CyberRack Active Rear Door. Rack-based CW cooling for optimum operating conditions

Similar documents
AirBooster 2 and AirModulator 2

IT Cooling Solutions. STULZ AirModulator, AirBooster and AirBooster Pro. Air Flow Management for Data Centres

STULZ Custom Indoor AHU

CyberCool Indoor. Free cooling function for maximum efficiency the powerful chiller for indoor installation

CyberCool WaterTec Forward-thinking, environmentally friendly and efficient. The new water-cooled chiller by STULZ.

IT Cooling Solutions. CyberCool Indoor Data-Chiller. Targeted cooling of IT and medical equipment

CyberHandler 2 The Indirect Evaporative Free Cooling Air Handling Unit

RACK COOLING SOLUTIONS. Prodigy

CyberCool 2 The quietest, most efficient and most reliable chiller in its class. Made as required. Made in Germany.

Globally Close to You Precision Control

Präzisionsklima Komfortklima Service Anlagenbau. STULZ the natural choice. Chillers CyberCool

Air Handling Units. With Intelligence

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

LCP Hybrid Efficient performance with heat pipe technology

Liquid Cooling Package LCP Cooling Systems

L N

Drives Supported by EDGE. Connect/T/TC CNCs

Liquid Cooling Package LCP Cooling Systems

Drives Supported by EDGE

Rittal Cooling Solutions A. Tropp

Switch to Perfection

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Beckhoff short profile

Drives Supported by EDGE. Connect CNCs

Precision Cooling Mission Critical Air Handling Units

XPR300 Firmware Updates

Laserline LDM The compact class for diode laser

Rack & Enclosure Systems

DP 300 B and DP 600 B Series Power systems for telecom applications

DORMA BTS 80 BTS 75 V

Field Service Bulletin Revision 0 May 2013

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Windows 7 Starter (32 Bit) by (oldben). Install a new HP toner cartridge.

Efficiency of Data Center cooling

AC650 Series. General Purpose Inverter AC Inverters 0.25kW 110kW

E-Seminar. Voice over IP. Internet Technical Solution Seminar

Beckhoff short profi le

Format 12 HS. Stirrup bending machine. the history of innovation. Stirrup bending machine.

SMG High performance machines for plastic strapping NEW SMG 10 /15 SMG 25 / 20S / 25S SMG 50 / 55 SMG 65. SMG 65i / 75i

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Traffic Offload. Cisco 7200/Cisco 7500 APPLICATION NOTE

Edition 1.0. Made in Germany

Thermal management. Thermal management

TEMPRO Mold Temperature Controllers

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

CERTIFICATE. with the organizational units/sites as listed in the annex

IT Air Conditioning Units

Format 16 HS Format 16 HS 3D

CyrusOne Case Study About CyrusOne

X-SHARK v User guide

) ) page 04. page 07. page 10. page 10. page 12. page 14. page 14. page 16. page 18. page 19. page 19. page 20. page 21. page 22

Introducing remote I/O modules with switchable input response time specific to application requirements! Features

Remote Help for Hypertherm CNCs

Application of Green Technology For Data Centre

STULZ Digitronic software Complete control for more reliability and maximum efficiency in data centers

BSRIA Air Conditioning Worldwide Market Intelligence

Reverse Flow Cabinet. ContraFlo Cabinet. Reverse Flow Cabinet for Raised Floor Data Centers

Power Analyzer Firmware Update Utility Version Software Release Notes

Phoenix Software Demonstration for HyPrecision Waterjet. Application Note

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

robust power for data centres

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Cisco ONS SDH 12-Port STM-1 Electrical Interface Card

Total Modular Data Centre Solutions

Edition 1.0. Made in Germany

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

64.5" LCD Display Monitor

the sticker which you placed on. Hot water sets toner into fabric. 3 After side one has been printed, side one, flip the stack, and then to awaken

Reducing Data Center Cooling Costs through Airflow Containment

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

GK23A. User's Manual

RMI Temperature control

UPS5000-E (25-75 kva) Series

Sefar Screen Printing Accessories Stretching clamps, pneumatic control units and measuring devices

Voith Paper. Perfect winding technology MasterReel

Installing VISA for Remote Control

Ecotel Free Cool 5-15kW

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

2014 AT A GLANCE ASSISTING OUR CUSTOMERS IN A WORLD OF CHANGE

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

WarnerMedia. HBO Bulgaria EOOD. HBO Adria d.o.o. HBO Europe s.r.o. HBO Adria SRB Lt. Belgrade. HBO Holding Zrt. HBO Polska Sp. z.o.o.

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet

TROVIS 6600 Automation System for industrial processes

Senior citizen home repair grants. Check the printers environment; very dry (low the problem, contact an HP-authorized dealer or.

P-C Weld Twin P-C Weld Combi Weld Twin Combi Weld MRV 2 Mesh Welding Plants from coil

Guide rail holder GRUNDFOS INSTRUCTIONS. Service kit instructions. Halter für Führungsschienen. Support des barres de guidage. Supporto delle guide

ELECTRONIC CONTROL PANELS

PROMAPHON Pe Sound absorption textile material, polyurethane free, with MED certification for low flame spread, minimal smoke, rot proof and non-toxic

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

One Stop Cooling Solution. Ben Tam Business Development Manager

Verifying Effectiveness of Proprietary and Standard FEC in 40G/43G Networks

Rittal LCP T3+ High-availability IT cooling with no compromise

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

WAGO BACnet Controller. The Controller for Building Automation

E-Seminar. Wireless LAN. Internet Technical Solution Seminar

Transcription:

CyberRack Active Rear Door Rack-based CW cooling for optimum operating conditions

Efficient and targeted rack cooling The CyberRack Active Rear Door is a heat exchanger door with EC fans for installing on the rear door of server racks. Combined with a chiller, the space-saving CyberRack units remove the heat generated by the servers right at the source. No more hot air gets into the room. CyberRack units take up virtually no footprint and therefore ensure optimum use of available space in the data center. When there are high heat loads, hot spots and no raised floor, these units are the ideal solution. Service worldwide For 40 years, the STULZ service organization has provided preventive and corrective services for missioncritical applications. With 10 branches, 19 subsidiaries, and sales and service partners in more than 140 countries, we make sure we are close to our customers all over the world, ensuring perfect operation of their CyberRack systems.

Advantages at a glance Flexibility Individual adapter frames for adaptation to any rack For cooling entire IT rooms and data centers without additional CW air conditioning systems Also suitable for supplementing existing precision air conditioning units For server racks both with and without integrated fans Space-saving installation as a rack door with no changes to the data center structure Efficiency Optimum operating conditions: No mixing of server outlet air with the room air, because no hot return air gets into the room As the servers are cooled directly in the server rack, high water temperatures are possible, considerably increasing the number of operating hours with Free Cooling In combination with the STULZ CyberCool 2 including Free Cooling function, operating costs are dramatically reduced Operational reliability To protect the server's own fans from excess pressure, the optional differential pressure control from STULZ adapts the speed of the CyberRack fans in line with the server airflow The EC fans are equipped with connectors and can be replaced during operation if necessary Worldwide service Easy installation Once the rack rear door has been replaced by the adapter frame, the CyberRack can be fitted quickly and easily. The rack-specific adapter frames are available in two different heights and widths (height: 42 U and 48 U, width: 600 mm and 800 mm). Compact design Kompaktes Design Less than 300 mm additional rack depth Weniger No need als to reposition 300 mm zusätzlicher the server racks Racktiefe Keine The servers Notwendigkeit can retain die all Serverracks the height units umzupositionieren in the rack Die Fläche im Serverrack wird weiterhin ausschließlich für Server genutzt.

Application 1: Autonomous CW cooling CyberRack units, in combination with a chiller, deliver the necessary cooling capacity for the entire IT room Reliable cooling even without a raised floor No hot return air in the IT room No need to separate hot and cold aisles Application 2: Supplementing the precision air conditioning Targeted cooling of high-density racks For preventing hot spots No discharge of hot return air in the IT room The rear door of the server rack is replaced by the CyberRack Active Rear Door. With the aid of the integrated heat exchanger, the unit cools your servers right there where the heat is produced, without discharging return air into the room. The IT room therefore has no additional heat at all. The sensors in the CyberRack measure the return and supply air temperatures in the server rack, to ensure optimum cooling. The temperatures are adapted to the heat load of the servers, and guarantee efficient cooling whatever the server load. Integration with CyberCool 2 Solutions from STULZ are perfectly coordinated to work together, to cool your IT systems efficiently and reliably. CyberRack units work most efficiently in combination with the CyberCool 2 chiller. Investing in the quality, reliability and efficiency of STULZ air conditioning and chiller solutions pays off during operation after just a short time, due to energy savings and operational reliability. You can find more information on the CyberCool 2 on our product page at https://www.stulz.de/en/ cybercool-2/ Cyber Rack Cyber Rack Cyber Rack

C2020 controller The CyberRack units are ideal for integration in existing systems and can be controlled to perfection by the STULZ controller. Precise control based on cooling needs Continuous monitoring of fan speed, server and CyberRack outlet temperature Direct connection to BMS systems via ModBus RTU protocol or Ethernet Features EC fans for low electricity consumption For data centers with and without raised floor Maintenance-friendly Options Differential pressure control protects the server's own fans from excess pressure 2 or 3-way CW valves, also available as a 2-way pressure independent control valve Air temperature and humidity sensor Flexible connection hoses Cooling capacity display Optional pressure independent control valve (PICV) The PICV combines the functions of control, hydraulic compensation and flowrate measurement. The water flowrate required for cooling is set directly by the CyberRack control system. Low water-side pressure drops cut pump energy costs Automatic hydraulic compensation means lower investment and installation costs and faster start-up The defined water flowrate ensures stable and precise control in all load states The cooling capacity of each individual server rack is recorded Technical data Model RBW B0 RBW C0 Cooling capacity 1 kw 18.8 32.3 Airflow m 3 /h 4,800 6,000 Power consumption kw 0.6 0.80 Number of fans 2 4 5 Dimensions mm 2000 x 600 x 330 Weight kg 97 100 Power supply V/ph/Hz 230/1/50-60 1) Air inlet temperature: 40 C; r.h. 20 % Water temperature: supply 14 C, return 19 C 2) External static fan pressure: 30 Pa

STULZ Company Headquarters STULZ GmbH Holsteiner Chaussee 283 22457 Hamburg Tel. +49 40 5585-0 Fax +49 40 5585-352 products@stulz.de STULZ Subsidiaries GERMANY AUSTRALIA AUSTRIA BELGIUM BRAZIL CHINA FRANCE INDIA INDONESIA ITALY MEXICO NETHERLANDS NEW ZEALAND POLAND SINGAPORE SOUTH AFRICA SPAIN UNITED KINGDOM USA STULZ Australia Pty. Ltd. 34 Bearing Road Seven Hills NSW 21 47 Tel. +61 (2) 96 74 47 00 Fax +61 (2) 96 74 67 22 sales@stulz.com.au STULZ Austria GmbH Industriezentrum NÖ SÜD, Straße 15, Objekt 77, Stg. 4, Top 7 2355 Wiener Neudorf Tel. +43 1 615 99 81-0 Fax +43 1 615 99 81-80 info@stulz.at STULZ Belgium BVBA Tervurenlaan 34 1040 Brussels Tel. +32 (470) 29 20 20 info@stulz.be STULZ Brasil Ar Condicionado Ltda. Rua Cancioneiro de Évora, 140 Bairro - Santo Amaro São Paulo-SP, CEP 04708-010 Tel. +55 11 4163 4989 Fax +55 11 2389 6620 comercial@stulzbrasil.com.br STULZ Air Technology and Services Shanghai Co., Ltd. Room 406, Building 5 457 North Shanxi Road Shanghai 200040 Tel: + 86 21 3360 7101 Fax: + 86 21 3360 7138 info@stulz.cn STULZ France S. A. R. L. 107, Chemin de Ronde 78290 Croissy-sur-Seine Tel. +33 (1) 34 80 47 70 Fax +33 (1) 34 80 47 79 info@stulz.fr STULZ-CHSPL (India) Pvt. Ltd. 006, Jagruti Industrial Estate Mogul Lane, Mahim Mumbai - 400 016 Tel. +91 (22) 56 66 94 46 Fax +91 (22) 56 66 94 48 info@stulz.in PT STULZ Air Technology Indonesia Kebayoran Square blok KQ unit A-01 Jalan Boulevard Bintaro Jaya, Bintaro Sektor 7, Tangerang Selatan 15229 Tel. +62 21 2221 3982 Fax +62 21 2221 3984 info@stulz.id STULZ S.p.A. Via Torricelli, 3 37067 Valeggio sul Mincio (VR) Tel. +39 (045) 633 16 00 Fax +39 (045) 633 16 35 info@stulz.it STULZ México S.A. de C.V. Avda. Santa Fe No. 170 Oficina 2-2-08, German Centre Delegación Alvaro Obregon MX- 01210 México Distrito Federal Tel. +52 (55) 52 92 85 96 Fax +52 (55) 52 54 02 57 ventas@stulz.com.mx STULZ GROEP B. V. Postbus 75 180 AB Amstelveen Tel. +31 (20) 54 51 111 Fax +31 (20) 64 58 764 stulz@stulz.nl STULZ New Zealand Ltd. Unit O, 20 Cain Road Penrose, Auckland 1061 Tel. +64 (9) 360 32 32 Fax +64 (9) 360 21 80 sales@stulz.co.nz STULZ Polska SP. Z O.O. Budynek Mistral. Al. Jerozolimskie 162 02 342 Warszawa Tel. +48 (22) 883 30 80 Fax +48 (22) 824 26 78 info@stulz.pl STULZ South Africa Pty. Ltd. Unit 3, Jan Smuts Business Park Jet Park, Boksburg Gauteng, South Africa Tel. +27 (0) 11 397 2363 Fax +27 (0) 11 397 3945 aftersales@stulz.co.za STULZ España S.A. Avenida de los Castillos 1034 28918 Leganés (Madrid) Tel. +34 (91) 517 83 20 Fax +34 (91) 517 83 21 info@stulz.es STULZ Singapore Pte Ltd. 1 Harvey Road #04-00 Tan Heng Lee Building Singapore 369610 Tel. +65 6749 2738 Fax +65 6749 2750 sales@stulz.sg STULZ U. K. Ltd. First Quarter, Blenheim Rd. Epsom Surrey KT 19 9 QN Tel. +44 (1372) 74 96 66 Fax +44 (1372) 73 94 44 sales@stulz.co.uk STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 1572 Tilco Drive Frederick, MD 21704 Tel. +1 (301) 620 20 33 Fax +1 (301) 662 54 87 info@stulz-ats.com Technical data subject to change without notice. 1100424 V1.0 02-17 en STULZ GmbH, Hamburg Close to you around the world With specialist, competent partners in ten German branches and in subsidiaries and exclusive sales and service agents around the world. Our ten production sites are situated in Europe, North America and Asia. For further information, please visit our website at www.stulz.com You can find out more on our product page.