Chemical Analysis Group Gas Chromatograph Common Cabling \ Pin-outs Document A15707

Similar documents
9 Maintenance and Repair

9 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module. InfinityLab LC Series Diode Array Detectors User Manual

Power connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123

RS-232 Connector Pin Assignments

Analog Input and Output Options for Syringe Pumps

Agilent 35900E Series II

INSTALLATION INSTRUCTIONS. This document describes the installation procedure for the SAB-400 and SAB-401 Station Audio Board.

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

Agilent 35900E. User Manual. Dual Channel Interface. Agilent Technologies

BehringerMods.com. Instructions for modification of Behringer SRC analog inputs and outputs

Connecting a Cisco Reader Module

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

Target cell RTD-set. RTD label. Epics RTD notation. Red or Golden. CPC plug slot. Old notation from 1 to 15** RTD 4, B4, R2.

MouldFlo Wiring Manual

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Installation Instructions for: Channel Thermocouple Amplifier

Clarity Controls Clarity Controls Agilent 5890 Agilent 5890

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

EFIS Horizon Cable Description

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

MOULDFLO WIRING MANUAL

Trigger I/O Manual. Trigger IO Manual. C-Cam Technologies. a division of. Vector International. Date :12/01/2011 Page 1 / 8 Version 1.

4.8 Expansion Module MAC00-FS1/FS4

the Interactive Catalog

QD V LED Tape DMX Driver

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

EFIS Horizon Cable Description

Agilent 68xx Agilent 68xx

4.7 Expansion Module MAC00-FS1/FS4

Digital Keypad Introduction

IB080QM65VA3 Part Number

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6.

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

Incremental Encoder Adapter Page 1 of 8. Description. Features. Differential Cable Driver/Receiver:

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

Configuration DanWind - HEMI

Soartronic IOIO UART interface v2e assembly manual.

PC Vision Wiring Guide

4 Connection and interface

SRI-02 Speech Recognition Interface

Allows full two way communication from any USB or RS232 port to an SPI device.

Model 1030 Expansion Unit Backplane Wiring Update

Miniature Asynchronous 4-Wire High Speed Modems

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board

J1 Harness Connector Parts (Male Pins & Plug Housings) Picture QTY Used in Manufacturer Manufacturer PN Description Molex Cross Reference

PCD 005 PolaMIX. Operation Manual

Agilent 1200 Infinity Series Universal Interface Box

FAST_EnergyCam-Communication-Interfaces.doc 7/7/2016 Page 1 of 6

721EX Access Controller Installation

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

MAGNETIC LENGTH MEASURING SYSTEM

4 Channel DMX Driver Instruction Manual

1100 Liquid Chromatograph

The watchdog is connected to the internal USB header and reset switch header on the majority of motherboards.

INSTALLATION MANUAL. Gateway EKBMSMBA EKBMSBNA

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Gold Drum HV Gold Drum HV Cable Kit (EtherCAT and CAN)

Linear Actuator Reference Manual

Thermoelectric Cooler Controller TED1000

BLU- CIF Interface Board

Additional board ZIB2-PDx-N for Plug & Drive motors PDx-N

Parrot MULTICAN for Mini cars (part 2)

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

VT-50. Linear Positioning Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

PR-32. Piezo Rotation Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

QUICK INSTALLATION. MSX-E1731 Ethernet multifunction counter system /2016

Device Configurator ECI-1

GSV-1A4 M12/2 M12/2. Highlights

Luxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F

Datasheet for PAS12 Serial Adaptor rev 1.50

QRPometer Assembly Manual Copyright 2012 David Cripe NM0S The 4 State QRP Group. Introduction

Copy Machine Reader. Installation and Setup Guide

FAST Installation (PMRS) Box Contents

4 Connection and interface

CHAPTER Wi r i n g NOTICE:

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

Product description Rev. 3 11/06/14

Miniature Asynchronous Modems

A. Functions Instruction

716 Converter. Programmable Data Converter

Warning 101 Invalid heater power for front detector, inlet, and aux 1 Warning 102 Invalid heater power for back detector, inlet, and aux 2

Introduction to Class 5 Connectivity

SAB-QS Quick Start November 9, SAB-QS Quick Start SAB-QS TRANSDUCERS 1 X4. Figure 1: SAB-QS Connector and Jumper Placement

VGA EXTENDER USER MANUAL HIT-VGA-CAT5-142WPRO HIT-VGA-CAT5-144WPRO. (Local) HIT-VGA-CAT5-R300WPRO. (Remote)

Issue : 1.1 Date : 19/1/2004. Trigger IO. C-Cam Technologies. a division of. Vector International 1 / 6

Instruction Manual. For file reference, please record the following data:

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128

Innovation First, Inc Full-Size Robot Controller Reference Guide

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

INSTALLATION INSTRUCTIONS. This document describes the installation procedures for the TMM-441 Touchscreen Master Module.

MAIN PCB (The small one)

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

4: Installing and Wiring System Components

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

QuVIS CONNECTOR PINOUT GUIDE

Wash Light User Data. User Data - Specifications Date: 01/11/2016 Page 1/7. RGBW (White 4000k) Single Colour (R,G,B,A,W)

Transcription:

Chemical Analysis Group 5890 Gas Chromatograph 5890 - Common Cabling \ Pin-outs Document A15707

300 310 Standalone Cable Configuration 320 HP 5890/Data System Cabling Diagrams 330 HP 5880/Data System Cabling Diagrams 340 HP 6890/Data System Cabling Diagrams Configuration and Cabling

???? Standalone Cable Configuration for 18594A/B Controllers 310 Figure 310-1 5890 remote connector +5V P6 P6 U16 2 1 Start In 6 Remote Connector 8 12 3 4 Ready Sense In Remote Config In 12 10 8 6 11 9 7 5 24V U5 8 K1 2 11 6 9 Ready Out 4 2 3 1 10 +5V 5 7 K2 8 Start Out 10 12/95 Configuration and Cabling 1

310 Standalone Cable Configuration for 18594A/B Controllers Pin # Signal Description 1 Remote Start In - TTL Input: expects a pulse input of greater than 5 msec from pin 1 to any ground pin. 2 Ground 3 Remote Config In - TTL Input: expects a contact closure or a jumper from pin 3 to any ground pin. When pin 3 is grounded a run can not be started by pressing START on the GC. It is waiting for a start pulse on pin 1. When using an Automatic Liquid Sampler pressing START on the GC causes the sequence to start. The run is started when the injection is made. 4 Ground 5&6 Ready Out - Two sides of a single pole, double-throw relay. When 5890 is ready then the contacts connected to 5 & 6 or open. 5 & 9 Also when 5890 is ready the contacts connected to pins 5 & 9 are closed. 7& 8 Start Out - Two sides of a normally-open relay. Contacts are closed for 50 msec to signal the start of a run. If pin 3 is connected to ground then the contacts are closed when the oven program starts. 10 Same as pin 8. 11 Ground 12 Remote Ready In - TTL input. Expects to be connected to any ground pin by an external device if that device is Not Ready. 2 Configuration and Cabling 12/95

Standalone Cable Configuration for 18594A/B Controllers 310 Figure 310-2. Using the parallel remote PC board. 5890 A or Series II Instrument 1 When connecting multiple instruments to the 5890 remote connector there are TWO main causes for running into trouble. They are the following: Example: Parallel Remote Cable (05990-6001 9) 5890 Start Out Parallel Remote PCB (05990-60320) Instrument 2 Instrument 3 Instrument 1 (+) Instrument 1 GND Instrument 2 GND Instrument 2 (+) The instruments connecting to the remote connector must use the same polarity on the remote connection (+ and - ). Even when using all HP cables, the connections need to be converted so that the instrument inputs and outputs (+ and ground connections) are the same. When using multiple instruments, it is important to be aware of which instrument is starting the run. In the case where an Automatic Liquid Sampler is being used as one of the instruments, the sampler will send the start between pin 1 and the ground of the 5890. The other instruments to be started also need to be connected to those same pins on the parallel remote PC board. 13 12/95 Configuration and Cabling 3

310 Standalone Cable Configuration for 18594A/B Controllers Asynchronous standalone cable configuration for HP G1512A controllers When configured for asynchronous standalone mode, the APG remote connector is redefined to provide independent start, stop, and readiness signals for each injector. General purposecables with spade lugs and a terminal block can be used to connect the output to an HP 35900C/D/E analog to digital(a/d) convertor configured for asynchronous operation. Figure 310-3. Typical asynchronous cable configuration. HP G1512A APG remote 35900-60670 (1) (2) Terminal block 0360-1729 35900-60670 (3) (3) 35900-60670 Remote A HP 35900C/D/E Remote B PIN # Function Color code Color code 1 GND black black (remote A&B) 2 Front injector ready in white orange (remote A) 3 Back injector ready in red orange (remote B) 4 Front injector ready out green N\C 5 Back injector ready out brown N\C 6 Front Start request blue violet (remote A) 7 Back Start request orange violet (remote B) 8 Front Start out yellow red (remote A) 9 Back Start out violet red (remote B) NOTE: (1) The remote connector on the HP G1512A is APG-compatible which means it accepts and outputs TTL levels (0 V low, +5 V high) rather than contact closures. (2) This mode is only supported when the GC is in isothermal mode. Typically this means that the GC would not have to be started and, therefore, would require no cabling. 4 Configuration and Cabling 12/95

HP 5890/Data System Cabling Diagrams 320 Figure 320-1. HP 339x INET integrator. 18594A/B or G1512A Out In Out 5890 In #3 Out 339x In, 2, 3 HPIL Cable 82167-60002 12/95 Configuration and Cabling 1

320 HP 5890/Data System Cabling Diagrams Figure 320-2. HP non-inet integrator. Remote 18594A/B 5890 Signal 3395/6 Y-Cable 03395-60540 Analog Signal 35900-60610 Figure 320-3. HP 3365 ChemStation (DOS). 18594A/B or G1512A 5890 PC ChemStation HP-IB Cable (Straight In) HP-IB Cable 8210-4654 10833B 2 Configuration and Cabling 12/95

HP 5890/Data System Cabling Diagrams 320 Figure 320-4. HP ChemStation with 18594A/B controller. 18594A/B 5890 PC ChemStation HP-IB Cable (Straight In) HP-IB Cable 8210-4654 10833B Figure 320-5. HP ChemStation with G1512A controller. G1512A 5890 #3 PC ChemStation HP-IB Cable (Straight In) 8210-4654 HP-IB Cable 10833B #3 5890/G1512A Remote Cable 35900-60700 12/95 Configuration and Cabling 3

320 HP 5890/Data System Cabling Diagrams Figure 320-6. HP MSD ChemStation. 18594A/B or G1512A 5890 PC ChemStation #3 #4 MSD, 3 HP-IB Cable (Straight In) HP-IB Cable #4 5890/MSD Remote 8210-4654 10833B 35900-60700 Figure 320-7. Standalone 18594A/B, 5890. 18594A/B 5890 Parallel Remote Cable 5890/Sampler Remote Start #3 5890 General Purpose Remote 05990-60019 18594-60570 05890-61080 Parallel Remote PCB (05990-60320) #3 Two wires typically connected to another device: Green Start Brown Ground 4 Configuration and Cabling 12/95

HP 5890/Data System Cabling Diagrams 320 Figure 320-8. Non-HP data system. G1512A 5890 #3 Y-Cable 5890/APG 2 Meter General Purpose Remote (spade lugs) G1512-60530 35900-60670 Non-HP Data System #3 5890 General Purpose Signal (spade lugs) 05890-61080 Figure 320-9. HP 35900C/D/E analog-to-digital converter. G1512A 5890 35900C/D/E #3 #3 Y-Cable G1512-60530 5890/APG APG Remote G1530-60930 5890/APG Signal Cable 35900-60610 12/95 Configuration and Cabling 5

320 HP 5890/Data System Cabling Diagrams Figure 320-10. G1512A HP 5890A with 18652A A/D box G1512A 5890A 18652A G1512-60530 01046-60204 14 6 Configuration and Cabling 12/95

HP 5880/Data System Cabling Diagrams 330 Figure 330-1 HP 5880A 5880A Mainframe Board 19321-60010 18594A/B Cable 5880A/18594A/B 19321-60510 5880A Internal Cable 19321-60500 18594A/B Controller Board 18594-60050 15 12/95 Configuration and Cabling 1

HP 6890/Data System Cabling Diagrams 340 HP 6890 GC-G1512A Figure 340-1. G1512A to HP 6890 gas chromatograph HP 6890A G1512A RS232 cable G1530-60600 APG remote cable 2M G1530-60930 12/95 Configuration and Cabling 1

340 HP 6890/Data System Cabling Diagrams HP 6890 GC-GC ChemStation-GC Automatic Liquid Sampler (ALS) HP 6890 GC-GC ChemStation-GC Automatic Liquid Sampler (ALS) Figure 340-2. HP 6890 GC 1 RS-232 2 APG remote GC ALS 3 HP-IB 4 RS-232 GC ChemStation Modem Number HP part no. and description 1 G1530-60600, RS-232 cable, 9-pin female/9-pin female 2 G1530-60930, APG remote cable, 2-m, 9-pin male/9-pin male 3 10833B-2310,2-m HP-IB cable 4 HP 24542M (also 24540-80012), RS-232 cable 2 Configuration and Cabling 12/95

HP 6890/Data System Cabling Diagrams 340 HP 6890 GC-HP Mass Selective Detector-GC ChemStation-GC ALS HP 6890 GC-HP Mass Selective Detector-GC ChemStation-GC ALS Figure 340-3. 1 APG remote MSD HP 6890 GC 3 RS-232 4 APG remote GC ALS 2 HP-IB 2 HP-IB GC ChemStation Number HP part no. and description 1 G1530-60930, APG remote cable, 2-m, 9-pin male/9-pin male 2 10833B-2310,2-m HP-IB cable 3 G1530-60600, RS-232 cable, 2-m, 9-pin female/9-pin female 4 G1530-60930, APG remote cable, 2-m, 9-pin male/9-pin male 12/95 Configuration and Cabling 3

340 HP 6890/Data System Cabling Diagrams HP 6890 GC-GC ALS-Non-HP Data System HP 6890 GC-GC ALS-Non-HP Data System Figure 340-4. HP 6890 GC 1 RS-232 2 APG remote GC ALS 3 APG remote 4 External event Spade lug termination Number HP part no. and description 1 G1530-60600, 2-m RS-232 cable, 9-pin female/9-pin female 2 G1530-60930, 2-m APG remote cable, 9-pin male/9-pin male 3 35900-60670, General use APG remote cable, 9-pin male/spade lugs 4 G1530-60590, External event cable, 8-pin/spade lugs HP 35900-60670 APG remote cable spade lug identification Connector 1 Signal Connector 2 9 pin (male) name spade lugs 1 GND Black 2 Prepare White 3 Start Red 4 Shut down Green 5 Reserved Brown 6 Power on Blue 7 Ready Orange 8 Stop Yellow 9 Start Request Violet HP G1530-60590 external event cable spade lug identification Pin Color Signal 1 Yellow 24 V Out 1 2 Black 24 V Out 2 3 Red Ground 4 White Ground 5 Orange Contact 1 6 Green Contact 1 7 Brown Contact 2 8 Blue Contact 2 4 Configuration and Cabling 12/95

HP 6890/Data System Cabling Diagrams 340 HP 6890 GC-HP 3396B/C or HP 3397A Integrator-GC ALS-Modem HP 6890 GC-HP 3396B/C or HP 3397A Integrator-GC ALS-Modem Figure 340-5. Modem 4 Modem 1 RS-232 HP 6890 GC 2 APG remote GC ALS 3 INET INET Integrator Number HP part no. and description 1 G1530-60600, 2-m RS-232 cable, 9-pin female/9-pin female 2 G1530-60930, 2-m APG remote cable, 9-pin male/9-pin male 3 Two 82167-60003, 5-m INET cables 4 G1530-61120, Modem cable, 9-pin female/9-pin male OR 24540-80012 (also HP 24542M), Modem cable 9-pin female/25-pin male 12/95 Configuration and Cabling 5

340 HP 6890/Data System Cabling Diagrams HP 6890 GC-HP 3395A/3396B Integrator-GC ALS HP 6890 GC-HP 3395A/3396B Integrator-GC ALS Figure 340-6. 1 RS-232 HP 6890 GC 2 APG remote GC ALS 3 APG remote 4 Analog HP 3395A/3396B Integrator Number HP part no. and description 1 G1530-60600, 2-m RS-232 cable, 9-pin female/9-pin female 2 G1530-60930, 2-m APG remote cable, 9-pin male/9-pin male 3 03396-61020, APG remote cable, 9-pin/15-pin 4 G1530-60570, Analog cable, 2 m, 6-pin 6 Configuration and Cabling 12/95

HP 6890/Data System Cabling Diagrams 340 HP 6890 GC-HP 3395B/3396C or HP 3397A Integrator-GC ALS HP 6890 GC-HP 3395B/3396C or HP 3397A Integrator-GC ALS Figure 340-7. 1 RS-232 HP 6890 GC 2 APG remote GC ALS 3 APG remote 4 Analog HP 3395B/3396C Integrator Number HP part no. and description 1 G1530-60600, 2-m RS-232 cable, 9-pin female/9-pin female 2 G1530-60930, 2-m APG remote cable, 9-pin male/9-pin male 3 03396-61010, APG remote cable, 9-pin/15-pin 4 G1530-60570, Analog cable, 2 m, 6-pin 12/95 Configuration and Cabling 7

340 HP 6890/Data System Cabling Diagrams HP 6890 GC-HP 35900C/D/or E Analog-to-Digital Converter-GC ALS HP 6890 GC-HP 35900C/D/or E Analog-to-Digital Converter-GC ALS Figure 340-8. 1 RS-232 HP 6890 GC 2 APG remote GC ALS 3 APG remote 4 Analog 35900 C/D/E A/D converter Number HP part no. and description 1 G1530-60600, 2-m RS-232 cable, 9-pin female/9-pin female 2 G1530-60930, 2-m APG remote cable, 9-pin male/9-pin male 3 G1530-60930, APG remote, 2-m, 9-pin male/9-pin male 4 G1530-60570, Analog cable, 2-m, 6-pin 16 8 Configuration and Cabling 12/95