MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

Similar documents
LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

RCx-xxxAx Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

AD-7830 Servo Amplifier

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Products no longer available

Rotator Genius Instruction Manual v1.3.3

E1135C PDU and Pod Upgrade Procedure

Screw. Nut Guide. Features

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

COMMERCIAL. VAM24-90-(A) Series

Environdata FA ma Converter Guide

SGJ Cable Actuated Sensor Industrial CANBus J1939

Data Sheet A200 Series Electric Actuators

ASI Systems ML5740A Series

ASI Systems ML5720A Series

Control Box Setup - PRSalpha

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

N20, N34 Series Non-Spring Return Direct Coupled Actuators

COMMERCIAL. VAM24-90-(A) Series Installation Instructions

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Products no longer available

OpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Megatouch FORCE Monitor Chassis Board Replacement

SQM5 Reversing Actuator with Analog Input Signal

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Adapter Kit - Remote QSI Electronics Installation Instructions

BUILD: ARDUINO NANO + NEMA17 BIPOLAR STEPPER 12V 0.4A + EASYDRIVER

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

Rotator Genius Manual

Linear Actuators (235N)

Solid State Remote Power Controller E /627

Absolute Encoders Multiturn

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

Material: Weight: Shaft Loads: Cable: Connector:

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

MP6500 Stepper Motor Driver, Digital Current Control

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

User s Manual. Extremely Low Noise 3-phase Microstepping Driver. For 3L583M. Version All Rights Reserved

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

MODEL 245 / 345 High Range

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

NightStar. Installation, Operation, & Maintenance Instructions M /04/2016

Capacitive Proximity Sensor E2K-X

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

E3 CNC Router Troubleshooting Guide

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

4 Channel DMX Driver Instruction Manual

Component identification

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board

SGH Cable Actuated Sensor Industrial CANOpen

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

E101 - Strain Gauge Transducer Display Module. Contents

ABSOLUTE ROTARY ENCODER PROFIBUS-DP

MINI MCR-SL-MUX-V8-FLK 16

Capacitive Proximity Sensor E2K-C

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

A4988 Stepper Motor Driver Carrier

Operating Manual Bedienungsanleitung. Digital Dispense Controller

ML7421A,B Electric Linear Valve Actuators

Proportional Control Unit (PCU)

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Removal and Installation8

BA505C 2-wire 4/20mA manual setpoint station Issue 6

TECHNICAL DATASHEET Heavy Duty - Absolute Encoder AR 62/63

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

Capacitive Prox E2K-X

Robocolor II System. users guide

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

CDD Carbon Dioxide Transmitter

Capacitive Prox E2K-X

BGS (at min. setting) BGS (at max. setting)

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

HG series Hand grip Hall effect joysticks

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

E3 CNC Router Troubleshooting Guide

Global Water Instrumentation, Inc.

Transcription:

MCx-xxxAx-8.09 Contents Installation pg1-3 Mounting Wiring Connecting Power and Signal Operation pg4-6 DIP Switch settings Controlling the Actuator Torque Settings Signal loss and Calibration Troubleshooting Appendix pg7-9 Changing number of turns Speed and Torque Details Dimensions Installing a cable pg1 pg2 pg2-3 pg4 pg4 pg5 pg5-6 pg6 pg7 pg7-8 pg9 pg9 Factory Presets pg10 Installation Mounting: User s mounting surface Usually, the actuator has to be mounted and supported as shown in the picture to the left. Exceptionally, and only if the application is vibration free and the tubing is minimum ¼ dia. stainless, the actuator may be suspended on the tubing itself. Cable Entry Mounting Bracket Valve fluid connections Attachment Screws 8-32 x 1/2 Page 1 of 10

Wiring: The actuator comes standard with a Turck 5 position connector and a 20 cable with plug. Cut the cable to the length required and then connect according to the following wire color schematic: Wire color schematic for Turck6 cable: Pin Colour Function 6 White -> +24VDC 5 Black -> Power Gnd 4 Grey -> Output Signal (4..20mA)* 3 Not connected 2 Brown-> Isolated** Input Signal Gnd 1 Blue -> Isolated** Input + Signal (4..20mA) * feedback available in MCx-xxxAF version of actuator only ** isolated available in MCx-xxxAI and xxxaf versions of actuator only Otherwise, if the Turck cable is not included in your actuator, see pg.8 for more detailed wiring instructions. Connect the power: The MCx may be connected to voltages ranging from: 12 24 VDC. The power consumption will range from max. 3.0A to approx min. 100mA when the actuator is active. When not moving, the actuator draws around 50mA. DC Voltages GND V+ Terminal 1 2 3 4 5 6 P1 Remove R16 to convert to 1.. 5V input signal 1 2 3 4 5 6 Page 2 of 10

Connect the signal: Locate the correct connection terminals as shown on the previous page, then connect your input signal on pos. 1 and 2 as shown below. Feedback, if applicable, is connected to pos. 3. + - SIGNAL GND 4.. 20mA Signal source, user powered RES R16 NC 1 2 3 4 5 6 P1 Actuator NOTE 1: Usually, the actuators are shipped for 4.. 20mA signal input. For 1..5 V signal input, remove 250 ohm resistor R16. NOTE 2: Signal Gnd is NOT ISOLATED from Power Gnd in all MCx-xxxAB basic models. If your signal Gnd is different from Power Gnd use HANBAY MCx-xxxAI or MCx-xxxAF model actuators. MCx Internal External 4.. 20mA Sensing resistor NOTE 3: DO NOT CONNECT pin 3 directly or through a multimeter only to ground. A sensing resistor of 50 omhs or more needs to be present. Not observing this warning will damage the equipment. The actuator 4..20 ma output is internally supplying the signal current and can drive sufficient voltage for any sensing resistor of up to 250 ohms. The potential of the external GND after the sensing resistor may not be more than +6VDC / -2 VDC away from the power GND of the actuator. This feedback signal output is only available in HANBAY MCx-xxxAF model actuators. Page 3 of 10

Operation DIP switches: The DIP switches allow you to change the settings on your actuator. To flip a switch, gently use a small flat-head screwdriver. See chart on next page for DIP switch functionality. In this example DIPs 1, 2, 6 and 12 are on. DIP Function 1 Speed: Choose how quickly the actuator will turn the drive wheel. See pg 6-7. 2 3 Turns: The actuator usually ships from the factory with the recommended number of turns for the valve. This 4 number can be changed however. See pg 6 for relation between position of the dip switches vs. number of 5 turns. Turning on a switch will add that number of turns to the actuators movement. 6 7 Example: Turning on DIP 6 will add four turns, turning on DIP 8 adds one turn. If both DIP 6 and 8 are on, 8 then the total turns of the actuator is five. 9 Signal loss: See below. 10 Power: Set how much torque the actuator exerts on the valve lever. See below and pg 6-7. 11 12 Direction/Calibration: Toggle switch on and off while powered to re-calibrate actuator. Also sets direction in which the actuator will open and close. See pg 5. Example: The MCM model actuator turns clockwise when the signal is decreased with DIP 12 in the OFF position. For changes to rotation to take affect flip the switch and cycle the power to the actuator. Controlling the Actuator: The 4.. 20mA (or 1.. 5V) input signal represents a total span of a number of turns. I.e.: If you set the number of turns to 2, then a signal of 12mA will set the actuator to exactly 1 turn from the fully closed position. 15 ma will give: (15-4)/16=0.6875 => 68.75% of 2 turns => 1.375 turns from closed etc. With the dip switch settings, you can adjust anything between 1 and 64 turns to represent the full signal range of 4.. 20mA. Check in the table below. (1 = On 0 = Off ) Page 4 of 10

Torque Settings: To accommodate different valves and other applications with different torque requirements, the actuator can be set to apply different torque on the valve stem. Please see the box to the right and the tables on pg 7-8 to select the power setting that is right for your application. The actuator will try to reach the speed set by Dip1 and Dip2. If the torque required is too high, the actuator will automatically slow down and deliver the maximum available torque for a given Permanent Power Setting. Permanent power settings: (when operating at 24V) Dip10 Dip11 Power Off Off 16% Off On 33% On Off 66% On On 100% To deal with sticking valves, at the beginning of the first reversing movement after the seating ( zeroing ) of the valve, the actuator will apply double the power set by Dip10 and Dip11 (up to 100% power.) This pull out function is always enabled. Warning: High power settings can supply enough torque to damage your valve. Please be cautious, especially when using the 100% power setting. Signal Loss and Calibration: 1. - For actuators that are not connected to a UPS (Uninterruptible Power Supply), the loss of signal will be simultaneous with power loss. As a consequence, the actuator will not be able to move anywhere. In the shutdown process though, the actual position is automatically saved to the internal EEPROM. [this saving of the position is only happening for min. 18VDC supplies] When power is restored, the actuator will know its location and will simply start to follow the signal as received. IF YOU HAVE TO turn the actuator manually when its power is turned off, it will lose its position, and it will need to be re zeroed (as described in section 3 on the following page). 2. - For actuators that are connected to a UPS the behavior on signal loss can be set as follows: Normal position of DIP9: OFF With DIP9 in the off position, the actuator will ignore the signal if it is lost (I.E.: if the signal falls below 0.7V) and simply remain in its current position. Note: if the sensing resistor R16 is removed (for 1..5V input signals), we recommend placing a 10K resistor between signal and signal GND. Predetermined signal loss position DIP9: ON With DIP9 in the on position, the actuator will move to a predetermined position when the signal is lost (I.E.: if the signal falls below 0.7V). Setting of the predetermined signal loss position: a. - turn Dip9 to the off position b.- re zero the actuator by sending and holding an input signal between 2.8 and 4.16 ma (0.7 to 1.04V) wait until the device is re-zeroed, (i.e: the valve is closed) c. - by varying the input signal, move the actuator to the position that is going to be the predetermined signal loss position. Page 5 of 10

d. - switch Dip9 to the on position. The current actuator position will be saved as the default signal loss position. (The default signal position is an absolute actuator position. I.e.: not a signal value.) 3. - Re Zeroing the actuator and initiating calibration routine: The actuator will re-zero when the input signal is between 2.8 and 4.16mA (0.700V 1.040V). It will turn clockwise until the actuator has reached the fully closed position of the valve. Different valves mounted to actuator need the calibration routine initiated manually. This is done by toggling dip switch 12 in the one way and back to its original position while the actuator is powered. This will initiate the calibration routine and is essential when changes have been made to the valve. If you need to re-zero in the opposite direction (i.e: for pressure regulators, which typically go to the top fully open position at 4mA) change the setting of Dip switch DIP12 and cycle power. 4. - Feedback calibration: [MCx-xxxAF model actuators only] The current feedback will be calibrated from the factory. To re-calibrate the feedback: a.- turn off the actuator, and disconnect the feedback and input signals b.- connect the feedback signal to the signal input. Also connect the power and signal grounds. c.- d.- e.- Troubleshooting: power up the actuator with this signal back-loop setup. Short SP5. It will automatically run a special routine to calibrate the feedback signal to the signal input. The whole process takes about 1.5 seconds. turn off the power and reconnect the actuator as normal. Upon noticing a problem, your first step should almost always be to recalibrate the actuator by switching DIP 12, then switching it back to its original position, all while the actuator is powered. This alone can solve basic problems. See section 3 on this page for more details. If the actuator does not move, try following these steps: 1) Re-calibrate the actuator. This will move the actuator regardless of what signal it is receiving. 2) A sticking valve may be the problem. Remove the valve from the actuator, and re-test the actuator. 3) Remove power. Re-check the wiring and the power/signal apparatus. Power actuator, and re-calibrate. If the problem persists, please call Hanbay for technical support. Page 6 of 10

Changing the number of turns: Appendix The 4.. 20mA (or 1.. 5V) input signal represents a total span of a number of turns. I.e.: If you set the number of turns to 2, then a signal of 12mA will set the actuator to exactly 1 turn from the fully closed position. 15 ma will give: (15-4)/16=0.6875 => 68.75% of 2 turns => 1.375 turns from closed etc. With the dip switch settings, you can adjust anything between 1 and 64 turns to represent the full signal range of 4.. 20mA. Check in the table below. (1 = On 0 = Off ) Total Turns Dip4=0 Dip5 Dip6 Dip7 Dip8 reserved 0 0 0 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 10 1 0 1 0 11 1 0 1 1 12 1 1 0 0 13 1 1 0 1 14 1 1 1 0 15 1 1 1 1 For more turns set Dip3 and Dip 4 as follows: Dip3=0 Dip3=1 Dip4=0 0 +32turns Dip4=1 +16 turns +48turns Note: This actuator can accommodate up to the following number of turns on its different models: MCL -xxxax 63 turns MCJ -xxxax 63 turns MCM- xxxax 63 turns MCK -xxxax 63 turns MCH- xxxax 29 turns WARNING: Be sure that the number of turns the actuator is set for is LESS than the number of turns for the valve. The actuator should not stop itself on a fully opened valve. It can damage the valve, and the actuator will lose its position. Speed and Torque Details: The maximum speed of the actuator can be set by using the first two positions of the DIP switch selector. As a result of this setting, the actuator will limit the maximum speed. The tables below show the maximum torques that can be expected at the given maximum speeds. The torque available also depends on the voltage provided in the power connection and on the Permanent power settings on DIP 10, 11 as shown below. * Speed and Torque of MCL-xxxAx Actuators NOTE: If actuator is MCJ-xxxAx, divide torque values by 3. Time for Torque in in-lbs Torque in in-lbs Torque in in-lbs Torque in in-lbs Dip1 Dip2 1 turn (sec) 16% Power* 33% Power* 66% Power* 100% Power* 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC OFF OFF 5 2 5 5 11 9 21 14 32 OFF ON 4 2 5 4 9 7 19 11 28 ON OFF 3 1 4 2 8 5 16 8 25 ON ON 1 N/A 4 N/A 8 N/A 15 N/A 23 To convert in-lbs to Nm, divide the in-lbs value by 9 Page 7 of 10

Speed and Torque of MCM-xxxAx Actuators NOTE: If actuator is MCK-xxxAx, divide torque values by 3. Time for Torque in in-lbs Torque in in-lbs Torque in in-lbs Torque in in-lbs Dip1 Dip2 1 turn (sec) 16% Power* 33% Power* 66% Power* 100% Power* 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC OFF OFF 16 6 15 13 30 27 60 40 90 OFF ON 12 5 13 11 27 21 53 32 80 ON OFF 8 4 12 7 23 15 47 22 70 ON ON 4 N/A 11 N/A 22 N/A 43 N/A 65 To convert in-lbs to Nm, divide the in-lbs value by 9 Speed and Torque of MCH-xxxAx Actuators Time for Torque in in-lbs Torque in in-lbs Torque in in-lbs Torque in in-lbs Dip1 Dip2 1 turn (sec) 16% Power* 33% Power* 66% Power* 100% Power* 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC OFF OFF 60 22 51 44 101 91 203 135 304 OFF ON 45 17 44 37 91 71 179 108 270 ON OFF 30 14 41 24 78 51 159 74 236 ON ON 15 N/A 37 N/A 74 N/A 145 N/A 219 To convert in-lbs to Nm, divide the in-lbs value by 9 N/A in these tables means: The actuator will not be able to reach the requested speed for this combination of power / voltage / speed settings. It will always run slower to be able to overcome the internal torque requirements. So these points can be set but the expected end speeds would not be reached. Note: 66% setting and 100% setting require voltage supply minimum values as follows: - Supply voltage needs to be min 14 VDC for 66% setting - Supply voltage needs to be 16 VDC for 100% setting - When operating above 20VDC and 66% power, Duty cycle is reduced to 50% - 25% maximum. At these levels, the electronics produce more heat which must be dissipated (depending on environmental temperature) Note: Digital potentiometer functionality is disabled for supply voltages below 18VDC, so the actuator position will not be retained on power-loss, on power-up the actuator will need to be re-zeroed every time. Page 8 of 10

Main Dimensions: Cable Installation: MCL-xxxAx MCM-xxxAx MCJ-xxxAx MCK-xxxAx models MCH-xxxAx models Select a connection cable with 5 leads. The liquid tight strain relief on the base of the actuator is designed to accommodate a cable of O.D. 2.5-6.5mm (0.10-0.26in). Be sure to not use a cable with an OD that is no bigger than this! 1 2 3 4 1.- Remove the liquid tight fitting from the actuator casing and insert the cable into it. 2.- The cable has to be stripped of its jacket for 2 inches (50mm) and the wires need 1/8 (3mm) stripped ends. 3.- Bend the wires so that insertion becomes easy. 4.- Carefully insert the cable into the actuator base. Mind the red motor cable and its plug into the board. Moving the plug out of its fully inserted position may cause malfunction of the actuator. 5 6 7 8 5.- Put the liquid tight fitting back and tighten (lightly with tool). 6.- Hand tighten the liquid tight fitting to establish seal. 7.- Connect wires according to your application (see page 2,3). 8.- Mount actuator cover and tighten 4 screws. Page 9 of 10

Factory Presetting Invoice No: Line item : Full Hanbay Part Number: M C - A - - Hanbay Electronics: A Valve Manufacturer: Valve Number of turns: Hanbay Firmware: A Valve Type: Needle Valve Globe Valve Ball Valve Other (specify) The Dipswitch settings we applied to your actuator are: (1= On, 0= Off ) Dip1 Dip2 Dip3 Dip4 Dip5 Dip6 Dip7 Dip8 Dip9 Dip10 Dip11 Dip12 Notes & recommendations: FIRMWARE SETTINGS MCL FULL_RES 0 LOW_TORQUE 0 MULTI_TURN 1 MULTI_TURN_EX_GEARSTAGE 0 DEG_90 0 DEG_97 0 DEG_90_EX_GEARSTAGE 0 DEG_97_EX_GEARSTAGE 0 MIN_MOVE 2 MIN_CHANGE_MOVE 8 P_GAIN 9 D_GAIN 25 DECEL_REGION 150 MAX_FULL_SPEED 30 MAX_STALL_PERIOD 6 TH_TO_DECEREASE_RESOLUTION 24 Page 10 of 10