PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum

Similar documents
PowerLogic Circuit Monitor Series 4000 Installation Manual (Includes Models 4000, 4250, 4000T)

PowerLogic High Density Metering System 1-Meter Enclosure

4170 POS System Installation Guide

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Product Manual. TZ Centurion Port Links. TZ Centurion Port Link 7101CL TZ Centurion Multi Port Link 7105CL

Unpacking an Epica Distribution Matrix

InView Marquee Message Display

Multi Unit Enclosed Meter

MC 11 EB-2 Power supply cabinet with external bus, AC version

InnoMedia Business VoIP ATA Models

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

PACSystems RX7i IC698CHS009/119

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone

Model BB9 RS-232 Multi-Drop Box. Operating Bulletin. Innovative Flow and Pressure Solutions. Standard 8 pin Mini-DIN Connector

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

IGLOO IGLOO EASY INSTRUCTION MANUAL

Installing the Cisco AS5400XM Universal Gateway

iconverter 2-Module Power Chassis

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

IPC194. ipconv Protocol Converter

OVEN INDUSTRIES, INC.

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

Leased-Line Extenders over IP

Power-Style QED-2, Series 2 Low Voltage Switchboards

10/100/1000TxBase-T(X) P.D. input port and two 10/100/1000TxBase-T(X) P.S.E. output ports, the device not only pass on

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Installation and Configuration Guide

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

Temperature. Power requirements. Weight. Dimensions

EA500. Installation Instructions Transponder

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

Features: Example of use

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Junos WebApp Secure 5.0 Hardware Guide

SPX-7400_SPX-7410_MAN_161028

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Specification Sheet: HT SERIES

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

SmartVFD Disconnect Panel Assemblies

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

POWERWISE INDAC SETUP MANUAL

Panoramic Power Installation and configuration guide

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

I/O SIGNAL CONDITIONER

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

Installing the Cisco ATA

IGLOO IGLOO EASY INSTRUCTION MANUAL

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

PanelView Plus/VersaView CE Terminals and Display Modules

IMAGE-BASED CODE READERS

TXM1.8RB. TX-I/O Blinds module

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Island bus expansion module

3190 Series Touch Screen POS Workstation

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

NUV300 Datasheet. Nuvation BMS Low-Voltage Battery Controller , Rev Copyright 2018, Nuvation Energy

Avanti HP Series Centrifuges Preinstallation

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

UniStream CPU-for-Panel

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Electrical Demand Specification (Reference SOP: )

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Site Preparation for ClearCube Installation. Rev. F

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Modular 8-Port Mid-span Power over Ethernet Injector

UniStream HMI Panel. CPU-for-Panel

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Aruba JL311A Cable Guard Installation Instructions

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

TRC-190 User s Manual

1 Channel Strobe Controller ORDERCODE 40226

Airflow Pressure Sensor

TRC-190 User s Manual

P522 Signal Processor

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996

INSTALLATION INSTRUCTIONS

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Generator Performance Guide 7EN /2015

ASTAT XB/XBm Remote Operator

Rack Mount Power Supplies

IN-E1004 Encoder Hardware Manual

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VM-24H 2 Input 1:4 HDMI Distributor. P/N: Rev 4

Preparing to Install the VG248

SoundwebTM. Installation Guide

Transcription:

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum Contents POWERLOGIC Circuit Monitor Series 4000T Reference Manual Addendum CONTENTS CONTENTS................................................ 1 INTRODUCTION............................................ 2 CIRCUIT MONITOR INSTALLATION............................ 2 Description............................................. 2 Dimensions............................................. 4 Mounting............................................... 5 Mounting Considerations............................... 5 1

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum 63230-300-219/A1 Introduction INTRODUCTION This instruction bulletin is an addendum to the PowerLogic Circuit Monitor Series 4000T Reference Manual (63230-300-216/A1). CIRCUIT MONITOR INSTALLATION This section describes the circuit monitor hardware, provides dimensional drawings, and explains how to mount the circuit monitor. Description Figure 1 shows the parts of the circuit monitor. A brief description of each part follows in Table 1 on page 3. 6 5 4 3 7 2 9 10 11 8 1 Figure 1: Parts of the Series 4000T Circuit Monitor 2

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum Circuit Monitor Installation Table 1: Parts of the Circuit Monitor with Transient Detection 1 2 3 4 5 6 7 8 9 10 11 Part Current/voltage module for transient detection KYZ RS-232 port (COM2) with transmit and receive LED indicators RJ-12 display comms port RS-485 port (COM1) with transmit and receive LED indicators Power LED indicator Maintenance LED indicator Access door Control power supply connector I/O Extender Option card slots Description The current and voltage connections are housed in this removable current/voltage module for transient detection (CVMT), which plugs directly into the main housing of the circuit monitor. All metering data is acquired through the CVMT. Because the CVMT is removable, it can be easily interchanged with enhanced current/voltage modules for transient detection as they become available without removing the entire circuit monitor. KYZ pulse output. The RS-232 port can be used for direct communications to the PC. The port has two corresponding LEDs. The yellow LED illuminates when the circuit monitor is receiving data (RX) across the communications; the green illuminates when data is being transmitted (TX). The RJ-12 port is used for communications and control power connections to the remote display. The RS-485 port is used for communications with daisy-chained devices. The port has two corresponding LEDs. The yellow LED illuminates when the circuit monitor is receiving data (RX) across the RS-485 communications; the green illuminates when data is being transmitted (TX). A steady-state green LED is continuously illuminated when the circuit monitor is powered up. This LED illuminates red if the circuit monitor is experiencing an internal problem and requires service. The access door provides access to a security switch that, when activated, locks setup information and metering data in the circuit monitor. This door also lets you access the memory chip for upgrading the circuit monitor s memory. Connection for control power to the circuit monitor. Optional, external field-installable I/O accessory that lets you expand the input and output capabilities of the circuit monitor. The I/O extender plugs directly into the main housing of the circuit monitor and holds up to 8 individual plug-on digital or analog I/O points. Many combinations of inputs and outputs can be configured. Standard modules are available, or you can select other combinations of inputs and outputs and field-install the pluggable I/Os. Optional cards fit in the two slots provided on the top of the circuit monitor, such as a digital I/O card (outputs rated up to 10 A) or an Ethernet communications card. 3

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum 63230-300-219/A1 Circuit Monitor Installation Dimensions 9.11 231.4 4.66 118.4 5.50 139.7 8.35 212.1 6.52 165.6.24 5.9.23 5.9 8.17 207.5 8.65 219.7 Top View.77 19.6 INCHES millimeters 3.16 80.3 3.43 87.1 4.23 107.4 4.80 121.9 5.24 133.1 0.16 4.1 End View Side View Figure 2: Circuit monitor dimensions 4

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum Circuit Monitor Installation Mounting Mounting Considerations Before mounting the circuit monitor, understand all mounting considerations described in the following section. When choosing a mounting location, consider the following points: Allow for easy access to all parts of the circuit monitor. Allow extra space for all wires, fuse disconnects, shorting blocks, accessories, or other components. Make sure to route the wires so that they do not cover the option card slots, I/O extender, current/voltage modules, or cooling vents on the circuit monitor. Refer to Figures 4 and 5 on page 6 for required clearances. For European Community (CE) compliance, see Required Protection for CE Compliance on page 37 of the CM4000 installation manual (63230-300-209). The circuit monitor can be mounted horizontally or vertically. The recommended orientation is to mount it vertically in an equipment metering compartment, making sure the control power connector is towards the top. See Figure 3 for the two correct mounting positions. End Vents Mount control power towards the top I/O Extender (IOX) Current/Voltage Module with Transient Detection (CVMT) Top Vents Option Card Slots A and B Horizontal Mounting Vertical Mounting (recommended) End Vents Figure 3: Possible ways to orient the circuit monitor 5

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum 63230-300-219/A1 Circuit Monitor Installation CAUTION IMPROPER VENTILATION Do not mount the circuit monitor to a ceiling or in vertical orientations other than the one indicated in this instruction bulletin. Provide the following clearances around the circuit monitor as illustrated in Figures 4 and 5 and Table 2: Failure to follow these instructions can result in equipment damage. B A C B D Figure 4: Clearance for vertically mounted circuit monitors NOTE: Use Table 1 on page 3 to determine clearance values. 6

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum Circuit Monitor Installation F G E F H H Figure 5: Clearance for horizontally mounted circuit monitors NOTE: Use Table 2 to determine clearance values. Table 2: Clearance values based on ambient temperature Ambient Temperature less than or equal to 50 C (122 F) greater than 50 C (122 F) Inches (millimeters) A B C D E F G H 1.5 (38) 3.0 (76) 2.5 (64) 3.0 (76) 2.0 (51) 1.5 (38) 2.0 (51) 3.0 (76) 2.5 (64) 3.0 (76) 2.0 (51) Locate the circuit monitor in an area where ambient conditions fall within the acceptable range. The circuit monitor s ambient temperature range is -20 C to +70 C when mounted vertically with one or no option cards installed and an I/O extender (IOX) with digital I/O modules installed. See Table 3 on page 8 for operating temperatures. 7

POWERLOGIC Circuit Monitor Series 4000T Reference Manual Addendum Circuit Monitor Installation Table 3: Operating temperatures Mounting Orientation Number of Options Cards Ambient Temperature Rating ➁ Vertical 0 or 1-20 C to +70 C Vertical 2 Horizontal 0 to 1-20 C to +65 C Horizontal 2-20 C to +60 C With I/O Extender (IOX) Option equipped with analog I/O modules➀ IOX-2411 (or custom IOX with up to 2 analog modules) 0 to +60 C IOX-0404 (or custom IOX with 4 analog modules) 0 to +50 C ➀ No more than four analog I/Os can be installed in the I/O Extender (IOX). Do not mount two analog modules side by side. If using two analog modules, place them at opposite ends of the extender. See the documentation that ships with the I/Os for instructions on installing I/Os. ➁ Ambient temperature refers to the immediate environment of the circuit monitor, including the temperature within the enclosure in which it is mounted. Electrical equipment should be serviced only by qualified maintenance personnel. No responsibility is assumed by Square D for any consequences arising out of the use of this material. 8