Converter Box Data Sheet

Similar documents
Manual Fiber Optic Interfaces

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

Manual EM260 with Volume Corrector EK220/260/280

Accessories / 7XV5461

Industrial Media Converters

MED102A. Industrial Serial to Single-mode Fiber Converter

ICF-1150 Series Quick Installation Guide

Accessories / 7XV5662

TCF-142-RM Series Hardware Installation Guide

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Introduction. General Ratings

RTU560 Connections and Settings DIN Rail RTU 560CIG10

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

RTU560 Remote Terminal Unit Connections and Settings

SCB-C08 USB to RS232/422/485 Converter

Fixed mount CCD bar code reader NFT Specification Ver. 1.0

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

GT- IRDM-9603 Product description Rev. 2 17/06/2014

L-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH

Industrial Serial Device Server

NM-251D-DTM. Datum Generator - Data Multiplier User Guide V1.00

Manual Industry Interfaces

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Product data sheet accessories control and regulation Accessories AIRWIN

INSTRUCTIONS. FSD301A and FSD302A FIBER SUBSYSTEM DATALINK

ADA User manual ADA RS-232 to Multidrop Fiber Optic Converter. 1 io_ada-7210_en_v3.17. Copyright CEL-MAR sp.j.

Features and Benefits. Certifications

TCP. Control and Protection Terminal Data sheet

DATA CONNECT ENTERPRISE

Installation and Configuration Quick Guide GoRugged M1000 MP

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

Installation Guide Serial Interface T942SI

Select a Data Communication Interface

Moxa TCC-100 Series User s Guide

UniMod Intelligent Communication for all Metering Application

W&T Manual Interface modules W&T

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Wireless Solutions. 5.1 Wireless LAN & Wireless Modem. Wireless Modems. Intelligent GPRS/GSM Modules. Mini-Programmable Automation Controllers

Moxa TCC-100 Series Hardware Installation Guide

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Time Counters mini "h", DC Version

Fiber Optic Selector Guide for PLC & Serial Communication Networks

Solenvis SL80 Pulse to M-Bus Converters

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

ICF-1150 Series Quick Installation Guide

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

Compact Intercom Server GE 100

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

205 CPU NETWORK ADAPTER F2-UNICON

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

CS485. User s Manual. Version ZYPEX, Inc.

U1602, U1603 ENERGY CONTROL SYSTEM

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Extract from the online catalog

NM-251D-INC. Dual Axis Inclinometer Output Format converter User Guide V1.00. Introduction

USB-COM Plus ISO (USB-COMi SI-M)

RS-232 Industrial Media Converter

Single Channel FM Video Transmission System 850 nm Multimode Low Profile

Manual and Protocol Description

VGA KVM Extender CATVision 7.2

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

ISOLATED RS-232 TO RS-422/485 CONVERTER

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem

Media Converters. Media Converters. Product Selection Guides

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Integrity Instruments

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

Access Terminal IF-800

Introduction. Technical Support:

VGA-KVM Extender CATVision 7.6

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Interface Module XC Level Converter / User Manual

MGate MB3170/MB3270 Quick Installation Guide

Connector and Cable Specifications

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

ParCon and PosCon line sensors

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Fibre Modem - Single-mode

SIU-218 and SIU-2218

TM221CE24R controller M IO relay Ethernet

XT-9100 Technical Bulletin

VGA KVM Extender CATVision 7.4

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

TM221CE40R controller M IO relay Ethernet

Connector and Cable Specifications

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

RS-232 Fiber Link Card System

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Installing the DX LCD Display

Transcription:

Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to plug in the following modules as required: M-Bus-interface: (passive or active) for connection to the M-Bus cable. The length of the cable can go up to 10km, depending on the cable and the number of devices connected to it. For small M-Bus systems the converterbox can also be used as mini-master (M-Bus-Repeater) if not more than 20 devices are connected. RS232-interface to connect a modem or a PC. The length of the cable must not exceed 15m. RS485-interface (2 or 4 wires) for connection to a PC. The length of the cable must not exceed 1,2km and the maximum number of devices is limited to 32 within the bus segment. 20mA/CS-current loop (passive or active): for connection to a PC. The length of the cable must not exceed 1km. Up to 3 devices can be connected to the 20mA bus segment. Fiber-optic cable (820nm, multimode) with ST- or SMA- Connector. RS232-interface for Elster EK88 / EK260 / DL240 The following conversions are available: to from RS232 20mA (passive) 20mA (active) M-Bus (passive) 3) M-Bus (active) 4) RS485 Fiber-optic RS232 1) 20mA (passive) 2) 20mA (active) 2) M-Bus (passive) 3) 2) M-Bus (active) 4) 2) RS485 1) 2) 2) 2) 2) 2) 2) Fiber-optic 2) 1) The interfaces for RS485 (2 wires) are halfduplex-interfaces which need a control signal to switch between receive and transmit. The RTS-signal of the RS232-interface is used for this purpose. If there is no RTS-signal available, the change between reception and transmission is initiated by a timer. The time constant is adapted to the needed baud rate. 2) With no control signal available for the RS485-Module to switch from reception to transmission, a timer is used with a delay (ca. 36ms for 300 baud). 3) Put the M-Bus (passive) module in the left slot (interface 1) only! Exception: converter box with fiber-optic: M-Bus (passive) module in the right slot (interface 2). 4) Put the M-Bus (active) module in the right slot (interface 2) only!

Page 2 from 6 Housing The housing can be wall mounted; it has a terminal compartment made out of plastic and is built according IP52. Segment format for M-Bus The number of devices which can be connected to the repeater and the structure of the segments is defined by the type of cable or wiring and the baud rate. Indication elements Six LEDs indicate the status of the interface modules: 2 green LEDs indicate the available power supply of 5V for each interface. 2 yellow LEDs for transmission (TxD, RxD) and 2 yellow LEDs for control signals (RTS, CTS). They indicate the signals of the relevant interface. Using the converter box as mini-master only the data indicator LEDs TxD and RxD are valid. The yellow LED (RxD) of interface 2 indicates a data request by a PC for devices connected to the M-Bus. The yellow LED (TxD) of interface 1 indicates data from the device to the PC. There is an additional red LED on the module of the M-Bus Mini-Repeater (active). During power up it is switched on for a short time, afterwards it is only glowing with low volume under standard conditions. If the current of the M-Bus exceeds the limit of 30mA, the LED is glowing brightly. If the currents exceeds 100mA, the voltage of the M-Bus is cut-off and the red LED remains switched on. Then the Mini-Repeater tries periodically to switch on the voltage again, but this is only successful, if the current demand is lower than the current limit. Power supply The converter box has got an own power supply (230VAC or 115VAC) with a fuse. Optionally is a version for 24VDC availably. M-Bus: The Mini-Repeater is used in small M-Bus-Segments to improve the signal quality or is used as Master. Up to 20 devices/terminals can be powered with an individual current demand of up to 1.5mA. The two interface- slots of the converter box are equipped with a selectable interface module and a repeater module with integrated M-Bus interface. Data transfer for M-Bus The activation of the data transfer of all M-Bus repeaters is initiated by changes in voltage or current. Two directions are possible: From the repeater to the devices by voltage decrease (ca. 12V). From the devices to the repeater by request of a higher current ( 11mA to 20mA). This type of data transfer enables a secure data exchange also in an environment with many disturbances. Hardware handshake For hardware handshake set the RTS and CTS jumper (needed for 2 wires conections).

Page 3 from 6 Technical data: Housing: Wall-mounted housing according to DIN 43861-2 Degree of protection: Dimensions: Nominal voltage: Power consumption: Fuse: Display: Interfaces: Baud rate: IP52 (IEC) 105mm 179mm 72mm (W H D) 230VAC 15%, 50/60Hz; optional 115VAC or 24VDC ca. 9VA 100mA, slow (for 230VAC) 160mA, slow (for 115VAC) or 500mA, slow (for 24VDC) 6 LED s RS232 20mA/CS active or passive M-Bus active (max. 20 devices à 1.5mA), right slot (interface 2) only M-Bus passive, left slot (interface 1) only; exception: fiber-optic RS485 (2 or 4 wires) Fiber-optic (820nm) with ST- or SMA-connector 300 to 9600 Baud Data format: 7E1, 8N1, 8E1,... Transmission protocol: Temperature range: Dimensions All protocols are possible (transparent data transmission) -25 C to +60 C (operational) -40 C to +90 C (storage temperature) View: rear Terminal cover (sealable screws) View without the terminal cover

Page 4 from 6 Terminal assignment The valid terminal connection is always displayed at the terminal block of the converter-box!

Page 5 from 6 Terminal assignment for RS485 (4 wires) Example with two converter boxes:

Page 6 from 6 Terminal assignment for fiber-optic Using the fiber-optic connector (for fiber-optic transmission), the unit can be read via 820nm optical fiber (glass). Wave length: 820nm Transmitter (TD): transmits light Receiver (RD): receives light Cable code: 50/125 m, 62,5/125 m (recommendation), 100/140 m or 200/230 m HCS (multimode) Connection code: ST or SMA Baud rate: 300 to 9600 Baud Cable length: up to 2,7km (depends of the cable) The idle condition of the fiber-optic transmission line has to be configured with the jumpers between the two connector elements: Idle condition Light off : the jumper must be placed on pins 1/2 (delivery condition) Idle condition Light on : the jumper must be placed on pins 2/3 The upper row of pins determines the condition of the receiver (RD), the lower row of pins sets the condition for the transmitter (TD). Jumpers must be placed in both rows! Example with two converter boxes: Subject to change without notice!