S-series Serial Interface

Similar documents
S-series Serial Interface

M-series Serial Interface Series 2

M-series Serial Interface Series 2

S-series Profibus DP Interface Card

S-series DeviceNet Interface Card

S-series Sequence of Events Card

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

DeltaV SD Plus Controller

S-series Horizontal Carriers

S-series H1 I/O Card with Integrated Power

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

M-series Profibus DP Series 2 Plus Interface Card

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

S-series Foundation Fieldbus I/O

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

M-series Foundation Fieldbus I/O

S-series Virtual I/O Module 2

M-series Virtual I/O Module 2

M-series MQ Controller

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

M-series Profibus DP Series 2 Plus Interface Card

M-series Virtual I/O Module 2

S-series DeviceNet Interface Card

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

S-series Sequence of Events Card

M-series MX Controller

S-series Virtual I/O Module 2

S-series Electronic Marshalling for Migrations

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

S-series Horizontal Carriers

M-series DeltaV Controller Interface for RS3 I/O

DeltaV Ethernet I/O Card

M-series DeltaV Controller Interface for PROVOX I/O

M-series Traditional I/O

M-series DC to DC Power Supply

DeltaV Virtual IO Module Network Gateway

S-Series DeltaV Controller Interface for PROVOX I/O

S-series Ethernet I/O Card

Plant Messenger. Introduction. DeltaV Product Data Sheet. Delivers the information you want when and where you want it

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

Batch Historian. Batch Historian. Introduction. DeltaV Product Data Sheet. Configuration-free, batch-based data collection

S-series Mass Connection Solutions

DeltaV SIS Conditioning Components

M-series Intrinsically Safe I/O

DeltaV Bulk Power Supplies

DeltaV M-series I/O Subsystem Horizontal Carriers

History View Software Suite

M-series MQ Controller

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

M-series I/O Subsystem Horizontal Carriers

Operator Station Software Suite

DeltaV History Analysis

DeltaV Bulk Power Supplies

DeltaV Wireless I/O Card

DeltaV SIS TMConditioning Components

S-series Electronic Marshalling

DeltaV VerticalPlus I/O Subsystem Carriers

DeltaV Electronic Marshalling for Migrations

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Faster module execution

DeltaV Connect Solution for Bailey Systems

S-series IS Electronic Marshalling

Emerson & Westinghouse

DeltaV Control Network Hardware

DeltaV M-series Traditional I/O

OPC Mirror Redundancy

Product Data Sheet DeltaV Operate for PROVOX July 2014 Page 1

Product Data Sheet DeltaV 10.3 with AMS Device Manager Simplified Chinese Jan 2010 Page 1

OPC Data Access Server Redundancy

DeltaV M-series Traditional I/O

DeltaV M-series Traditional I/O

DeltaV Controller Firewall

Operator Station Software Suite

DeltaV Four-Monitor Workstation

DeltaV Simulate. DeltaV Simulate. Introduction. DeltaV Product Data Sheet. Allows DeltaV configuration on a single PC or in a multi-node system.

DeltaV S-series Traditional I/O

Rotork Pakscan Driver for DeltaV Programmable Serial Interface Card

Ovation Ethernet Link Controller Module Data Sheet

Smart Commissioning. White Paper February 2018

APACS to DeltaV System Connectivity

DeltaV Connect Solution for Moore Systems

ROConnect Interface. ROConnect Interface. Introduction. DeltaV Product Data Sheet. Native DeltaV system integration

Smart Commissioning. White Paper January 2019

Batch Analytics. Batch Analytics. Introduction. DeltaV Product Data Sheet. Predicts end-of-batch quality

S-series Electronic Marshalling

OPC Mirror. Introduction. OPC Server. Bi-directional data flow. Easy configuration. Fast data transfer. OPC Data Access compliant.

EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO

S-series Electronic Marshalling

DeltaV SIS with Electronic Marshalling - Virtual Simulation

Wireless Field Data Backhaul

PG AB Notifier NFS 3030 to Modbus RTU Protocol Converter

DeltaV SIS Standalone

DeltaV Discovery for Life Science Research Laboratory Applications

DeltaV Connect Solution for Siemens TELEPERM M Systems

ControlWave PAC Redundant Systems

Enron Modbus I/O Driver (Series 2) Programmable Serial Interface Card

DeltaV OPC UA Servers and Clients

LCp-100 Weight Indicator/Transmitter

Professional Station Software Suite

DeltaV Display Transition Services for Honeywell Systems

Transcription:

January 2013 Page 1 The DeltaV provides a connection between the DeltaV system and other devices Provides seamless information interface Plug-and-play easy to use Extends the life of existing equipment 1:1 redundancy for Serial Interface I/O cards Automatic switchover Introduction The provides a connection between the DeltaV system and devices that support a serial protocol, such as Modbus or Allen Bradley s Data Highway Plus. The is supplied with Modbus software drivers pre-loaded. Additional drivers are available to allow a wide variety of devices to be integrated directly into the DeltaV controller s I/O subsystem. Data can be used by control modules or communicated to workstations as SCADA tags for display and/or historising. Like all DeltaV I/O, the Serial Interface may be added online while the rest of the controller I/O is powered up and in use. DeltaV Serial Interface can also be installed as a redundant pair for critical applications needing the highest availability. www.deltav.com

January 2013 Page 2 Benefits Provides Seamless Information interface. Using the Serial Interface with the DeltaV system, you gain an extended view of your entire plant. All serial information from 3 rd party systems, analyzers, PLC s, is readily available for display at the Operator Interface. When connected to a PLC, DeltaV software may pass supervisory information to the PLC facilitating the coordination of control strategies across systems. Plug-and-play easy to use. Plug-and-play installation saves money. The Serial Interface works just like other DeltaV I/O interfaces. It fits into any available slot on the controller I/O carrier. There are no dipswitches. Just plug it in! The DeltaV controller auto-senses the Serial Interface and presents the configuration options. Online help makes this interface a snap to configure. After a simple point-andclick configuration exercise, your integrated solution is up and running. Extends the life of existing equipment. Enhance existing capabilities don't replace them. Many plants have a variety of devices already installed. With the Serial Interface you are able to effectively interface a DeltaV system with existing PLCs or other serial devices. This means that you can layer the state-of-the-art process control offered by a DeltaV system on to the devices you already have in place. 1:1 Redundancy for Serial I/O cards. You can add Serial interfaces as simplex cards or redundant pairs. The interfaces automatically detect the presence of the redundant terminal block and are autosensed by the system as a redundant pair. There is no additional configuration. Use redundant Serial interfaces with slave devices that support redundant serial ports. Automatic Switchover. Should a primary Serial Interface card fail, the system automatically switches to the "standby" card without user intervention. The operator is given clear notification of a switchover at the operator display. The standby card continually polls the slave devices for diagnostic to confirm its ability to take over communications. Product Description The Serial Interface consists of a serial card and a terminal block. The card contains two serial communications ports that support RS232 and RS422/485 half duplex, or RS422/485 full duplex signals. These ports are individually configurable and support data rates from 300 Baud up to 115 KBaud. The S-series card plugs into an 8-wide I/O carriers in any of the possible 64 slots and communicates with the S- series controllers. LEDs, located on the front of the card, show the power, error, and port status of the interface at a glance. The standard Modbus protocol includes the Serial Interface, the Modbus RTU, and ASCII communications protocol as defined in the Modicon Modbus Protocol Reference Manual dated March 1992 (PI-MBUS-300 REV D). Each Serial Interface port may be configured as either a master or slave device. The serial card supports the following features using the Modbus protocol: Reading input data from Modbus coils, input status, holding registers and normal input registers. Writing output data to coils and holding registers. Output data can be written in single coil, register mode, or complete data set mode. This output mode is a configurable parameter. Input data can be read in as a complete data set, providing the best performance. The serial card supports the input and/or output of 16 different data sets per serial port, for a total of 32 data sets per Serial Interface. Serial dataset registers can be referenced directly in control modules as analog or discrete I/O providing fast easy data exchange with the serial device. Direct moduleto-dataset/register references are recommended for control signals. Alternatively, users can read multiple registers form a Dataset into a single marshalling module at the cost of a single DST. Marshalling modules provide a cost effective way to integrate serial data from analyzers and other data sources. Serial dataset registers can also be passed as SCADA values directly to Workstations and Continuous Historians without consuming DST s Both Modbus RTU and Modbus ASCII communications modes are supported by standard Modbus protocol.

January 2013 Page 3 The redundant pair can be manually configured or Autosensed. The redundant terminal block couples the two cards as one redundant pair that when Autosensed, the DeltaV system automatically recognizes the redundant pair of cards and assigns a device signal tag (DST) to the datasets on the primary card (Odd numbered card). Switchover time for redundant I/O is minimal, and the process will be undisturbed. Output channel behavior on switch over can be configured to resend outputs on a switchover. This can be coupled with Output Read back to ensure the output channels are driven to the desired state upon switchover. An alarm on the integrity error for the primary card notifies the operator of a switchover. The backup card is also monitored for integrity alarms. S-series simplex Serial Interface Redundancy Made Easy The Redundant Serial Interface consists of a pair of serial cards and a redundant terminal block. The cards each contain two serial communications ports that support RS422/485 half duplex (in either single slave or multi-drop configurations), or RS422/485 full duplex (in single slave configuration only), as well as RS232. These ports are individually configurable and support data rates up to 115 KBaud. Slave devices must provide two serial ports in order to allow the active and standby serial cards to be connected. The Active card continually poll input data and writes output data to the device on one serial link, while the standby card periodically polls the slave device for a diagnostic register. Verify with the device supplier for its ability to support redundant Modbus serial communications. When a fault is detected, the system automatically switches to the backup serial card. Events that can cause a switchover include: Hardware failure within the active card Loss of Communications (including field cable and slave port problems) between the active card and the slave device. Removal of the active card from the carrier A switchover may also be initiated from control logic. This allows additional watchdog logic to monitor multiple slave devices for communication faults not detected by the Serial Interface. A manual switchover can be initiated from diagnostics explorer The system automatically commissions and downloads a replacement standby card. In safe areas, failed cards can be replaced under power. In hazardous areas, appropriate installation procedures must be followed. Other Protocols Supported The DeltaV S-series Serial Card can support other serial driver protocols downloaded directly into the serial card. Custom drivers available from Emerson Process Management include: AGA3 Gas Flow Calculators AGA8 Gas Flow Calculators Allen-Bradley Data Highway Plus Control Technique Drive (Modbus) Mettler O-082 Weight Scale Modbus Redundancy Moore Products LIL RMV9000MVCU3 Controller Rotork Pakscan Satorious MP-8 Weight Scale Satorious xbpi Weight Scale Siemens 3964R Spartan DeltaV Metering Program Turnbull TCS6000 Brooks Instruments Petrocount Ratio Management System Emerson Process Management has a long history of developing new custom serial driver protocols for its other control systems. Call your local sales office for availability of these drivers and any driver not listed above

January 2013 Page 4 Hardware Specifications Number of serial ports 2 Number of data sets per Serial Interface card Port types Isolation Specifications for Serial Interface I/O Card 32 (16 per port) RS232, RS422/485 half duplex, RS 422/485 full duplex Each port is isolated from the system and from the other. These ports must be externally grounded. Communication Specifications Baud rate 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity Data bits 7 or 8 Stop bits 1 or 2 Retry count 0 255 Message time out Transmit delay Send outputs on startup Operating temperature Storage temperature Relative humidity Airborne contaminants Protection rating IP 20 Shock Vibration Even, Odd, None 100 25,500 msec. (100 msec. Increments) 0 25,500 msec. (100 msec. Increments) In the DeltaV Explorer, the user is able to indicate whether or not outputs should be sent on interface initialization. Environmental Specifications -40 to 70 C (-40 to 158 F) -40 to 85 C (-40 to 185 F) 5 to 95%, non-condensing ISA-S71.04-1985 Airborne Contaminants Class G3 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

January 2013 Page 5 System Compatibility Requires DeltaV SD or SX controller. Certifications The following certifications are available on the S-series Serial Interface card. CE: - EMC- EN 61326-1:2006 - LVD- EN 61010-1:2001 CSA: - CLASS 2252 05 - PROCESS CONTROL EQUIPMENT: CAN/CSA-C22.2 No. O-M91 General Requirements- Canadian Electrical Code, Part II CAN/CSA-C22.2 No. 61010-1-04 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements The following certifications have been submitted for Hazardous Locations and for Marine applications. Please verify with the appropriate certifying agency for a specific list of approved components CENELEC Zone 2 ATEX/IEC EX EN 60079-15:2005 Certifying agency: Nemko Certificate Number: TBD Refer to document TBD "DeltaV Scalable Process System Zone 2 Installation Instructions" FM Approval Class 1 Division 2 Hazardous Locations Certifying agency: FM Approvals Certificate Number: TBD Refer to document TBD "DeltaV Scalable Process System Class 1 Division 2 installation Instructions Complies with NAMUR NE21 per DeltaV Digital Automation System NAMUR NE21 Installation Instructions 12P2822. Marine Certifications: IACS E10:2006 Rev.5 Control, protection & Safety - ABS Certificate of Design Assessment - Bureau Veritas Certificate - DNV Marine Certificate - Lloyds Register GOST Hazardous Area certification Zone 2 (Russian) Other country specific certifications may also be available. Verify with your local Emerson sales office to confirm any certification requirements not listed here.

January 2013 Page 6 Ordering Information Description Model Number Card, 2-ports SE4006P2 (includes 1 Interface Card and a simplex Terminal Block) Redundant Card, 2-ports SE4036P2 (includes 2 Interface Cards and a redundant Terminal Block) The DeltaV Serial Interface Redundancy Cards ship from the factory with Modbus drivers pre-installed. To locate a sales office near you, visit our website at: www.emersonprocess.com/deltav Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 For large power, water, and wastewater applications contact Power and Water Solutions at: www.emersonprocess-powerwater.com Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East, Africa: 48.22.630.2443 North America, Latin America: +1 412.963.4000 Emerson Process Management 2013. All rights reserved. For Emerson Process Management trademarks and service marks, go to: http://www.emersonprocess.com/home/news/resources/marks.pdf. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. www.deltav.com