GILTRAP GENERATION II RF CONTROL SYSTEM

Similar documents
GETTING STARTED... 2 GENERAL SETUP INSTRUCTIONS...2

DEFAULT SCREEN. Button and Screen Layout DRILLING WIDTH TARGET RATE HOPPER NUMBER CROP NAME DRILLING ACTION CROP NUMBER. HOPPER selection POWER On/Off

Installation & Calibration Manual

Rexroth Controller Installation & Operations Manual

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual

ivisibility (Keypad Operator Access Control Series) Lift Truck Onboard Automatic Detection / Recording of All Operational Downtime Events

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

DirectCommand Installation RoGator Model Year Ag Leader Technology

IPM500 Series QuickStart Manual

DirectCommand Installation 5 Channel Spreader Control Module Technology

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

Mounting DIGITAL DISPLAY

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

Basketball Shot Clock Set LX2180 Manual

Tile Plow Installation O Connell

Quick Draw Electronics. Shooting Sports Timer User Manual. Model CLUB All In One

IPM650 Intelligent Panel-Mount Display

CHAPTER 3B: ELECTRONIC POWER STEERING

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Installation & Calibration Manual

Tile Plow Installation Gold Digger

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Cab Box Kit Dome Plug Cab Box Cab Box Lid

Model 500 Digital Weight Indicator

Stock Weigh 300. Operators Manual HELLO. Ft. Atkinson, Wisconsin USA. Panningen, The Netherlands

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations

PS-IN202 Weighing Indicator User Manual

Sidewinder Pumps Inc. AC Timer/Controller

GT 400 Operators Manual

DISCLAIMER Whilst every effort has been made

Table of Contents. Part I USB Communication. Part II User Interface. Part III User Settings (Tab Control) DFS-1000 Dataview. 2 File Menu.

Truckweigh. operators sheet STGGLOBAL.NET

Environdata FA ma Converter Guide

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

DPM-3221 Digital DC Power Meter with data logging capability.

Operator s Manual. Morbark Integrated Control System Woodhog Series Model 2600

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

Installation & Calibration Manual

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

DirectCommand Installation DirectCommand Complete Wiring Harness

Tactical Weather Station Set-Up Guide 1

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Validator Update Instructions for Rowe BC1200 $1 - $20

Installation Instructions

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

Wi-Card Skeet-Trap Claymate Operator and User Manual

CONTENTS SETTING THE TIMERS AND LAP TIMER...18

SCALE LINK - SL2 Technical Manual

Instruction Manual CTC-1

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

ELECTRO-MECH SCOREBOARD CO.

INSTALLATION & OPERATION ENGINEERS FOR THE EMERGENCY WARNING INDUSTRY

R147 WIRELESS ANTI-TWO-BLOCK INDICATOR

Part Name/Description Part Number Quantity

TSMIU Wireless Bridge Installation and Configuration

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

Note: Indented items indicate parts included in an assembly listed above

Part Name/Description Part Number Quantity

Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System

GEN 6 LOCKPICK INSTALLATION OPTIONS COPYRIGHT 2010 COASTAL ELECTRONIC TECHNOLOGIES, INC.

Adapter Kit - Remote QSI Electronics Installation Instructions

Procedure to Replace a TCD DPM with an IS TCD DPM in a Maxum or Maxum II Analyzer

EVERSAN. MODEL 9658 EVERSAN PERIOD INDOOR/OUTDOOR MULTI-FUNCTION SCOREBOARD. Instruction Manual

Calibration & Connectivity

IRF90 - Rotating Focuser

TALS 2. Torque Activated Logging System. Operating Instructions

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

Features: Contents: If you are missing any of the above components please contact Racepak at

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Megatouch FORCE Monitor Chassis Board Replacement

! User Manual Rev. 1

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

FLOE WIRELESS REMOTE ASSEMBLY INSTRUCTIONS KIT P/N

Silent Sentinel Solar Powered Advanced Warning Vehicle Mounted. Arrow Panels. Installation, Operation and Maintenance Manual (P/N )

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

CODE 50108, 50110, 50164, 50165

Components. Tools for Setup. Installation Outline

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

EPS 06 in rear housing type A1

InSight Single Implement

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

Operating Instructions

Click Save to return to the main Setup screen.

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

DirectCommand Installation RoGator 864/874/1064/1074 (MY 2006 & Earlier) Ag Leader Technology

II. Programming and Adjustments

Installing Keypad and Backplate

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

Abstract. GLV User Manual 1

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

Transcription:

GILTRAP GENERATION II RF CONTROL SYSTEM February 2008 Introduction... 2 Control Mode Options... 2 Remote Display Layout... 3 Controller Layout... 3 Operation Section...4 Overview... 4 Valve Over-ride Function... 4 REMOTE DISPLAY SCREENS... 5 Screen Symbols... 5 Start-up Screen... 5 Standard Mode Screen... 6 Weight Mode Screen... 7 Distance Mode Screen... 8 Speed Mode Screen... 9 Scales Screen... 10 Installation Section...11 Component Layout... 11 Remote Display Mounting & Power Supply... 12 Forage Wagon Controller & Power Supply... 12 Setting the RFID Number... 14 Fitting the Power Module Circuit Board... 15 Fitting the Wheel Sensor... 15 Fitting the Load Cells... 16 Setting System Parameters... 17 Checking Setup Parameters... 21 Factory Parameter Settings... 22 Final Check... 23

2 Introduction The Giltrap Generation II RF Control System consists of a Controller that is mounted on the wagon that uses wireless technology to relay data such as feed rate, load weights or feedout amounts (depending on options purchased) from the wagon and displays it on the Remote Display mounted near the operator on the tractor, allowing the operator to control the feed rate using different modes. Powerfully capable, yet simple to use, the controller has large buttons and an easy-to-read display allowing the operator to constantly monitor, and adjust the feed rate when needed, all while on the move. Control Mode Options The system has a total of five different operation modes available. The availability of these are dependant on the hardware options fitted to the machine. Hardware available: Load cells for weight readings Solenoid coil for floor control Wheel sensor for ground speed calculation Standard Mode The operator controls the feed rate through a percentage range from 0 to 100%. Requires a solenoid coil to be fitted. Weight Mode The operator can enter a target weight to feed. The feed rate control is the same as Standard mode. Requires load cells and solenoid coil to be fitted. Distance Mode (also known as Fully Automatic mode) The wagon will unload the required amount over the required distance, and will compensate for changes in ground speed. Requires load cells, solenoid coil and wheel sensor to be fitted. Speed Mode The operator controls the feed out rate through a percentage range from 0 to 100% and the feed rate is automatically adjusted according to ground speed. Requires a solenoid coil and wheel sensor to be fitted. Load cells are optional. Scales Mode Only has a weight display. Requires load cells to be fitted. Floor rate is controlled manually.

3 Remote Display Layout Display screen UP button Power switch GO button TARE/GROSS button STOP button LEFT button ZERO button RIGHT button MODE button DOWN button Power plug Controller Layout Power ON button Power OFF button Power light Signal light Signal light Valve light Weight connection Valve connection Power connection

4 Operation Section Overview Assuming installation (page 11 23) has been completed, the power for the system is controlled by the switch adjacent to the Remote Display. 1. Turn the switch on to provide power to the Remote Display and the wagon. 2. If the wagon is disconnected, press and hold the ON button on the Controller for one second. The Controller is now operating on its own battery. 3. Begin loading the wagon. See more detailed information regarding modes and buttons. 4. Once completed loading, connect the wagon to the tractor and connect the 7-pin plug. 5. Once ready to feed, select the appropriate mode and press GO button. You are now ready to proceed. Note: The Controller power light will illuminate when the ON button is pressed or the wagon is plugged into the tractor. To turn off, the wagon must be un-plugged before pressing the OFF button. Valve Over-ride Function When a solenoid is fitted for floor control, a manual over-ride function will also be provided. Note: This function over-rides all RF floor rate control. Use ¼ - ½ turn adjustments per time. Do not over-adjust. For electronic operation with RF control, the screw adjuster must be unscrewed all the way out (anti-clockwise) and the locking ring tightened. IMPORTANT Manual over-ride located beneath this cover To operate in case of electronic malfunction, undo locking ring and screw in adjuster. Use ¼ - ½ turn adjustments. Locking ring Over-ride adjuster Label on cover

5 Remote Display Screens Screen Symbols Apart from usual text characters, the screen can display other symbols at various times. The battery symbol indicates when the system is operating on its own battery. The voltage display indicates the condition of the battery. The antenna symbol indicates when the Controller and Remote Display have communication between them. This must show at all times for successful operation. Start-up Screen When the Remote Display is powered up, the start-up screen is displayed for 3 seconds as below. After this the screen will change to the operating screen. GILTRAP GEN II CONTROL SYSTEM Remote Display RF channel Channel: 1 Rev 3.4 Remote Display software revision If the wagon is not connected i.e. not getting power from the tractor, the controller will not start. The screen below will display until communication has begun by plugging in the wagon or pressing and holding the GO button on the controller for 1 or more seconds. After establishing communication, it will proceed directly to the next screen. Waiting for RF Forage Wagon Communications... Once communication has begun between the devices, a screen similar to the one below will show. FEED RATE: 50% DISPENSED: 0kg GROSS: 2950kg STOP Std 12.5V The modes that are available are dependant on the hardware options fitted to the machine.

6 Standard Mode Screen In standard mode, the feed rate is shown as a percentage. A range of 1-100% is available with 100% being maximum feed rate. This rate is shown on the top line of the screen. This mode is useful for general operation and is the most simple to use. Rate control only FEED RATE: 50% STOP Std Feed Rate System status Mode of operation Connectivity status Rate control with load cells fitted FEED RATE: 50% DISPENSED: 1050kg GROSS: 2950kg STOP Std 12.5V Dispensed amount Product amount in machine Battery voltage System battery indicator Screen Features: The top line shows the feed rate. The bottom line of the screen shows the status of the system (STOP), the mode of operation (Std) and connectivity status. Additional features that show if load cells are fitted: The second line will show the weight dispensed since GO was pressed. The third line will display the present wagon weight. This may be gross or tare. The bottom line of the screen shows the status of the system (STOP), the mode of operation (Std), the battery voltage (highest voltage available to the unit. When disconnected from the tractor, this will be the internal battery voltage), and connectivity status. Operating Notes: The operator can adjust the rate percentage figure by pressing UP or DOWN on the keypad. The operator can select between gross and tare weight to be displayed by pressing TARE/GROSS on the keypad. The operator can zero only the dispensed weight by pressing GO on the keypad. The operator can start and stop the feed-out by pressing GO and STOP on the keypad. The operator can switch to other available operating modes by pressing MODE on the keypad. Screen Warnings: The operator can zero the gross and dispensed weight by pressing ZERO on the keypad. WAGON POWER NOT CONNECTED will flash on the display if the GO button on the Remote Display is pressed without the wagon being plugged into the tractor and/or power not getting from the tractor to the Controller.

7 Weight Mode Screen In Weight mode, the feed rate is shown as a percentage. A range of 1-100% is available with 100% being maximum feed rate. This rate is shown on the top line of the screen. The operator can enter a target weight to feed before a beeper will sound, the wagon floor will stop moving and the system status will return to STOP. Mode of operation System status System battery indicator FEED RATE: 50% TO FEED: 560kg GROSS: 2950kg STOP Weight 12.5V Feed Rate Target weight to feed Product weight in machine Connectivity status Battery voltage Screen Features: The top line shows the feed-out rate. The second line shows the weight to feed out before a beeper sounds. The third line shows the weight of the current load. This may be gross or tare. The bottom line of the screen shows the status of the system (STOP), the mode of operation (Weight), the battery voltage (highest voltage available to the unit. When disconnected from the tractor, this will be the internal battery voltage), and connectivity status. Operating Notes: The operator can alter the feed-out rate by adjusting the rate percentage by pressing UP or DOWN on the keypad. The operator can adjust the weight to be dispensed by adjusting the TO FEED figure. This is done by pressing UP or DOWN on the keypad when the TO FEED figure is underlined. Use the RIGHT or LEFT button to move the underline cursor. The operator can start and stop the feed-out by pressing GO and STOP on the keypad. The operator can switch to other available operating modes by pressing MODE on the keypad. The operator can select between gross and tare weight to be displayed by pressing TARE/GROSS on the keypad. The operator can zero the gross and dispensed weight by pressing ZERO on the keypad. Screen Warnings: WAGON POWER NOT CONNECTED will flash on the display if the GO button on the Remote Display is pressed without the wagon being plugged into the tractor and/or power not getting from the tractor to the Controller.

8 Distance Mode Screen In Distance mode, the feed rate is automatically set by dispensing feed over a set distance. Mode of operation System status Screen Features: The top line shows the weight to feed out. TO FEED: 1800kg LENGTH: 100m GROSS: 2950kg STOP Dist 12.5V Feed to dispense Distance to travel Product weight in machine Connectivity status Battery voltage System battery indicator The second line shows the distance over which to feed this weight. The third line shows the present wagon weight. This may be gross or tare. The bottom line of the screen shows the status of the system (STOP), the mode of operation (Dist), the battery voltage (highest voltage available to the unit. When disconnected from the tractor, this will be the internal battery voltage), and connectivity status. Operating Notes: The operator can adjust the weight to be dispensed by adjusting the TO FEED figure. This is done by pressing UP or DOWN on the keypad when the TO FEED figure is underlined. Use the RIGHT or LEFT button to move the underline cursor. The operator can adjust the distance to feed the weight over by adjusting the LENGTH figure. This is done by pressing UP or DOWN on the keypad when the LENGTH figure is underlined. Use the RIGHT or LEFT button to move the underline cursor. The operator can start or stop the operation by pressing GO or STOP on the keypad. If the feed bins are unequal in length, enter the total length of the bins in the LENGTH figure and the total amount to feed in the TO FEED figure. After travelling the first bin, press STOP on the keypad. The display will change from RUN to WAIT. You can then travel forward or backward without the distance changing. Press GO to continue or press and hold the STOP button for 3 or more seconds to reset the system status to STOP. The system will automatically return to STOP mode after counting down the distance to zero. The operator can switch to other available operating modes by pressing MODE on the keypad. The operator can select between gross and tare weight to be displayed by pressing TARE/GROSS on the keypad. The operator can zero the gross and dispensed weight by pressing ZERO on the keypad. Screen Warnings: WAGON POWER NOT CONNECTED will flash on the display if the GO button on the Remote Display is pressed without the wagon being plugged into the tractor and/or power not getting from the tractor to the Controller. INCREASE GROUND SPEED will flash on the display when the wagon is travelling too slow and causing the machine to overfeed. Note that ground speed needs to increase not tractor revs. DECREASE GROUND SPEED will flash on the display when the wagon is travelling faster than the machine can feed. Note that ground speed needs to decrease not tractor revs.

9 Speed Mode Screen In Speed mode, the machine will maintain a consistent feed-rate relative to ground speed. The feed rate percentage is adjustable from 1 100%. Rate control only FEED RATE: 50% STOP Speed Feed Rate System status Mode of operation Connectivity status Rate control with load cells fitted FEED RATE: 50% DISPENSED: 940kg GROSS: 3540kg STOP Speed 12.5V Dispensed amount Product weight in machine Battery voltage System battery indicator Screen Features: The top line shows the feed rate. The bottom line of the screen shows the status of the system (STOP), the mode of operation (Speed) and connectivity status. Additional features that show if load cells are fitted: The second line shows the weight fed out since the wagon was loaded. The third line shows the present wagon weight. This may be gross or tare. The bottom line of the screen shows the status of the system (STOP), the mode of operation (Speed), the battery voltage (highest voltage available to the unit. When disconnected from the tractor, this will be the internal battery voltage), and connectivity status. Operating Notes: The operator can alter the feed-out rate by adjusting the rate percentage by pressing UP or DOWN on the keypad. The operator can adjust the weight to be dispensed by adjusting the TO FEED figure. This is done by pressing UP or DOWN on the keypad when the TO FEED figure is underlined. Use the RIGHT or LEFT button to move the underline cursor. The operator can start or stop the feed-out by pressing GO or STOP on the keypad. The operator can zero only the dispensed weight by pressing GO on the keypad. The operator can switch to other available operating modes by pressing MODE on the keypad. The operator can select between gross and tare weight to be displayed by pressing TARE/GROSS on the keypad. The operator can zero the gross and dispensed weight by pressing ZERO on the keypad. Screen Warnings: WAGON POWER NOT CONNECTED will display if the GO button on the Remote Display is pressed without the wagon being plugged into the tractor and/or power not getting from the tractor to the Controller.

10 Scales Screen In Scales mode, the screen will only display weight figures. This mode is used when no rate control is fitted to the wagon. No other modes are available if only load cells are fitted. The operator can enter a target weight to feed when a beeper will sound, the wagon floor will stop moving (if the floor control solenoid is fitted) and the system status will return to STOP. Mode of operation TO FEED: DISPENSED: GROSS: STOP Scales 560kg 733kg 3440kg System status 12.5V Target weight to feed Dispensed amount Amount in machine Connectivity status Battery voltage System battery indicator Features: The top line shows the weight to feed out before a beeper sounds. The second line shows the weight dispensed since GO was pressed. The third line shows the tare or gross weight in the machine. The bottom line of the screen shows the mode of operation (Scales), the battery voltage (highest voltage available to the unit. When disconnected from the tractor, this will be the internal battery voltage), and connectivity status. Operating Notes: The operator can adjust the weight to be dispensed by adjusting the TO FEED figure. This is done by pressing UP or DOWN on the keypad when the TO FEED figure is underlined. Use the RIGHT or LEFT button to move the underline cursor. The operator can select between gross and tare weight to be displayed by pressing TARE/GROSS on the keypad. The operator can zero only the dispensed weight by pressing GO on the keypad. To allow the dispensed weight to accumulate and the target feed weight to work, the operator must press GO before commencing feeding. The operator can zero the gross weight and dispensed weight by pressing ZERO on the keypad. Screen Warnings: None

11 Installation Section Component Layout Remote display #TCS-V2DISP 12 24VDC Supply [Tractor battery preferably] Brown - Positive Blue - Negative 5A Fuse Install loom #TCS-LOOM1 (with box) Install loom #TCS-LOOM1V2 (no box) Cab switch Cable from battery to switch (5m) Cable from switch to tractor plug (2m) Remote display cable #TCS CABLE #LIGHTLED-LH #LIGHTLED-RH Tail lights Wheel sensor (5m) #TCS-OEM-PROX Power module #TCS-V2PB Weight module #TCS-V2WGTMOD Load cells (4 or 6) #ES-WLY00003P Battery cable (0.55m) #TCS-V2CABBAT 5A Fuse Battery #TCS-BATTERY2 Data cable (1m) #TCS-V2CABWGT Controller #TCS-V2CONTR Controller power cable (1m) #TCS-V2CABCON 7 core cable (5.5m) with plug #TCS-LOOM2 7 pin plug #PLUG7PINM Valve cable #TCS-V2CABVAL Valve assembly #HYSUPERVC-DPBM

12 Remote Display Mounting & Power Supply The Remote Display is designed to be mounted in the tractor cab and be easily accessible to the driver. It contains a radio frequency (RF) communication device to control the Forage Wagon Controller (Controller). It will require shielding from the weather elements of sun and rain etc. The Remote Display requires 12-24 volts DC to operate. It will typically only draw 0.2A. The power supply will originate from the tractor battery as part of the installation loom (supplied with the machine). Forage Wagon Controller & Power Supply The Forage Wagon Controller is powered from the tractor while operating. When disconnected from the tractor, it draws power from its own sealed lead acid battery. No installation wiring is required on the Forage Wagon. The tractor requires an installation loom (supplied) which provides a switched and fused positive and negative supply from the tractor battery to the rear 7-pin socket. The tractor battery is the best power supply point as it provides the most stable and quiet power source. RF positive supply from wiring loom (BROWN) RF negative supply from wiring loom (BLUE) Note: If pin 5 is already used, connect the blue wire into pin 3 and do the same with the trailer plug. There are three CPC connectors on the Controller. If a connector is not used, place the sealing cap over it.

13 Mounting the Modules Modules should be mounted as illustrated. Power wires should be kept separate where possible from the load cell cables. Only 2 screws are required at opposite corners of each module. Keep all cables clear of moving parts. Control Module Control Module mounting bracket Battery Weight Module Power Module Battery base plate Run power cables this side Run load cell cables this side

14 Setting the RFID Number The RFID Number setup screen is used to assign a wireless address to the Controller. This feature is available to prevent interference between two systems when they are operated in close proximity to each other. To access the Remote Display RFID screen, re-power the display and press and hold the MODE button until a setup screen appears. RFID Number 1.00 The operator can press the UP button or the DOWN button to adjust this value. Press GO to enter then STOP to escape. Re-power the Remote Display to access the new channel. Controller Settings After removing the Controller cover, a DIP switch with 8 white switches is visible. DIP switches The D.I.P. (dual inline plastic) switches which are labelled 1 to 8 are used to select the RF channel ID. The switch is considered to be on when switched to the right hand side. The channel ID of the Controller MUST match the software setting of the Remote Display. If the channel ID is changed in either the Remote Display or Controller then you must re-power both devices for the new setting to take effect. To re-power the Controller, unplug the POWER cable for 5 seconds. The DIP switch settings are shown in the following table. RFID # 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 1 3 1 2 1 4 1 1 1 3 1 2 Switch 2 3 3 2 4 2 2 4 3 3 On 3 4 4 4 None

15 Fitting the Power Module Circuit Board The power board will need to be fitted if load cells are fitted. It is fitted into the power module. Open the Power Module lid. Remove the wire joining block. Fit the circuit board with the supplied screws. Attach the wires as noted on the board. Fitting the Wheel Sensor The wheel (proximity) sensor has to be adjusted halfway between the range of being always on and always off. This is approximately 5mm between the end of the sensor and the wheel plate. Take care when running the cable that there is enough slack to allow the axle to fully oscillate. Approx. 5mm

16 Fitting the Load Cells Fit the studs to the load cell first before fitting the load cells to the machine using the bolts provided. Lower the top half of the wagon onto the studs. Tighten the top nut then back off ½ turn. Route the wiring through the pipe/brackets provided through to the junction box taking care to keep the wiring tidy and away from moving objects. Concave washer Convex washer Load cell Stud and nut Recommended Load Cell Bolt Torque Settings M20-280 ft/lbs or 380Nm M24-490 ft/lbs or 660Nm Note: If installing PT brand load cells, there will be two extra blue and brown wires. Connect the Sense +ve (brown) together with Excitation +ve (red) and Sense ve (blue) together with Excitation ve (black). Weight Module Connection When fitting load cells or a wheel sensor, see below for fitting information about connecting wires into the weight module. Insert screw driver for top layer here Top layer Insert screw driver for bottom layer here Bottom layer

17 Setting System Parameters Parameters are required to be set for the machine to function correctly. Entering Configuration Screens To enter set-up, press TARE/GROSS and ZERO together for 4 seconds or until the set-up screen appears. Press UP or DOWN to adjust the parameter. Press MODE to move to the next configuration screen. It will save what is displayed on the screen. Press STOP to exit the configuration screens. Scale Damping Value The Scale Damping Value parameter is a weighting value over which the weight is averaged. A higher value will display a smoother weight display but won t react to weight changes as quickly. Scale Damping Value 1.00 RANGE: 1-15 Load Cell Type The Load Cell Type parameter specifies the maximum load for each individual load cell used on the wagon. Load Cell Type 5000.00kg RANGE: 5000-10000 Number of Load Cells The Number of Load Cells parameter specifies the total amount of load cells fitted to the machine. Enter 0 if no load cells are fitted. Number of Load Cells 4.00 RANGE: 0-6 Load Cell Sensitivity The Load Cell Sens. parameter specifies sensitivity of the load cells used on the wagon. The setting is in mv per Volt. This means mv output per Volt of excitation. This is a characteristic of the load cells used. Load Cell Sens. 2.00mV/V RANGE: 0-10

18 Scale Hysteresis The Scale Hysteresis parameter specifies how much a weight reading needs to change before the reading on the screen will change. Scale Hysteresis 10.00kg RANGE: 1-200 Scale Increments The Scale Increments parameter specifies minimum scale increment displayed on the screen. Scale Increments 10.00kg RANGE: 1-200 Maximum Valve Pressure The Max Valve PSI parameter sets the elevator load sensing pressure. Reduce this value if the elevator stalls too often. Ideally this should be set approximately 200 300 PSI below tractor relief pressure. Max Valve PSI 2100.00psi RANGE: 0-3000 Wheel Sensor Fitted The Wheel Sensor Fitted parameter indicates if the wheel sensor is fitted or not and displays appropriate modes to suit. Wheel Sensor Fitted YES RANGE: 0-1 Wheel Diameter The Wheel Diameter parameter is used to calibrate the wheel size on the machine. value. Note: For accuracy, measure from the ground to the centre of the hub (and double) when the machine is half loaded. This will compensate for tyre pressure. Press MODE to continue. Wheel Diameter 760.00mm RANGE: 0-1400 Number of Wheel Holes The Number of Wheel Holes parameter is used to calibrate the distance measurement for the number of holes on the encoder disk used by the speed sensor. No. of Wheel Holes 15.00 RANGE: 0-50

19 Low Battery Level The "Low Batt Level" parameter defines the minimum battery voltage level at which the screen will switch from displaying voltage to displaying LOBAT. This function can be cancelled by setting the voltage to 0.00V. Low Batt Level 11.50V RANGE: 0-30 Solenoid Valve Fitted The Valve Fitted parameter indicates if the solenoid valve is fitted or not and displays appropriate modes to suit. Valve Fitted YES RANGE: 0-1 Minimum Valve Setting The "Min Valve Setting" parameter defines the minimum valve opening percentage when in Distance and Speed mode, while running. When stopped, the valve will go to 0. Min Valve Setting 30.00 RANGE: 0-100 Valve Ramp Up Time The Valve Ramp Up Time parameter changes the valve ramp up time. Valve Ramp Up Time 0.00sec RANGE: 0-10 Valve Ramp Down Time The Valve Ramp Down Time parameter changes the valve ramp down time. Valve Ramp Up Time 0.00sec RANGE: 0-10 Valve Start-up for Distance Setting The Valve Startup Dist. parameter is the initial valve setting to use when the machine is started in Distance mode. Valve Startup Dist. 85.00% RANGE: 0-100

20 Minimum Speed while in Speed Mode The "Speed Mode Min Speed" parameter is only used for Speed mode. It defines the minimum speed the machine must be moving before the machine begins to operate. This function is adjustable between 0 and 5 km/h, with increments of 0.1km/h. Speed Mode Min Speed 1.00km/h RANGE: 0-5 Maximum Speed while in Speed Mode The "Speed Mode Max Speed" parameter is only used while in Speed mode. It defines the theoretical maximum speed the machine will reach at which point the machine will be operating at maximum feed rate. The lower this is set, the more aggressive the machine will operate. This function is adjustable between 1 and 20 km/h with increments of 1km/h. Speed Mode Max Speed 10.00km/h RANGE: 1-20 Any speed over this parameter will cause the machine to run at the percentage setting on the display. Speed Mode Start-up Time The "Speed Mode Strt. Time" parameter is only used while in Speed mode. It defines the length of time the machine must be moving above the minimum speed before it begins its usual function. This function is adjustable between 1 and 20 seconds with increments of 1 second. Speed Mode Strt. Time 1.00sec RANGE: 0-20 Distance before Finish The "Dist. Before Finish" parameter is only used while in Distance mode. It defines the length before the end of the run at which the valve controller will return to zero hence stopping the floor operation and clearing the machine. When set on zero, the machine will continue functioning until the distance reads zero. This Dist. Before Finish 1.00m RANGE: 0-10 function is adjustable between 0 and 10 metres with increments of 0.5 m. Shut Down Timer The shut down timer controls the time that the Controller will stay powered up while running on battery power. Shut Down Timer 20.00min RANGE: 1-60

21 Checking Setup Parameters A Function screen is available to check current settings. To enter, press and hold the left arrow for three or more seconds. The top line shows the requested valve position. The second line shows the present gross load weight. The third line shows the current machine ground speed. The bottom line of the screen shows the current mode of operation (Std), the Controller software revision and connectivity status. The Function mode screen is shown below: Current operating mode VALVE: 38% GROSS: 2850kg SPEED: 5.65km/h MODE:Std Rev 3.5 Requested valve position Gross weight Ground speed Controller software revision By pressing the UP or DOWN buttons, you can scroll and view parameters. They cannot be changed here. Press GO or STOP to exit and return to the operating screen.

22 Factory Parameter Settings Software Revision: Remote Display 3.4, Controller 3.8 To enter set-up, press TARE/GROSS and ZERO together for 4 seconds or until the setup screen appears. Press MODE until the correct parameter is displayed. Press UP or DOWN to adjust the parameter. Press STOP to exit the configuration screens. Remove power from the Controller to update changes. Parameter Value Scale Damping Value 4.00 Load Cell Type 5000.00 kg Number Of Load Cells 4.00 Load Cell Sens. 2.00 mv/v (PT) or 2.20mV/V (Kelba) Scale Hysteresis 10.00 kg Scale Increments 10.00 kg Wheel Sensor Fitted Yes Wheel Diameter 760.00 mm No. of Wheel Holes 15.00 Low Batt Level 11.50 V Valve Fitted Yes Max Valve PSI 2250.00 psi Min Valve Setting 30.00 % Valve Ramp Up Time 0.00 sec Valve Ramp Down Time 0.00 sec Valve Startup Dist. 85.00 % Speed Mode Min Speed 1.00 km/h Speed Mode Max Speed 10.00 km/h Speed Mode Strt Time 1.00 sec Dist. Before Finish 1.00 m Shut Down Timer 20.00 min Note: These are factory default settings. Some machines will require different settings.

23 Final Check Check that the Controller is working correctly: Plug in the 7-pin plug into the tractor and turn on the power switch. This applies power to the Controller. The POWER LED on the Controller should be illuminated. Unplug the 7-pin tractor plug. A battery power symbol ( ) will show on the screen which indicates the system is running on battery power and the wagon is not plugged into the tractor. After disconnecting the 7 pin plug and waiting 20 minutes (depending on parameter setting), the Controller should power down. If tractor power is reapplied, the Controller will restart. Note: To force power off and preserve battery power, press and hold the OFF button on the Controller when tractor power is disconnected. Check that the Power module is working correctly: When the wagon is plugged in the tractor, voltage should be higher than when unplugged. Plugged in should read approx 13.9 14.5V. Unplugged should read approx 11.5 12.8V. Check that there is RF communication: There should be an antenna symbol ( ) displayed in the bottom right hand side of the screen. Check that the valve (if fitted) is working correctly: Change the mode to Std, increase the FEED RATE to 100% and press GO. The Controller LED will be illuminated when the valve reaches 100% setting and the valve solenoid will make a light buzzing noise. The wagon floor chain should start and stop when GO or STOP is pressed. System hydraulic pressure can sometimes cause the floor to not quite stop. In this case, increase tractor revs and recheck. Check that the load scales (if fitted) are weighing correctly: This can be done by applying a known load to the floor after zeroing. The Weight module LED labelled Weight should be illuminated whenever the system is running. If the weight display is unstable when stationary, charging the battery will help. The voltage will be displayed on the lower line of the screen. When the system is running on battery power, a ( ) symbol will display alongside the voltage reading. Check that the wheel sensor (if fitted) is working correctly: Jack up the wheel with the wheel sensor fitted and check that the sensor light blinks for each hole while the wheel rotates. The green LED labelled PROX in the weight module should also blink at the same time as the sensor light. In distance mode, dial up a distance of say 20 metres on the Remote Display and press GO. Rotate the wheel 2-3 revolutions (forward or reverse) and check that the distance is decreasing. All complete: Ship with battery connected (it will power down to preserve power).