YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.

Similar documents
Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

PDU - Overview / Non-Intelligent PDU s

Power Distribution Unit

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

Modular PDU Smart metering for your IT

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators

IT power distribution Power distribution units (PDU) Basic. Versions available:

PDU Solutions. PDU Solutions

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

Technical Manual Nova: Cabinet Security Management System (CSMS)

Excel Power Distribution

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

V2.42 Schleifenbauer PDU User manual

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring

WIRELESS ENVIRONMENTAL MONITORS

Specification Sheet: HT SERIES

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

POWER DISTRIBUTION UNITS

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 400V

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Switched, Outlet Level Monitoring

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

New Product Release. Integrated Intelligent Power Distribution.

ECO PDU Power Distribution Unit

PDU Inspired by Your Data Center. W IEC PDU Series

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

User Manual. Per Port Monitoring Models

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Stripes. 19" Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS...

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Power Distribution. For technical support call Online catalog available at leviton.com 461

English IT power distribution Professional power supply concepts

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Features: Example of use

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Frequently Asked Questions

LED Controls. Lighting Controls. LED Controls

ECO PDU PE7108/PE7208

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Engineering and Manufacturing Excellence in Data Centre Infrastructure

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

ECO PDU PE5108/PE5208

Energy Web Server. Viale Borri 231, Varese - Italy. Cat. no: PM1WS255

- Ovens - Food processing - Dryers, etc.

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

- Ovens - Food processing - Dryers, etc.


8-Outlet eco PDU PE6208AV

SECTION SWITCHBOARDS

Hoist Controller for Low Voltage Hoist Instruction Manual

Hardwired Uninterruptible Power Supply

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Model Number Structure

ipdu Pocket Guide INTERNATIONAL

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

HMIPWC7D0E01 Panel PC Optimum - Compact Flash - 15'' - DC - Fanless

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

The -3Ph extension on a product indicates a 3 Phase power product.

Control Panel CP600 CP635-FB, CP635-FW

Proximity sensors SME-8, for T-slot Technical data Magnetic reed

Model Number Structure

SITOP in the SIMATIC Design

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

ipdu Pocket Guide NORTH AMERICA

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Linear Luminaire with LED Series 6012/5

24/48V Battery Bank Ah High Cycling Long Life

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

XBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

Summit Virtual Chassis Design and Installation Guide

HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

ECO PDU. Features. PE5220sA

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

AC-DC Converter REC /60-K20

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

UPS Series. features: uninterruptible power supply. what great systems are built on.

Room Temperature Controller

Smart Monitoring System compact, secure, efficient

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

Managed Rack PDU MPH2 More efficient Simpler Better

Transcription:

This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.

Your PDU 3..7 1. 2. Our advanced technology offers you accurate measurements and detailed data, so that you can make the right choices..6.6.5 6. 6. 4. 5. Our PDUs are of the highest quality which means we can guarantee you the safest possible solution for the infra environment of your datacentre..4.3 7..2.1 Discover the elements of YourPDU configure YourPDU 2

Your PDU YourPDU infra 1. cable/cable entry 2. fuses/ Surge protection 3. housing 4. Outputs 5. Mounting.4.3 7. Content.2.1 YourPDU data 4 5 6 7 8 6. Residual current monitoring 7. Measurement 8. Display 9. Outputs 1o. sensors 9 10 11 12 13 Technical specifications 14 configure YourPDU 3

1. Cable/Cable entry Your PDU comes with a connecting lead of the correct length and with the correct connector. Furthermore, the cable connection is provided in the place that you need. The cable, which has been specially manufactured for Schleifenbauer, has LSZH specification and is ultra-flexible. It has an oversized diameter which results in lower build-up of heat and lower energy consumption. In addition to the standard connection with a connector, there is also the option of a terminal connection. Cable Length can be adapted Choice of connector type IEC320 C14 & C20 connector which can be supplied with an optional lock Low Smoke Zero Halogen (LSZH) Oversized diameter Optional terminal connection Cable connection Choose where cable entry is located top base front rear connectors: 01 02 03 04 05 06 07 08 09 Options 01. CEE 7/4 (Schuko) CEE 7/5 (UTE) 02. IEC320 C14 03. IEC320 C20 04. IEC60309 1 phase (IP44/IP67) 05. IEC60309 3 phase (IP44/IP67) 06. BS 1363 07. GST 3/18 08. T13 09. T23 10. Cable connection 11. Terminal connection connections: 10 11 4

2. Fuses/Surge protection Nowadays, it is unthinkable to have a datacentre without the highest possible safety protection. It is even a legal requirement to use fuses in certain situations. You can employ fuses in YourPDU according to your requirements and the infrastructure. This guarantees continuity and reduces the chance of a power outage. Fuses Unrestricted choice of the type of fuse, including: Miniature circuit breaker (MCB) Thermal fuse Glass cartridge fuse holder PASCO cartridge holder surge protection Protects PDU against surges Hot swap Can be replaced by a data centre engineer Options 01. Glass cartridge fuse holder 02. Thermal fuse 03. Miniature Circuit Breaker (MCB) 04. Surge Protection 5

3. housing The housing of your PDU is made entirely from aluminium, due to its good thermal properties and so as to keep the weight low. You can determine the length and orientation (horizontal or vertical). Our aluminium housing can be supplied in various colours and is provided with custom engraving. Materiaal: 1.5 mm anodised aluminium Dimensions: Lengte: can be adapted Width: 65 mm Depth: 52,6 mm Adaptable orientation Kleuren: Black Green Orange Blue Red Yellow Custom engraving Options 01. Black* 05. Red* 02. Green* 06. Yellow* 03. Orange* 07. Custom engraving 04. Blue* * The colours shown are for illustration purposes. Actual colours may vary. 07 6

4. Outputs You can fit your PDU with various outputs and types of outputs. You configure both the number and type of outputs. For example, IEC C13, IEC C19 and CEE 7/4 (Schuko). You can specify the order in which you want the outputs to be arranged. IEC C13 and IEC C19 connectors are available optionally with a lock. 01 02 03 04 05 06 07 08 Various types of outputs: IEC320 C13 IEC320 C13 IEC-lock IEC320 C19 IEC320 C19 IEC-lock CEE 7/4 (Schuko) CEE 7/5 (UTE) IEC60309 1 phase (IP44/IP67) IEC60309 3 phase (IP44/IP67) BS 1363 GST 18/3 T13 T23 09 10 11 12 Options 01. IEC320 C13 02. IEC320 C13 IEC-lock 03. IEC320 C19 04. IEC320 C19 IEC-lock 05. CEE 7/4 (Schuko) 06. CEE 7/5 (UTE) 07. IEC60309 1 phase (IP44/IP67) 08. IEC60309 3 phase (IP44/IP67) 09. BS 1363 10. GST 18/3 11. T13 12. T23 7

5. Mounting In order to correctly install a PDU in a server rack, you need specific expertise. Schleifenbauer has expertise in house and offers mounting options for every type of server cabinet, whatever the type or manufacturer, using mounting brackets or even toolless mounting. What is your ideal mounting? If a standard mounting solution is not available, we can provide you with a custom solution! Independent of server rack manufacturer Independent of type of server rack Toolless mount option Option for custom mounting Options 01. Horizontal 19 inches 02. Toolless mount 03. Table mount 04. Recessed 05. Profile clamps 8

6. Residual current monitoring The residual current monitoring meter developed by Shleifenbauer enables you to easily localise leakage flows at circuit level. In various European countries, residual current monitoring can be used to meet statutory safety requirements. Class B measurement (measurement of AC and DC components) Auto-test Single and three-phase application N Optimum value = 0 L1 01. Residual Current Sensor 02. Schematic diagram of residual current monitoring 9

7. Measurement Manage your PDU remotely The measurement readings on your PDU provide insights into energy flows and enable you to manage these. You can read measurements locally or at a distance (remote). Naturally, you can also choose a PDU without measurement reading (basic). Select your configuration: Select your configuration: a. No measurement reading (basic) b. Local measurement reading (local) Current in A c. Measurement at a distance (remote) Current in A Power in W and VA Energy in kwh Voltage in V Power factor Web interface Our web interface is intuitive. It clearly shows all information and settings can be easily changed. Your data is comprehensive and clear Your PDU data is integrated into your environment using open standards. Communication via various protocols such as SNMP (v1, v2c and v3), Modbus and API. Our applications are developed in well-known DCIM platforms such as PerfIT, Schneider InfraStruxure Manager, Sunbird DCIM and itracs. Options 01. Local 02. Remote Options 01. Web interface 02. DCIM platform of PerfIT 10

8. Display If you choose remote measurement, the LCD display with LED backlight will provide you with all of the most important information. For instance, measurements status and configuration. The information is displayed horizontally or vertically, depending on your configurations. If a threshold value you have set is exceeded, this will be indicated on the display with an alert. LCD-backlight Horizontal/vertical display 11

Your PDU Energy measurement Total PDU Groups Individual outputs.6.4 The intelligence in YourPDU does not need to be limited to complete measurement. You can choose to individually measure the outputs or to activate/deactivate them. You can also combine both options..5.3 7. 9. Outputs (data) I ndividual outputs switchable at a distance bi-stable relays are used for this. configure YourPDU 12

10. Sensors Your PDU can be fitted optionally with external sensors. Schleifenbauer supplies a combined temperature/humidity sensor. It is also possible to add further sensors such as a water leak sensor based on binary input for potential-free contact. Temperature measurement Humidity measurement Dry switch contact (based on binary input for potentialfree contact) Temperature/humidity sensor 13

Technical information: examples of connectivity: Profile dimensions BxD 65 mm x 52.5 mm, adaptable length, anodised aluminium with stainless steel side plates Profile colours Black, green, orange, blue, red, yellow Power input 230/400 VAC single phase or three phase 16A/32A/63A Mains lead Single phase 16 A: 3G2.5, three phase 16A: 5G2.5, single phase 32A: 3G2.5, three phase 32A: 5G6 Low Smoke Zero Halogen (LSZH) Local measurement True RMS power (A) LCD display (3 digits) Remote measurement Energy total (kwh) no-resettable, sub-total (kwh) can be reset by user True RMS current (A) with peak registration. Peak duration can be defined Voltage (V) with dip registration or apparent power (VA), real power (W), power factor (%) Accuracy <1% (IEC 50470:3 Class C) Display LCD Backlight, 360-degree reading, tiltable Data bus 2 x RJ45 data bus connectors RS-485 Ethernet RJ 45 screened connector TCP/IP 10/100 Mb, DHCP with fall-back static IP, SNMP, Modbus, API Sensor port Digital temperature/relative humidity sensor and/or dry contact based on binary input for potential-free contact Energy consumption Electronic components: < 3 W Environment Ambient temperature: 0 C - 60 C Plug CEE 7/4 (Schuko), CEE 7/5 (UTE), IEC320 C14, IEC320 C20, IEC60309 1 phase (IP44/IP67), IEC60309 3 phase (IP44/IP67), BS 1363, GST 3/18, T13, T23 Outputs IEC320 C13, IEC320 C13 IEC lock, IEC320 C19, IEC320 C19 IEC lock, CEE 7/4 (Schuko), CEE 7/5 (UTE), IEC60309 1 phase (IP44/IP67), IEC60309 3 phase (IP44/IP67), BS 1363, GST 18/3, T13, T23 Fuses Miniature circuit breaker (MCB), thermal fuse, glass cartridge fuse holder, PASCO cartridge holder Surge protection Manufacturer: Dehn. Exchangeable module (Hot Swap) Certificates CE ROHS2 EN-60950 EN-61000 Bridge Ethernet Ethernet Data bus Hybrid 14

Contact Schleifenbauer BV Rietwaard 15 5236 WC s-hertogenbosch The Netherlands t 31 (0)73 52 30256 f 31 (0)73 521 23 83 Schleifenbauer Deutschland GmbH Industriering Ost 66 47906 Kempen Nordrhein-Westfalen t 49 (0)89 416 107 150 f 49 (0)89 416 107 159 www.schleifenbauer.eu