Rittal Cooling Solutions A. Tropp

Similar documents
Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Close Coupled Cooling for Datacentres

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Switch to Perfection

Liquid Cooling Package LCP Cooling Systems

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Reducing Data Center Cooling Costs through Airflow Containment

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Thermal management. Thermal management

Power and Cooling for Ultra-High Density Racks and Blade Servers

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Liquid Cooling Package LCP Cooling Systems

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

A Green Approach. Thermal

How to Increase Data Center Efficiency

Power Monitoring in the Data Centre

INNOVATE DESIGN APPLY.

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

INNOVATE DESIGN APPLY.

LCP Hybrid Efficient performance with heat pipe technology

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Virtualization and consolidation

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

One Stop Cooling Solution. Ben Tam Business Development Manager

MSYS 4480 AC Systems Winter 2015

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Rittal LCP T3+ High-availability IT cooling with no compromise

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Reducing Energy Consumption with

Recapture Capacity for Existing. and Airflow Optimization

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

White paper adaptive IT infrastructures

IT Air Conditioning Units

APC APPLICATION NOTE #146

Close-coupled cooling

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

ENCLOSURE HEAT DISSIPATION

Data Center Trends: How the Customer Drives Industry Advances and Design Development

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

Total Modular Data Centre Solutions

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Power & Cooling Considerations for Virtualized Environments

84 kw, Tier 3, Direct Expansion, 937 ft 2

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

RiMatrix S Make easy.

Data Center Optimized Controls

White Paper RiZone The Rittal Management Software for IT infrastructures

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

FREEING HPC FROM THE DATACENTRE

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Data Centre In A Box

APC APPLICATION NOTE #74

Air Containment Design Choices and Considerations

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Impact of Air Containment Systems

Green IT and Green DC

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Cooling Case Studies

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

Energy Efficient Data Centers

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Rittal RiZone Data Centre Management Software

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Trends in Data Center Energy Efficiency

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

R4 Ventures LLC White Paper

) ) page 04. page 07. page 10. page 10. page 12. page 14. page 14. page 16. page 18. page 19. page 19. page 20. page 21. page 22

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

ECOBAY: Closed loop water cooled server cabinet for data centers

Green Data Centers A Guideline

Data Center Design: Power, Cooling & Management

Enabling Business Critical Continuity for Unified Communications. Andy Liu Product Manager, Asia Pacific

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Rack cooling solutions for high density racks management, from 10 to 75 kw

Next Generation Cooling

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

HIGH DENSITY RACK COOLING CHOICES

Data center solutions for successful companies Cooling solutions

Data Center Energy Savings By the numbers

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

The Energy. David L. Moss Dell Data Center Infrastructure

Transcription:

1

Rittal Cooling Solutions Presented by Adam Tropp 2

Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3

Cooling strategies. Aisle containment. An economical solution to improve the performance of any cooling system. Benefits Increased airstream management Supply air and return air do not mix Uniform distribution of cold air Higher delta T for increased efficiency Modular, scalable, and retrofittable Can be used with perimeter-based cooling Can be used with row-based cooling 4

Cooling strategies. Aisle containment. An economical solution to improve the performance of any cooling system. When to use aisle containment Issues with bypass air Issues with hot air recirculation Issues with hot spots Issues with uneven cold air distribution Issues with maximum cooling capacity * Image from 42U.com 5

Cooling strategies. Aisle containment. Hot and cold air distribution with and without containment. 6

Cooling strategies. Aisle containment. An economical solution to improve the performance of any cooling system. Why aisle containment works Prevents hot and cold air from mixing Higher supply air temperatures Increased energy savings! Increased economizer hours Increased energy savings! Increased cooling efficiency Increased energy savings! 7

Cooling strategies. Aisle containment. An economical solution to improve the performance of any cooling system. Cold aisle containment benefits Precise, targeted cooling Consistent air temperature Eliminates hot spots No raised floor required Minimal infrastructure requirements Creates easy retrofit installations Using only doors shows increased efficiency Prevents end of row recirculation 8

Cooling strategies. Aisle containment. An economical solution to improve the performance of any cooling system. Hot aisle containment benefits Work environment is flooded with cold air Hot air can be ducted back to CRAC Increased efficiency Consistent air temperature Eliminates hot spots * Image from 42U.com 9

Cooling strategies. Aisle containment. * Image from EDS Plano TX * Image from CoreSite Los Angeles CA 10

Cooling strategies. Aisle containment. * Images from State Department Richmond VA 11

Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 12

Cooling strategies. Chimney solution. Deployment Requirements Return vents for equipment not equipped with chimneys Return extensions for CRAC units Chimney installed on rack Drop ceiling installed in data center Benefits Increased airflow efficiency Minimal hot/cold air intermixing Increased cooling capacity Hot aisle containment 13

Cooling strategies. Chimney solution. 14

Cooling strategies. Chimney solution. 15

Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 16

Cooling strategies. Airstream management. Rack-Level Air Containment Benefits Increased airflow efficiency Minimal hot/cold air intermixing Can be set into traditional raised floor Passive components No energy consumption Reduce point of failure Can accommodate blade chassis Cold aisle containment 17

Cooling strategies. Airstream management. 18

Cooling strategies. Airstream management. 19

Agenda Cooling Strategies Rittal Liquid Cooling Packages LCP Extend & LCP Passive CW LCP+ General Features LCP+ Cooling Applications Data Monitoring 20

Rittal Liquid Cooling Packages. LCP Passive CW Rear Door LCP Inline EC Open Loop LCP Hybrid EC LCP+ EC Hybrid Closed Loop 0 Tons 2.8 4.3 5.7 7.1 8.5 10.0 Tons 0 kw 10 15 20 25 30 35 kw 21

Rittal Liquid Cooling Packages. LCP Passive CW. Features Passive rear doors are designed to be installed as a replacement rear door for the racks on which they are installed A passive rear door simply has the fan system removed from the equation, allowing the server fans to do the necessary work of moving the air through the heat exchanger Maximum energy efficiency as there is no electrical power consumption Uses chilled water as the rejection medium HxWxD: 80x24x6 in. (2000x600x170 mm) 20 kw cooling capacity * Image from Sun Microsystems 22

Agenda Cooling Strategies Rittal Liquid Cooling Packages LCP Extend & LCP Passive CW LCP+ Cooling LCP+ General Features Applications Data Monitoring 23

Rittal Liquid Cooling Packages. LCP+ Cooling. Open Loop (Inline) Open front Open return More units are required to achieve N+1 Hybrid System Open front Closed return Better redundancy can be accomplished at row and room level Closed Loop Closed front Closed return Ultra high density Door release option must be used 24

Rittal Liquid Cooling Packages. LCP+ General Features. Features System Capacity: 30 kw Typical High efficiency heat exchanger developed to operate with 59 F chilled water Microprocessor controller LCD touch screen 2-way modulating valve 6 EC fans, N+1 design, hot-swappable Can be monitored remotely via web browser or SNMP via TCP/IP HxWxD: 80x12x48 in. (2000x300x1200 mm) 42 in. (1050 mm) depth also available Available in sand texture black or IBM white 25

Rittal Liquid Cooling Packages. 26

Rittal Liquid Cooling Packages. LCP+ General Features. Heat Exchanger 9.5 deep x 12.5 wide x 70 tall 27

Rittal Liquid Cooling Packages. LCP+ General Features. Electrical Design Wide input voltage range 208V, 230V, 400V EC fan technology 1 year ago: step motor technology Rated current: 6.5A 1 year ago: 11.5A Power rating: 1050W 1 year ago: 2650W 5 pole terminal block Fuses are easy accessible by opening the rear door Every unit comes high voltage tested EMC tested configuration 28

Rittal Liquid Cooling Packages. LCP+ General Features. 29

Rittal Liquid Cooling Packages. LCP+ General Features. Features Summary Auto-Temperature-Control: Cold air inlet temperature automatically controlled via integrated controller board Monitoring: Integrated controller with Rittal Basic CMC Intelligent sensor network: Fault tolerant sensors for water inlet/outlet temperatures, air inlet/outlet temperatures, water flow rates, leakage, etc. Fault tolerant controller boards and systems: In the case of electronic failures the valves will open and the fans will provide maximum airflow Alarm / events / sensor logging Three fan controller boards + one water controller board (individually fused) 30

Agenda Cooling Strategies Rittal Liquid Cooling Packages and their Energy Efficiency LCP Extend & LCP Passive CW LCP+ Cooling LCP+ General Features Applications Data Monitoring 31

Rittal Liquid Cooling Packages. Applications. Low Density (<5 kw) Application Networking switches, half-equipped server racks Products Fans Baffles Aisle Containment Mid Density (5-10 kw) Application Server and small blade servers Products LCP Inline LCP Hybrid Aisle Containment Chimney High Density (10+ kw) Application Blade servers and fully equipped server racks Products LCP Inline LCP Hybrid LCP+ Closed Loop Aisle Containment 32

Customers Using the LCP Family. 33

Agenda Cooling Strategies Rittal Liquid Cooling Packages Data Monitoring CMC III RiZone 34

Data monitoring. CMC III. CMC 3rd generation, the monitoring system for IT, building services, and industry. Monitors and measures up to 32 sensors. Enclosure and room temperature Humidity Vandalism Air flow Differential pressure Current, voltage, frequency, and energy Cooling units 35

Data monitoring. CMC III. CMC 3rd generation, the monitoring system for IT, building services, and industry. Control system for: Handles / Doors Fans Sockets Control system with: 8 digital inputs 4 relay outputs 2 energy outputs 36

Data monitoring. RiZone. RiZone is Rittal software for the monitoring and management of the IT infrastructure in data centers Power supply and reliability Cooling output and distribution Rack status Data center security (access, temperature, etc.) Efficiency and energy consumption Optimization Efficiency 37

Data monitoring. RiZone. RiZone Functions How efficient is the data center? How efficient is the UPS? How efficient is the chiller? How efficient is the cooling chain? How efficient is the power chain? What is the actual monthly / yearly power consumption? RiZone Benefits Higher visibility of systems inside the data center Historical data trending Making the data center more reliable and efficient 38

Data monitoring. RiZone. Definition of PUE/DCiE DCiE = Data Center Infrastructure Efficiency DCiE = IT Load (Server-Load) Entire Electrical Load of Data Center PUE = Power Utilization Effectiveness Entire Electrical Load of Data Center PUE = IT Load (Server-Load) PUE and Total Power Consumption are the basis for Data Center optimization. 39

Data monitoring. RiZone. Server, Infrastructure, And Total Power Consumption PUE CO 2 -Emission Power Costs 40

Any Questions? Thank you for attending and listening. 41

Rittal The System. Faster better worldwide. 42