AUTHORIZED COMPONENTS FOR FMS 5.1 AND NEWER SOFTWARE

Similar documents
TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

PORTACOUNT PRO/ PORTACOUNT PRO+ MODEL 8030/8038 RESPIRATOR FIT TESTERS

Application Note. Configuring a Phoenix Bus Coupler to communicate Modbus/TCP with an MPiec Controller

PORTACOUNT PRO 8030 AND PORTACOUNT PRO RESPIRATOR FIT TESTERS

Facility Monitoring System Design Recommendations

REAL-TIME DUST AND AEROSOL MONITORING

iologik E1200H Series

INTERFACES. CLASSIC CONTROLLER DATA SHEET page 1/4. Unpacking. Diagram. Figure 1: G4LC32SER Physical Layout

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

INSTALLING THE FMS 5.3.x SOFTWARE

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description

Part Numbers SNAP-PAC-S1 SNAP-PAC-S1-FM SNAP-PAC-S2

INTERFACES TRADITIONAL PC ADAPTER CARDS. DATA SHEET page 1/6. Description

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description

Product Application Note. MP2000iec Address Mapping between a Phoenix MII BK unit and an MP2000iec controller. Applicable Product: MP2000iec

BRAIN BOARDS DEVICENET 16-CHANNEL DIGITAL. DATA SHEET page 1/7. Description

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description. Part Numbers

PB IL 24 BK DIO 16/16

8030 and Respirator Fit Testing. Respirator Fit Testers. Firmware Update Instructions Version 2.4. Quick Installation Guide

Ethernet I/O Modules: ADAM-6000

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

SNAP Controllers SNAP-LCE

ACHIEVE A BETTER FIT MAXIMIZE SAFETY WITH QUANTITATIVE TESTING ANY N95, A NUMERIC MEASURE OF FIT AND A MORE PRODUCTIVE YOU MODEL 8040 MODEL 8048

CLASSIC DATA SHEET page 1/5

ICP DAS DeviceNet Total solutions

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

M4SARC Network Interface Card

Redundant System Redundant System P9-1-1

CONTROLLERS. ISA DATA SHEET page 1/4. Description

IL ETH BK DI8 DO4 2TX-PAC: IP ASSIGNMENT & WATCHDOG

3: Networking Options

E2000 Series Active Remote I/O

Ethernet I/O Modules: ADAM-6000

Features and Benefits. Certifications

MP211 HARDWARE MANUAL

Distributed Control I/O System ADAM-8000 Series

Features and Benefits. Certifications

Interface Adapter Card. Part Number

JetI/O 6500 Demo Box

Switch and Status LEDs for System Controller 2

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

PCI-AC5, PCIe-AC5, AC5, and G4AC5 Adapter

1.2. All new meters will be one of the following meter forms: 2S for single-phase, and 9S for multi-phase.

M2M OPTOGSM I/O DATA SHEET. Description

Controllers. Compact controller system - Easy Automation Product overview 518. Controllers

Advancing Serial-to-Ethernet Technology

CPU ONE PLC PLC USER S MANUAL

Do-more H2 Series PLC System Specifications

I/O MODULES G4 ANALOG INPUT. DATA SHEET page 1/4. Description

User Manual Hardware and Firmware Manual for the Ethernet/Inline Bus Coupler FL IL 24 BK-B-PAC Designation: Order No.: FL IL 24 BK-B UM E

IBS IL 24 BK RB-T-2MBD

NX1 Machine Automation Controller Continue to pursue productivity

RACKS. CLASSIC STANDARD DATA SHEET page 1/4. Description

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

TB20. DISTRIBUTED FIELDBUS I/O SYSTEM

UA-5200 IIoT Communication Server

ADAM-6000 Series. Features. The Path to Seamless Integration. Why Smart I/O? Why Web I/O? Control Strategy Moves to Field Devices. Why Mixed I/O?

OPC-Solutions from Softing. Haar, Peter Jüngling V3.0

RTU300 SERIES HARDWARE MANUAL

HRM-0800 Instruction Manual

Bluetooth Communications for the Model 9565 VELOCICALC Meter and Model 7575 Q-TRAK Monitor Application Note TSI-150

Reliable Environmental Monitoring Systems by Design

ThingsPro Software User s Manual

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

PMA Rail Line. Product Brochure.

Agilent U2600A Series USB Modular Isolated Digital I/O Devices. Data Sheet

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

Predictive Software for Facilities Management

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

BRAIN BOARDS BRICK ANALOG INSTALLATION NOTES

NetBiter I/O Extender User Manual

STTS V memory module temperature sensor. Features

Lighting Control Panel

DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for TPSD/A36D Chargers with S2A-205T Option 21P or 57T or 57U. Setup Instructions

iologik 2500 Series Quick Installation Guide

POWERSIGHT LASER DOPPLER AND PHASE DOPPLER MEASUREMENT SYSTEMS

iologik 4000 Series (M) Modules

SIL certified safety for people, the environment and machinery Overview of PROGNOST -SILver safety analyses... 6

Classic G4 16-Channel Rack. Classic G4 16-Channel Rack. Features. Description. Specifications. Part Number

BRAIN BOARDS BRICK ANALOG. DATA SHEET page 1/7. Description

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

RS-485 I/O Modules: ADAM-4000

Communication Protocols for Opto 22 Products

Serial to Ethernet Converter

Jazz-J. Jazz. Features:

BRAINS CLASSIC/MISTIC 16-CHANNEL ANALOG. DATA SHEET page 1/10. Description

Jazz-J. Jazz. Features:

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

CLASSIC STANDARD DIGITAL DATA SHEET page 1/4

Netbiter EC300 Series

UPort 1200/1400/1600 Quick Installation Guide

Connect Different Protocols It s Quick, Easy, and Reliable

General Specifications

Transcription:

AUTHORIZED COMPONENTS FOR FMS 5.1 AND NEWER SOFTWARE APPLICATION NOTE CC-112 (A4) (9/22/2017) Rev B Introduction This application note details the authorized hardware and software components that TSI supports for use with FMS Software. Hardware includes particle counters, analog inputs, digital inputs, and digital output devices. FMS Software drivers are written for these devices. TSI cannot support devices that are unlisted in this document, because there are no drivers. Please contact TSI for assistance and questions regarding alternate hardware, interfacing components, and system topology. Particle Counters In general, TSI supports TSI particle counters. However, not all TSI particle counters have drivers in FMS. Only the particle counters listed below are supported. Model Number and AeroTrak Remote Particle Counters Models 7201/7301/7501/7310/7510 series AeroTrak Remote Particle Counters with special size channels via RS485 AeroTrak Remote Particle Counter with Integrated Pump Models 6510 and 6310 AeroTrak Portable Particle Counters Models 9310-02, 9510-02, 9350-01, 9550-02, 9500-01 AeroTrak Handheld Particle Counters Models 9306-XX AeroTrak Remote Particle Counter Model 7110 (both RS485 and TCP/IP) AeroTrak Portable Particle Counter Model 9110 (both RS485 and TCP/IP) TSI M-32 Manifold (for use with AeroTrak Portable Particle Counters and Remote Particle Counter with Integrated Pump) BioTrak Real-Time Viable Particle Counter Model 9510-BD AeroTrak Phase 1 Portable Particle Counters Models 9310-01, 9510-01, 9350-01, 9550-01 FMS Driver Name TSIRemoteTCP TSIRemote485 TSIRemote7000SP TSIRemoteWithPump485 TSIRemoteWithPumpTCP TSIAeroPlate6TCP (for interrupted monitoring) TSIAPC TSIAPC TSIAPC TSIAPC_Manifold TSIAPC_BioTrak TSIAeroTrack6TCP TSI, TSI logo, BioTrak, and AeroTrak are registered trademarks of TSI Incorporated.

Model Number and Lighthouse Remote 5104 (consult with TSI prior to integration) FMS Driver Name GenericSolair PMS IsoAir 310P (0.3, 0.5, 1.0, 5.0 µm 1.0 cfm) PMS Airnet II 201-4 (0.2, 0.3, 0.5, 1.0 µm 0.1 cfm) PMS Airnet II 301-2 (0.3, 0.5 µm 0.1 cfm) PMS Airnet II 301-4 (0.3, 0.5, 1.0, 5.0 µm 0.1 cfm) PMS Airnet II 310-4 (0.3, 0.5, 1.0. 5.0 µm 0.1 cfm) PMS Airnet II 501-2 (0.5, 5.0 µm 0.1 cfm) PMSAirnetTCP PMS Airnet II 501A-2 (0.5, 1.0 µm 0.1 cfm) PMS Airnet II 501-4 (0.5, 1.0, 5.0, 10.0 µm 0.1 cfm) PMS Airnet II 510-2 (0.5, 5.0 µm 1.0 cfm) PMS Airnet II 510XR-2 (0.5, 5.0 µm 1.0 cfm) PMS Airnet II 510-4 (0.5, 1.0, 5.0, 10.0 µm 1.0 cfm) Page 2 of 5

Phoenix Contact I/O Devices FMS Software is configured to accept many Analog and Digital Input/Output (I/O) devices. Drivers are written for Phoenix Contact products to convert I/O devices into a communication protocol that FMS can read. For this, there is an FMS driver called PhoenixContact. This driver does not support all commercially available modules sold by Phoenix Contact only the modules detailed below are authorized and supported. When interfacing Phoenix Contact devices with FMS Software, the Modbus/TCP Bus Coupler is always needed. The other modules are then added to the coupler device. The order number is shown to help when sourcing these components directly from the Phoenix Contact supplier. Phoenix Model Number Phoenix Order Number Hardware version Firmware version compatible with FMS FMS Driver Name IL ETH BK DI8 DO4 2TX-PAC 2703981 Modbus/TCP Bus Coupler 4-Channel Digital Output and 8-Channel Digital Input 03 1.21, 1.3 IB IL AI 2/SF- PAC IB IL AI 8/SF- PAC IB IL 24 DO 4- PAC IB IL 24 DO 32/HD-PAC IB IL 24 DI 32/HD-PAC 2861302 2861412 2861276 2862822 2862835 2-Channel Analog Input Module 8-Channel Analog Input Module 4-Channel Digital Output Module 32-Channel Digital Output Module 32-Channel Digital Input Module Phoenix Contact Page 3 of 5

Other I/O Devices TSI FMS Software supports additional I/O devices as detailed below. Not all components from these brands are supported only those listed below are authorized. Please note that these I/O devices require integration with a Serial to Ethernet Converter, such as a Moxa device (used on numerous FMS projects). Please contact TSI for technical support regarding these devices and drivers. Adam Model 4015, 3-Wire 6-Channel RTD Adam Model 4017+, 8-Channel, only 4-20 ma A/D Adam Model 4052, 8-Chanel Digital Input (6 channels fully isolated, 2 share common ground) Adam Model 4068, 8-Channel Relay Output ICP CON Model 7017C, 8-Channel 4-20 ma A/D ICP CON Model 7067, 7-Channel Relay Out ICP CON Model 7067D, 7-Channel Relay Out with LEDs Wireless Temperature System FMS Driver Name Adam4015 Adam4017p Adam4052 Adam4068 Solo7017 Solo7067 Eltek Adam 4571, 1-Port RS-232/422/485 Serial Device Server MOXA N-port 5232, RS-485 to TCP (2 channels) No Driver needed MOXA N-port 5230, RS-232 to TCP and RS-485 to TCP Databases Current FMS Software comes with a copy of PostgreSQL, which is authorized and supported by TSI. Databases used previously in conjunction with FMS Software include MySQL and MSSQL. While FMS can interface with standard SQL databases, there are many issues impacting the performance of FMS and database administration of other SQL databases. Prior to committing to or implementing FMS with any other database other than the supported PostgreSQL shipped with FMS, contact TSI to discuss commercial and technical feasibility. Database Name Version PostgreSQL PostgreSQL 8.4 (32-bit) 9.X (32-bit) SQL Database (Current supported database works with all versions of FMS 5.0.7 and older) SQL Database (Used with FMS 5.1 and newer) Page 4 of 5

OPC UA Client/Server FMS 5 comes with OPC UA Client as standard since version 5.3.2, and with OPC UA Server as an option in FMS 5.4. FMS OPC Unified Architecture Client/Server is OPC Foundation Certified. It can connect to other certified OPC UA Servers to share data in real-time, the same applies to FMS OPC UA Client which receives real-time data from other OPC UA Servers. As OPC UA Client cannot receive real-time data from Classic OPC Server nor can OPC UA Server send real-time data to other Classic OPC Clients, TSI has tested and recommends the following software. It is required if connection to Classic OPC Client/Server is to be implemented in the FMS System. Recommended Software Software Name MatrikonOPC UA Wrapper for COM OPC Server Software Manufacturer Matrikon Download Link www.matrikonopc.com/opc-ua/products/opc-ua-tunneller.aspx Tested Version 1.2.4.6498 Software Name Allows FMS 5 OPC UA Client to connect to Classic OPC Server Matrikon OPC UA Tunneller Manufacturer Matrikon Download Link www.matrikonopc.com/opc-ua/products/opc-ua-tunneller.aspx Tested Version 6.0.0.7063 Software Name Manufacturer Download Link Allows Classic OPC Client to connect to FMS OPC UA Server, and acts as a Wrapper for FMS OPC UA Client to connect to Classic OPC Server Unified Automation UaGateway Unified Automation www.unified-automation.com/products/wrapper-and-proxy/uagateway.html Tested Version 1.4.5 Allows Classic OPC Client to connect to FMS OPC UA Server, and acts as a Wrapper for FMS OPC UA Client to connect to Classic OPC Server Page 5 of 5

Conclusion FMS is a flexible software package that can provide unique data management strategies to assist with risk reduction. Proper design and implementation of FMS and associated hardware is vital in realizing these strategies. System integrators and end customers must use standard, authorized components presented in this application note to ensure performance. Additional information on recommended FMS designs are detailed in TSI application note entitled, Facility Monitoring System Design Recommendations (CC-114). Contact TSI prior to implementing any design or integrating any hardware not authorized by TSI. TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 CC-112 Rev B (A4) 2017 TSI Incorporated Printed in U.S.A.