Bus Bar Protection Relay B-PRO 4000

Similar documents
Transformer Protection Relay

Power System Monitoring Recorder TESLA 3000

Power System Monitoring Recorder

Power System Monitoring Recorder. Product Overview. 10 Year WARRANTY

MINER-S Station Controller

Scout-S Station Controller

MINER-S Station Controller. Substation Automation

FL MC 2000E (SM40) LC

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Communication Gateway COM 610. Product Guide

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

RT4F-110V/25A RECTIFIER

extending the boundaries of technology evolution of proven technology FEATURES

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

RT4F-48V/50A-WAC RECTIFIER

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

TM221M16R controller M IO relay

TM221CE40R controller M IO relay Ethernet

Relion 611 series. 611 series Type Test Certificate

TM221ME32TK controller M IO transistor PNP Ethernet

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

RT12-240V/2.4kW Rectifier Specification

SM100. On-Line Switchgear Condition Monitoring

SEL-2730M 24-Port Managed Ethernet Switch

InteliPro. Protection Relay for Parallel Applications. Technical Specification

RT4F-120V/20A-WAC RECTIFIER

FP-5000 Feeder Protection

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

TM221M32TK controller M IO transistor PNP

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

TM221CE24R controller M IO relay Ethernet

Protection Relays PHASE & RESIDUAL OVERCURRENT

MULTILINK ML2400 Guideform Specification

EPM Multilin ADVANCED POWER QUALITY METER. High Performance Power Quality and Transient Recorder Meter KEY BENEFITS APPLICATIONS FEATURES

Rugged MediaConverter

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

PMC 530 Series Advanced Multifunction Meter

GRD130 - FEATURES APPLICATION

TM221M16TG controller M IO transistor PNP spring

CSPS-6K (Shelf Type) POWER you need POWER SHELF

RT4B-110V/12A RECTIFIER

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Designed For Reliability Manufactured To Last

TM221ME16T controller M IO transistor PNP Ethernet

RT7-48V/6kW Specification

TM221CE40T controller M IO transistor PNP Ethernet

Type VRLTC tap changer

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Zero-Packet-Loss in the Substation. Marzio P. Pozzuoli RuggedCom Inc. Industrial Strength Networks Woodbridge, Ontario, Canada

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

TM221CE24T controller M IO transistor PNP Ethernet

Providing the missing piece in your Condition Based Monitoring platform

M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS

SAMSUNG ELECTRO-MECHANICS CO., LTD

TM221CE40R controller M IO relay Ethernet

Table 1 Relay Model and Function

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

M-2001D DIGITAL TAPCHANGER CONTROL SUGGESTED SPECIFICATIONS

TM241CE24T controller M IO transistor PNP Ethernet

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

A low-cost, economical solution for distribution feeder protection

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

TM241CE24U controller M IO transistor NPN Ethernet

APR64(Rackable) APR64P (Portable)

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Current Fault Signatures and Analysis Auto-calibrating metrology means the meter maintains its accuracy over temperature and time

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available.

DRTS 33. The new generation of advanced three phase relay test set

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Universal Power Supplies

Safety Standards. Model Number: Unit Weight:

Series Watt DC Power Supplies

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Feeder/ Motor Protection Relay VAMP 40

Safety Standards. Model Number:

Voltage Transducer UMT516 / MT516

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

GRE130. Protection and Control for MV Systems

TM251MESC controller M251 Ethernet CAN

TM221ME16RG. Main. Discrete output number. Discrete input current

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

GRT100 FEATURES APPLICATION

Features. Applications and Benefits TRC ELECTRONICS, INC

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

H-series (Rectifier Module)

For Transmission, Distribution and Machinery protection.

BF 79 81

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

TM241CE24T controller M IO transistor PNP Ethernet

Gelo LED Driver 100W, Single output RGLD100-24

Transcription:

Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation security for MV, HV and EHV bus-bars. It provides control, automation, metering, monitoring, DFR-quality fault oscillography, event logging and dynamic swing recording with advanced communications in a flexible, cost effective package. Apply the B-PRO 4000 relay for re-configurable simple bus applications, up to 6 feeders and 2 differential zones with breaker failure or 4 feeders and 1 transformer including separate transformer differential protection. Easy-to-use, intuitive setting and analysis software Up to 6 CTs can be configured as current inputs for the bus differential element, controlled by external inputs identifying breaker status IEC 61850 communication via optical ports Ethernet ports with 2 unique MAC addresses accommodate network access security needs Transformer zone with internal magnitude and phase shift compensation, eliminating requirements for external CT connections and auxiliary CTs Transformer zone with 2nd and 5th harmonic restraint algorithm improves security for energization and inrush High quality fault recording and event log 10 Year WARRANTY

Application Re-configurable simple bus applications for up to 6 feeders and 2 differential zones with breaker failure or for 4 feeders and 1transformer including separate transformer differential protection. Protection & Control 6 sets of CT inputs for differential protection (18 currents) using percentage slope characteristic for security on external faults Protection functions include IEEE devices 87B, 27, 59, 60, 81, 87T,,,,, 46/ Multiple zones of protection transformer, bus and dual bus zones Backup overcurrent and breaker failure for each input current User-defined directional control of overcurrent functions for networked lines User-configurable logic with ProLogic TM which includes 15 control logic statements 1 Setting group Features & Benefits Ease of Use Easy-to-use, install and maintain Easy to order no complex product codes User-friendly, Windows -based relay setting and record analysis software Setting software tool relay specific application On-Line setting Tool terminal emulator (VT100) Flexible programmable logic for building customized schemes with ProLogic TM statements 15 control logic statements (total of 120 statements) Reduced Installation and Operation Cost Substation automation cost includes IEC 61850 protocol to display and transfer operational data via local-area network (LAN) for local HMI and wide-area network (WAN) for remote monitoring SCADA Engineering, installation and commissioning cost IEC 61850 GOOSE messages communicate highspeed information between IEDs on the substation LAN such as transfer trips, interlocking, load-shedding and commands Product setting time 240 x 128 LCD graphical user interface provides convenient means to check/change specific settings and parameters Front panel indicators 11 user configurable LEDs, Relay Functional, IRIG-B Functional, Service Required, Test Mode, Alarm

Flexible Communications 2 rear ports, 100BASE-TX RJ-45 or 100BASE-FX 1300 nm multimode optical with ST style connector Ethernet ports with 2 unique MAC addresses that easily accommodate network access security needs Front panel USB and 100BASE-TX RJ-45 Ethernet port interfaces Substation Automation Ethernet Ready IEC 61850 Station Bus on a dedicated optical/copper Ethernet Port Enhanced DNP3 SCADA communication protocol including user-selectable point lists, class support and multiple master station support Modbus SCADA communication protocol IRIG-B port (through BNC connector) for precise time stamping and sample synchronization Serial communication port 30 virtual inputs for local and remote control Optional internal modem Multi-Functional ording and Event Logging Exceptional fault recording capabilities (with 96 samples/cycle or 5760 Hz) and dynamic swing recording (at nominal frequency) Up to 75 x 2 second transient records, or up to 150 x 120 seconds swing records, or combination of transient, swing and optional event records Metering functions for each input connection Sequence of event recorder 250 events with 1 ms resolution Compressed event record capabilities a compressed sequence of event file is created approximately every 230 events ordgraph TM and ordbase View TM Display multiple channels simultaneously and combine records Display multiple component voltage, current or summed channels Display THD, harmonic magnitude Zoom, alignment, scaling, unit functions ord summaries including event lists COMTRADE, PTI and MS Excel export

Best in Class Human-Machine Interface Large LCD display, allows for better metering display Navigation controls allow for an easy experience through settings, maintenance, service and view menus Programmable target LEDs provide tripping information to expedite response to system events New faster processor and hardware platform Rear optical ports ready for IEC 61850 Unique front panel USB and Ethernet ports provide easy and fast access to settings and set up Protection & Control Function Diagram Transformer Bus PT 27 27 59 59 60 81O 81O 81U 81U 87B 87T B-PRO

Detailed Specifications B-PRO 4000 Bus Protection Relay Item Quantity/Specs Notes General Nominal Frequency 50 or 60 Hz Operating Time 87B: 16 25 ms typical 87T: 12 24 ms typical Including relay output operation Sampling Rate 96 samples/cycle ords up to 25th harmonic Power Supply Range: 43 275 Vdc, 90 265 Vac Power Consumption: 25 35 VA (ac) 25 35 W (dc) Protection Functions IEEE Device 87B, 87T, 27, 59, 60, 81,,,,, 46/ 6 x 3-phase current inputs (18 current channels) 1 x 3-phase voltage inputs (3 voltage channels) ProLogic 15 statements/setting group 5 inputs/statement Setting Groups 1 setting group Fault protection, montoring and dynamic swing recording ording ord Capacity Up to 75 x 2 second transient records or up to 150 x 120 seconds swing records or combination of transient, swing and optionally event records with a total number of records limited to 150 Transient 96 s/c oscillography of all analog and external input digital channels Transient record length is user-configurable (range from 0.2 to 2 seconds); transient record pre-fault time is user-configurable (range from 0.10 to 0.5 seconds) Swing record length is user-configurable (range from 60 120 seconds); swing record pre-trigger time is fixed at 30 seconds Viewing software provides waveform, symmetrical components and harmonic analysis Dynamic Swing 1 sample/cycle or 60 samples/second Line positive sequence voltage, current and frequency, W Var and Z for each of the 6 feeder input. Each swing record can be up to maximum 120 seconds Events 250 events 1 ms resolution. When event auto save is enabled, a compressed event record is created is created approximately every 230 events. A/D Resolution 16 bits, 65536 counts full scale peak peak Input & Output Analog Voltage Inputs 1 set of 3-phase voltage inputs (3 voltage channels) Analog Current Inputs 6 sets of 3-phase current inputs (18 current channels) Nominal voltage Continuous rating over voltage Maximum over-scale thermal rating Thermal Rating Burden Nominal current Full scale/continuous Maximum full-scale rating Burden Vn = 69 Vrms 2x Vn = 138 Vrms 3x Vn = 207 Vrms for 10 seconds 400 Arms for 1 second <0.15 VA @ 69 Vrms In = 5 or 1 Arms 3x In = 15 or 3 Arms 40x In = 200 Arms or 40 Arms symmetrical <0.25 VA @ 5 Arms

B-PRO 4000 Bus Protection Relay Item Quantity/Specs Notes Input & Output External Inputs (digital) 9 inputs Optional 48/125/250 Vdc nominal, externally wetted Output (contacts) 14 programmable outputs and 1 relay inoperative output (N.C.) (3U model) Interface & Communication Front Display 240 x 128 pixels graphics LCD Externally wetted Make: 30 A as per IEEE C37.90 Carry: 8 A Break: 0.9 A at 125 Vdc 0.35 A at 250 Vdc Front Panel Indicators 16 LEDs: 11 programmable and 5 fixed Target, Relay Functional, IRIG-B Functional, Service Required, Test Mode, Alarm Front User Interfaces USB port and 100BASE-TX Ethernet port USB 2.0, RJ-45 Rear User Interfaces LAN Port 1: 100BASE copper or optical LAN Port 2: 100BASE copper or optical Copper: RJ-45, 100BASE-TX Optical: 100BASE-FX, Multimode, 1300 nm, ST style connector Two Serial RS32 ports to 115 kbd Com port can support an external modem Internal Modem 33.6 Kbps, V.32 bis Optional internal modem SCADA Interface DNP3 or Modbus DNP3: Ethernet or RS32, Modbus: RS32 Time Sync IRIG-B, BNC connector Modulated or unmodulated, auto-detect Self Checking/Relay Inoperative 1 contact Closed when relay inoperative Environmental Ambient Temperature Range -40 C to 85 C for 16 hours -40 C to 70 C continuous IEC 60068, 2 Humidity Up to 95% without condensation IEC 60068-30 Insulation Test (Hi-Pot) Power supply, analog inputs, external inputs, output contacts at 1.5 kv, 50/60 Hz, 1 minute IEC 60255-5, ANSI/IEEE C37.90 Electrical Fast Transient Tested to level 4 4.0 kv 2.5/5 khz on power and I/O lines IEEE C37.90.1: 4kV / IEC 6025-4 Class 3 / IEC 61000-4-4: Level 3 Oscillatory Transient Test level = 2.5 kv IEEE C37.90.1: 2.5 kv / IEC 6025: Level 3 / IEC 61000-42): Level 3 RFI Susceptibility 10 V/m modulated, 35 V/unmodulated IEEE C37.90.2:35 V/m / (IEC 6025-3/ IEC61000-4-3): Level 3 Vibration, Shock and Bump 5 g and 15 g (IEC 602551,2 / IEC60068 2-6, 27): Class 1 Conducted RF Immunity (IEC 6025-6 / IEC 61000-4-6): Level 3 Voltage Interruptions 200 ms interrupt IEC 602551 / IEC 61000-41 Physical Weight 9.55 kg 21 lbs Dimensions 13.2 cm height x 48.26 cm width x 32.8 cm depth 5.2 height x 19 width x 12.9 depth Time Sychronization and Accuracy External Time Source Sychronized using IRIG-B input (modutated or unmodulated) auto detect

B-PRO 4000 Bus Protection Relay Detailed Environmental Tests Test Description Test Level Type Test Test Points FCC Part 15 RF emissions Enclosure ports Class A: 30 1000 MHz Conducted emissions ac/s Class A: 0.15 30 MHz IEC/EN 602555 RF emissions Enclosure ports Class A: 30 1000 MHz Conducted emissions ac/s Class A: 0.15 30 MHz IEC/EN 61000-3 Power line harmonics Class D: max.1.08, 2.3, 0.43, 1.14, 0.3, 0.77, 0.23 A... for 2nd to nth harmonic N/A IEC/EN 61000-3-3 Power line fluctuations THD/ 3%; P st < 1, P lt < 0.65 N/A IEC/EN 61000-4 ESD Enclosure contact +/- 6 kv IEC/EN 6025 Enclosure air +/- 8 kv IEEE C37.90.3 ESD Enclosure contact +/- 8 kv Enclosure air +/- 15 kv IEC/EN 61000-4-3 IEC/EN 6025-3 Radiated RFI Enclosure ports 10 V/m: 80 1000 MHz IEEE C37.90.2 Radiated RFI Enclosure ports 35 V/m: 25 1000 MHz IEC/EN 61000-4-4 Burst (fast transient) Signal ports +/- 4 kv @2.5 khz IEC/EN 6025-4 +/- 4 kv IEEE C37.90.1 dc power Port +/- 4 kv Earth ground ports +/- 4 kv IEC/EN 61000-4-5 Surge Communication ports +/- 1 kv L-PE IEC/EN 6025-5 Signal ports +/- 4 kv L-PE, +/ kv L-L +/- 4 kv L-PE, +/ kv L-L +/- 2 kv L-PE, +/ kv L-L IEC/EN 61000-4-6 Induced (conducted) RFI Signal ports 10 Vrms: 0.150 80 MHz IEC/EN 6025-6 10 Vrms: 0.150 80 MHz 10 Vrms: 0.150 80 MHz Earth ground ports 10 Vrms: 0.150 80 MHz IEC/EN 6025-7 Power frequency Binary input ports: Class A Differential = 150 Vrms Common = 300 Vrms IEC/EN 61000-4-8 Magnetic field Enclosure ports 40 A/m continuous, 1000 A/m for 1 s IEC/EN 61000-41 IEC/EN 61000-49 Voltage dips & interrupts 30% for 1 period, 60% for 50 periods 100% for 5 periods, 100% for 50 periods 30% for 0.1 s, 60% for 0.1 s, 100% for 0.05 s IEC 602551 Voltage dips & interrupts 100% reduction for up to 200 ms

B-PRO 4000 Bus Protection Relay Detailed Environmental Tests Test Description Test Level Type Test Test Points IEC/EN 61000-42 Damped oscillatory Communication ports 1.0kV Common, 0 kv Diff IEC/EN 6025 Signal ports 2.5kV Common, 1 kv Diff 2.5kV Common, 1 kv Diff 2.5kV Common, 1 kv Diff IEEE C37.90.1 Oscillatory Signal ports 2.5kV Common, 0 kv Diff 2.5kV Common, 0 kv Diff 2.5kV Common, 0 kv Diff IEC/EN 61000-46 Mains frequency voltage Signal ports 30V continuous, 300V for 1s 30V continuous, 300V for 1s IEC/EN 61000-47 Ripple on dc power supply 10% NOTE: The B-PRO 4000 is available with 5 or 1 amp current input. All current specifications change accordingly. ERLPhase Power Technologies Tel: 204-477-0591 Email: info@erlphase.com The specifications and product information contained in this document are subject to change without notice. In case of inconsistencies between documents, the version at will be considered correct. (D02744R13)