Option Fail-Safe-Accu NRGS1-24VDC incl. positioner

Similar documents
Fail-Safe-Function with Positioner NR-C1

Fail-Safe-Function with Positioner NR-C1

Position Controller RGS3-24VDC

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Solid State Remote Power Controller E /627

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

EZ-24 EZ-24-HTB EZ-24-HTBS. Version May Publication PR-1100

Power Amplifiers for PVH-EDC Pumps

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

H2C Motor Timers will be Discontinued March 2013; Replace with H3CR-A8E Solid-state Timer

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.

AD-7830 Servo Amplifier

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical Rotary Drive

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Quick installation guide

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

SCHMIDT Programming Tool SS 20.4xx Instructions for Use

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

Geräte-Handbuch Device manual Notice pour utilisateurs

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Sensacell Troubleshooting Guide

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Blue Point Engineering

EC centrifugal module - RadiPac

- NLS NAVIGATION LIGHT CONTROL

PowerFlex 400 AC Drive Guide Specification

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

RT4F-120V/20A-WAC RECTIFIER

RT4B-110V/12A RECTIFIER

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Brushless DC Motor Controller Product Specification Assembly 025F0219

Operating instructions

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

TECHNICAL MANUAL. Man / Auto. Ten Off / On x100 psi Tension lb X1000 lb 0.

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

RoboClaw 2x30A Dual Channel Motor Controller

HERCULES-5000 INSTRUCTION MANUAL

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PROGRAMMABLE STEP MOTOR CONTROLLER R

Ellard Product Instructions

Safety Monitoring Relays

EC centrifugal module - RadiPac

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

Product and functional description

FREQUENCY CONVERTER FC101 (QUICK GUIDE)

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

Operating Instructions

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

PD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

MANUAL PLC1.01 BOARD

Peak/Valley Hold Unit (PVHU) User Manual V3.00

MCX402DR-BRD I/O expander. Operating Manual

Please keep these instructions for further reference.

Control system for rotary heat exchanger EQRB, L=3,4

Control instruments GUARDIAN 2 - GUARDIAN 3

SWTD-1000 Speed Switch / Transmitter Operating Manual

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

FEMA ELECTRÓNICA. Panel meter for process signals in ma and Vdc. Accepts both active and passive

the Interactive Catalog

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

Fuse or circuit breaker rating (A) Voltage range (V)

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Panel Meters Series M40 Model M40-A Amplicon.co m IT and Instrumentation for industry

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

MINI MCR-SL-UI-REL(-SP)

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

POWERDRIVE, PROXIDRIVE, VARMECA

Technical data. General specifications. Indicators/operating means. 2 ms Synchronization frequency. 3 V DC Resolution

02/11/2015

Proportional Control Unit (PCU)

Connections, displays and operating elements. Hand 1 / / 4

vacon nx ac drives brake chopper unit (bcu) application user s manual

For the latest information about this machine (including manuals), see the Roland DG Corp. website (

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

Control board for electromechanical gearmotors HERMES

II. Programming and Adjustments

Please keep these instructions for further reference.

Manual pressure sensors DW35311x DW36311x

Conveyor System Utilizing Safety Observation Function

VersaPoint I/O Module

Transcription:

Option Fail-Safe-Accu -24VDC incl. positioner General The electronic AGS-positioner -24VDC is used to control the electric actuator with a continuous current or voltage signal. In case of missing power supply the rotary actuator gets driven into a choosable final position. Control Computer A microcontroller assesses the SET, MR and ML operating keys, the Man/Auto and Inv/Norm configuration switches, the active setting of the configuration potentiometer for torque (= speed) and power (= blocking threshold) and the activation of the electro-mechanic limit-switches. As a controlled variable, the microcontroller determines the absolute position of the drive and the externally introduced setpoint. An analogue actual value will be generated as power and voltage for the current drive position and provided on the terminals. The control computer part comprises a blue status LED for the signalling of certain end position programming or operating conditions and a yellow LED that indicates the predefined setpoint / actual value range. The control computer is pre-programmed with the firmware over its 6 pole programming interface at the factory. Power Part The power part comprises the jumper switching stages for the motor, the respective LEDs as indicators for the active clockwise and counter-clockwise rotation and inputs with LED indicators for the detection of the motor discontinuation by the electro-mechanic endswitches of the drive. Analogue Front-End In the analogue circuit, the power or voltage setpoints fed externally into the terminals 12/13/14 will be converted into voltages that can be used by the control computer. However, a selection must be made via a jumper whether the voltage or power input terminal should be used. The actual values of voltage and power will be generated from a PWM signal of the control computer and will be provided to the terminals 15/16/17. A fault signal relay with indicator LED will be controlled directly by the control computer and provides a potential-free fault signal contact (1xUM) at terminals 9/10/11. The setpoint input and the actual value output are galvanically connected and connected with the 24VDC supply voltage at the earth-side and/or with the minus-side! Page 01 / 11

Technical data: Power supply: 24V +/-10% DC Set value-in: 0/2-10V DC Ri = 10 kω 0/4-20mA Ri = 250 Ω Actual value-out: 0/2-10V (burden min. 5 kω) 0/4-20mA (burden max. 500Ω) Control accuracy: ca. 1-6 % of the max. displacement depending on the regulating time, adjustable via Poti Hyst% Accu: Accu-capacity 0,8 Ah Akku-current 24 V nom. Overview of all LEDs SM Fault signal relay RED during active fault message LL Motor in counter-clockwise rot. YELLOW when motor is switched to counter-clockwise rotation RL Motor in clockwise rotation GREEN when motor is switched to clockwise rotation STA Status BLUE or BLUE FLASHING as status indication of the control computer 2V/4mA Setpoint YELLOW at 2V/4mA, OFF at 0V/0mA, flashing when below value 2V/4mA SL1 End-switch, left YELLOW when end-switch is activated with counter-clockwise rotation SL1 End-switch, right GREEN when end-switch is activated with clockwise rotation PWR-Fail Power supply Batt Low Akku RED, when if missing power supply YELLOW when low accu Overview of Keys, Switches and Fuses M/A Manual/Automatic Configuration slide switch for operational mode Inv / Norm Norm: 0/2-10V or 0/4-20mA, Invers: 10-0/2V or 20-0/4mA ML Manual counter-clockwise rotation Key for counter-clockwise rotation or configuration SET Setting Key for configuration or blocking reset MR Manual clockwise rotation Key for clockwise rotation or configuration Poti Speed Setting of motor speed Poti HYST Setting hysteresis Poti Power Setting of power limit (switch-off moment of motor) Fuse Device fuse 5x20mm, 250V, 5A, time-lag in the fuse box Set value Jumper V/mA Err.-Drive Rotation direction, if missing power supply Page 02 / 11

Connection Terminals - 01 End-switch SL1 (normally closed) - 02 End-switch SL1 (Com) - 03 End-switch SL1 (normally opened) - 04 End-switch SR2 (normally closed) - 05 End-switch SR2 (com) - 06 End-switch SR2 (normally opened) - 07 Mains 24V + - 08 Mains 24V GND - 09 Fault signal relay NC (if no(!) fault is present, the relay is closed) - 10 Fault signal relay CO - 11 Fault signal relay NO - 12 Setpoint voltage input (0/4... 10V) - 13 Setpoint power input (0/2... 20mA) - 14 Setpoint reference potential mass (GND) - 15 Actual value voltage output (0/4... 10V) - 16 Actual value power output (0/2... 20mA) - 17 Actual value reference potential mass (GND) Terminals 14, 17 and 23 (mass GND) are electrically connected Terminals 12-17 and 23-25 are electrically mounted to the low voltage potential of the controller electronics. - 18 Motor - 19 Motor - 23 Position potentiometer reference potential mass (GND) - 24 Position potentiometer pickoff, voltage between 0... 5V proportional to the angle - 25 Position potentiometer 5V - 31 Power Fail-Relais NC (relay is attracted when no failure) - 32 Power Fail-Relais CO - 33 Power Fail-Relais NO - 34 Accu 24V + - 35 Accu 24V GND Page 03 / 11

Basic setting before startup Setting of the Manual mode The positioner 24VDC must be set set to the manual mode before startup. To do this, the switch "Man." has to be set Manual-Mode (Man.) The manual mode is used to program the final positions along with driving the any manual set of the drive left or right until you reach the electromechanical limit switch. The fault relay is always activated in the manual mode, the display SM LED (red) lights up. Following functions are available in the manual mode: - manual driving to both directions - programming of both final positions Special functions for simultaneous switching on the operating voltage: - Switching the analog setpoint / actual value range - Inducing a rotation direction detection Page 04 / 11

Selection of the set value First, the "SW" jumper must be inserted on the desired selection (voltage or current). For the selection of the setpoint value, please now enter the supply voltage to terminals 4 and 5. Switchover of the analogue Setpoint / Actual Value Ranges In general, two value ranges can be selected for the valid setpoints and actual values: 0... 10V and 0... 20mA or 2... 10V and 4... 20mA For the selection of the setpoint as control voltage or control power, apart from the correct terminal selection, the SW jumper must be connected correctly. The actual value at the respective terminals is always available both as voltage and as power. In case of simultaneous pressing of the SET key and the ML key (for at least 1s) and connection of the operating voltage, the following setpoint / actual value range is selected: 2... 10V and 4... 20mA. LED 2V/4mA flashes yellow. In case of simultaneous pressing of the SET key and the MR key (for at least 1s) and connection of the operating voltage, the following setpoint / actual value range is selected: 0... 10V and 0... 20mA. LED 2/4mA off. Signalling of the Setpoint / Actual Value Range in the Manual and Automatic Mode The state of the selected setpoint / actual value area is indicated by LED 2/4mA (yellow). LED 2/4mA (yellow) off = Setpoint / actual value range 0... 10V and 0... 20mA LED 2/4mA (yellow) on = Setpoint / actual value range 2... 10V and 4... 20mA Page 05 / 11

Rotation direction detection The rotation direction protection is used to check the actuator and the function of the position determine poti. It is assumed that the connection of the motor is properly conducted and this direction of rotation right turns to the right. The rotation direction detection gets activated by pressing the SET switch (at least 1s.) and applying voltage at the same time. The status LED (BLUE) flashes and the actuator gets driven for 2-3 seconds in the desired direction via the swiches ML and MR: The change of the position is determined by the potentiometer and the turning direction of the potentiometer is calculated to "right" or "left" After releasing the ML or MR-button, the status LED (blue) lights permanently. If the detection has not been successful, e.g. by faulty potentiometer or drive position on the right limit switch, the status LED (blue) flashes permanently. Rechtslauf Linkslauf SR2 SL1 AN 40 AN 100 HAK AN 40 AN 100 HAK AN 300 AN 300 Page 06 / 11

Programming of both End Positions In manual mode, end positions can be programmed at any time using the SET, MR and ML keys. Prior to the end position programming, the end-switches and the actual value potentiometer must be set. Manually move the left end position and set the adjusting cam to the SL1 end-switch. Then, manually move the right end position and set the adjusting cam to the SR2 end-switch. The potentiometer will automatically make a rough setting via its slip clutch. If the potentiometer is standing at its mechanical end stop upon arrival of the end-switch (outside of the coil), it must be re-adjusted using the slip clutch. The voltage at terminals 23 & 24 should be approx. 0.2V (SR2) or 4.8V (SL1). Rechtslauf Linkslauf SR2 SL1 JNO (4er) Justierschrauben "J" AN 40 AN 100 HAK AN 40 AN 100 HAK Schaltnocke JNO (2er) Justierschrauben "J" S4 S3 AN 300 AN 300 S2R S1L S2R S1L Rutschkupplung Programming of the right End Position With the MR key, the drive is moved into the right end position and then the SET key is pressed. Then, the Status LED (BLUE) will flash to indicate that the end position can now be programmed. By pressing the MR key within approx. 3s, the current drive position will be saved as right end position. The Status LED (BLUE) goes back to flashing permanently. Programming of the left End Position With the ML key, the drive is moved into the left end position and then the SET key is pressed. Then, the Status LED (BLUE) will flash to indicate that the end position can now be programmed. By pressing the ML key within approx. 3s, the current drive position will be saved as left end position. The Status LED (BLUE) goes back to flashing permanently. If the SET key has been accidentally pressed, you can wait until the flashing of the Status LED (BLUE) becomes permanent again. The permanent flashing indicates that the started end position programming has been completed or cancelled due to timeout. Manual Movement in both Directions With the MR key, the drive is manually driven to the right side until the mechanical end-switch has been activated. During operation, the SR2-LED (GREEN) is on. A programmed end position switch-off is ineffective. The activation of the end-switch is signalled by the SR2 LED (GREEN). With the ML key, the drive is manually driven to the left side until the latest mechanical end-switch has been activated. During operation, the SL1-LED (YELLOW) is on. A programmed end position switch-off is ineffective. The activation of the end-switch is signalled by the SL2 LED (YELLOW). Page 07 / 11

Automatic Mode (Auto) The automatic mode is used for standard operation of the position controller by means of a setpoint control signal and an actual value feedback. It must be ensured that an inspection of the drive regarding the endswitches and the rotation direction as well as regarding the correct programming of the end positions has been performed successfully in advance. The SET, MR and ML keys are completely locked in the automatic mode. Within the programmable end positions, the drive moves angle-proportionally according to the pre-set target size. Normal Operation - Inv / Norm switch on Norm Minimum setpoint means right end position. Maximum setpoint means left end position. Invers Operation - Inv / Norm switch on Inv Minimum setpoint means left end position. Maximum setpoint means right end position. The LED (BLUE) status flashes permanently. Die RL-LED (GREEN) only flashes during movements of the drive to the right. Die LL-LED (GREEN) only flashes during movements of the drive to the left. Lower Deviation / Discontinuation Setpoint During selection of the setpoint / actual value range 2... 10V and 4... 20mA, the clear lower deviation of the minimum setpoint is detected as a discontinuation and is therefore signalled as an error. Error condition: Setpoint 0... 1.6V or 0... 3.2mA at range selection 2... 10V and 4... 20mA The fault signal relay reports faults with a delay of approx. 1s, the corresponding SM-LED (RED) flashes continuously. The Status LED (BLUE) flashes continuously in a 0.25s change. The drive moves into the position of the right end position (assessment as minimum setpoint). Page 08 / 11

Blocking of the Drive, Overload Detection A blocking of the drive is only detected in the automatic mode. With the Power potentiometer, the power limit for the motor and, along with it, the maximum speed for the drive can be adjusted. If this set power limit is exceeded, the motor is switched off and the fault signal relay is activated. The Status LED (BLUE) is switched off, all keys besides SET are blocked. For the removal of the fault, the drive can be switched to the manual mode. After remedying the fault, the drive can be restarted by pressing the SET key and switching off and on of the 24VAC operating voltage. In automatic mode, the drive reacts immediately after the restart to the defined setpoints. In manual mode, the drive can be moved manually after the restart. Hysteresis / Control accuracy ca. 1-6 % of the max. displacement, depending on the regulating time, adjustable via Poti Hyst% Only when reversing the potentiometer "Hyst%" adjustable hysteresis is effective for the assessment of the control signal. Exception: After switching on the operating voltage, once no hysteresis is effective, the actuator will respond with minimum threshold. Speed Control With the speed potentiometer, the speed of the motor or of the drive can be changed. When reducing the speed, the torque of the drive will be reduced. Page 09 / 11

Overview LED Functions Manual Mode RED always on in manual mode Set setpoint / actual value range: BLUE 3x FLASHING, then OFF until none of the SET or MR and ML keys are pressed. Rotation direction detection started: RED, GREEN and BLUE Rotation direction detection implemented and detected: RED and BLUE 3x FLASHES then OFF until SET key is released Rotation direction detection implemented and NOT detected: RED and BLUE FLASHES permanently Manual motor operation: RED, BLUE and GREEN for right turn or YELLOW for left turn End position programming initiated: RED and BLUE FLASHES until timeout or execution of the setting End position programming executed: Immediate change after normal operation Normal operation standstill: RED and BLUE Normal operation with motor movement: RED, BLUE and GREEN for right turn or YELLOW for left turn additionally: ESR GREEN for activation of right end-switch ESL YELLOW for activation of left end-switch Automatic Mode Clear lower deviation of the minimum control setpoint in the configuration 4...20mA and 2...10V (from approx. 3.2mA or 1.6V) as discontinuation detection: RED and BLUE FLASHING (as indication for the discontinuation) Normal operation standstill: BLUE Normal operation with motor movement: BLUE and GREEN for right turn or YELLOW for left turn Blocking of the drive, blocking time reached: RED (as fault indicator) Page 010 / 11

Option fail-safe-accu: In case of missing power supply the rotary actuator gets driven into a choosable final position. The battery is connected via a plug to the connection terminals 34 and 35. Plugged in, the accu is ready and gets loaded. From time to time, the switch checks the battery voltage. If it should weaken heavily, this behavior indicates a fault. A defective battery is indicated by the LED display (BattLow) and the fail safe relay (PowerFail) moves. If the supply voltage to the terminals + 7 and 8 gets lost, the actuator drives in the direction set by the jumper (BattDrive) until it reaches the final position. At the same time the relay (PowerFail) attracts and the corresponding LED lights up. When the power supply is restored, the system switches back to normal operation. The power supply must be between 22,0V and 25,0V, so the accu can fully be loaded.. The accus should be changed after 2 years at the latest. Wrong polarity or wrong connection may destroy the emergency position function. Technische Daten: Imax = 2,8A Betriebsspannungsbereich: 24V +/- 10% Akku-Kapazität 0,8 Ah Akku-Spannung 24 V nom. Steuereingänge: 24V DC Page 011 / 11