Datasheet - SLB 200-C04-1R

Similar documents
Datasheet - SRB 402EM-24V

Datasheet - SRB 301LC/B-24V

Datasheet SRB301ST 24V (V.2)

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - AZM 200SK-T-1P2PW

Datasheet - ZR Z

Datasheet - CSS 11-30S-D-M-ST

Datasheet - ZS Z

Datasheet - BNS ZG

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet AZM 161 Z ST1 AS RA

Datasheet - BNS ZG-ST

Datasheet - AZ 15 ZVRK

Datasheet - RSS 36-D-R-ST

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet - AZ 16-03ZVRK

Datasheet - AZ 16-02ZVK

Datasheet - AZ 15 ZVK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16ZVRK

Datasheet - AZ 16-02ZVRK-ST

Datasheet - ZR Z

Datasheet - AZ 15 ZVRK

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

E-STOP relays, safety gate monitors

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

XPSMCMDI Input expansion module with screw term

E-STOP relays, safety gate monitors

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Installation / Control Technique

E-STOP relay, safety gate monitor

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

E-STOP relays, safety gate monitors

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

E-STOP relay, safety gate monitor

Electronic timer CT-ERD.12

Contact expander modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PNOZ s1. Safety relays. Operating Manual EN-07

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

E-STOP relays, safety gate monitors

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Electronic timer CT-ERS.21

E-STOP relays, safety gate monitors

Electronic timer CT-AHD.22

Safe monitoring relays

E-STOP relays, safety gate monitors

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Two-hand control unit

E-STOP relays, safety gate monitors

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

E-STOP relays, safety gate monitors

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

E-STOP relays, safety gate monitors

Electronic timer CT-ARS.11

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

E-STOP relays, safety gate monitors

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

E-STOP relays, safety gate monitors

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RM35TF V AC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

E-STOP relays, safety gate monitors

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

PNOZ s9. Safety relays. Operating Manual EN-08

Transcription:

14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety contact 1 Signalling output (Minor differences between the printed image and the original product may exist!) Ordering details Product type description SLB 200-C04-1R Article number 101138897 EAN code 4030661281537 Approval Approval TÜV Global Properties Product name SLB 200-C Standards IEC/EN 61496-1/-2, EN 954-1 Compliance with the Directives (Y/N) Mounting snaps onto standard DIN rail to EN 60715 Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic Weight 350 g Start conditions Test button, Start button, on/off coding Start input (Y/N) Feedback circuit (Y/N) Start-up test (Y/N) No Automatic reset function (Y/N) Reset with edge detection (Y/N)

Response time Time to readiness 30 ms 300 ms Mechanical data Connection type Screw connection Cable section - Min. Cable section - - Max. Cable section 4 mm² Detachable terminals (Y/N) No restistance to shock 10 g / 16 ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm notice All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature - Min. environmental temperature 0 C - Max. environmental temperature +50 C Storage and transport temperature - Min. Storage and transport temperature 20 C - Max. Storage and transport temperature +80 C Protection class - Protection class-enclosure IP40 - Protection class-terminals IP20 - Protection class-clearance IP54 Air clearances and creepage distances To IEC/EN 60664-1 - Rated impulse withstand voltage Uimp 4.8 kv - Overvoltage category II To VDE 0110 - Degree of pollution 3 To VDE 0110 Electromagnetic compatibility (EMC) EMC rating conforming to EMC Directive Electrical data Type of actuation DC Switch frequency max. 10 Hz Rated operating voltage Ue 24 VDC ±20% Operating current Ie 180 ma Outputs Number of safety contacts Number of auxiliary contacts Number of signalling outputs Switching capacity 1 piece 1 piece - Switching capacity of the safety contacts max. 8 A - Switching capacity of the signaling/diagnostic outputs 500 ma Fuse rating - Protection of the safety contacts 4 A gg D-fuse Utilisation category To EN 60947-5-1 AC-15: 250 V / 2 A DC-13: 24 V / 2 A

Number of undelayed semi-conductor outputs with signaling function Number of undelayed outputs with signaling function (with contact) Number of delayed semi-conductor outputs with signaling function. Number of delayed outputs with signalling function (with contact). Number of secure undelayed semi-conductor outputs with signaling function Number of secure, undelayed outputs with signaling function, with contact. Number of secure, delayed semi-conductor outputs with signaling function Number of secure, delayed outputs with signaling function (with contact). LED switching conditions display LED switching conditions display (Y/N) Number of LED s 4 piece LED switching conditions display - The integrated LEDs indicate the following operating states. - RELAY, green: safety contact on - RELAY, red: safety contact off - RESTART, yellow: Waiting on authorised operation, RESTART button not yet pressed - ERROR, Orange: Internal or external fault (contactor contacts welded or test button [N.C.] not connected) Miscellaneous data Applications Safety light barriers Dimensions Dimensions - Width 45 mm - Height 84 mm - Depth 118 mm notice In order to set for the desired mode of operation and number of light barriers connected, remove the front cover of the safety monitoring module. As supplied all switches are in Position 1. The required functions can be selected by means of the internal DIP switches. DIP switch 1 - Position 1 with Contactor control - Position 2 without Contactor control DIP switch 2 - Position 1 with start/restart interlock - Position 2 without start/restart interlock DIP switch 3 - Position 1 Connection of 2 light barrier(s) - Position 2 Connection of 1 light barrier(s) Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. notice - Wiring example Monitoring up to 2 pairs of light barrier devices and the power contactors using the SLB 200-C safety monitoring module Test push button (T)

The test push button is connected to X13 and X14 in order to carry out a check of the light barrier monitoring function. The terminals X15 and X16 must be bridged. Contactor check To monitor an external contactor, the feedback circuit is connected to X17 and X18. The terminals X19 and X20 must be bridged. Start push button (S) The start push button can be used to start the monitoring of the light barriers for a new start or after an interruption. The terminals X3 and X4 must be bridged. It is also possible to connect only one pair of light barrier devices. The wiring diagram is shown for the de-energised condition. Documents Operating instructions and Declaration of conformity (it) 505 kb, 04.01.2012 Code: mrl_slb200-c_it Operating instructions and Declaration of conformity (fr) 584 kb, 12.08.2011 Code: mrl_slb200-c_fr Operating instructions and Declaration of conformity (nl) 573 kb, 30.08.2011 Code: mrl_slb200-c_nl Operating instructions and Declaration of conformity (de) 1 MB, 16.12.2010 Code: mrl_slb200-c_de Operating instructions and Declaration of conformity (en) 936 kb, 04.07.2011 Code: mrl_slb200-c_en Operating instructions and Declaration of conformity (jp) 622 kb, 10.05.2011 Code: mrl_slb200-c_jp Operating instructions and Declaration of conformity (es) 577 kb, 12.08.2011 Code: mrl_slb200-c_es Wiring example (99) 20 kb, 20.08.2008 Code: kslb2l01 BG-test certificate (de, en) 521 kb, 05.01.2011 Code: z_lb2p01 Images Wiring example

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 14.02.2013-17:06:31h Kasbase 2.2.2.F DBI Image Image et=ss9 &amp