Power Connections: Basic Wiring:

Similar documents
INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Firmware Manual - EC Series Drives

EQ5 SERIES Quick Start Guide for Constant Torque Applications

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

Unidrive M400 (Frame 1 to 4) Quick Start Guide

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

1-1 AC DRIVE OVERVIEW EXERCISE OBJECTIVE

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

Basic Drive Programming PowerFlex 755 Basic Start Up

LS M100 Frequency Inverter Easy Start Guide

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

Display / Adjustment Options VW3-A16101, VW3-A16102, VW3-A16103

Installation Instructions

INSTALLATION AND OPERATION MANUAL KBDF SERIES

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

INSTALLATION AND OPERATION MANUAL KBMK SERIES. Adjustable Frequency Drives for 1/8 HP thru 1 HP 3-Phase AC Motors Rated VAC, 50/60 Hz

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

QUICK REFERENCE GUIDE

TR150 DRIVE STANDARD FEATURES

ABB Micro drives. User s manual ACS255 drives ( hp) (115V-480V Variants)

Quick Start Guide For GVX9000 AF Drives

SED2 Variable Frequency Drives

SECTION VARIABLE FREQUENCY DRIVES

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 4

Bulletin 1329I Integrated Drive/Motor (Series B)

SMVector Additional I/O Module Installation and Operation Manual

Easy Start Guide. Parker SSD Drives 650 Series Frequency Inverter available from Parker.InverterDrive.com

User Guide VLT Parallel Drive Modules

SMVector Additional I/O Module Installation and Operation Manual

VS1MX AC Extreme Duty Microdrive

WARNING UNINTENDED EQUIPMENT OPERATION

1. Introduction About the Vacon 5X drive Identifying the drive by model number Drive model numbers...7

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

GV3000/SE AC Drive Hardware Reference, Installation, and Troubleshooting VAC Version 6.04

Bulletin 1336 Adjustable Frequency AC Drive 1336 B075 B C075 C VT B075 B150. Troubleshooting Guide

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

MCH Series Drives Metasys N2 Communications Guide

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD Instruction Manual. Publication P972E Issue 08/09

VS1ST AC Microdrive. 2/11 Installation & Operating Manual MN767

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

PowerFlex 400 AC Drive Guide Specification

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

SP500 AC Drive Installation and Operation Manual Version 3.1

MC3000 Series Drives Metasys N2 Communications Guide

Q9 ASD LOW VOLTAGE DRIVE

Profibus DP Expansion Board

SPEEDMASTER SM SERIES SUB-MICRO INVERTERS

VS1MX AC Extreme Duty Microdrive

Altivar 21 Programming and Operation Guide

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

VS1ST AC Microdrive. 04/13 Installation & Operating Manual MN767

SV9000 AF DRIVES SVReady User Manual. Pump and Fan Control Application

MANUAL PLC1.01 BOARD

AD-7830 Servo Amplifier

Instruction Sheet WPC 2000 Option 1

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 3

PowerFlex 40 Sample Specification

SINAMICS IOP. Intelligent Operator Panel. Operating Instructions February 2009 SINAMICS

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

SUPPLEMENTAL MANUAL FACTORY-INSTALLED LENZE AC TECH VARIABLE FREQUENCY DRIVES (VFD) IN RENEWAIRE (ERV) VENTILATORS TABLE OF CONTENTS

User s Manual E-Clipse Bypass Configurations (BCR, BDR, VCR, or VDR) for ACH550 Drives (1 400 HP)

DIGITAL GEAR PUMP DRIVE OPERATING MANUAL: Model No.

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

VS1ST AC Microdrive. 2/08 Installation & Operating Manual MN767

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Resolver to Digital Expansion Board

Zenith DS9000 Dispensing System

Installation & Operation Manual KBVF SERIES. Chassis / IP-20 AC Drives

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

18805 Adams Ct., #110 ~ Morgan Hill, CA 95037, USA ~ ~ ~

GV3000/SE AC Drive 1-20 HP, 230V AC

AP Series Variable Frequency Drives Operation & Installation Manual

Your TDC Package Should Contain:

Allen-Bradley 1397 L11 I/O Expansion Card

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 7.5kW, 0.33hp to 10hp

QD:CT Plus & QD:VT Installation and Operating Instructions

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

160 AA02SF1 AF DS-D17

ABB Spindle Drive Installation and Quick-Start User Manual

VS1ST AC Microdrive. 8/08 Installation & Operating Manual MN767

Technical Bulletin (TB-0040)

STEP MOTOR DRIVER SMD-4.2DIN

CBM-105FP Troubleshooting

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

smd - frequency inverter 0.37 kw 22 kw

ACH550 Product Overview

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

Transcription:

Power Connections: The CFW10 Quick Start Guide is a supplement to help get the CFW10 started quickly using the most common installation and configuration options. This CFW10 Quick Start Guide is not meant to replace the CFW10 User s Manual. For detailed instructions, safety precautions, proper mounting, installation, configuration, and operation please refer to the CFW10 User s Guide. Warning: Only qualified personnel should plan or implement the installation, start-up, operation and maintenance of this equipment. Personnel must read the entire CFW10 User s Guide before attempting to install, operate or troubleshoot the CFW10. Figure 1 - Power and Grounding Connections Basic Wiring: 1. Mount the CFW10 to a flat vertical surface. 2. Connect the incoming single phase power leads to the L/L1 and N/L2 connections on the power terminal and connect the GROUND lead to PE on the power terminal (Refer to Figure 1). 3. Connect the motor leads to the U, V, and W connections on the power terminal and connect the GROUND lead to PE on the power terminal (Refer to Figure 1). Note: Only three-phase AC motors can be used. 4. Apply power to the CFW10 drive. The drive will run self diagnostics and if no problems are found it will display rdy. Note: New CFW10 drives are shipped with parameters preset to factory defaults. If you need to reload factory defaults at any time, first set password parameter P000=5 then set factory default parameter P204=5. Keypad Start/Stop (Local Mode): This operation mode is recommended for users who are operating the drive for the first time without additional control connections. 1. Press the start key. The motor will accelerate from 0.0 to 3.00 Hz (minimum speed P133), in the clockwise direction. Note: If the direction of rotation is not correct, switch off the drive and wait until the capacitors discharge completely (as long as 10 minutes) and then swap any two wires at the motor output. 2. Press the key and hold it to increase motor speed (maximum speed P134). Note: On Plus versions use the keypad potentiometer located on the bottom right of the keypad to adjust speed. 3. Press the stop key. The motor decelerates to 0.0Hz and stops with a display of rdy. 2

Keypad Operation and Parameter Setup: LED Display indicates fault codes, inverter status, parameter number and value. Display rdy Sub dcb EPP Figure 2 Keypad Operation Display Description Drive is ready to be enabled. Power supply voltage too low for drive operation. Drive in DC braking mode. Drive is loading factory setting. Red LED When lit the display indicates the parameter number. Green LED When lit the display indicates the parameter value. Key Description Switches the display between parameter number and content. Increases Speed (frequency) and Parameter number/content Decreases Speed and Parameter number/content Starts/Stops the drive via the acceleration/deceleration ramp and resets the drive after a fault. Note: Plus versions of the CFW10 have a speed potentiometer on the lower right side of the keypad which is used to increase/decrease speed. The CFW10 does not require parameter programming prior to start up and is ready to operate with the factory default settings. A parameter example is given below to familiarize the user with parameter navigation, viewing, and programming. Action LED Display Description After power is applied to the drive, the display shows Drive is ready to be started. the following message. Press the key to view parameter number. The red LED on the keypad will light to indicate parameter number. Press the or arrow keys to select a parameter. Press the key to view the value of the parameter. The green LED on the keypad will light to indicate parameter value. Press the or arrow keys to change the parameter value. Press the key to store the new value. Repeat this procedure for other parameters that may need to be changed. Select the desired parameter. This example uses parameter number P100 (Acceleration Time). This is the numerical value associated with the parameter. For this example then P100=5.0 therefore the acceleration time is set for 5 seconds. Set the new desired value. In this example the acceleration time has been increased to 6.1 seconds. Note: To change parameter values you must first set the access parameter P000=5. Some parameter changes require the drive be stopped first. The new value for P100 (acceleration time) is stored in memory. 3

Keypad Start/Stop (Local Mode) continued: 4. If parameters were accessed or changed under Parameter Setup then the last parameter number or value will be displayed. Scroll up or down with the or keys to the read only parameter P002 (Frequency Proportional Value for Speed) and press the key to see the value. 5. Return to step 1 and press the start key to start the drive. Local/Remote Modes: In the previous section the drive was operated from the keypad (Local Mode). If you wish to operate in remote mode you will need to add an external Local/Remote switch. Note: To control speed in remote mode a speed potentiometer (figure 5) can be added or the up and down arrow keys on the keypad can be used by setting P222=0. Plus versions can use the keypad speed potentiometer by setting P222=3. Parameters: Confirm DI3 is set to Local/Remote (P265=6). Control Wiring: Local/Remote switch is N.O (normally open) and is connected as shown in Figure 3. 2 Wire Start/Stop (Remote Mode): Parameters: 1. Confirm DI4 is set to START/STOP (P266=4). 2. Set P229=1 (DIx) if you want the 2 wire control in local mode. 3. Confirm P230=1 (DIx) if you want the 2 wire control in remote mode. Control Wiring: Verify there is a jumper between XC1-1 (general enable) and XC1-5 or the drive will not work. Jumper can be eliminated if DI1 is set to No Function (P263=0). Start/Stop switch is N.O. (normally open) and is connected as shown in Figure 3. Figure 3 Local/Remote and 2 Wire Start/Stop 4

3 Wire Start/Stop (Remote Mode): Parameters: 1. Set DI1 (Start) to On (P263=13). See note below. 2. Set DI2 (Stop) to Off (P264=14). 3. Set DI4 to No function (P266=0). 4. Set P229=1 (DIx) if you want the 3 wire control in local mode. 5. Confirm P230=1 (DIx) if you want the 3 wire control in remote mode. Control Wiring: Start and Stop are momentary push button switches and are connected as shown in Figure 4. Start is a N.O. (normally open) contact and Stop is a N.C. (normally closed) contact. Note: When initially setting DI1 to START (P263=13) an E24 (programming) error will occur until DI2 is set to STOP (P264=14). Figure 4-3 Wire Start/Stop Operation from Remote Analog Input (Speed Pot): Parameters: 1. Confirm P222=1 (Remote Speed Ref=AI1) Control Wiring: Speed Pot value must be 5KΩ but 10KΩ at 2W and is connected as shown in Figure 5. Fault Codes: Figure 5 Analog Input with Speed Pot When a fault is detected, the drive is disabled and the Fault Code is displayed. (Example E01). To restart the drive after a fault has occurred, the drive must be reset. Resetting the drive can be done by disconnecting and reapplying AC power (power-on reset), by pressing the O/RESET key (manual reset), automatic reset, or via digital inputs. For details on Reset and a full list and description of Fault Codes please read Chapter 7 in the CFW10 User s Guide. 5

Parameters Example: The following is a typical list of parameter changes that may be needed in addition to the factory default settings (P204=5). P000=5 Parameter Access (5 = Password) P204=5 Loads Factory Default P100=5 Acceleration Time = 5 seconds P101=10 Deceleration Time = 10 seconds P133=3.00 Minimum Frequency = 3.00 Hz P134=60.00 Maximum Frequency 60.00 Hz Local/Remote parameters allow the drive to be set up to operate from Keypad, Remote Terminal, or a programmed combination of keypad and terminal inputs. P221 Local Speed Reference Selection P222 Remote Speed Reference Selection P229 Local Command Selection P230 Remote Command Selection P231 Forward/Reverse Selection Read Only Parameters (P002 P040) can be used for monitoring and troubleshooting. For a full list and description please read the CFW10 User s Guide. By monitoring certain read only parameters, drive operational values can be determined without the use of any other test equipment. P002 Frequency Proportional Value (Speed) P003 Motor Current P004 used to monitor DC Link Voltage. P005 Motor Frequency P007 Motor Output Voltage P014 Last fault These are just a few examples of drive set-up and parameters. Please read the CFW10 User s Guide for additional information. Publication Numer QS005CFW10 6