Technology modules. 1 SSI interface for absolute encoders, 1 analog output S20-SSI-AO-1/1

Similar documents
Temperature modules. 8 inputs for connection of thermocouple sensors S20-AI-8-UTH

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

Temperature module. 4 inputs for thermocouples

Analog input module. 4 inputs, voltage and current

Modular I/O system. Power module

Communication modules. Serial interface module

SafeLogic compact. CPU module (EFI, ACR) SLC-3-CPU3

Temperature module. 4 inputs for resistance thermometers

Digital I/O modules. 8 inputs/outputs, M8

Fieldline. 4 digital inputs, 4 digital inputs/outputs RF-FLM DIO 8/4 M8

Fieldline. Fieldline Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12

Compact operator panels " display IndraControl VCP 02, 05, 08, 11

HMI/industrial PC. Plug-in card Sercos master module Sercans

Control hardware. IndraControl L75

Panel PC. 15" wide-screen display IndraControl VPP 15

Compact PC IndraControl VPB

Servo drives. Firmware 1G IndraDrive (MPH, MPB, MPD, MPC)

Software tools. CamBuilder

Servo Drives. Compact Drives IndraDrive Cs

Servo drives. Firmware 2G IndraDrive (MPE, MPB/MPM, MPC)

Rexroth Inline terminal with one analog output

Servo drives. Control units 1G IndraDrive (BASIC, ADVANCED)

Tightening system. Hand-held Nutrunners ErgoSpin SlimLine

Servo drives. SafeMotion

IndraLogic L Controller based

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PLC. IndraLogic V PC-based

PLC. IndraLogic L Controller-based

IndraDrive Cs Multiprotocol-capable compact drive system

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IndraDrive Cs Multiprotocol-capable compact drive system

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Synchronized motion control functionality IndraWorks The Tool for All Engineering Tasks

GFK-2415A March Type of sensor connection

DI561 Digital Input Module

TM3AI4 module TM3-4 analog inputs

TM3TM3 module TM3-2 temperature inputs and 1 analog output

AO561 Analog Output Module

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

DX561 Digital Input/Output Module

DI572 Digital Input Module

TM3TI4 module TM3-4 inputs temperature

2 Bosch Rexroth AG Electric Drives and Controls. Technical data. PLC IndraLogic XLC. Documentation Documentation

AI561 Analog Input Module

DC562, digital input/output module,

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Motion logic. Drive based IndraMotion MLD

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM3TI8T module TM3-8 inputs temperature

AXL E IOL AO1 U M12 R

Position sensor PO1 series 20

General information. Display. Supply voltage

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

IndraControl S67. Fieldbus coupler PROFINET

DC561, digital input/output module,

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PHOENIX CONTACT Features

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

General information. Display. Supply voltage. Input current. Encoder supply. Output current

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

TM3TI4 module TM3-4 inputs temperature

Draft sensor KMB series 30

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Material: Weight: Shaft Loads: Cable: Connector:

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

Motion logic system. IndraMotion MLC Control hardware IndraControl L

Rexroth IndraDrive Cs Multiprotocol-capable compact drives

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

Transcription:

1 SSI interface for absolute encoders, 1 analog output S20-

2 Bosch Rexroth AG Electric Drives and Controls Position detection via absolute encoders with SSI interface Encoder resolution up to 56 bit Transmission frequency up to 2 MHz Gray or binary code Rotation direction reversal Current and voltage measuring ranges Saved device nameplate Diagnostic and status indicators Documentation Data sheet Application description This module is designed for use within an IndraControl S20 station. It is used to detect positions by absolute encoder with SSI interface. An analog output, which serves to specify the command value for a drive control, for example, can be used at the same time. Technical data S20- Local bus interface Designation S20 local bus Connection type Connection for bus socket module Supply for module electronics Connection type Spring-cage connection with direct plug technology Connection data solid / flexible / AWG 0,2... 1,5 mm 2 / 0,2... 1,5 mm 2 / 24-16 Supply voltage 24 V DC Supply voltage range 19.2... 30 V DC (including all tolerances, incl. rippling) Logic voltage U BUS 5 V DC (via bus socket module) Current consumption of U BUS Max. 180 ma Protective circuit Overvoltage protection, reverse polarity protection, transient protection Analog Outputs Connection technology of the actuators 2-wire connection (shielded, twisted in pairs) Number 1 Load / output load current output Up to 500 W Output voltage range 0... 5 V, -5... 5 V, 0... 10 V, -10... 10 V Output current range 0... 20 ma, 4... 20 ma, -20... 20 ma Protective circuit Overvoltage protection, reverse polarity protection, transient protection Characteristics Measurement resolution 16 bits (15 + sign bit) Accuracy 0.1% (of output range end value) Encoder detection Type Symmetrical and asymmetrical encoders Number 1 Description of the input SSI interface

Electric Drives and Controls Bosch Rexroth AG 3 Encoder supply voltage Resolution 24 V DC 8 to 56 bits (configurable) Transmission frequency 2 MHz System times System bus cycle time 2 µs Offset per module 1 µs Load Vibration resistance 5 g according to EN 60068-2-6 Shock resistance 25 g according to EN 60068-2-27 Shock resistance (continuous shock) according 10 g according to EN 60068-2-29 to EN 60068-2-29 Emitted interference Class B according to EN 61000-6-3 Interference immunity According to EN 61000-4 Environmental conditions Permissible temperature (operation) -25... +60 C Permissible humidity (operation) Permissible humidity (storage) Protection category 5 to 95%, no dewing 5 to 95%, no dewing IP20 Dimensions 35 54 122,4 126,1 S20- Dimensions Height H [mm] 126.1 Width B [mm] 35 Length T [mm] 54

4 Bosch Rexroth AG Electric Drives and Controls Ordering information S20- IndraControl S20 analog input module - 1 SSI interface for absolute encoders, 1 analog output R911172544 S20-BS-S Bus base module (spare part) R911173203 S20-SHIELD SET Shield connection kit R911173030 S20-SHIELD-NLS Neutral busbar 3 mm x 10 mm, length: 1000 mm R911173283 S20-SHIELD-SK14 S20-SHIELD-SK5 Shielding terminal 14 mm for shield on busbars, contact resistance < 1 mohm, VPE: 10 pieces Shielding terminal 5 mm for shield on busbars, contact resistance < 1 mohm, VPE: 10 pieces R911173286 R911173282

Bosch Rexroth AG Postfach 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Tel. +49 9352 18-0 Fax +49 9352 18-8400 www.boschrexroth.com/electrics Local contact information can be found at: www.boschrexroth.com/adressen Bosch Rexroth AG 2012 Subject to modification. Printed in Germany The data specified above only serve to describe the product. As our products are constantly being further developed, no statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.