are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. Trunk 6 channels/stranded screened single cables S-STP Cat.7, AWG 23 installation cable diameter 22,3 mm both sides assembled with Multijumper 6 channels/stranded screened single cables S/FTP Cat.7, AWG 26 flex cable diameter 18 mm alternatively assembled with RJ45 Jack modules and Plug connectors acc. to page 3 possible variants Plug-Plug Plug-Jack Jack-Jack leg lengths acc. to page 2 example picture here: Plug-Jack (1) (1) (3) (2) (1) Like our factory assembled PreCONNECT FO-Trunks and Multijumpers, our Trunks and Multijumpers are predestined for fast, easy and secure Plug-and-Play installations in Data Centers. The decisive advantage is the surpassing fast installation time and you don`t need qualified personnel with tools and measurement equipment for the installation. For conventional installations of copper data cables there are usually some installers working for a longer period of time inside of the sensitive security areas of your Data Center. To carry out the time consuming on-site termination of the copper Jack modules or connector Plugs onto the copper cables. For secure installation the factory assembled copper Jack modules (1) and connector Plugs (2) on both sides are perfectly protected by packing them in (3) tensile strength, crush resistant and dust-proof installation tubes or alternatively just in tensile strength and dust-proof pulling socks. Please see next page for further explanations. is 100% factory measured and delivered with measurement protocol. You only have to lay the cables into your raised floor, detach the installation tubes and plug the copper Jack modules into the panels or plug-in of the connector Plugs. Page 1 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40
Leg lengths of Jack modules alternatively (sl) legs of the same length to run the cable straight from the rear side to the panel (stl) legs with stepped lengths to run the cable from either both sides to the panel!!! if you order (stl) stepped legs, you must state if you want to run the cable either from the left or from the right side to the panel, view from the rear, like shown below (necessary because of the numbering of the legs). If legs stepped for running from the left the longest leg is number 1 and the shortest number 6. If legs stepped for running from the right the longest leg is number 6 and the shortest number 1. View from the rear onto the panel like shown here (sl) same length legs (stl) stepped lengths legs running to the panel from the right (sl) 30 cm (stl) (stl) 45 cm Leg lengths of connector Plugs can be ordered in variable lengths (sl) On request longer Jack module leg lengths are deliverable too and can be extended easily during the installation > just remove the heat shrink tube and foil tape and fix the tape`s new end with an adhesive tape. Both leg variants are alternatively available in (EZS) our recommendation!!! > in tensile strength, crush resistant and dust-proof installation tubes, but dependant on the leg variants described above, the installation tubes are up to 90mm diameter. (ZS) just in tensile strength and dust-proof but not crush resistant pulling socks, but their diameter is thinner, even their diameter is dependant on the leg variants described above as well. (EZS) (ZS) Page 2 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40
Cable types: For Trunks: Dätwyler Uninet 7002 6x4P Breakout Light 6 single stranded Cat.7 S-STP copper data cables taped with a self-extinguishing, halogen-free transparent foil tape, solid wire AWG 23, screened pairs and overall copper braid Diameter = 22.3 mm, minimum bending radius during installation = 100mm, in operation = 90mm Maximum class EA 10GBE transmission length = 90 m (for 100m channel with 10m for Patchcords) For Multijumper: Dätwyler Uninet 7702 6x4P Flex Breakout Light 6 single stranded Cat.7 S/FTP copper data cables taped with a self-extinguishing, halogen-free transparent foil tape, flex braid wire AWG 26, screened pairs and overall copper braid Diameter = 17.6 mm, minimum bending radius during installation = 70 mm, in operation = 50 mm Maximum class EA 10GBE transmission length = 60 m (for 70m channel with 10m for Patchcords) Due to the stranding and the thin foil tape the cables are highly bending flexible and through this installation-friendly. And they have a thinner outher diameter, lower fire-load and weight compared to other cables of that type, they typically have a real thick outher cable jacket. RJ45 Jack module connector Plug: Dätwyler Unilan MS-K 1/8 RJ45 Cat.6a screened Telegärtner RJ45 MP8(8) Other modules and connectors on request For our Trunks we offer fitting 19 1HU Panels in our new Smart-Plug design and Standard Panels. For part numbers please see the end of the document. Delivery form: Dependent on the length as cable ring or on cardboard or wooden drum with installation instruction and measurement protocol. is deliverable with other cable types, other numbers of single cables/channels and other modules on request Part numbers: Please see the end of the document. Page 3 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40
Certification"4 connector 10GBE channel class EA" For Trunk 10GBE, class EA, RJ45 with Unilan MS-K Jack modules at Uninet 7002 cable. This product information specifies, Dätwyler cable type Uninet 7002 (stranded as 6 channel Breakout Light) and Unilan MS-K Jack modules used for our PreCONNECT COPPER Trunk 10GBE, class EA, RJ45. The GHMT certificate No. 1675a-07-E below shows the combination Unilan MS-K Jack module at Dätwyler cable type Uninet 7080 certified, but not our cable type Uninet 7002. But the Dätwyler information below confirms that the GHMT certificate is also valid for our cable type Uninet 7002 (and some others). Consecuently our PreCONNECT COPPER Trunk 10GBE, class EA, RJ45 with Unilan MS-K Jack modules at Uninet 7002 cable is 4 connector 10GBE channel class EA" qualified. But of course only with the in the GHMT certificate qualified Dätwyler RJ45 Patchcords Dätwyler Art.-Nr. 653 510 and 653 512. For part numbers please see the end of the document. For Multijumper we don`t have a qualification of an independent lab yet, but we can proof their 4 connector 10GBE channel class EA" performance by own measurement (max. only 70m through AWG26). Page 4 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40
We also have qualified the Data Center channel 10GBE shown below acc. to class E A with PreCONNECT COPPER Trunks, because its configuration is very common in Data Centers, through its best practice value and standard compliance acc. to EN50173-5. With the newly added PreCONNECT COPPER Multijumpers, different data center transmission channels can be realised with them or in combination with PreCONNECT COPPER Trunks. Planning such channels, the length limitations of the different cable types and the maximum possible number of connections acc. to EN50173-1 and -5 must be considered. Page 5 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40
Part numbers: Trunk cable, factory assembled on both sides, variable length Jack module type Legs on both sides OSI Description on both sides acc. to page 2 part number PreCONNECT Dätwyler Unilan same length 047A0101 MS-K 1/8 COPPER, 10GBE, stepped for from the left side 047A0111 RJ45 Cat.6a screened class E A, RJ45 stepped for from the right side 047A0121 With other Jack module types, e.g. GG45, for other classes on request Multijumper, factory assembled on both sides, variable length Description Side A Side B OSI part number Jack modul Dätwyler Unilan Jack modul Dätwyler Unilan Multijumper MS-K 1/8 RJ45 Cat.6a MS-K 1/8 RJ45 Cat.6a 047A0130 Jack-Jack screened, on same length legs screened, on same length legs 10GBE, class E A, RJ45 acc. to page 2 acc. to page 2 Multijumper Plug-Jack 10GBE, class E A, RJ45 Multijumper Plug-Plug 10GBE, class E A, RJ45 Other configurations on request Telegärtner RJ45 MP8(8)FS, leg length variable Telegärtner RJ45 MP8(8)FS, leg length variable Example picture here: Plug-Jack Jack modul Dätwyler Unilan MS-K 1/8 RJ45 Cat.6a screened, on same length legs acc. to page 2 Telegärtner RJ45 MP8(8)FS, leg length variable 047A0131 047A0132 Page 6 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40
Dätwyler Unilan Patch and Equipment cords RJ45/RJ45, Cat.6, 7702 flex 4P, 1:1 coding Screened RJ45 connectors with moulded boots on both sides. Uninet 7702 flex 4P cable with individual foil screened pairs (PiMF), Cat.7 for transmission rates up to 1200 MHz. The types listed below are the two specified ones of the certification of the "4 connector 10GBE channel class EA" in the middle of the document. Color: grey other lengths, colors and types on request Dätwyler part number length OSI part number 653 510 2 Meter 800A0003 653 512 3 Meter 800A0005 Part numbers: Smart-Plug 19 1HU Panel, assembled with two ½ part front plates (PFPs) RAL 9005 black matt, HDCS matrix numbering suitable for fits for OSI part number, 24 pcs. Dätwyler Unilan MS-K 1/8 161A5002 10GBE, class E A, RJ45 RJ45 Cat.6a screened modules For other Jack module types on request 19 1HU Standard Panel suitable for fits for OSI part number, 24 pcs. Dätwyler Unilan MS-K 1/8 RAL7035 (light grey) 800A0200 10GBE, class E A, RJ45 RJ45 Cat.6a screened modules RAL9005 (black) 800A0201 For other Jack module types on request Page 7 of 7 www.rosenberger-osi.com Tel.: +49 821 24 92 40