Model VC-SHIELD Shield Box

Similar documents
VC200 Mobile Phone Tester Please Read before Use

User s Manual Power Supply IM E. 5th Edition

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

VC3300 Wireless Communication Tester Please Read before Use

User s Manual Model PBL250 Logic Probe IM E. 3rd Edition

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Optional Lens User s Manual

Optional add-on cassette Attachment Instruction manual

Analog Input/Output Modules

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

POWER SUPPLY UNIT PSU-3

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

Powergate3+ Decoder. Instruction manual and user s guide

Motorized Curtain Tracks Progress 50 Motor Set

Powergate³ User. Instruction manual and user s guide

NIR Moisture Analyzer KB-30

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Model GX70SM. Wireless Input Unit First Step Guide (Notes about Using This Product) Revisions IM 04L57B01-02EN. (this manual) GS 04L57B01-01EN.

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

SUBWOOFER SYSTEM YST-MSW10

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Smartphone Photo Printer

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Please read this guide before using the printer

Mag EraSURE TM Professional Value Product Manual

INSTRUCTION MANUAL GPIB TO USB ADAPTER GUG-001 B

V-Switch 3 User Guide

RS232C/RS485 Data can be easily monitored by LAN

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM E FR20/30 SERIES DSU-FR20/30 EMULATOR MB HARDWARE MANUAL

Precision Health Scale Model UC-321P

PA Series. Available in 6.0MP and 8.0MP

TOS-SN-1 Extended Panel Operation Manual

Smartphone Photo Printer Item No

Digital Overhead Stirrer

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

Stereo Turntable System

IR Varifocal IP66 Weatherproof Cameras

Operation Manual for VXC4000 VXC4000 V

PX Series Balances. Quick Start Guide. Please download the user manual from

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

APRC90AT manual Table of contents

7032 Digital-Analog Multimeter

5.6 Color Rear View Safety System Installation & Operation. RV56 (Includes MO56 monitor & CA56 camera)

NS-AP8600/SPS-8600 HOME CINEMA SPEAKER PACKAGE OWNER S MANUAL CONTENTS

Auto-Cutter (JM98901) User's Manual

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Antenna Distributor ORDERCODE D1444

English User s Manual

User Manual. Bedal 3S. Welltec-UM-Bedal_ Rev.03

Thin clients JC500X - 1 Reference guide

Preface. Essential Safety Precautions

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

Manual. DP-6 S Dimmer Pack

Manual. Dimmer DMD-12-2

FleetPhone. Installation guide. The mobile satellite company

Instruction Manual. English Version 2.0

Universal AC Power Source + AC Power Analyzer

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Instruction Manual LAN CABLE HiTESTER. March 2013 Revised edition A H

Chapter 2: Disassembly

DOT MATRIX PRINTER SP6000 SERIES

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

IPCB42501 / IPCB42551

Thank you for purchasing a Canon product.

THERMAL PRINTER PR-TB4

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

Integrated video camera ImageCam USER S INFORMATION. Camera control panel

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

A120 A W/240W PA Mixer-Amplifier 70V/100V

5 B&W Rear View System Camera

aframe electrorganic percussion Quick Start Guide

Camera Control Box. Instruction Manual CCB-WD (1)

Agilent U2941A Parametric Test Fixture

Quick Start Guide Notion Ink Design Labs Pvt. Ltd. 1

DS-1H05 Ethernet-over-Coax Extender. User Manual

Phone Setup. Phone Hardware Installation. Install the Phone Battery. Phone Hardware Installation, page 1 Phone Configuration Tasks, page 11

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

Available in 2.0MP, 4.0MP and 8.0MP variants

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

EcoXBT. Models: GDI-EGBT User Guide

User Manual GBS-1269BT. Body Scale 4.0. version:1.0. Distributed by: Informed Clinical Sciences Corporation 1 Joy Street, Boston, USA MA 02108

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) TES-1326S INSTRUCTION MANUAL

User Manual UHF SYNTHESIZED WIRELESS TRANSMITTER

Set Compact system JAM

User s Manual M EN

Thermal Infrared Camera ARTCAM-640P-THERMO INSTRUCTION BOOKLET

Thermal Infrared Camera. ARTCAM-THERMO series INSTRUCTION BOOKLET

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

Users Manual STP-103II. Thermal Printer Rev

PAR-WT50R-E PAR-WR51R-E

User Guide. ICP 300 In-Cab Printer. Operation

Transcription:

User s Manual Model 733062 VC-SHIELD Shield Box Yokogawa Electric Corporation IM 733062-01E 2nd Edition

Introduction Thank you for purchasing the 733062 VC-SHIELD Shield Box. This user s manual contains useful information about the shield s functions and operating procedures and lists the handling precautions of the VC-SHIELD. To ensure correct use, please read this manual thoroughly before beginning operation. Checking the Contents of the Package In addition to the VC-SHIELD, the following standard accessories are included. When you open the package, make sure that all contents are present and undamaged. If some of the contents are not correct, or if any items are missing or damaged, contact the dealer from whom you purchased them. VC-SHIELD Check that the MODEL given on the name plate on the rear panel is 733062. Standard Accessories RF cable (N-TNC type) 1piece (B8014VC) User's Manual 1piece (This manual, ) Conventions Used in This Manual Improper handling or use can lead to injury to the user or damage to the instrument. This symbol appears on the instrument to indicate that the user must refer to the user s manual for special instructions. The same symbol appears in the corresponding place in the user s manual to identify those instructions. In the manual, the symbol is used in conjunction with the word WARNING or CAUTION. WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and precautions that can be taken to prevent such occurrences. CAUTION Calls attentions to actions or conditions that could cause light injury to the user or damage to the instrument or user s data, and precautions that can be taken to prevent such occurrences. Revisions 1st Edition: February 2006 2nd Edition: March 2006 2nd Edition: March 2006 (YK) All Rights Reserved, Copyright 2006 Yokogawa Electric Corporation 1

RF IN/OUT CABLE USB UE POWER MODEL SUFFIX NO. Made in Japan Names of Parts Front Side Handle Lever(used to open the lid) Rear Side RF IN/OUT CABLE ANT UE POWER USB Name Plate SERIAL NO. 8S-2513-20 USB Connector Used when connecting the mobile phone installed inside the VC-SHIELD to an external device via the USB UE POWER Connector Used to supply power to the mobile phone or measure the consumption current RF IN/OUT Connector Connects the mobile phone tester and the shield box (CABLE: Used when connecting a cable to make measurements ANT: Used when coupling antennas to make measurements) Inside RF IN/OUT Connector Used when connecting a cable to make measurements (Connects the mobile phone and the shield box) USB Connector Used to connect the mobile phone and an external device via the USB UE POWER Connector Used to supply power to the mobile phone Mobile phone holder Slide lever Used to slide the mobile phone holder 1 2 3 4 Slide position Positioning block 2

Handling Precautions General Handling Precautions Do not place objects other than the mobile phone inside the shield box. Be sure to close the cover of the shield box. Never place other instruments or objects containing water on top of the instrument, otherwise a breakdown may occur. Do not apply shock to the input/output connectors. To wipe off dirt on the case, use a dry, soft, clean cloth. Do not use volatile chemicals since this might cause discoloring and deformation. When carrying the box, close the lid and hold the handle on the side. CAUTION The materials used inside the shield box may deform or alter when they come in contact with hot objects. Installation Installation Conditions Install the shield box in a place that meets the following conditions. Flat, even surface: Install the shield box with the correct orientation on a stable, horizontal surface. Ambient temperature: 5 to 35 C Ambient humidity: 20 to 80% RH (no condensation) 3

Do Not Use in the Following Places In direct sunlight or near heat sources. Where an excessive amount of soot, steam, dust, or corrosive gas is present. Near strong magnetic field sources. Near high voltage equipment or power lines. Where the level of mechanical vibration is high. Opening/Closing the Lid Pull the front lever toward you to open the lid. CAUTION Before opening the lid, remove objects placed on top of the lid. The lid may fly open. When opening the lid, be careful not get in the way of the opening lid (such as your face and hands). When closing the lid, be sure not to get your fingers caught between the lid and the box. 4

MODEL SUFFIX NO. Made in Japan 8S-2513-20 Connecting Cables Connecting the Mobile Phone Tester and VC-SHIELD Connect the RF cable *1 (Part No.: B8014VC) that comes with the shield box to the RF IN/OUT connector (CABLE or ANT *2 ) on the rear side. Connect the other end of the cable to the RF IN/OUT connector on the mobile phone tester rear panel. *1 If the RF IN/OUT connector of the mobile phone tester is of type N, purchase the following RF cable made by YOKOGAWA. Model 739821 (type N cable, 1 m) *2 When connecting a cable to make measurements: Connect to CABLE When coupling antennas to make measurements: Connect to ANT VC200 Note When cables other than accessories or Yokogawa's specified RF cable are used, specifications, such as a shielding performance and the operating frequency range, may not be achieved. Connecting the Mobile Phone and VC-SHIELD When connecting a cable to make measurements, connect the RF IN/OUT (CABLE) connector inside the shield box to the mobile phone with a coaxial cable. The coaxial cable is to be provided by the user. 5

Installing the Mobile Phone When coupling antennas to make measurements, install the mobile phone by considering the relative positions of the antenna of the shield box and the built-in antenna of the mobile phone. 1. Press the mobile phone against positioning block 1. Positioning block 1 (Cut at a slant to keep flip mobile phones from falling over) <Side View> 2. To fix position of the mobile phone in place, press the mobile phone against positioning block 2. Positioning block 2 <Top View> 3. Gently press the mobile phone against the nonslip rubber mat at the bottom to fix the mobile phone in place. Positioning block 2 Nonslip rubber mat Slide lever Positioning block 1 Moving the Mobile Phone Holder 4. When coupling antennas to make measurements in a reproducible fashion, operate the slide lever in the direction of the arrows shown below, and fix the position of the mobile phone to any position between slide position 1 and 4. 1 2 3 4 2 3 4 Note The relationship between the slide positions of the mobile phone holder and the RF power loss* by the antenna coupling vary depending on the mobile phone model and installation direction. * Compensation is possible by setting the RF loss compensation on YOKOGAWA's VC series testers. 6

Notes Concerning Measurements When coupling antennas to make measurements, several dbs of error may result in the measured values due to the effects of coupling loss of the antenna and mobile phone. If you wish to accurately measure parameters such as the transmission power of the mobile phone, connect the mobile phone and the shield box with a coaxial cable. Do not insert foreign objects between the shield box and the lid. The shield box may break or may not achieve the shielding performance of the specifications. Check that there is no deformation or damage inside and outside the shield box. If the shield box is deformed or damaged, the shielding performance of the specifications may not be achieved. Recommended Replacement Parts The one-year warranty applies only to the main unit (starting from the day of delivery) and does not cover any other items nor expendable items (items which wear out). Contact your nearest YOKOGAWA dealer to have parts replaced. Parts Name Damper Gasket Gasket Gasket Part No. B8014GN B8014VF B8014VG B8014VH 7

Shielding Performance Frequency range Shielding Performance 800 M to 2500 MHz 60 db or higher Antenna coupler Frequency range 800 M to 2500 MHz Antenna coupling loss 30 db or less * Coupling impedance Maximum allowable input power Connector type 50 Ω 0.25 W N-type connector (rear side, ANT connector of RF IN/OUT) * Varies depending on the shape of the mobile phone, antenna position, and the holder slide position. RF IN/OUT Connector(CABLE) Frequency range Coupling impedance Insertion loss Connector type 800 M to 2500 MHz 50 Ω 0.3 db or less N-type connector (rear side) SMA connector (inside) USB Connector Wiring Connector type Straight connection B type receptacle (rear side) A type receptacle (inside) Mobile Phone Power (UE_POWER) Connector * Maximum allowable voltage 5 V Maximum allowable current 2 A Connector type D-sub 9-pin plug (rear side) D-sub 9-pin receptacle (inside) * This connector is used to supply power to the mobile phone or measure the consumption current. 8

Pin Assignments D-sub 9-pin plug (rear side) Pin No. 1 2 3 4 5 6 7 8 9 D-sub 9-pin receptacle (inside the box) Pin No. 1 2 3 4 5 6 7 8 9 Inside (D-Sub 9-pin receptacle) Pin No. Signal Name 1 Power supply for the mobile phone (+) Connect to the positive electric potential of the mobile phone s battery terminal. 2. Power supply for the mobile phone (-) GND Connect to the negative electric potential of the mobile phone s battery terminal. 3 Reserved Do not connect anything. 4 Reserved Do not connect anything. 5 GND 6 Power supply for the mobile phone (+) Connect to the positive electric potential of the mobile phone s battery terminal. 7 Power supply for the mobile phone (-) GND Connect to the negative electric potential of the mobile phone s battery terminal. 8 Reserved Do not connect anything. 9 GND 5 4 3 2 1 9 8 7 6 Rear Side (D-Sub 9-pin plug) Pin No. Signal Name 1 Power supply for the mobile phone (+) Connect to the positive electric potential of the mobile phone power supply. 2. Power supply for the mobile phone (-) GND Connect to the negative electric potential of the mobile phone power supply. 3 Reserved Do not connect anything. 4 Reserved Do not connect anything. 5 GND 6 Power supply for the mobile phone (+) Connect to the positive electric potential of the mobile phone power supply. 7 Power supply for the mobile phone (-) GND Connect to the negative electric potential of the mobile phone power supply. 8 Reserved Do not connect anything. 9 GND 9

General Storage conditions Temperature 20 to 60 C Humidity 20 to 80% RH (no condensation) Operating conditions Temperature 5 to 35 C Humidity 20 to 80% RH (no condensation) Storage altitude 3000 m or less Operating altitude 2000 m or less External dimensions 280 (W) 140 (H) 320 (D), excluding the handle and projections Weight Installation position Standard accessories Safety standards EMC standards Approx. 3.4 kg Horizontal RF cable (N-TNC, 0.7 m)1 piece User s Manual 1 piece (this manual) Safety and EMC standards are specified in combination with the VC100/ VC200/VC3300. For details on the complying standards, see the VC100/ VC200/VC3300 User s Manual. External Dimensions (288) 5 278 5 Unit: mm (28.53) (168.5) 24 140 4.5 320 (356.8) 8.3 Unless otherwise specified, tolerance is ±3% (however, tolerance is ±0.3 mm when below 10 mm). 10