Dupline Fieldbus Components Channel Generators/Interfaces Types D390 G300 G396 G39 Standard channel generator. 77 x x 70 Controller and Modbus Interface with built-in GSM Modem (option) or external Radio Modem. DIN-Rail, H Plug & Play RS232 /RS5 Interface with built-in protocols for specific PLC brands and Modbus. 77 x x 70 Fieldbus Gateways for Profibus-DP and DeviceNet. DIN-Rail, H 5 = 5 VAC 2 = 5-30 VDC x Contact/NPN input+ x PNP 0-30 VDC output 2 x RS232+ x RS5 Possibility for alarms, monitoring and control via SMS messages. 230 = 5/230 VAC 00 = 0-30 VDC Possibility for 3-wire operation with DC-power on the 3 rd wire. 700 = 20-30 VDC 230 = 5/230 VAC -2 Up to 32 controllers can be networked together via RS5 or Ethernet via converter module. Built-in protocol for specific PLC brands for easy interfacing. Without GSM Modem With GSM Modem Optolink LG GE-Fanuc Mitsubishi Omron Modbus Allen-Bradley Schneider Koyo Matsushita Siemens Toshiba IDEC Profibus-DP Devicenet D390 0000 G300 005 G300 05 G396 0000 G396 000 G396 0002 G396 0003 G396 000 G396 0005 G396 0006 G396 0007 G396 000 G396 0009 G396 000 G396 00 G396 002 G39 0020 G39 0050 2
Dupline Fieldbus Components Digital Input Modules Digital Output Mod. Types G320 G500 06 G20 70 G330 / G330 Input module for external supply with optoisolated inputs. 9 x 22.5 x 56 Dupline powered single input Module. DIN-Rail, H 36 x 5 x 5 Input module for counting of pulses from energy meters, item detectors etc. (H) 77 x x 70 (H) Fieldbus Gateways for Profibus-DP and DeviceNet. DIN-Rail, H (G330553) Contact/NPN Voltage (6-265 VAC/DC) 5 = 5 VAC 00 = 0-30 VDC Contact input SO contact input (DIN 3 6) Max. count frequency: Hz 72 = 5-30 VDC, 2,, 5 A SPDT relay 5 A SPST relay 0.7 A NPN transistor 0.7 A PNP transistor 5 = 5 VAC 00 = 0-30 VDC 2 = 5-30 VDC -2-2 IP 0-20 C to +60 C Decentral counting. Counter values stored in non-volatile memory. -2 Contact/NPN Voltage x 5 A SPDT 2 x 5 A SPDT x 5 A SPST x 5 A SPST x 0.7 A NPN x 0.7 A PNP G320 550 G320 5502 G500 06 G20 70 G330 9 G330 229 G330 3 G330 553 G330 55 G330 552 CARLO GAVAZZI Automation Components Specifications are subject to change without notice. 3
Dupline Fieldbus Components Digital I/O Modules Analog Input Modules Types G30 3 G329 670 G320 6 G320 Combined I/O module for external supply with optoisolated inputs and relay outputs. Universal analog input module for external supply. 77 x 36 x 70 Analog input module powered from Dupline and input signal. DIN-Rail, H2 77 x 36 x 70 Dupline-powered Analog input module for Pt00 temperature sensor. DIN-Rail, H2 2 x 6-265 VAC/DC inputs+ 2 x SPST relay outputs 5 = 5 VAC 2 = 5-30 VDC x isolated analog input Input type individually configurable (0-20 ma, -20 ma, 0-0 VDC) 5 = 5 VAC 00 = 0-30 VDC x -20 ma input Dupline network and -20 ma input signal. x Pt00 3-wire input Ranges: (-50 C to +0 C) (+30 C to +20 C) (-0 C to +00 C) -2 Protocol freely selectable (Analink, Multiplexed BCD or -bit). Uses Analink -bit protocol. Uses Analink -bit protocol. Built-in cable compensation. -50 C to +0 C +30 C to +20 C -0 C to +00 C G30 3 G329670 G320 6 G320 G320 2 G320 3
Dupline Fieldbus Components Analog Output Mod. Digital Sensors Analog Sensors Types G339 670 G60 5 G90 0 G9 00 77 x 36 x 70 Universal analog output module for external supply. M x 55 Dupline powered inductive proximity switch. M Ø x 6 Dupline powered magnet proximity switch. Cylindrical 67 x 35 x 5 Dupline powered temperature sensor with built-in Pt000 transducer. Flat-pack x analog output Output type configurable for 0-20 ma, -20 ma or 0-0 VDC 5 = 5 VAC 00 = 0-30 VDC Detects proximity of metal objects. Detects proximity of magnet. Transmits the measured temperature as an Analink value. Range: -30 C to +60 C Protocol freely selectable (Analink, Multiplexed BCD or -bit). -25 C to +70 C -30 C to +0 C Available with cable or M2 connector. Flush mounting. -2 Available in Ø plastic housing or with M metal thread. -25 C to +70 C -55 C to +5 C Fitted with M2 connector. Cable M2 plug Ø M G339 670 G60 5 G60 5- G90 0 G90 0-G G9 00 CARLO GAVAZZI Automation Components Specifications are subject to change without notice. 5
Dupline Fieldbus Components Display Modules Special Modules Types D6369 675 GTD50 GTS377S D392 0000 x 96 x 3 LED display with x 7-segments BCD digits for read-out of analog values. Panel mounting 77 x 6 x LED Text display with 2 rows x 20 characters. Panel mounting 3 x 7 x 57 5.7 LCD Touch Screen with 6 colours STN Display. Resolution: 320 x 20 Panel mounting 77 x x 70 Dupline signal Repeater for extension of transmission distance. DIN-Rail, H Multiplexed BCD or -bit analog values. Freely scalable and with limit outputs (LOLO, LO, HI, HIHI) 230 = 5/230 VAC Digital and Analink. User-defined text messages linked to Dupline channels. Read-out of Analink values Dupline control via front keys. -32 VDC Digital and Analink. Alarms, dynamic link to bitmap files and text, customisable touch buttons, history buffer. 2-27 VDC Adjusts automatically All Dupline signal types. Recreates the Dupline signal carrier through channelgenerator output. 5 = 5 VAC 0 C to +60 C -25 C to +5 C IP 65 (front) -20 C to +60 C IP 65 (front) -20 C to +60 C D6369 675 GTD50 GTS377S D392 0000 6
Dupline Fieldbus Components Converters Tools Types G39 000 G392 / G393 GAP605 GTU Private line Modem for long distance transmission of Dupline signals. Optical repeater for converting Dupline from electrical to optical transmission media. 20 x 65 x 22 Dupline coding device for assigning adresses to Dupline I/O modules and sensors. Handheld 5 x 90 x 2 Dupline test unit for monitoring and control of Dupline channels. Handheld Adjusts automatically Digital, -bit analog, non-multiplexed 3 /2 digit BCD analog. 5 = 5 VAC Adjusts automatically All Dupline signal types. 230 = 5/230 VAC NA 9 V battery Adjusts automatically Digital, multiplexed BCD and -bit analog signals. Operates pair-wise. Operates pair-wise. Runs on 50/25, 62.5/25 or 00/0 micro m with STN connectors. IP 0-20 C to +60 C IP 0 Options for latching digital signals and for reading multiplexed BCD values. Optical/electrical converter /optical converter G39 000 G392 0000 G393 0000 GAP605 GTU Software DUPDATACC Software package with DDE-driver and ActiveX driver for G300. Controller and interface unit. Adjusts automatically All Dupline signal types. Copy and paste dynamic Dupline links into EXCEL spreadsheets. DUPDATACC CARLO GAVAZZI Automation Components Specifications are subject to change without notice. 7
Dupline Building Automation Components Channel Generator/Interfaces Light Switches Types G390 G300 G50 G0 77 x x 70 Controller and Modbus Interface with printer port. DIN-Rail, H 77 x x 70 Controller and Modbus interface with built-in GSM Modem (option) or external radio Modem. DIN-Rail, H x x 2.5 Light switch with built-in bus interface and individually adressable pushbuttons and LED s. ELKO design 55 x 55 x Light switch with built-in bus interface and individually adressable pushbuttons and LED s. FUGA design x RS232 x Centronics port for event print-outs. 00 = 0-30 VDC 230 = 5-230 VAC x Contact/NPN input+ x PNP 0-30 VDC output 2 x RS232+ x RS5 Possibility for alarms, monitoring and control via SMS messages. 00 = 0-30 VDC 230 = 5-230 VAC 6 to 3 Pushbuttons (PB) to 3 LED indicators x Pushbuttons x LED indicators Up to 32 controllers can be networked together via RS5 or Ethernet via converter module. Without GSM Modem With GSM Modem PB + LED 2 PB + 2 LED 3 PB + 3 LED Grey colour White colour G390 00 G300 005 G300 05 G50 0 G50 220 G50 330 G0 06 G0 07
Dupline Building Automation Components Light Switches Digital Output Modules Types G20 G0 0 G0 3 G330 555 66 x 66 x Light switch with built-in bus interface and individually adressable pushbuttons and LED s. OPUS design 2 x 2 x 0 Universal light switch interface for use with standard mechanical light switchs. Ultrasmall size for decentral installation behind standard light switches. 26 x 29 x 7 Decentral relay module with x SPST relay for control of lights. Compact regular, with solid cables. For decentral installation. Central relay module with x SPST relay for resistive loads. DIN-rail, H x Pushbuttons x LED indicators x Contact input x 3A/250 VAC relays Inrush current: <30A x 6A/250 VAC relays Inrush current: <30A 5 = 5 VAC Max length of input wires 20 cm. Recommended minimum load 00 ma / 2 V. -5 C to +50 C Total module load maximum 32 A. Grey colour White colour G20 06 G20 07 G0 0 G30 3 G330 555 CARLO GAVAZZI Automation Components Specifications are subject to change without notice. 9
Dupline Building Automation Components Digital Output Mod. Dimmer Modules Digital Input Modules Types G330 29 G2 3 G0 02 G20 0 Relay module with Interlocking relay for control of 2 rollerblind motors. 72 x 72 x 5 Dimmer module with scenario (6 memory) functions. 26 x 29 x 7 Decentral voltage input module for use with external PIR sensors. Compact regular with solid cable. 66 x 66 x 23 Alarm input module for use with external sensors in windows, doors etc. Open PCB with standard alarm junction box enclosure. 5 A 250 VAC or 0.25A/250 VDC loads. 5 = 5 VAC 2 = 5-30 VDC x 20 to 600 W 230 VAC loads. Powered through the Dupline network or from external 0 to 30 VDC supply. x voltage input (90 to 265 VAC) x Contact/NPN inputs Powered through the Dupline network or from external 0 to 30 VDC supply. -2-0 C to +5 C Negative or positive phase angle dimming. -2 Support Dupline 3-wire power concept. G330 29 G2 3 72 G0 02 G20 0 700 0
Dupline Building Automation Components Analog Sensors Digital Sensors Types G3 20 G6 00 G9 00 G90 27 3 x 0 x 3 Light intensity sensor for indoor and outdoor use. Direct wall mounting. x x 37 Temperature sensor for indoor use. ELKO 67 x 35 x 5 Temperature sensor for outdoor use. Flat pack sensor housing. 0 x 55 x 57 Passive infrared sensor (PIR) for detection of movement of persons. Used for intruder alarm or light control. Direct wall mounting. x Analink Range: 0. to 00000 LUX x Analink Range: -30 C to +60 C x Analink Range: -30 C to +60 C x Digital signal when PIR is actived. IP -0 C to +60 C -bit resolution -30 C to +5 C -55 C to +5 C -bit resolution -30 C to +5 C -55 C to +5 C -bit resolution IP 0 - -30 C to +70 C Maximum range 0 m G3 20 G6 00 G9 00 G90 27 CARLO GAVAZZI Automation Components Specifications are subject to change without notice.
Dupline Building Automation Components Digital Sensors Types G90 26 G90 227 G90 0 G60 5 70 x 0 x 6 Water Sensor for detection of water on the floor in a building. Direct wall mounting Ø 0 x 0 Smoke Detector for detection of smoke in a building. Direct mounting on ceiling. 55 x Magnetic proximity Sensor. Used to monitor the state of windows etc. Ø or Ø housing. 55 x Inductive Sensor. Used to monitor the state of doors etc. M standard alarm 2 x signal always activated when sensor is cennected. x digital signal when water is detected. 2 x digital status signal when sensor is connected. x digital signal when smoke is detected. x digital signal when activated by magnet. x digital signal when activated by metallic object. -2 IP 2-5 C to +0 C Uses a optical detection principle. -2-25 C to +70 C -30 C to +0 C G90 26 G90 227 G90 0 G90 0G G60 5 G60 5-2
Dupline Building Automation Components Remote controle Modules Display Modules Types G05 556 G5 5530 GTD50 GTS377S 55 x 0 x 22.5 IR Remote control transmitter for control of lights, dimming roller blinds etc. Handheld 0 x 0 x 37 IR Remote control receiver. Direct wall mounting 77 x 6 x LCD Text Display with 2 rows x 20 characters Panel mounting 3 x 7 x 57 5.7 LCD Touch Screen with 6 colours STN Display. Resolution: 320 x 20 Panel mounting Powered by x.5 V AAA batteries Digital and Analink. User-defined text messages linked to Dupline channels. Read-out to Analink values Dupline control via front keys. -32 VDC Digital and Analink. Alarms, dynamic link to bitmap files and text, customisable touch buttons, history buffer. 2-27 VDC -0 C to +5 C Designed solely for use with G5 553 IP 2-0 C to +5 C Designed solely for use with G05 556 IP 65 (front) -20 C to +60 C IP 65 (front) -20 C to +60 C G05 556 G5 553 GTD50 GTS377S CARLO GAVAZZI Automation Components Specifications are subject to change without notice. 3