Fail-Safe-Function with Positioner NR-C1

Similar documents
Fail-Safe-Function with Positioner NR-C1

Option Fail-Safe-Accu NRGS1-24VDC incl. positioner

Position Controller RGS3-24VDC

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Solid State Remote Power Controller E /627

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

HERCULES-5000 INSTRUCTION MANUAL

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

H2C Motor Timers will be Discontinued March 2013; Replace with H3CR-A8E Solid-state Timer

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

EZ-24 EZ-24-HTB EZ-24-HTBS. Version May Publication PR-1100

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

AD-7830 Servo Amplifier

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

VA-7700 Series. Electric Valve Actuators. Product Bulletin

SCHMIDT Programming Tool SS 20.4xx Instructions for Use

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

Operating Instructions

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical Rotary Drive

Quick installation guide

Operating instructions

Geräte-Handbuch Device manual Notice pour utilisateurs

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Connections, displays and operating elements. Hand 1 / / 4

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Control instruments GUARDIAN 2 - GUARDIAN 3

Product and functional description

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS

FREQUENCY CONVERTER FC101 (QUICK GUIDE)

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

User Manual of 3M583

User s Manual. Extremely Low Noise 3-phase Microstepping Driver. For 3L583M. Version All Rights Reserved

Operating instructions. Speed monitor D / / 2014

Fuse or circuit breaker rating (A) Voltage range (V)

********SERVICE MANUAL******** MODELS:

SK TU4-IOE-M12-C Part Number

Control board for electromechanical gearmotors HERMES

MANUAL PLC1.01 BOARD

TECHNICAL MANUAL. Man / Auto. Ten Off / On x100 psi Tension lb X1000 lb 0.

ASI Systems ML5740A Series

ASI Systems ML5720A Series

Ocean Controls KTA-224 Modbus IO Module

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

Installation, Operation and Maintenance Manual

Manual pressure sensors DW35311x DW36311x

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

Unipower HPL600. Unipower HPL600

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.

Tap Manager TM100. Operating Instructions

Proportional Control Unit (PCU)

PD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06

PowerFlex 400 AC Drive Guide Specification

- NLS NAVIGATION LIGHT CONTROL

EC centrifugal module - RadiPac

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

Power Connections: Basic Wiring:

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

RoboClaw 2x30A Dual Channel Motor Controller

Technical data. General specifications. Indicators/operating means. 2 ms Synchronization frequency. 3 V DC Resolution

MP6500 Stepper Motor Driver, Digital Current Control

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Making Hazardous Operations Safe and Productive

MCS-2015 Basic power supply for on-off and emergency 115 VAC Electrak 1 stop. 115 VAC or 230 VAC input. 230 VAC Electrak 10 Electrak 100

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

High Pressure E/P Regulator. ITVH Series

Power Amplifiers for PVH-EDC Pumps

MOTION-8D 8-channel hoist controller with analogue remote control User s manual

PEAKTRONICS MKT-118. Actuator Controls Mounting Kit ASSEMBLY DIAGRAM F B A D D I I FEEDBACK POTENTIOMETER. Asahi A92, B92, C92, S92 Actuators

HARDWARE MANUAL TMCM Hardware Version V1.2 UNIQUE FEATURES: TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

vacon nx ac drives brake chopper unit (bcu) application user s manual

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER WITH MODBUS. VariMax50M UL/CSA. Article no. F IBC control Made in Sweden

Safety Monitoring Relays

manufactured by SF8150-ZIF14

PROGRAMMABLE STEP MOTOR CONTROLLER R

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

BAS1020 Hardware Manual Version 1.0. BA Systems Petershvilevej 1, DK-3200 Helsinge

Table of Contents 1. Overview Installation...6

EC centrifugal module - RadiPac

Universal counter UZ 9648 Counting - length measurement - metering - positioning

GIGAcontrol T. EN Translation of the Original Installation and Operating Manual V DRE-Rev.C_EN

Transcription:

Fail-Safe-Function with Positioner Fail-Safe-Function via Capacitor: The Fail-Safe-Function with Positioner is used to drive a DC- Actuator in case of missing power supply into a choosable final position. If the 24VDC-power supply gets lost at terminals 7 and 8, the actuator drives into the via jumper Err.-Drive set end position. At the same time, the relay Power-Fail picks up and the LED (Power-Fail) flashes. On return of the 24VDC-power supply, the system switches back to normal operation. The maintenance-free capacitor memory is loaded again within maximum 10 minutes. In case of heaviness or blocking of the actuator, the control switches off the actuator over the increased current consumption. At the same time, the relay Motor-Err picks up and the LED (Mot-Err) flashes. The drive is ready for use again by reversing or switching off the supply voltage for approx. 1s. Caution! The emergency function is activated when the supply voltage is switched off. This can be prevented by setting the operating switch to Manuell or by disconnecting the plug from the capacitor memory. Before commissioning of the actuator, the stabilized 24VDC-power supply should be connected to the terminals 7 and 8 when the operating switch is set to Manuell and the limit switches as well as any other positioning options are set. Meanwhile, the relay "Power Fail" is picked up and the LED (Con-Low) is lit. After this, the fault-free function of the emergency capacitor memory should be checked in auto mode by switching off the supply voltage. The charging time of an empty capacitor is about 10 minutes. In case of sufficient capacitor memory voltage, the relay "Power Fail" drops off and the LED goes out (Con-Low). In case of less capacitor memory voltage, the fail safe relay (Power- Fail) picks up and the LED flashes (Con-Low). Reverse polarity or wrong connection may destroy the circuit. Technical data: Power supply: 24VDC, stabilized Set values: 0/2-10V or 0/4-20mA Actual values: 0/2-10V or 0/4-20mA Capacitor memory capacities: 5,5F or 11F Capacitor memory voltage: 24VDC Page 1 of 11

General The Fail-Safe-Function with Positioner is used to control a electric actuator with a continuous current or voltage signal. Caution! When handling the charged capacitor memory, the stored energy (max 24VDC) must be observed. Hardware-Description The AGS positioner control consists of an internal power generation, a micro-controller as a control computer, an analog front end for the recording of analogue setpoints and potentiometer values, a digital power unit for connecting the DC motor as well as buttons, switches and LEDs as operating and display elements. Control Computer A microcontroller assesses the SET, MR and ML operating keys, the Man/Auto and Inv/Norm configuration switches, the active setting of the configuration potentiometer for current (=max. current limit) and time (= blocking threshold) and hysteresis (positioning accuracy) and the activation of the electromechanic limit-switches. As a controlled variable, the microcontroller determines the absolute position of the drive and the externally introduced setpoint. An analogue actual value will be generated as power and voltage for the current drive position and provided on the terminals. The control computer part comprises a blue status LED for the signalling of certain end position programming or operating conditions and a yellow LED that indicates the predefined setpoint / actual value range. The control computer is pre-programmed with the firmware over its 6 pole programming interface at the factory. Power Part The power part comprises the jumper switching stages for the motor, the respective LEDs as indicators for the active clockwise and counter-clockwise rotation and inputs with LED indicators for the detection of the motor discontinuation by the electro-mechanic end-switches of the drive. Analogue Front-End In the analogue circuit, the power or voltage setpoints fed externally into the terminals 12/13/14 will be converted into voltages that can be used by the control computer. However, a selection must be made via a jumper whether the voltage or power input terminal should be used. The actual values of voltage and power will be generated from a PWM signal of the control computer and will be provided to the terminals 15/16/17. A fault signal relay with indicator LED will be controlled directly by the control computer and provides a potential-free fault signal contact (1xUM) at terminals 9/10/11. The setpoint input and the actual value output are galvanically connected and connected with the 24VDC supply voltage at the earth-side and/or with the minus-side! Page 2 of 11

Technical data: Power supply: 24V Direct current, stabilized Set value-in: 0/2-10V DC Ri = 10 kω 0/4-20mA Ri = 250 Ω Actual value (active): 0/2-10V (Burden at least 5 kω) 0/4-20mA (Burden max. 500Ω) Control accuracy: ca. 1-6 % of the max. displacement depending on the regulating time, adjustable via Poti Hyst% Capacitor memory capacities: 5,5F or 11F Capacitor memory voltage: 24VDC Overview of all LEDs SM Fault signal relay RED during active fault message LL Motor in counter-clockwise rot. YELLOW when motor is switched to counter-clockwise rotation RL Motor in clockwise rotation GREEN when motor is switched to clockwise rotation STA Status BLUE or BLUE FLASHING as status indication of the control computer 2V/4mA Setpoint YELLOW at 2V/4mA, OFF at 0V/0mA, flashing when below value 2V/4mA SL1 End-switch, left YELLOW when end-switch is activated with counter-clockwise rotation SL1 End-switch, right GREEN when end-switch is activated with clockwise rotation PWR-Fail Power supply RED, when if missing power supply Con Low Capacitor RED, when low or no capacitor memoryr Übersicht Taster, Schalter, Steckbrücken und Sicherung M/A Manual/Automatic Configuration slide switch for operational mode Inv / Norm Norm: 0/2-10V or 0/4-20mA, Invers: 10-0/2V or 20-0/4mA ML Manual counter-clockwise rotation Key for counter-clockwise rotation or configuration SET Setting Key for configuration or blocking reset MR Manual clockwise rotation Key for clockwise rotation or configuration Poti Speed Setting of motor speed Poti HYST Setting hysteresis Poti Power Setting of power limit (switch-off moment of motor) Fuse Device fuse 5x20mm, 250V, 5A, time-lag in the fuse box Set value Jumper V/mA Err.-Drive Rotation direction, if missing power supply Page 3 of 11

Anschlussklemmen - 01 End-switch SL1 (normally closed) - 02 End-switch SL1 (Com) - 03 End-switch SL1 (normally opened) - 04 End-switch SR2 (normally closed) - 05 End-switch SR2 (com) - 06 End-switch SR2 (normally opened) - 07 Mains 24V + - 08 Mains 24V GND - 09 Fault signal relay NC (if no(!) fault is present, the relay is closed) - 10 Fault signal relay CO - 11 Fault signal relay NO - 12 Setpoint voltage input (0/4... 10V) - 13 Setpoint power input (0/2... 20mA) - 14 Setpoint reference potential mass (GND) - 15 Actual value voltage output (0/4... 10V) - 16 Actual value power output (0/2... 20mA) - 17 Actual value reference potential mass (GND) - 18 Motor - 19 Motor - 23 Position potentiometer reference potential mass (GND) - 24 Position potentiometer pickoff, voltage between 0... 5V proportional to the angle - 25 Position potentiometer 5V - 31 Power Fail-Relay NC (in case of no failure relay is picked up, switches potential-free) - 32 Power Fail-Relay CO - 33 Power Fail-Relay NO - 34 Capacitor 24V + - 35 Capacitor 24V GND Terminals 14, 17 and 23 (mass GND) are electrically connected Terminals 12-17 and 23-25 are electrically mounted to the low voltage potential of the controller electronics. Page 4 of 11

Basic setting before startup Setting of the Manual mode The position controller has to be set to manual mode before startup. To do this, set the switch to "Man." Caution! The Fail-Safe-Capacitor-Memory is disabled in manual mode. Caution! The Fail-Safe capacitor memory should be connected with the actuator via the plug after having adjusted the positioner. Manual-Mode (Man.) The manual mode is used to program the final positions along with driving the any manual set of the drive left or right until you reach the electromechanical limit switch. The fault relay is always activated in the manual mode, the display SM LED (red) lights up. Following functions are available in the manual mode: - manual driving to both directions - programming of both final positions Special functions for simultaneous switching on the operating voltage: - Switching the analog setpoint / actual value range - Inducing a rotation direction detection Page 5 of 11

Selection Automatic / Manual-Mode via Switch Man./Auto Selection of the set value First, the "SW" jumper must be inserted on the desired selection (voltage or current). For the selection of the setpoint value, please now enter the supply voltage to terminals 7 and 8. Switchover of the analogue Setpoint / Actual Value Ranges In general, two value ranges can be selected for the valid setpoints and actual values: 0... 10V and 0... 20mA or 2... 10V and 4... 20mA For the selection of the setpoint as control voltage or control power, apart from the correct terminal selection, the SW jumper must be connected correctly. The actual value at the respective terminals is always available both as voltage and as power. In case of simultaneous pressing of the SET key and the ML key (for at least 1s) and connection of the operating voltage, the following setpoint / actual value range is selected: 2... 10V and 4... 20mA. LED 2V/4mA flashes yellow. In case of simultaneous pressing of the SET key and the MR key (for at least 1s) and connection of the operating voltage, the following setpoint / actual value range is selected: 0... 10V and 0... 20mA. LED 2/4mA off. Signalling of the Setpoint / Actual Value Range in the Manual and Automatic Mode The state of the selected setpoint / actual value area is indicated by LED 2/4mA (yellow). Page 6 of 11

Rotation direction detection The rotation direction detection is used to check the actuator and the function of the position determine poti. It is assumed that the connection of the motor is properly conducted and this direction of rotation right turns to the right. The position controller has to be set to manual mode while programming the rotation direction. To do this, set the switch to "Man." Caution! The Fail-Safe-Capacitor-Memory is disabled in manual mode. The rotation direction detection gets activated by pressing the SET switch (at least 1s.) and applying voltage at the same time. The status LED (BLUE) flashes and the actuator gets driven for 2-3 seconds in the desired direction via the swiches ML and MR: The change of the position is determined by the potentiometer and the turning direction of the potentiometer is calculated to "right" or "left" After releasing the ML or MR-button, the status LED (blue) lights permanently. If the detection has not been successful, e.g. by faulty potentiometer or drive position on the right limit switch, the status LED (blue) flashes permanently. Rechtslauf Linkslauf SR2 SL1 AN 40 AN 100 HAK AN 40 AN 100 HAK AN 300 AN 300 Page 7 of 11

Programming of both End Positions In manual mode, end positions can be programmed at any time using the SET, MR and ML keys. Prior to the end position programming, the end-switches and the actual value potentiometer must be set. Manually move the left end position and set the adjusting cam to the SL1 end-switch. Then, manually move the right end position and set the adjusting cam to the SR2 end-switch. The potentiometer will automatically make a rough setting via its slip clutch. If the potentiometer is standing at its mechanical end stop upon arrival of the end-switch (outside of the coil), it must be re-adjusted using the slip clutch. The voltage at terminals 23 & 24 should be approx. 0.2V (SR2) or 4.8V (SL1). Rechtslauf Linkslauf SR2 SL1 JNO (4er) Justierschrauben "J" AN 40 AN 100 HAK AN 40 AN 100 HAK Schaltnocke JNO (2er) Justierschrauben "J" S4 S3 AN 300 AN 300 S2R S2R S1L S1L Programming of the right End Position With the MR key, the drive is moved into the right end position and then the SET key is pressed. Then, the Status LED (BLUE) will flash to indicate that the end position can now be programmed. By pressing the MR key within approx. 3s, the current drive position will be saved as right end position. The Status LED (BLUE) goes back to flashing permanently. Programming of the left End Position With the ML key, the drive is moved into the left end position and then the SET key is pressed. Then, the Status LED (BLUE) will flash to indicate that the end position can now be programmed. By pressing the ML key within approx. 3s, the current drive position will be saved as left end position. The Status LED (BLUE) goes back to flashing permanently. If the SET key has been accidentally pressed, you can wait until the flashing of the Status LED (BLUE) becomes permanent again. The permanent flashing indicates that the started end position programming has been completed or cancelled due to timeout. Manual Movement in both Directions With the MR key, the drive is manually driven to the right side until the mechanical end-switch has been activated. During operation, the SR2-LED (GREEN) is on. A programmed end position switch-off is ineffective. The activation of the end-switch is signalled by the SR2 LED (GREEN). With the ML key, the drive is manually driven to the left side until the latest mechanical end-switch has been activated. During operation, the SL1-LED (YELLOW) is on. A programmed end position switch-off is ineffective. The activation of the end-switch is signalled by the SL2 LED (YELLOW). Page 8 of 11

Automatic Mode (Auto) The automatic mode is used for standard operation of the position controller by means of a setpoint control signal and an actual value feedback. It must be ensured that an inspection of the drive regarding the endswitches and the rotation direction as well as regarding the correct programming of the end positions has been performed successfully in advance. The SET, MR and ML keys are completely locked in the automatic mode. Within the programmable end positions, the drive moves angle-proportionally according to the pre-set target size. Normal Operation - Inv / Norm switch on Norm Minimum setpoint means right end position. Maximum setpoint means left end position. Invers Operation - Inv / Norm switch on Inv Minimum setpoint means left end position. Maximum setpoint means right end position. The LED (BLUE) status flashes permanently. Die RL-LED (GREEN) only flashes during movements of the drive to the right. Die LL-LED (GREEN) only flashes during movements of the drive to the left. Lower Deviation / Discontinuation Setpoint During selection of the setpoint / actual value range 2... 10V and 4... 20mA, the clear lower deviation of the minimum setpoint is detected as a discontinuation and is therefore signalled as an error. Error condition: Setpoint 0... 1.6V or 0... 3.2mA at range selection 2... 10V and 4... 20mA The fault signal relay reports faults with a delay of approx. 1s, the corresponding SM-LED (RED) flashes continuously. The Status LED (BLUE) flashes continuously in a 0.25s change. The actuator turns to the position of the right end position (rating as the minimum setpoint). Having removed the failure the actuator immediately goes back to the regular operating condition and proceeds in accordance with the setpoint input. Page 9 of 11

Blocking of the Drive, Overload Detection A blocking of the drive is only detected in the automatic mode. With the Power potentiometer, the power limit for the motor and, along with it, the maximum speed for the drive can be adjusted. If this set power limit is exceeded, the motor is switched off and the fault signal relay is activated. The Status LED (BLUE) is switched off, all keys besides SET are blocked. After remedying the fault, the drive can be restarted by pressing the SET key and switching off and on of the 24VAC operating voltage. In automatic mode, the drive reacts immediately after the restart to the defined setpoints. In manual mode, the drive can be moved manually after the restart. Hysteresis / Control accuracy ca. 1-6 % of the max. displacement, depending on the regulating time, adjustable via Poti Hyst% Only when reversing the potentiometer "Hyst%" adjustable hysteresis is effective for the assessment of the control signal. Exception: After switching on the operating voltage, once no hysteresis is effective, the actuator will respond with minimum threshold. Speed Control With the speed potentiometer, the speed of the motor or of the drive can be changed. When reducing the speed, the torque of the drive will be reduced. Page 10 of 11

Overview LED Functions Manual Mode RED always on in manual mode Set setpoint / actual value range: BLUE 3x FLASHING, then OFF until none of the SET or MR and ML keys are pressed. Rotation direction detection started: RED, GREEN and BLUE Rotation direction detection implemented and detected: RED and BLUE 3x FLASHES then OFF until SET key is released Rotation direction detection implemented and NOT detected: RED and BLUE FLASHES permanently Manual motor operation: RED, BLUE and GREEN for right turn or YELLOW for left turn End position programming initiated: RED and BLUE FLASHES until timeout or execution of the setting End position programming executed: Immediate change after normal operation Normal operation standstill: RED and BLUE Normal operation with motor movement: RED, BLUE and GREEN for right turn or YELLOW for left turn additionally: ESR GREEN for activation of right end-switch ESL YELLOW for activation of left end-switch Automatic Mode Clear lower deviation of the minimum control setpoint in the configuration 4...20mA and 2...10V (from approx. 3.2mA or 1.6V) as discontinuation detection: YELLOW FLASHING (as indication for the discontinuation) Clear lower deviation of the minimum control setpoint in the configuration 4...20mA and 2...10V (from approx. 3.2mA or 1.6V) as discontinuation detection: RED and BLUE FLASHING (as indication for the discontinuation) Normal operation standstill: BLUE Normal operation with motor movement: BLUE and GREEN for right turn or YELLOW for left turn No power supply: RED (Failure notice Pwr.-Fail) Low or no capacitor memory: RED (Failure notice Con-Low) Page 11 of 11