Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

Similar documents
GS Dupline Profinet Gateway. Benefits. Description

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

NA User Manual. Copyright(C) * CREVIS Co.,Ltd * Support * URL :

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

MODEL: WL40EW2F. Wireless I/O WL40F Series

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

IntesisBox Modbus Server Panasonic

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

mipick Pick-by-Light System

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

PWR. Power Module Slots

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

HRM-0800 Instruction Manual

MODEL: GR8-EM. Communication Adaptor GR8 Series

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

MIC-2 MKII, Multi-instrument DATA SHEET

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

MIC-2 Multi-instrument DATA SHEET

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

BL compact fieldbus station for DeviceNet 4 Analog Outputs for Voltage BLCDN-4M12S-4AO-V

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

EGW1-IA3-MB User s Manual

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

HART NETWORK UNIT (HNU)

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

CEM M-ETH INSTRUCTION MANUAL (M060B A)

Quick Start Manual G2-2 Series with Ethernet Interface

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

DI572 Digital Input Module

IntesisBox Modbus Server Fidelio IP

Voltage Transducer UMT516 / MT516

Industrial 2-port RS422/485 Modbus Gateway IMG-120T

LBVR1718. Description. Features channel paperless recorder

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ZBRN1. Main. Device short name

BL compact fieldbus station for DeviceNet 2 Analog Inputs for Current or Voltage and 2 Analog Outputs for Voltage BLCDN-4M12S-2AI2AO-VI

Technical data. Safety notes. Product features

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

02/11/2015

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

CM597 Ethernet Communication Module

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Installation / Control / Monitoring Technique

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

02/11/2015

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM221M16R controller M IO relay

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

SA2WEB24. Central unit module. Benefits. Description

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

EtherCAT Remote I/O Terminal GX series

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

DC561, digital input/output module,

NetBiter I/O Extender User Manual

Momentum 171 CCC Processor with Ethernet Communication Port

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

TM221CE40T controller M IO transistor PNP Ethernet

Communication Gateway COM 610. Product Guide

TM241CE24T controller M IO transistor PNP Ethernet

TM3AI4 module TM3-4 analog inputs

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

VersaMax Micro and Nano Technical Product Presentation

TM221CE24R controller M IO relay Ethernet

Energy Management Energy Transducer Type ET112

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Instruction Manual Power Distribution System SVS16-EN-XX

Transcription:

Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G 3891 0052 Built-in Dupline channel generator Modbus/TCP Slave 10 and 100 Mbit operation, full or half duplex Twisted pair cables Read/control 128 Dupline inputs/outputs Split-I/O mode selectable (128 inputs and 128 outputs) Support of 3 1/2 digit BCD and AnaLink analog formats For mounting on DIN-rail (EN 50 022) LED indicators for supply, Dupline carrier and fault LED indicators for Ethernet link, module status and activity AC power supply Product De scrip tion Type Selection Dupline Channel Generator with the function of an Ethernet Modbus/TCP slave. This means that digital as well as analog Dupline I/O s can be read/controlled from Modbus/TCP masters (PC s, PLC s etc.). The unit supports both Analink and Multiplexed analog signals. Several Dupline gateways can be connected to the same Ethernet network. Ordering Key Type: Dupline H8-Housing Type no. Supply G 3891 0052 230 Supply Ordering no. 115/230 VAC G 3891 0052 230 Input/Output Spec i fi ca tions Ethernet Protocol Connector Communication Speed IP address setting Dielectric voltage Ethernet Dupline Dupline Output voltage Output current Short-circuit protection All channels detector Output impedance Sequence time Modbus/TCP RJ45 (standard) 10 or 100 Mbit operation via DIP-switches or PC (arp command) 8.2 V 100 ma 15 Ω 132.3 ms (@ 128 channels) Adjustments 1 x 16 pos. rotary switch No. of Dupline channels 8.. 128 in steps of 8 DIP-switch 1 Dupline mode (Normal/Split I/O) DIP-switch 2 Dupline analog DIP-switch 3 Analog input protocol DIP-switch 4 Analog output protocol DIP-switch 5-12 IP address CE-marking Specifications are subject to change without notice (21.08.2006) 1

General Spec i fi ca tions Power delay < 2.5 s until start of Dupline carrier. < 40 s until correct reading of AnaLink values Indication for Supply Dupline carrier LED, yellow Fault LED, red Ethernet Link Ethernet Module Status /red Ethernet Activity Environment Degree of protection IP 20 Pollution degree 3 (IEC 60664) Operating temperature 0 to +50 C (+32 to +122 F) Storage temperature -20 to +85 C (-4 to +185 F) Humidity (non-condensing) 20 to 80% RH Mechanical resistance Shock 15 G (11 ms) Vibration 2 G (6 to 55 Hz) Dimensions H8-housing Material (see Technical information) Weight 540 g Supply Spec i fi ca tions Power supply Overvoltage cat. III (IEC 60664) Rated operational voltage through term. 21, 22, 23 & 24 See wiring diagram 230 230 VAC ± 15% (IEC 60038) 115 115 VAC ± 15% (IEC 60038) Frequency 45 to 65 Hz Rated operational power 11 VA Rated impulse withstand voltage 230 4 kv 115 2.5 kv Dielectric voltage Supply - Dupline Supply - RS 485 Wiring Diagrams Power supply 230 VAC Power supply 115 VAC DUPLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 21 DUPLINE SETTINGS D+ D 1 2 3 4 1 2 4 3 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 115V 115V P N P N SUPPLY NO. CHANNELS ETHERNET CNECTOR IP ADDRESS LEDS STATUS Mode of Operation The Dupline Ethernet Gateway is a Dupline Channel Generator with the function of a Modbus/TCP slave. This means that the 128 Dupline I/O s can be read/controlled by Modbus/TCP masters like PLC s and PC interface cards from many different suppliers. Several Dupline Gateways can be connected to the same network and operate together with other Ethernet modules like operator panels, MMI s I/O modules etc. Dupline Configuration switches The unit is equipped with the following Dupline configuration switches. (See also switch settings) 1x16 position rotary-switch for selecting Number of Dupline Channels in the range 8..128 (in steps of 8). The selected letter indicates the last channel group available on Dupline. If e.g. H is selected, the 64 channels in groups A..H will be available. DIP-switch (1) for selection of Dupline Operation Mode. In "Normal" mode, Dupline operates as a peer-to-peer system where the channel generator automatically establishes a connection between Dupline inputs and Dupline outputs which are coded to the same Dupline address. If e.g. an input coded for B5 is activated, the output(s) coded for B5 will also be activated. Consequently a Dupline output can either be activated through the output-data received on Ethernet or by an active Dupline input coded for the same Dupline address. In "Split I/O" mode, the Dupline inputs and Dupline outputs are created independently by the channel generator. If e.g. and input coded for B5 is activated, the Gateway will make the information available on Ethernet (like in normal mode), but it will not automatically activate the Dupline output(s) coded to B5. The Dupline outputs are controlled exclusively through the output data received on Ethernet. Note: Analink output as well as BCD multiplex data only work in split I/O mode. DIP-switch (2) for selection of analog data. In OFF position only Digital In/Out data are transferred. To enable analog data-i/o handling this DIPswitch must be. DIP-switch (3) for selection of Analog input operation mode. When OFF the analog input data are read as AnaLink. Each channel from C1 to P8 is read as 8 bit analog data. When the analog input data are considered as 3 _ digit BCD multiplexed data. The multiplex-control (Synchronization) are automatically set to operate on channels A1..A4, which then cannot be used for other purposes. 2 Specifications are subject to change without notice (21.08.2006)

Mode of Operation (cont.) DIP-switch (4) for selection of Analog Output operation mode. When OFF the Analog outputs are emitted as AnaLink. When the Analog Output-data are emitted as 3 _ digit Multiplexed data, and channels A1..A4 will control the multiplex addressing. Note: Change of Dip-switch settings During operation, may cause reset of the Gateway. Dupline Input Data A part of the Gateway input processor reads all the 128 Dupline -channels as Digital inputs (16 bytes) and another part reads the 112 channels (C1 to P8) as Analog inputs. Each Analog value is represented as a 16 bit word with MBS as sign and 15 bits of magnitude. This results in a total of 224 bytes containing all analog inputdata. Since the sign of a valid Dupline analog value is always positive, the range is 0..32767, where 32767 corresponds to the max analog input. It is up to the user to read the data in the correct area (digital or analog) according to the type of module (digital or analog) he has installed on a Dupline address. All data are mapped with Digital input bytes starting at relative address 00 followed by the analog data. See In/out data mapping. Dupline Output Data A memory area of 16 bytes is available for control of the outputs of the 128 Dupline channels. If Normal mode is selected, the outputs can also be controlled from Dupline transmitters (OR-function). A memory area of 224 bytes is available for control of the 112 Analog output values. The data must be entered in the range 0..32767. The Gateway will convert them to the right Dupline format in accordance with the selected Analog Output operation mode. However,Analink output works only in split I/O mode. When Analog transmission is selected it is important to write the value FFFF Hex (-32767 decimal) to all those of the 112 output addresses where no analog output is desired. Otherwise the digital transmission will be disturbed. Also, in case 3 _ digit BCD is selected, it should be noted that sending out analog values on one or more multiplex addresses on a double-group (e.g. C-D) will disable the use of this entire double-group for digital transmission. However, BCD multiplex data also works only in split I/O mode. IP address information IP address The IP address is used to identify each node on the TCP/IP network. Therefore, each node on the network must have a unique IP address. IP addresses are written as four decimal integers (0-255) separated by periods, where each integer represents the binary value of one byte in the IP address. This is called dotted-decimal notation. Address 10000000 00001010 00000010 00011110 is written as 128.10.2.30 Subnet Mask The IP address is divided into three parts - net ID, subnet ID and host ID. To separate the net ID and the subnet ID from the host ID, a subnet mask is used. The subnet mask is a 32- bit binary pattern, where a set bit allocates a bit for network/subnet ID, and a cleared bit allocates a bit for the host ID. Like the IP address, the subnet mask is commonly written in dotted-decimal notation. To make the IP address 128.10.2.30 belong to subnet 128.10.2, the subnet mask shall be set to 255.255.255.0. Subnet Mask: 11111111 11111111 1111111 00000000 (255.255.255.0) Net ID /Subnet ID/Host ID Important Note: To be able to establish communication between two devices both devices must belong to the same subnet. If not, the communication must be done through a gateway. It is therefore recommended to configure the module to the same subnet as your PC (If e.g. the PC has IP address 192.168.2.21, then the IP address of the Dupline Ethernet Gateway must have an IP address 192.168.2.n, where n is a number in the range 1..255). IP address selection The module offers two ways to configure the IP-address: By using the DIP switches in the front By using the arp-command from a PC Using the Configuration Switch for selection of IP address The configuration switch provides an easy way to configure the module for intranet use. The switch represents the binary value of the last byte in the IP address. If the switch is set to a value between 1-255 the module will use the settings described below. (If the switches are all in the OFF-position, corresponding to the value 0, then the Gateway is set up to be configured using the arpcommand from a PC.) IP address: 192.168.0.n Subnet mask: 255.255.255.0 Gateway address: 0.0.0.0 (No gateway set) The last byte (n) represents the binary value of the switches. Subnet mask and Gateway address settings are fixed to the above values when using the configuration switches. The switches are set to 00010100 (20 decimal) The IP address of the module will be set to 192.168.0.20 Note: These settings can only be used on an intranet. This is because the IP address that is being set belongs to the private address set. Using the Address Resolution Protocol (ARP) for selection of IP address The IP address can be configured (or changed during runtime) using the ARP command from a PC. Below is an example on how to change the IP address from a MS DOS window (which is normally available under "accessories" as "Command prompt" in the windows programs menu). arp -s <IP address> <MAC address> ping <IP address>arp -d <IP address> To set the IP address to 192.168.2.21 on a Dupline Ethernet Gateway with MAC address 00-30-11-02-10-DA the following commands should be issued in the "command prompt" window: arp s 192.168.2.21 00-30-11-02-10-DA ping 192.168.2.21 arp d 192.168.2.21 The arp -s command will store the IP and MAC addresses in the PC s ARP table. When the ping command is executed, the PC sends this information to the module using the MAC address. The module detects that it was addressed with the correct MAC address and adopts the IP address sent by the PC. (The arp -d command is optional, but it removes the static route from the PC ARP table). This method can be used to reconfigure modules that already has been configured, or even to reconfigure modules outside the host s subnet. Important note: The MAC address is printed on a label on the bottom side of the module. Important note: As the Arp command automatically configures the subnet mask to 255.255.255.0, the first three bytes of the IP address must be the same as for the PC executing the command. PC 192.168.2.67 Module- 192.168.2.n (Where n is a value between 1 and 254) Specifications are subject to change without notice (21.08.2006) 3

Modbus Memory Map Input (Hexadecimal notation) 0000 0000 A-P Digital 8 words 0008 0008 C-D Analog 16 words 0018 0024 E-F Analog 16 words 0028 0040 G-H Analog 16 words 0038 0056 I-J Analog 16 words 0048 0072 K-L Analog 16 words 0058 0088 M-N Analog 16 words 0068 0104 O-P Analog 16 words Outputs (Hexadecimal notation) 0400 1024 A-P Digital 8 words 0408 1032 C-D Analog 16 words 0418 1048 E-F Analog 16 words 0428 1064 G-H Analog 16 words 0438 1080 I-J Analog 16 words 0448 1096 K-L Analog 16 words 0458 1112 M-N Analog 16 words 0468 1128 O-P Analog 16 words Analog input data - memory map 0008 0008 Analink C1 or C-D mux 0 0009 0009 Analink C2 or C-D mux 1 Analog output data - memory map 0408 1032 Analink C1 or C-D mux 0 0409 1033 Analink C2 or C-D mux 1 0017 0023 Analink D8 or C-D mux F 0018 0024 Analink E1 or E-D mux 0 0417 1047 Analink D8 or C-D mux F 0418 1048 Analink E1 or E-D mux 0 0076 0118 Analink P7 or O-P mux E 0077 0119 Analink P8 or O-P mux F 0476 1142 Analink P7 or O-P mux E 0477 1143 Analink P8 or O-P mux F Digital input data - bit memory map Digital input data - single bit references Digital output data - bit memory map Digital output data - single bit references Channel Channel MSB LSB 0000 0 A1 MSB LSB 4000 16384 A1 0000 0000 A1 B8 0001 1 A2 0400 1024 A1 B8 4001 16385 A2 0001 0001 C1 D8 0002 2 A3 0401 1025 C1 D8 4002 16386 A3 0003 3 A4 4003 16387 A4 0006 0006 M1 N8 0406 1030 M1 N8 0007 0007 O1 P8 0007 7 A8 0407 1031 O1 P8 4007 16391 A8 0008 8 B1 4008 16392 B1 000E 14 B7 400E 16398 B7 000F 15 B8 400F 16399 B8 0010 16 C1 4010 16400 C1 0011 17 C2 4011 16401 C2 007E 126 P7 407E 16510 P7 007F 127 P8 407F 16511 P8 ANALOG DATA FORMAT: All analog values are scaled linearly to 15 bit binary format (Min analog value: 0, Max analog value 32767) 4 Specifications are subject to change without notice (21.08.2006)

Supported Modbus Function Codes Function Code Function Name Class Affects Area 1 Read coils 1 IN/OUT 2 Read input discretes 1 IN/OUT 3 Read multiple registers 0 IN/OUT 4 Read input registers 1 IN/OUT 5 Write coil 1 OUT 6 Write single register 1 OUT 7 Read exception status 2-15 Force multiple coils 2 OUT 16 Force multiple registers 0 OUT 22 Mask write register 2 OUT 23 Read/Write registers 2 IN/OUT Switch Settings 1 2 3 4 Number of Dupline Channels A: Group A 8 channels B: Groups A..B 16 channels P: Groups A..P 128 channels 1: Dupline Operation Mode OFF: Normal (Peer-to-Peer) : Split I/O mode 2: Dupline Data Transfer mode OFF: Digital only : Digital + Analog 3: Analog Input protocol OFF: AnaLink : Multiplex 4: Analog Output protocol OFF : AnaLink On: Multiplex IP Address 0 1 8 IP Address Set DIP 8 arp 00000000 192.168.0.1 00000001 192.168.0.2 00000010 192.168.0.253 11111101 192.168.0.254 11111110 192.168.0.255 11111111 Ethernet LED Indicators (right hand side of the module) OF Blinking LED 1 The module has a link The module has no link LED 2 IP address set via arp cmd IP address set via switches LED 4 Blinks when a packet is received or transmitted Dimensions (mm) H8-housing Specifications are subject to change without notice (21.08.2006) 5