progecad NLM User Guide

Similar documents
progecad NLM User Guide Rel. 10.1

Internet Key Administration

ACD SMR User's Guide. Table of Contents

Windows user guide for version 3.3

HR-Lite Database & Web Service Setup Guide

IT Access Portal User Guide (Employees)

WCM 6.0 Pro MS/SP Software Recovery Installation Guide

Licensing and Activation

ALMS Desktop Application User Manual

CONTENTS I. DEVICE SETUP II. INSTALLATION III. UNINSTALL RETAIL MODE

Practice and Review Activities Software

10ZiG Technology. Thin Desktop Quick Start Guide

R9.7 erwin License Server:

This chapter provides an overview of user access management and Segment Management pods in the SNTC portal.

Schneider Electric Floating License Manager

Guest Management Software V2.0.2 Release Notes

ModeChanger

Web Intelligence Rich Client Getting Started Business Objects 4.1

WinDSX New Installations

FASTT Math Next Generation Installation Guide

Deposit Wizard TellerScan Installation Guide

Operating Manual. OnDemand3D Server. and OnDemand3D Server Management Studio. OnDemand3D Project Viewer

Upgrade Instructions. Note

READ 180 Next Generation Installation Guide

Scholastic Reading Inventory Installation Guide

READ 180 Next Generation Installation Guide

Managing GSS Devices from the GUI

FASTT Math Installation Guide

Configuring Microsoft Outlook to Connect to Hosted Exchange Service

The Reading Inventory Installation Guide

HOW-TO GUIDE: How to install Mazda Toolbox? For Windows HOW-TO GUIDE: How to install Mazda Toolbox? For OSX (Mac) HOW-TO GUIDE: How to start using

Guide to your CGIAR Network account Self Service tool

Apptix Online Backup by Mozy User Guide

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2

Backup App V7. Quick Start Guide for Windows

Setting Up and Using WebDrive

System 44 Installation Guide

System 44 Next Generation Installation Guide

Procedure to Upgrade Verizon FiOS Router and Configure Xbox 360 to connect with Microsoft USB WiFi Adapter

1. NVR Connection Diagram Wizard Setup Access System Using Mobile Device Access System Using PC Client Software 5

RMX 2000/4000 MPMx Migration Procedure

User Manual PDUTracker

Oracle Connector for Outlook Clinic Version

Backup App v7. Quick Start Guide for Windows

User Manual v

Getting Started with Outlook Web App (OWA)

Copyright 2016 ForensicSoft Inc. SAFE Block Win10 To Go User s Guide

CONTENTS I. DEVICE SETUP II. INSTALLATION III. UNINSTALL RETAIL MODE

RMX 2000 MPM to MPM+ Migration Procedure

Network DK2 DESkey Installation Guide

Licensing for BarTender s Automation Editions

Production Assistance for Cellular Therapies (PACT) PACT Application System User s Guide

RMX 2000/4000 MPMx Migration Procedure

BOCI Securities Limited Security Token User Guide (for Securities Account) Content

Upgrading Print Director to PCS Director

Merchant Online Reporting System (MORS) Login with OTP

29 March 2017 SECURITY SERVER INSTALLATION GUIDE

Updating Simplify3D from V 3.x to V 4

FASTT Math Installation Guide

Moving Sage BusinessWorks to a new location

MultiSite Manager. User Guide

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10

GIGATRAK HANDHELD INSTALL AND SYNC

Deposit Wizard Panini Installation Guide

Fencing Time Version 4.3

TROUBLESHOOTING GUIDE

Getting Started Manual

Schneider Electric License Manager

AVG INTERNET SECURITY 8.5 Installation, Configuration and Use for AARP Tax-Aide

PaperStream Capture Pro Installation Guide

Virtual Desktop Infrastructure Setup for Windows 10

INSTALLATION AND USER S GUIDE OfficeCalendar for Microsoft Outlook

Grandstream Networks, Inc. IPVideoTalk Cloud Conferencing System IPVideoTalk Portal User Guide

Minimum System Requirements The following are the minimum system requirements needed to run and install Premium Pro Enterprise:

FASTT Math Installation Guide

Contents Overview... 2 Part I Connecting to the VPN via Windows OS Accessing the Site with the View Client Installing...

Appserv Internal Desktop Access Mac OS Device with Safari Browser. Enter your Appserv username and password to sign in to the Website

EvaluNet XT v1.2. Setup Guide

MassTransit Server Installation Guide for Windows

IQCare Troubleshooting Guide

System 44 Installation Guide

Set up your computer to sync your OneDrive for Business files in Office 365

Password Reset Utility. Configuration

Epson Projector Management Operation Guide

Installing the WD My Cloud Backup Device

Using the Vita Group Citrix Portal

Guest Management Software (GMS) v Release Notes

HORTICOPIA Professional

Digital Signage Station

v5: How to restore Exchange databases

Fiery Command WorkStation 5.8 with Fiery Extended Applications 4.4

BIZPRAC 12 GUIDE RE-INSTALLATION

This Quick Start describes how to use Bocconi Cloud Service, called Filr in the rest of the document, from your Windows desktop.

STATISTICA VERSION 10 STATISTICA MONITORING AND ALERTING SERVER (MAS) INSTALLATION INSTRUCTIONS

SolarPower Pro. User s Manual. Management Software for Solar Inverter

UNINSTALL THE BPR FOR WIN-Rev2.bprm

Display Manager Version 1.0

Installing Cash Register Express

Secure Single Sign On with FingerTec OFIS

Grants Programs for Universities and Research Centers. User Manual for Registration and Create Profile

Transcription:

progecad NLM User Guide Rel. 18.1

Table of Contents Table of Contents... 2 Introduction... 3 How to start... 3 progecad NLM Server Installation... 3 progecad NLM Server Registration... 3 Licenses Addition and Activation... 4 progecad Installation and Usage... 4 How to obtain a Take-Away License... 4 Server control from other PC... 5 Server Management and Configuration Change... 5 Access to Administration Panel... 5 Administration Panel... 5 License Manager... 5 Server Settings... 6 Migrating NLM Server... 8 2

Introduction The progecad NLM version (Network License Manager) allows to run concurrently a number of progecad copies corresponding to the number of licenses purchased on various workstations within the same network (LAN o Internet). The NLM version consists of two parts: progecad clients, that can be installed on the unlimited number of workstations. The maximum number of progecad copies for concurrent use corresponds to the number of purchased licenses. The NLM Server software, that can be installed on any PC of the network, including progecad workstations. NLM Server manages licenses and assigns them to the users who want to use progecad. It is recommended to install NLM Server on a PC with Internet access for further registration and activation of licenses. Notice that you need only one installation of NLM Server to set your progecad network environment and manage your NLM licenses. NLM Server, lacking GUI, can be monitored and managed from any PC on the network via the NLM Monitor software (included in the NLM Server Installation). The NLM Server Management provides the possibility to add eventually purchased new licenses, remove licenses or monitor their state (availability, the user who works with the software, expiration, etc). progecad users working within the network can immediately obtain a license from the Server, valid during the period of progecad, or they can request a Take-Away license that will allow them to work on a workstation out of this network for a necessary period of time (up to 30 days maximum). Note: Each Take-Away license reduces the number of licenses available on the network by one for the Take- Away license duration period or till the moment of the license release. How to start progecad NLM Server Installation To install NLM Server, start the file nlmserver2018proeng.exe on a network PC shared with all the PCs where progecad is going to be used, and follow instructions popped up on the screen. progecad NLM Server Registration It is necessary to register NLM Server to be able to use it. The NLM Monitor, installed together with NLM Server, will be automatically launched at the end of installation. It is also possible to launch NLM Monitor later on from the Start menu just clicking on NLM Server Monitor icon in Windows 8 or going to All programs (or All apps) > progecad NLM Server 2018 Professional English > progecad NLM Server 2018 - English Monitor in previous versions of Windows or in Windows 10. Once opened, NLM Monitor will connect to NLM Server and ask to complete registration. Select the OK button and the NLM Server Registration Form will appear. When the form is filled out, press the Activate button, the program will try to carry out the Live registration, that is a quick registration via Internet. In 3

case your PC is not connected to the Internet, it will be necessary to proceed with the e-mail registration following the offered instructions. Licenses Addition and Activation When the Server has been registered, there will appear the dialog allowing to activate purchased licenses (see figure on the side). Every license has its own serial number starting with NLM. If you already have license serial numbers, insert these serial numbers in the dialog box and press Add and Activate. The activation method is similar to the Server registration method (Live when there is Internet access, otherwise via e-mail). It is also possible to add and activate licenses later on from the Start menu. Once licenses are added and activated, the Server is ready for use! progecad Installation and Usage Install progecad on all the PCs where you are going to use the software and carry out registration. This operation consists of the following steps: Choose Register in the dialog box that pops up upon progecad Startup. Insert the serial number that was assigned during the NLM Server registration. This number can be retrieved at any time through NLM Monitor, where it is visualized in the upper left corner of the window (see figure on the side). If the client s automatic configuration is enabled through NLM Server, this last step can be omitted by accepting the server prompt that will show up during this procedure. Type Name, Surname and the company name. Once registered, progecad is ready for use and the software will ask for the IP address of the PC where NLM Server is installed and for the clients port (if not detected automatically). If the procedure has been carried out correctly, progecad will make a license request to NLM Server. After verification of its availability, NLM Server will assign the license allowing the launch of the software. To learn the IP address of the server, execute the command ipconfig from the command line prompt on the computer with NLM Server. How to obtain a Take-Away License You can work not only connected to NLM Server, but you can also obtain a license for some period of time that allows you to work disconnected from NLM Server. This type of license is called a Take-Away license. To get a Take-Away license, you must launch the program NLM TakeAway that you can find in the progecad Center placed in the Start Menu (going to All programs (or All apps) > progecad 2018 Professional (x86/x64) - 4

English > progecad Center 2018 Professional English (x86/x64). At the top of the window you will see your current license type (no license/connected to the server/take- Away license). If you already have a Take-Away license and you are connected to the server, you can release the license before its expiration. If you are connected to the server, you can obtain a Take-Away license, by choosing the number of days you want to work offline, and specifying the Take-Away password (set by your NLM Server Administrator). Server control from other PC It is possible to monitor and control the server from any other PC on the same network. For that you need to copy the NLMServerMonitor folder from the PC with NLM Server to the desired computer. Then run NLM Monitor and press the Monitor Configuration button. Indicate in the popped up dialog the IP address of the PC where NLM Server is installed and a configured port to communicate with Monitors. Server Management and Configuration Change Access to Administration Panel Once NLM Monitor is connected to NLM Server, you can access Administration Panel pressing the Administrate the Server button and inserting the NLM Server Administration Password. Upon the NLM Server installation the default password is created. It is possible to change it later on from Administration Panel. If you forget the Administration Password, start NLM Monitor from the PC with NLM Server, making sure that in the NLM Monitor configurations the Server IP address is set to 127.0.0.1. Then connect to the server, press the Administrate the Server button and proceed to the default password re-setting. Administration Panel Upon the password insertion the Administration Panel opens, offering two main tabs: License Manager and Server Settings License Manager The License Manager dialog offers the following operations: Add and activate new licenses To add new licenses, insert serial numbers of new licenses purchased in the appropriate field (one serial number at a line), then press the Add and Activate Licenses button. The Server will add new licenses and will proceed to their immediate activation. 5

Activate Licenses This list presents non-activated licenses; the activation of these licenses was not possible at the moment when they were added. To activate these licenses, it is necessary to select (all licenses or some of them according to your need) and press the Activate Selected Licenses button. If the Server finds Internet connection, it will immediately proceed to the automatic activation, otherwise you will be asked to proceed with the e- mail activation. License E-mail Activation Once the e-mail activation requested, you will receive an e-mail response with an activation file attached. Pressing the E-Mail Activation button, the dialog box will appear. Select the file received as attachment to the e-mail. Delete non-activated licenses You can delete non-activated or expired licenses, that you do not want to activate any more, simply selecting and pressing the Delete Licenses button. Release Active Licenses This list enumerates active licenses currently not in use, and consequently available for being released. This operation is necessary when you want to re-activate the licenses on another Server. Note: To release licenses correctly, the Server must be connected to the internet. This operation is not provided via e-mail. If no Internet access is available, you can still proceed with the release but in this case the licenses will be simply removed from the server without being actually released. As a result new eventual activations will be generating an alert message. Server Settings The NLM Server Settings dialog allows to control and modify all the options and settings in regard to the NLM Server functionalities, among which: Clients Port Number The port number to communicate with network clients. When a port number happens to be changed, the users eventually connected to the server will become disconnected and they would have to insert a new port number in their settings. If the change of a port number fails (for example, it is already used by some other program), then NLM Server will turn back to the old port. Monitor Port Number The port number to communicate with network Monitors. When a Monitor Port Number happens to be changed, all the Monitors connected to the server will become disconnected and a new port number would have to be inserted in the configuration. If the change of a port number fails (for example, it is already used by some other program), then NLM Server will turn back to the old port. In any way, the Monitor, where the port has been changed, will automatically set a new value in its configuration. So, in case the 6

change of a port is successful, just press the Connect to the Server button and you will be connected to the server using the new port. Meanwhile the port number on all other Monitors will have to be changed manually in Monitor Configuration. Note: If the connection to the server was not possible, the server probably failed to start on a new port and so reset the previous value. You should indicate the old port number in Monitor Configuration. In this way all other Monitors will not have to present any modification. User Timeout in minutes Set a time limit (in minutes) when the license is conserved even if the communication from the client is lacking(during this period the user can work locally even without access to the Server). The higher timeout value, the better stability for the users (work longer in case of net malfunctioning), but at the same time the worse flexibility (if some user fails to communicate with the server, has no way to release his license, so no other user will be able to take this license). Administrator Password The password necessary to access Administration Panel. Attention! When changing password, you are not asked for confirmation of an inserted password, so it is strongly recommended, before saving the new settings, to verify if the new password corresponds to the one you were intending, pressing the Show/Hide button for its visualization. Who can view Client Names in the License List? If you select the All Monitors option, all Monitors will be able to see Names and Surnames of those users who possess the corresponding licenses. With the Only Local Host Monitors option the users names and surnames will be hidden to all Monitors, except for one started on the PC where the Server is installed and connected to the Server with the localhost address (127.0.0.1). Minimum License Span in days The minimum number of days for granting a Take-Away license Maximum License Span in days The maximum number of days for granting a Take-Away license License Request Password The password necessary to obtain a Take-Away license from the Server. Attention! When changing password, you are not asked for confirmation of an inserted password, so it is strongly recommended, before saving the new settings, to verify if the new password corresponds to the one you were intending, pressing the Show/Hide button for its visualization. Start Server / Suspend Server The command to start or suspend the Server. As far as Users are concerned, to suspend the Server is equivalent to switch it off. All Users will be disconnected, and the Server will stop functioning on the clients port, becoming inaccessible (the users who were connected will be able to continue working even without Server for the time set by Timeout); as far as Monitors are concerned, nothing will be changed and they will continue functioning in the same mode. Starting the server the clients port will be reset. Restore Default Settings Turns the settings (except the two passwords) back to the default values. Attention! The Restore Default Settings function only modifies the values in the corresponding fields, but does not save them! To save the default settings, it is necessary to use the save settings command. In case you prefer to reject the default settings, just close Administration Panel down without saving. 7

Save Settings Saves all modified settings and closes down Administration Panel. Migrating NLM Server If you need to move NLM Server, first of all, connect to NLM Server by clicking the button Connect to Server in the NLM Monitor window and make sure to release all available NLM licenses: In NLM Monitor, click the button Administrate the Server to open NLM Server Administration Panel (you need to login to the Panel by using your password if the default one was changed) In Administration Panel under the tab License Manager > Activated Free Licenses select all available NLM licences by pressing the button Select All Press the enabled button Release Selected Licenses Press the button Close Administration Panel and exit NLM Monitor Now you can proceed to NLM Server transfer: Uninstall NLM Server Reinstall NLM Server on a new machine, activate NLM Server and NLM licenses as if you were doing it for the first time, following the same procedure. Repeat registration for all Clients by going to progecad Center > Register progecad. If the Server is located on the same LAN network and the automated registration procedure option is enabled, then the registration process will be through in few clicks. If the automated registration procedure option is disabled, then during the registration procedure you will be prompted to indicate the new serial number associated with NLM Server. On progecad start, not finding the old IP address and Port number (progecad stored the previous IP and Port), the program will ask for a new IP address. These data, IP address and Port number, can be reset in any moment from progecad Center -> Utility -> NLM Settings. 8