Containers based on the modular principle.. 4 5 Edge Data Center... 6 7 RiMatrix Data Center Container IT Containers 50 100 kw... 10 11 IT Containers 200 kw... 12 13 All-in-One Containers 35 180 kw... 14 15 Customized solutions... 16 17 Cooling and power supply... 18 21 IT as a service... 22 23 Modular data centres 3

RiMatrix Cooling Container: Efficient recooling systems in the container frame, ready to connect and system-tested with redundant chillers, free-cooling mode or additional free cooler and network functions RiMatrix Data Center Container: Ready-to-connect IT infrastructure in a robust container shell, as standardised IT modules in a range of output categories for SME, Cloud and Edge applications Network racks: Pre-configured type TS IT for installing network technology and structured cabling, with two PDUs for redundant power supply Server racks: Pre-configured type TS IT for server installation, with cable guide rails and two PDUs for redundant power supply in the server exhaust air zone 4 Modular data centres

IT containers based on the modular principle Growing data volumes and escalating requirements are a common cause of problems in existing IT environments. Container solutions for outdoor siting are one possible answer to this problem. For the conventional components of rack, power, cooling and monitoring, Rittal and its strategic partners Innovo Cloud and Lefdal also offer IT as a Service, together with a location the Lefdal Mine Datacenter in Norway which can save up to 40 percent energy costs compared with a data centre in Germany. RiMatrix Power Container: Modular UPS systems with redundancy to supply one or more IT modules Low-voltage distributor: Complete distributor system with connection point for the main supply and the outgoing feeders from all PDUs IT cooling: Cold water or coolant-based systems for energy-efficient cooling of the entire server inlet air zone, speed-controlled and with n+1 or n+n redundancy Modular data centres 5

6 Modular data centres

Edge Data Center modular and scalable The digital transformation means a radical shake-up. New technologies such as smart cities, connected cars, streaming services, Industry 4.0 and mobile data offer new opportunities, but also necessitate the storage and rapid processing of huge volumes of data. This creates a demand for ever more flexible and modular IT solutions. Ideally, these should be located where the data is produced, i.e. locally and close to the user. This is where Edge Data Centers come into their own, combining short latency times with exceptional computing power and optimum reliability. Rittal Edge Data Center solutions are available with 2, 4 or 6 racks, incorporating predefined components for energy supply, cooling, IT security and monitoring. Of course, the data centre may be installed in a container for flexible siting. Modular data centres 7

8 Modular data centres

RiMatrix Data Center Container For SME, Cloud and Edge applications Container solutions from Rittal are delivered pre-assembled, and can be up and running in next to no time. The spectrum ranges from simple IT containers to complete all-in-one systems incorporating the entire physical IT infrastructure, from the rack, to climate control, a power supply with a powerful UPS system, through to complete monitoring and, at the customer s request, an effective fire extinguisher system. The product spectrum comprises multiple graduations and output categories, allowing you to select the most suitable solution for your requirements. ISO High Cube dimensions are also supported. Extensive standardisation within the product family not only shortens the delivery time, it also enhances product reliability and quality. The field-tested solutions are delivered complete with comprehensive documentation. Modular data centres 9

RiMatrix Data Center IT Container Version RDC-IT 50/10-L-III RDC-IT 60/12-L-II Maximum total IT output in kw 50 60 Maximum IT output per rack in kw 5 5 Redundancy of cooling system 2n n+1 Redundancy of power supply 2n 2n Cooling concept Power concept Racks Current LCP systems are positioned between the racks, and depending on the variant, are either fl ush with or set forward from the enclosure suite. These systems cool the entire cold aisle in front of the servers and have a redundant design in the container variants. The variants with a second set of cold water pipelines also support n+n redundancies. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply to which one or two UPS-buffered supply lines may be connected. A RiMatrix Data Center Power Con tainer with integral UPS may also be used to supply the containers. The container peripherals are supplied via an additional C-line. Server rack W x H x D mm 600 x 2000 x 1200 10 12 Network rack W x H x D mm 800 x 2000 x 1200 1 1 Technical rack W x H x D mm 600 x 2000 x 600 600 x 2000 x 1200 1 1 Low-voltage distributor 1 1 UPS, modular PDU 11 x 2 13 x 2 Quantity 6 x LCP CW 4 x LCP CW Cooling Pipe systems 2 set(s) 1 set(s) Container size L x W x H mm (external dimensions) 12192 (40 ft.) x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 10 Modular data centres

SME, Cloud and Edge applications RDC-IT 90/8-M-I RDC-IT 100/10-L-II RDC-IT 100/10-L-III 90 100 100 10 10 10 n+1 n+1 2n 2n 2n 2n Use of the Zero-U-space cooling system (ZUCS) optimises use of the interior space by positioning the cooling units underneath the racks in the raised fl oor. Effi cient EC fans ensure a constant server inlet air temperature in the shielded cold aisle. This system provides a redundancy of n+1. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply to which one or two UPS-buffered supply lines may be connected. A RiMatrix Data Center Power Container with integral UPS may also be used to supply the containers. LCP systems are positioned between the racks, and depending on the variant, are either fl ush with or set forward from the enclosure suite. These systems cool the entire cold aisle in front of the servers and have a redundant design in the container variants. The variants with a second set of cold water pipelines also support n+n redundancies. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply to which one or two UPS-buffered supply lines may be connected. A RiMatrix Data Center Power Container with integral UPS may also be used to supply the containers. The container peripherals are supplied via an additional C-line. 8 10 10 1 1 1 1 1 1 1 1 1 9 x 2 11 x 2 11 x 2 9 x ZUCS 6 x LCP CW 6 x LCP CW 1 set(s) 1 set(s) 2 set(s) 7250 x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 Modular data centres 11

RiMatrix Data Center IT Container Version RDC-IT 200/10-L-II Maximum total IT output in kw 200 Maximum IT output per rack in kw 20 Redundancy of cooling system n+1 Redundancy of power supply 2n Blob arrangement Cooling concept Power concept Racks Current Server rack W x H x D mm Energy-effi cient LCP systems with a cold water supply are used as cooling systems, and can each produce a cooling output of up to 55 kw. These systems are positioned in the row between the server enclosures and can easily be set forward into the cold aisle. This brings the cold air directly in front of the servers for cooling without defl ection losses. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply to which one or two UPS-buffered supply lines may be connected. A RiMatrix Data Center Power Container with integral UPS may optionally be used to supply the high-performance containers. The container peripherals are supplied via an additional C-line. 600 x 2000 x 800 600 x 2000 x 1200 10 800 x 2000 x 800 Network rack W x H x D mm 800 x 2000 x 1200 1 Technical rack W x H x D mm 600 x 2000 x 1200 1 Low-voltage distributor 1 UPS, modular PDU 11 x 2 Quantity 6 x LCP CW Cooling Pipe systems 1 set(s) Container size L x W x H mm (external dimensions) 12192 (40 ft.) x 3000 x 3000 12 Modular data centres

SME, Cloud and Edge applications RDC-IT 200/10-L-I RDC-IT 200/10-ISO L-I 200 200 20 20 n+1 n+1 2n 2n The racks and cooling systems are arranged so that two racks form a unit with one LCP. This unit is described as a blob and represents an independent functional module in software terms with built-in IT hardware. Energy-effi cient LCP systems with a cold water supply are used as cooling systems, and can each produce a cooling output of up to 55 kw. These systems are positioned in the row between the server enclosures and can easily be set forward into the cold aisle. This brings the cold air directly in front of the servers for cooling without defl ection losses. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply to which one or two UPS-buffered supply lines may be connected. A RiMatrix Data Center Power Container with integral UPS may optionally be used to supply the high-performance containers. The container peripherals are supplied via an additional C-line. 10 10 1 1 1 1 11 x 2 11 x 2 7 x LCP CW 7 x LCP CW 1 set(s) 1 set(s) 12192 (40 ft.) x 3000 x 3000 12192 (40 ft.) x 2438 x 2896 (ISO High Cube) Modular data centres 13

RiMatrix Data Center All-in-One Container Version RDC-AIO 35/3-M-II RDC-AIO 45/8-L-II Maximum total IT output in kw 35 45 Maximum IT output per rack in kw Server rack 10 5 Network rack 5 5 Redundancy of cooling system n+1 n+1 Redundancy of power supply 2n 2n Cooling concept Power concept Racks Current LCP systems are positioned between the racks, and depending on the variant, are either fl ush with or set forward from the enclosure suite. These systems cool the entire cold aisle in front of the servers and have a redundant design in the container variants. Coolant-based DX systems may also be used in the AIO variants, which are linked to the relevant external unit. These may also be optionally secured directly to the outer container sleeve. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply; the integral modular UPS is positioned directly at the infeed to the B-line. The container peripherals are supplied via an additional C-line. Server rack W x H x D mm 600 x 2000 x 1200 3 8 Network rack W x H x D mm 800 x 2000 x 1200 1 1 Technical rack W x H x D mm 600 x 2000 x 600 600 x 2000 x 1200 Low-voltage distributor 1 1 UPS, modular 40 + 20 kw 60 + 20 kw PDU 4 x 2 9 x 2 Cooling Quantity 5 x LCP DX 6 x LCP DX Pipe systems Single Single Container size L x W x H mm (external dimensions) 7250 x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 14 Modular data centres

SME, Cloud and Edge applications RDC-AIO 60/6-M-I RDC-AIO 90/8-L-II RDC-AIO 180/16-L-II RDC-AIO 180/16-L-III 60 90 180 180 10 10 10 10 5 5 5 n+1 n+1 n+1 2n 2n 2n 2n 2n Use of the Zero-U-space cooling system (ZUCS) optimises use of the interior space by positioning the cooling units underneath the racks in the raised fl oor. Effi cient EC fans ensure a constant server inlet air temperature in the shielded cold aisle. This system provides a redundancy of n+1. LCP systems are positioned between the racks, and depending on the variant, are either fl ush with or set forward from the enclosure suite. These systems cool the entire cold aisle in front of the servers and have a redundant design in the container variants. The variants with a second set of cold water pipelines also support n+n redundancies. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. A UPS is already integrated into the RDC-AIO 60/6-M-II. The container main power supply is split among individual outgoing feeders to the PDUs in the individual enclosures via a low-voltage distributor. Each enclosure has an A supply and a B supply, thereby achieving n+1 redundancy. The main distributor offers separate connections for the A and B supply; the integral modular UPS is positioned directly at the infeed to the B-line. The container peripherals are supplied via an additional C-line. 6 8 2 x 8 2 x 8 1 1 2 x 1 2 x 1 1 1 1 2 x 1 2 x 1 60 + 20 kw 100 + 20 kw 2 x (100 + 20 kw) 2 x (100 + 20 kw) 7 x 2 9 x 2 2 x (9 x 2) 2 x (9 x 2) 6 x ZUCS for server zone 1 x ZUCS for UPS zone 6 x LCP CW 2 x (6 x LCP CW) 2 x (6 x LCP CW) 1 set(s) 1 set(s) 2 x 1 set(s) 2 x 2 set(s) 7250 x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 12192 (40 ft.) x 3000 x 3000 Modular data centres 15

Container sleeves in a variety of sizes and levels, from S to L, also available as ISO High Cube variants, with flexible doors and openings Pre-configured racks of the type TS IT, as a server rack with 600 mm width or as a network rack with 800 mm widths, depths variable at 800 mm, 1000 mm or 1200 mm Integrated partitions and container peripherals, individual solutions for container configuration Cooling solutions in various stages adapted to the required server output, redundant versions available, depending on the container and output variant Power supply to the racks via PDUs, separate PDUs for A and B lines, measurement and switching functions supported by a network interface Modular raised floor, height depending on cooling solution and installed racks 16 Modular data centres

RiMatrix Data Center Container Customized Container solutions for individual requirements Of course, we can also build you an individually planned data centre solution in a container to meet your specific requirements. There are no limits to the construction of individual data centre containers, from small main data centres, to Edge and Fog installations, through to large modular cloud data centres. Individually planned containers are also supplied pre-assembled. They are more complex than a standardised solution, and above all, entail more intensive planning, not only in terms of infrastructure design, but also with the complete documentation and consideration of errors in the designed solution. With maximum heat losses of between 30 and 200 kw, a RiMatrix Data Center Container can incorporate unlimited intermediate procedures and applicable technologies from the IT portfolio. As well as offering advice, Rittal itself can also provide complete conceptualisation and planning of a container data centre. Integral or external UPS, modular UPS modules for a redundant power supply Early fire detection with alarm forwarding to management systems, integral extinguisher system optionally available Monitoring components as integral hardware, individual quantities of measurement sensors, optionally with DCIM software Integral low-voltage power distributor, two separate paths for redundant supply to the racks, offset distribution for the container peripherals Modular data centres 17

18 Modular data centres

Cooling and power supply to suit all output classes Complete plug & play cooling and power supply solutions are available to match the container portfolio. Benefits of plug & play solutions: Co-ordinated systems for fast and simple commissioning System-tested software to control all components, including emergency mechanisms Individual control and monitoring via an integral TCP/IP interface Modular data centres 19

Containers for cooling Version RDC-C 200/2-ISO L-II RDC-C 70/2-M-II RDC-C 100/2-M-II Total output in kw 60 to 200 kw 1) 70 100 Equipment Characteristics 2 x chillers (redundant) with integral free coolers Pipework Separate chiller systems with independent regulation and control, mounted on a container frame. Free cooler 2 x chillers (redundant) Control and hydraulic station PLC controller with network Energy-effi cient cooling with superordinate control of all components. The integral controller regulates a constant water inlet temperature depending on the external temperature and the status messages from the components. Redundancy Chillers: 2n Chillers: 2n Chillers: 2n To fi t Container size L x W x H mm (external dimensions) 1) Higher outputs available on request. RDC-IT 50/10-L-III RDC-IT 60/12-L-II RDC-IT 100/10-L-II RDC-IT 100/10-L-III RDC-IT 200/10-L-II RDC-IT 200/10-L-I RDC-IT 200/10-ISO L-I RDC-AIO 90/8-L-II RDC-AIO 180/16-L-II RDC-AIO 180/16-L-III 12192 (40 ft.) x 2438 x 2896 (ISO High Cube) RDC-IT 50/10-L-III RDC-IT 60/12-L-II RDC-AIO 60/6-M-II RDC-IT 90/8-M-II RDC-AIO 90/8-L-II RDC-AIO 180/16-L-II RDC-AIO 180/16-L-III 7250 x 3000 x 3000 7250 x 3000 x 3000 20 Modular data centres

Container for the uninterruptible power supply RDC-P 200/8-ISO S-II RDC-P 1000/8-M-II 2 parallel paths, 2 x 60 to 200 1) 2 parallel paths, 2 x 1 MW ABB DPA UPScale with batteries and low-voltage distributor Modular layout LCP DX cooling Separate connections for A and B supply lines. Both paths are completely separate, with redundant UPS modules, batteries and the corresponding low-voltage power distributor. ABB DPA 500 with batteries and low-voltage distributor Modular layout (500 kw modules) LCP CW cooling Batteries separate Separate connections for A and B supply lines. Both paths are completely separate, with redundant UPS modules, connections for batteries and the corresponding low-voltage power distributor. Modules: n+1 Modules: n+1 RDC-IT (all variants) RDC-IT (all variants) 6058 (20 ft.) x 2438 x 2896 7250 x 3000 x 3000 Modular data centres 21

22 Modular data centres

IT as a service simple, and from any location Rittal and Innovo Cloud have joined forces in a strategic partnership to market innovative infrastructure and cloud solutions based on the flexible IT as a service model (ITaaS). Customers get a turnkey cloud data centre in which components such as racks, climate control and power supply are available as predefined modules. The scope of supply optionally includes the IT components (such as server, network and storage). In addition, the established open source OpenStack framework is used as the cloud management software. The result is a standardised, virtual private cloud data centre (BCC Balanced Cloud Center), which is equally well-suited to standard applications in the ITaaS mode as to highly demanding application scenarios, such as high-performance computing (HPC), SAP Hana or Big Data applications. Depending on the customer solution, these innovative ITaaS models may be implemented on matching, previously presented container modules. For example, the BCC concept (RDCS 200-L-II-B) features in the Lefdal Mine Datacenter project currently being installed on the west coast of Norway. The five-storey tunnel system with 75 chambers provides 120,000 square metres of space for an infrastructure with a potential total capacity of 200 MW. The project partners have set themselves the ambitious target of making the LMD the number one in Europe, with unsurpassed levels of cost-efficiency, security, flexibility and sustainability. When the Total Costs of Ownership (TCO) are taken into account, what is more, the LMD is 40 percent cheaper than other data centres in Europe. This is due in large part to the cooling solution, which cools waste air from the servers via highperformance heat exchangers with a cooling circuit linked to the seawater. The entire system is connected to the 565 metre deep fjord, which guarantees unlimited supplies of cold water and reduces energy consumption to a minimum. Modular data centres 23

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services You can fi nd the contact details of all Rittal companies throughout the world here. XWW00126EN1708 www.rittal.com/contact