IndraControl S67. Fieldbus coupler PROFINET
|
|
- Daniella Cameron
- 5 years ago
- Views:
Transcription
1 Fieldbus coupler PROFINET
2 Bosch Rexroth AG Electric Drives and Controls Documentation Instructions Technical data S67-PN-BK-DI8-M8 System data Interfaces Number of segments per station Total of all I/O data per station Connection type Digital outputs Protection Digital inputs PROFINET IO Device max. 64 I/O module 512 Byte M12 connector, B-coded, 5 poles, shielded Short-circuit/discontinuity of sensor supply, subvoltage (ULS + UA) Number 8 Digital inputs Design According to EN type 1 Switching thresholds max. voltage at low level UL max Switching thresholds Max. voltage at high level UH max Common potentials < 5 V > 15 V Segment supply, ground Nominal input UI Nom [V DC] 24 Permissible nominal input voltage range -30 V DC < UIN < + 30 V DC [ma] 2.8 Permissible line length [m] 30 Sensor connection type Electrical data 2-, 3-wire connection M8 connectors, 3 poles Logic, sensor supply U LS [V DC] 24 Tolerances -25% +30% Actor supply U A [V DC] 24 Tolerances -25% +30% Typ. [ma] 5
3 Electric Drives and Controls Bosch Rexroth AG Connection type Transmission speed Error message to the higher level control system Status LED DIA - PROFIBUS diagnostics CS - Coupler status BF - PROFIBUS bus error BUS - PROFIBUS projecting error M12 connector, A-coded, 4 poles 100 Mbit/s, full-duplex Short-circuit/discontinuity of sensor supply, subvoltage (ULS + UA) LED (green/red) Input status LED (yellow) F - Error status U LS + U A - Supply status SB - system bus, status Protection Category Total Forces LED (green) LED (green/red) Vibration Resistance [g] 5 Shock Resistance [g] 50 Standards Certification UL 508 Weight Weight Ambient conditions Ambient temp. operation Min. [ C] -25 IP g Max. [ C] 60 Ambient temp. storage Min. [ C] -25 Max. [ C] 85 Relative humidity operation Min. [%] 5 Max. [%] 90 Relative humidity storage Min. [%] 5 Max. [%] 95 Atmospheric pressure (operation) Min. [kpa] 80 Max. [kpa] 106 EN (up to 2,000 above MSL) Atmospheric pressure (transport/storage) Min. [kpa] 66 Max. [kpa] 106 EN (up to 3,500 above MSL) Dimensions Dimensions Height H [mm] 117 Width B [mm] 75 S67-PN-BK-DI8-M8
4 Bosch Rexroth AG Electric Drives and Controls Depth T [mm] 35 Type code S67-PN-BK-DI8-M8 PROFINET IO (RT) Bus Coupler, 24 V DC, 8 digital inputs (M8) (i.p.) R Cable - Local bus Cable - Local bus RKB0041/000,2 Standard Systembus cable, M12 plug, M12 connector, Length 0,2m R RKB0041/000,3 Standard Systembus cable, M12 plug, M12 connector, Length 0,3m R RKB0041/000,5 Standard Systembus cable, M12 plug, M12 connector, Length 0,5 m R RKB0041/001,0 Standard Systembus cable, M12 plug, M12 connector, Length 1,0 m R RKB0041/002,0 Standard Systembus cable, M12 plug, M12 connector, Length 2,0 m R RKB0041/005,0 Standard Systembus cable, M12 plug, M12 connector, Length 5,0 m R RKB0041/010,0 Standard Systembus cable, M12 plug, M12 connector, Length 10,0 m R RKB0041/xxx,x Standard Systembus cable, M12 plug, M12 connector, variable length R RKB0049/xxx,x Standard Systembus cable, M12 plug, M12 connector, variable length, dragline R RBS0020 Systembus termination, connector B-coded R Cable - Voltage Supply Cable - Voltage Supply RKB0046/000,2 RKB0046/000,3 RKB0046/000,5 RKB0046/001,0 RKB0046/002,0 RKB0046/005,0 - Länge 0,2 m - Länge 0,3 m - Länge 0,5 m - Länge 1,0 m - Länge 2,0 m - Länge 5,0 m R R R R R R
5 Electric Drives and Controls Bosch Rexroth AG RKB0046/010,0 RKB0046/xxx,x RKB0047/005,0 RKB0047/010,0 - Länge 10,0 m - M12 connector, straight, A-coded, variable length, dragline Voltage cable, unshielded 4-pin, 0.75 mm2, PUR M12 socket, straight, A-coded - free conductor end, dragline - Length 5,0 m Voltage cable, unshielded 4-pin, 0.75 mm2, PUR M12 socket, straight, A-coded - free conductor end, dragline - Length 10,0 m R R R R Mounting Mounting SUP-M01-S Mounting rail adapter bus coupler R SUP-M01-S Profil adapter bus coupler R SUP-M01-S Spacer module R SUP-M01-ENDHALTER Snap-on end bracket, DIN mounting rail 35 mm, width: 9,5 m R SUP-M01-ENDHALTER/AL End bracket, aluminium, DIN mounting rail 35 mm, width: 10 mm R SUP-M01-ENDHALTER/PA End bracket, Polyamide, DIN mounting rail 35 mm, width: 9,5 mm R Protection and sealing elements Protection and sealing elements RF-PROT-M8 Protection cap M8 for unoccupied M8 sockets R SUP-M01-SM*12.1 Protection cap M12 for unoccupied M8 sockets R RF-PROT-M12-M Protection cap M12 for unoccupied M12 connectors R Marking Marking SUP-M01-S Marking strip for bus coupler and I/O modules (8xM8), Packaging Unit = 10 R Others Others
6 Bosch Rexroth AG Electric Drives and Controls RKB0042_003,0 USB service cable, Length 3,0 m R
7
Analog Input Modules. 4 Inputs
Bosch Rexroth AG Electric Drives and Controls Documentation Instructions Technical data S67-AI4-U/I-M12 Analog inputs Number 4 Conversion time of A/D converter analog input module for current- and voltage
More informationFieldline. Fieldline Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12
Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12 2 Bosch Rexroth AG Electric Drives and Controls Documentation Technical data Local bus interface Designation Local
More informationAnalog input module. 4 inputs, voltage and current
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs: M12, 0 to 20 ma, 4 to 20 ma, ±20 ma, 0 to 10 V, ±10 V Technical data S67-AI4-U/I-M12 Local bus interface Designation System bus M12
More informationModular I/O system. Power module
2 Bosch Rexroth AG Electric Drives and Controls Documentation Supply module Connection: 1x M23 / 6x M12 The passive feed module is used to supply voltage to IndraControl S67 components. Thanks to options
More informationTemperature module. 4 inputs for thermocouples
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs, M12 Thermocouples (TC) M12 Technical data S67-AI4-UTH-M12 Local bus interface Designation System bus M12 connector, B-coded, 5-pin,
More informationDigital I/O modules. 8 inputs/outputs, M8
2 Bosch Rexroth AG Electric Drives and Controls Documentation Digital I/O module 8 inputs/outputs 0.5 A per channel M8 Technical data S67-DIO8-M8 Local bus interface Designation System bus M12 connector,
More informationCommunication modules. Serial interface module
2 Bosch Rexroth AG Electric Drives and Controls Documentation 2 serial channels RS232, RS485/422 4 digital inputs/outputs M12 Technical data S67-RS-UNI-M12 Local bus interface Designation System bus M12
More informationTemperature module. 4 inputs for resistance thermometers
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs, M12 Resistance thermometer, resistors, potentiometer Technical data S67-AI4-RTD-M12 Local bus interface Designation System bus M12
More informationFieldline. 4 digital inputs, 4 digital inputs/outputs RF-FLM DIO 8/4 M8
4 digital inputs, 4 digital inputs/outputs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Technical data Local bus interface Designation Local bus M8 connector Supply for module electronics
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationGeneral information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationIL CAN BK-TC-PAC. Extract from the online catalog. Order No.:
Extract from the online catalog IL CAN BK-TC-PAC Order No.: 2718701 CANopen bus coupler, 24 V DC, bus interface 2 x 5-pos. TWIN- COMBICON connector, complete with accessories (connector and labeling field)
More informationGeneral information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information
More informationTemperature modules. 8 inputs for connection of thermocouple sensors S20-AI-8-UTH
8 inputs for connection of thermocouple sensors 2 Bosch Rexroth AG Electric Drives and Controls 8 inputs for thermocouples Linear voltages from -100 mv to +100 mv 1 input -5 V to +5 V 4 Pt 100 inputs (external
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information
More informationIM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP
IM 151-1 Design The IM 151-1 interface modules are directly snapped onto the standard mounting rail. IM 151-1 modules feature: DIP switch for setting the PROFIBUS DP station address (1 to 125) Diagnostics
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory
Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC
More informationGeneral information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply
More informationGeneral information. Display. Supply voltage. Input current
Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering
More informationGeneral information. Supply voltage. Input current. Encoder supply. Power loss. Memory
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes
Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationVERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012
June 2012 VERSAMAX IP PROFINET SCANNER 1 Description The device connects a VersaMax IP Modular station to a PROFINET IO network and is also used to acquire digital signals. This description applies to
More informationIL CAN BK-TC-PAC. Extract from the online catalog. Order No.:
Extract from the online catalog IL CAN BK-TC-PAC Order No.: 2718701 CANopen bus coupler, 24 V DC, bus interface 2 x 5-pos. TWIN- COMBICON connector, complete with accessories (connector and labeling field)
More informationMultiturn absolute encoder
Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information
More informationPA ROUTERS. The following criteria can be applied when choosing the network transition:
PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER
More informationHa-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features
2000 Fast and Full Gigabit Ethernet Basic Commercial Temp.: / Industrial Temp.: Power Sourcing Equipment (PSE) with 4 Ports PoE+ (34.2 watts per port) General description Unmanaged Ethernet switches of
More informationGeneral information Engineering with Programming package. Display with display
Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General
More informationXPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term
Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Power losses
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationSafety modules. 8/4 inputs PROFIsafe S20-PSDI8/4
8/4 inputs PROFIsafe 2 Bosch Rexroth AG Electric Drives and Controls 8/4 inputs PROFIsafe SIL 3 to EN 61508 SILCL 3 to EN 62061 Category 4 / PL e according to EN ISO 13849-1 PROFIsafe Electronic device
More informationAXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description
Axioline bus coupler for PROFINET IO Data sheet 7992_en_02 PHOENIX CONTACT 2012-07-09 1 Description The bus coupler links a PROFINET IO network with the Axioline system. Up to 63 Axioline devices can be
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationBL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 4 analog
More informationTechnology modules. 1 SSI interface for absolute encoders, 1 analog output S20-SSI-AO-1/1
1 SSI interface for absolute encoders, 1 analog output S20- 2 Bosch Rexroth AG Electric Drives and Controls Position detection via absolute encoders with SSI interface Encoder resolution up to 56 bit Transmission
More informationIB IL 24/48 DOR 2/W-XC-PAC
Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationDigital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface
Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationSTBEHC3020KC counter kit STB - 1 CH Hz - 2 I
Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency
More informationSubmittal Data Sheet WAGO Node for itm
The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via
More informationControl hardware. IndraControl L75
2 Bosch Rexroth AG Electric Drives and Controls Documentation Advantages: Scalable hardware platform Standardized communication interfaces Optional extension through function and technology modules Ideal
More informationBL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 8 configurable
More informationProfibus-DPV1 Set in IP67 TI-BL67-DPV1-6
Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment
More informationIE/PB LINK PN IO. PROFINET applications
IE/PB LINK PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence
More informationIBS ST (ZF) 24 BK LB-T
. - IBS ST (ZF) 24 BK LB-T Bus Terminal Module With Local Bus Branch Data Sheet 5049B 09/1999 5049B000 ' " # " % 1 6-4 * 7 5 7 4 + * ) * ) - -,, 4, 4 A? BEC K H= JE 7 5 * K I 6 A H E = " 8, + @ K A 1@
More informationNI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O
DATASHEET NI REM-11180 Bus Coupler for Remote I/O Deterministic communication and data transfer to host system EtherCAT cycle time of
More informationIBS IL 24 BK RB-T-2MBD
IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationFL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:
Extract from the online catalog FL SWITCH 8TX Discontinued item Order No.: 2832218 Ethernet Switch, 8 front Ethernet ports in RJ45 format, automatic detection of data transmission speed of 10 or 100 Mbps,
More informationNEW. Phone: Fax: Web: -
NEW 8-port unmanaged switch in IP67 Just 54 mm wide One LED per port for link / speed / data Fault relay: 1 x M12 A-coded, 5-pole (24 V DC / 1 A) 8 x M12 D-coded, 4-pole Redundant voltage supply 2 x M12
More informationBox-PC / Displays. Compact PC IndraControl VPB
Compact PC IndraControl VPB Bosch Rexroth AG Electric Drives and Controls Documentation Technical data VPB 40.3K VPB 40.3L VPB 40.3M Processor CPU Core Duo L2400; 1.66 GHz (Standard) Core2 Duo T7400; 2.16GHz
More informationFieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway
Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety
More informationAXL E IOL AO1 U M12 R
Axioline E IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, rectangular version Data sheet 8588_en_03 PHOENIX CONTACT 2014-09-22 1 Description The IO-Link/analog converter is an
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More information8 24 V DC, 8 24 V DC,
Axioline F digital input and output module, 8 inputs, 24 V DC, 8 outputs, 24 V DC, 500 ma, single-conductor connection technology Data sheet 8670_en_02 PHOENIX CONTACT 2014-04-30 1 Description The module
More informationDistribution Systems for Sensors and Actuators
Distribution Systems for Sensors and Actuators Comprehensive OVERVIEW M12 Distribution Boxes M8 Distribution Boxes Accessories Distribution Systems for sensors and actuators THE RIGHT DISTRIBUTION BOX
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationPhone: Fax: Web: -
In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. The controller monitors
More informationDI572 Digital Input Module
Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968
More informationPCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1
Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10
More informationRSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017
November 2017 Ethernet Ports PWR, SF, BF, MT, LINK 1, ACT 1, LINK 2, and ACT 2 LEDs Door for Micro USB Port PROFINET Scanner Power Supply LED RSTI-EP Slice I/O PROFINET Scanner The PROFINET Scanner is
More information6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)
6ES7212-1BD30-0XB0 Page 1 Product data sheet 6ES7212-1BD30-0XB0 SIMATIC S7-1200, CPU 1212C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 0,5A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC
More informationDI561 Digital Input Module
Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital
More informationRodless cylinders Rodless cylinders Series RMC. Brochure
Brochure Bosch Rexroth AG Pneumatics -SB Ø 16-32 mm double-acting with magnetic piston Slide bearing guide cushioning: pneumatically, adjustable 4 -SB Ø 16-32 mm double-acting with magnetic piston long
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationIBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description
IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationIB IL 24 DI 16 IB IL 24 DI 16-PAC
IB IL 24 DI 16 IB IL 24 DI 16-PAC Inline Terminal With 16 Digital Inputs Data Sheet 555302 06/2003 + Features This data sheet is only valid in association with the IB IL SYS PRO UM E User Manual or the
More informationAXL E PN DI8 DO8 M12 6P
Axioline E PROFINET device, plastic housing, 8 inputs, 8 outputs, 24 V DC, M12 fast connection technology Data sheet 8446_en_04 PHOENIX CONTACT 2015-10-15 1 Description The Axioline E device is designed
More informationAXL E PB DIO16 M12 6P
Axioline E PROFIBUS device, plastic housing, 16 freely configurable inputs or outputs, 24 V DC, M12 fast connection technology Data sheet 8437_en_03 PHOENIX CONTACT 2015-09-03 1 Description The Axioline
More informationAXL F BK PN. Axioline F bus coupler for PROFINET. Data sheet. 1 Description
Axioline F bus coupler for PROFINET Data sheet 105731_en_04 PHOENIX CONTACT 2016-01-04 1 Description The bus coupler links a PROFINET network with the Axioline F system. You can connect up to 63 Axioline
More informationKit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8
Type code Ident no. 1545153 Number of channels 8 Dimensions (W x L x H) 204 x 145 x 77.5 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between
More informationUser Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX
User Manual MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the
More informationPSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.
PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS
More informationVAL-62. Fieldbus modules FD67 Series Input, output and analog modules with IP67 ingress protection. Valves
Valves Fieldbus modules Reduced cabling and installation costs 256 I/O per node Single channel diagnostics IP67 Ingress protection Fully configurable I/O points Compact, robust construction Fieldbus nodes,
More informationCompact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM
Multiprotocol I/O module for the Ethernet protocols Modbus TCP, Ether- Net/IP and PROFINET PROFINET supports Fast Start-Up (FSU) EtherNet/IP supports QuickConnect (QC) Integrated Ethernet switch FDT/DTM
More informationRMx621. Appendix to the operating manual
Appendix to the operating manual RMx621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 to PROFIBUS DP via the RS485 serial interface using the external module (HMS AnyBus Communicator
More information