Test Procedure for the NCP1247USBPDGEVB Evaluation Board

Similar documents
EZ-PD CCG2: USB Type-C Cable Controller With PD

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

Lab Tutorial for TWR-S08GW64 TOWER SYSTEM. MC9S08GW64 LCD segment MCU for flow meters and energy metering applications

USB-PDISO8 Specifications

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

4 Connection and interface

Getting Started with InnoSwitch TM 3-Pro Code Library using Arduino

Treadmill Embedded Touch Screen Won t Power Up

CY4532 EZ-PD CCG3PA Evaluation Kit Guide

CY4531 EZ-PD CCG3 Evaluation Kit Guide. Doc. No Rev. *C. Cypress Semiconductor 198 Champion Court San Jose, CA

Contents. Please read and remember the following warnings before using the RELAYplate:

DEMO9S08SH32/SG32 Demonstration Board for Freescale MC9S08SH32/SG32

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

DEMO9S08SH8/SG8 Demonstration Board for Freescale MC9S08SH8/SG8

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

Figure 1. 6-Way JAMMA Switcher

2. Hardware Connectivity

Test Procedure for the NCV786XXAR10GEVK Evaluation Board 1.0 NCV786XX DEMO KIT VER 1: OVERVIEW...3

Drexel University Electrical and Computer Engineering Department ECE 200 Intelligent Systems Spring Lab 1. Pencilbox Logic Designer

CY4541 EZ-PD CCG4 Evaluation Kit Guide

M4-ATX-HV 6-34V Intelligent ATX Power Supply

MegaTrak MCU-9000 Harness Wiring

MouldFlo Wiring Manual

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

CY4541 EZ-PD CCG4 Evaluation Kit Guide

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

Power connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123

USER S MANUAL VER.2. C76- MULTIFUNCTION CNC BOARD Rev. 1.4

Manual 601: : USB/RS232. Specifications. Contents. Options

FOR SERVICE TECHNICIAN S USE ONLY

A brief user guide Universal Learning Remote Controller

PAD ANALOG / DIGITAL TRAINER OPERATOR S MANUAL

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

MCU-9201MT22 venetian blind controller

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

MAXREFDES24EVSYS User Manual

Pico Amiga ATX power adaptor install guide

Analog Input and Output Options for Syringe Pumps

Embedded Systems and Software

CHAPTER Wi r i n g NOTICE:

MOULDFLO WIRING MANUAL

Getting Started with InnoSwitch TM 3-Pro Code Library using PIC16F18325

Power Entry. Version 1.0 June 2, 2017

DEMO9S08LG32 Up to 5V MCU with integrated LCD display driver

Blue Point Engineering

Digital Speed Controller User Manual

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

EZ-PD CCG2 Development Kit Guide

USB INTERFACE SYSTEM DIG-703A / DIG-703B PRODUCT MANUAL. DOC-114 Rev 1.7. Copyright 2013 All Rights Reserved

Universal AC Input, 12 V0.35A Output, 4.2 Watt Non-isolated Power Supply

M2-ATX-HV 6-32V Intelligent Automotive ATX Power Supply

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter

This manual provides information for the final user application developer on how to use SPC57S-Discovery microcontroller evaluation board.

Appendix E: Edge Ti. Overview. Appendix E: Edge Ti 169

4 Connection and interface

Quick Start Guide. TWR-K70F120M High-Performance MCUs with Graphics LCD, Connectivity and Security TOWER SYSTEM

Adapter Kit - Remote QSI Electronics Installation Instructions

HVP-56F82748 Quick Start Guide

CY4502 EZ-PD CCG2 Development Kit Guide

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Blue Point Engineering

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup Using a USB Debug Adapter

STEPPER-MOTOR-RD STEPPER MOTOR REFERENCE DESIGN KIT USER S GUIDE. 1. Kit Contents. 2. Kit Overview. Figure 1. Stepper Motor Reference Design Board

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Field Service Procedure 24VDC Pedestal Power Supply Kit, Non- Braked, XX06-XX06RZ & 24VDC BUC Power Supply XX06 & XX09

Chrontel CH7251A for USB Type-C Charger

Model 7705 Control Module

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

User's Manual Rev. 1. Freescale Semiconductor Inc. TWRS08UNIVUM

Introduction to PSoC Designer 5 and PSoC Programmer

Installation Manual for D244X Series 24-volt Power Supplies

M2-ATX 6-24V Intelligent Automotive ATX Power Supply

47.1. Inductive Proximity Sensors. Contents. iprox Sensors. iprox Sensors

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter

January Bob Wright. 1 P age Bob Wright

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

Preface About this User's Guide... iv What you will learn from this user's guide... iv Conventions in this user's guide... iv

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup Using a USB Debug Adapter

Table 1. RS232 Serial Adapter DEBUG Connector Pin Descriptions

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter

Exercise 2: FACET Base Unit Familiarization

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Cookie User Manual. For NuMicro Edition 1.0. Rev. 1.0 Release: forum.coocox.org.

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

USER S MANUAL Power Supply for Backplane Vdc

FOR SERVICE TECHNICIAN S USE ONLY

Time Counters mini "h", DC Version

DPM Digital DC Power Meter with Data logging capability. User Manual

Opal Kelly. XEM3001v2 User s Manual. A business-card sized (3.5 x 2.0 ) experimentation board featuring the Xilinx Spartan 3 FPGA.

ACE-SDC-V3 Stepper Driver +Controller with USB 2.0 Communication

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838

H3G-380 Production Description

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

PN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Transcription:

Test Procedure for the NCP1247USBPDGEVB Evaluation Board How to program the cypress MCU 1. You need MiniProg3 http://www.cypress.com/documentation/development-kitsboards/cy8ckit-002-psocminiprog3-program-and-debug-kit 2. Install the PSoC Programmer included on CD or you can download the latest version on web: http://www.cypress.com/documentation/software-and-drivers/psoc-programmer-3231 3. Connect your PC with the MiniProg3 and with the Poweboard 4. Launch the PSoC Programmer 5. If everything is all right, you can see message Successfully connected to MiniProg3 version and Device se to CYPD1132-16SXI : 10/27/15 1 www.onsemi.com

6. Load file Onsemi_power_adapterv1.hex 7. Supply the powerboard from mains and you see the change on power status and voltage. Use terminal X102-1 for L, terminal X102-2 for N and terminal X102-3 for PE. If you have two wires cable as it usual, the terminal PE should be unconnected. 10/27/15 2 www.onsemi.com

8. Click on Program button. If you see the message FAILED!, just toggle the programming mode to power cycle, click on toggle power button and program button. 10/27/15 3 www.onsemi.com

9. If you see the message Programming succeeded, the program was loaded. 10/27/15 4 www.onsemi.com

How to control the output of poweboard USB-PD 1. I strongly recommend supply the CCG1 Host Board rev3 from the stable power source and not from the PC by USB Mini cable. The connector J28 is for power supply, pin1 - +5V, pin2 GND. Reconnect the jumper on connector J43 to connect the pins 1-2. 2. Prepare the USB Type-C cable. Cut the connector from one side and use the red wire for VBUS (X100-2), black wire for RTN (X100-1) and brown for CC(X100-3). Verify that you use the right wires! The schematic of CCG1 Host board rev3 is attached as a file AC- DC_w_Cypress_Host.pdf. 3. Connect these wires to X100 terminal on poweboard. 4. Now, you supply the CCG1 Host Board rev3, supply the powerboard from mains. 5. Connect the USB Type-C connector to the CCG1 Host Board. On the output of powerboard is 5V now. 6. When you press the SW2 button on CCG1 Host Board rev3, you can change the output voltage on the power board among the voltage levels 5V, 12V, 20V. There is no debounce filter on the SW2 button, so sometimes you can change the voltage from 5V to 20V. It s not a fault of powerbobard. 7. Do not supply the power board with connected CCG1 Hostboard rev3. It could lead to higher consumption of Cypress MCU. When you end the work with power supply, disconnect the USB-TypeC connector. 10/27/15 5 www.onsemi.com

X102 X100 09/23/2015 Required Equipment: Current limited 90 265 Vrms AC source (current limited to avoid board destruction in case of defective part) (e.g. KEYSIGHT 6813B).... 1pc AC Volt-Meter able to measure up to 300 V AC (e.g. KEITHLEY 2000). 1pc AC Amp-Meter able to measure up to 3 A AC (e.g. KEITHLEY 2000)... 1pc DC Amp-Meter able to measure up to 3 A DC (e.g. KEITHLEY 2000). 1pc DC Volt-Meter able to measure up to 30 V DC (e.g. KEITHLEY 2000)... 1pc DC Electronic Load (e.g. AGILENT 6060B).. 1pc DC source (e.g. STATRON 2223.1)..... 1pc AC source A 1 85-265 V rms 2 3 V ~ I IN V IN RTN VBUS NC1247 + CYPD1132 Demo board CC 1 2 3 V OUT V A I OUT USB Type-C SW2 CCG1 Host Board Rev3 1 2 J43 1 2 J28 +5V GND = DC source 5 V / 0.5 A DC load max 20 V / 3 A Figure 1: Test Setup The following steps describe the test procedure for all these boards: Test Procedure: 1. Connect the test setup as shown in Figure 1. Don t connect the CCG1 Host Board Rev3 with USB Type-C cable. 2. Apply an input voltage to NCP1247 + CYPD1132 demoboard, V IN = 90 265 Vac 3. Apply an input voltage to CCG1 host board Rev3, V IN = 5 Vdc 4. Set load current to I OUT = 0 A 5. Check that V OUT = 0 Vdc 6. Connect the USB Type-C cable to the CCG1 Host Board Rev3 7. Check that V OUT = 5 Vdc 8. Set I OUT = 3 A 9. Press the SW2 button 10. Check that V OUT = 12 Vdc 11. Press the SW2 button 12. Check that V OUT = 20 Vdc 13. Press the SW2 button 14. Check that V OUT = 5 Vdc 15. Turn off the load 16. Disconnect the USB Type-C cable to the CCG1 Host Board Rev3 17. Turn off AC source 18. Turn off DC source 10/27/15 6 www.onsemi.com

19. End of the test Test of OCP protection: 1. Connect the test setup as shown in Figure 1. Don t connect the CCG1 Host Board Rev3 with USB Type-C cable. 2. Apply an input voltage to NCP1247 + CYPD1132 demoboard, V IN = 90 265 Vac 3. Apply an input voltage to CCG1 host board Rev3, V IN = 5 Vdc 4. Set load current to I OUT = 0 A 5. Connect the USB Type-C cable to the CCG1 Host Board Rev3 6. Set the output voltage to V OUT = 20 Vdc by SW2 button 7. Set I OUT = 3 A 8. Set I OUT = 4 A and check output voltage. V OUT should be 0 Vdc. 9. Check the output voltage after few seconds. It should be 5 Vdc. 10. Turn off the load 11. Disconnect the USB Type-C cable to the CCG1 Host Board Rev3 12. Turn off AC source 13. Turn off DC source 14. End of the test Be careful when manipulating the boards in operation, lethal voltages up to 425V are present on the primary side. An isolation transformer is also recommended for safer manipulations. 10/27/15 7 www.onsemi.com