ES-362U PRESETTABLE MASTER TIMER

Similar documents
ES-562/564U COMBINATION CLOCK/TIMER

Sierra Radio Systems. HamStack. Project Board Reference Manual V1.0

Sierra Radio Systems. Digital Compass. Reference Manual. Version 1.0

GLiPIC Ver C Assembly manual Ver 1.0

SRI-02 Speech Recognition Interface

K191 3 Channel RGB LED Controller

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

DEV-1 HamStack Development Board

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

Universal Keying Adapter 3+

A Programmer for the 68HC705C8 MicroController Figure 1 PROG05 As Built PROG05 User Guide Version C1 Page 1 of 14

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Western Washington University. Electrical Engineering Technology. Etec 471. Professor Morton. Senior Hardware Description. Automated Aquarium

Storage Card Interface Kit

Installation/assembly manual for DCC/Power shield

solutions for teaching and learning

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

Pacific Antenna Easy TR Switch Kit

Rapid28iXL PIC Prototyping PCB User Manual

KDR00101 DMX Controlled Relay Kit

Temperature Measurement

Rapid40iXL PIC Prototyping PCB User Manual

BG2E Universal Gate Drive Prototype Board

RKP08 Component List and Instructions

KDR00301 DMX Controlled Relay Kit

MAINTENANCE MANUAL RF MODULE TEST FIXTURE. ericssonz LBI-38805A GENERAL TABLE OF CONTENTS STATIC HANDLING PRECAUTIONS

Assembly Instructions (8/14/2014) Your kit should contain the following items. If you find a part missing, please contact NeoLoch for a replacement.

KDS Channel DMX Controlled Servo Kit

CV Arpeggiator Rev 2 Build Documentation.

GL116 ENCODER/DECODER MANUAL GLOLAB CORPORATION

KK1L 2x6 Antenna Switch Relay Controller / Dual Band Decoder Basic Assembly Version 4.8 (new 24-Aug-2009) Parts List updated 19-AUG-2016

QUASAR KIT No DIGITAL DOWN TIMER 99 MIN WITH PIC

VG-305A AC Traffic Light Controller Kit

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Single Phase Systems-North American PC125/PC420 Series

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

NETRONICS HS3500 CONTROLLER

solutions for teaching and learning

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

Blue Point Engineering

IC-I AND IC-I F GENERAL DESCRIPTION SPECIFICATIONS. Output Impedance: Phones: 60 ohms (Unit is designed for use with ohm phones.

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Home Security System with Remote Home Automation Control

Installation & Operation Guide

TRAKIT-25P. Printings. Version 1.00: 10/03/01 Version 2.00: 01/20/03 Version 2.10: 01/19/04

DIY KIT 123. ATMEL 89xxxx PROGRAMMER

Manual Main PCB Small-MIDI 4

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

Images Scientific OWI Robotic Arm Interface Kit (PC serial) Article

Agilent 84904, 6, 7K/L Programmable Step Attenuators

High Power (15W + 15W) Stereo Amplifier

Storage Card Interface Kit

Exclusive 2.5 GHz Frequency Counter

Rapid40i PIC Prototyping PCB User Manual

Sierra Radio Systems. Making a Keyer with the. HamStack. Project Platform

Series CCR-59S/CR-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

DSP240-LPI Inverter Controller Card. Technical Brief

1

GENERAL DESCRIPTION SPECIFICATIONS. output Impedance: Phones: 60 ohms (Designed for use with ohm phones.)

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

solutions for teaching and learning

BASIC Stamp Activity Board: Features and Specifications

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

K8099 NIXIE CLOCK. * optional enclosure TKOK19 (black) - TKOK17 (white) ** optional plexiglass enlcosure B8099 ILLUSTRATED ASSEMBLY MANUAL

SPDT up to 50 GHz Pc Board - SMA - SMA mm - QMA - SMC - SMB - mini SMB - DIN 1.6/5.6 R Actuator Voltage: 2: 12 Vdc 3: 28 Vdc

RC-210 Repeater Controller Assembly Manual

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

E3B USER'S GUIDE. for QT310 / QT320 QProx IC evaluation and development Overview. Fast Start

Surge Protection for Surveillance Systems

RC210 Repeater Controller Assembly Manual

Schematic Diagram: R2,R3,R4,R7 are ¼ Watt; R5,R6 are 220 Ohm ½ Watt (or two 470 Ohm ¼ Watt in parallel)

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

PLATINUM SERIES R PART NUMBER SELECTION. High performance SPDT up to 40 GHz. Our Most Important Connection is with You. SMA - SMA 2.

DSP Filter System. Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, Doc Number: AIGO-009

Transcendent Frequency Counter

ADDJOG User Guide 7/30/10. Overview

Three Phase Systems-International PC302-I/MTD

N8VEM S-100 BACKPLANE VERSION 04 MAY 3, 2015 J.B.

Cumbria Designs T-1. C-1 Controller. User Manual

Resolver to Digital Expansion Board

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Instruction Manual for BE-SP3 Circuit. 10/21/07

Model 7705 Control Module

C S Technology Ltd. cstech.co.uk. DTMF display 32 kit with 2 line x 16 LCD display

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Photoelectric Sensors E3F2

LCMM024: DRV8825 Stepper Motor Driver Carrier,

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

MK5 5-Axis Controller

DMX CONTROLLED RELAY K8072

PedalSync. 9 Switches MV-62. Chip. Module. and

Display Real Time Clock (RTC) On LCD. Version 1.2. Aug Cytron Technologies Sdn. Bhd.

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Transcription:

142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com ES-362U PRESETTABLE MASTER TIMER OPERATION AND MAINTENANCE MANUAL The ES-362U is a four digit, presettable 100 minute master timer (00:00-99:59) with five top-front mounted controls (UP, DOWN, STOP, RESET and PRESET). Pressing the appropriate switch actuates each of the controls. The timer runs continuously unless stopped (except in the case of options X and Z, where it stops at 00:00). If stopped, the timer holds the time displayed when it was stopped. Pressing the "UP" switch starts the timer counting up from the time on the display; the "DOWN" switch starts the timer counting down from the time on the display. The "STOP" switch stops the timer count while the "RESET" switch returns the display to 00:00. The "PRESET" switch presets the timer to the time set on the front-mounted 4-digit thumbwheel switch. The timer may be reset or preset while it is stopped or while it is running. If the reset or preset switch is pressed while the timer is running, the timer does not count until the switch is released. All displays are 0.56 yellow LED digits. The ES-362U may be remotely controlled via the rear-mounted 9-pin connector (pin designations are given below). A momentary short to ground or a 5 volt logic "0" is required to actuate the desired UP, DOWN, STOP, RESET or PRESET function. A remote input should be held low for at least 25 milliseconds to insure that it will be recognized. The 9-pin connector also provides access to the option Y and Z relay contacts. An ESE Serial Time Code output of the displayed timer data is accessible on the rear-mounted BNC connector. This output is capable of driving up to 100 Remote Displays (such as the ES-372U, ES-361U, LX-361U, ES-366U, LX- 366U, ES-364U or ES-369U) through up to 4000' of coaxial cable or twisted pair. ELECTRICAL: MECHANICAL: SPECIFICATIONS Input Voltage 117 VAC, 50/60 Hz; Power Requirement 5W Max. Etched Aluminum case 2.5" High x 10" Wide x 6" Deep CIRCUIT DESCRIPTION The ES-362U is based on a single microprocessor chip, timer IC, Z4. It is powered by a +5 volt DC supply consisting of T1, diodes D1-D3, capacitors C1-C6 and regulator Z2. T1 provides 6 VAC to the voltage doubler circuit composed of D1-D2, C1-C4. Approximately +12 to +15 volts DC is developed across C1 and C3, which is regulated to 5 volts by Z2. This is used to power the timer logic. A separate 6 VDC supply is used to supply the segment driver chip Z6. IC Z4 provides all timing and control functions and generates serial control signals for the display driver chips, Z6 and Z7. The display operates in multiplex mode. Z6 and Z7 receive segment and digit drive data from Z4 via a data line (Z4 pin 28), a clock line (Z4 pin 27) and a strobe line (Z4 pin 26). A 50 or 60 Hz clock signal is taken from T1, logiclevel converted by Q1 and used for the counting timebase. Z4 also provides the Serial Timer Code, which is buffered by IC Z3. ES-362U CONNECTOR DESIGNATIONS DB-9 Pin Function 1 Up 2 Stop 3 Reset 4 Down 5 Preset 6 Relay Contact (Optional) 7 Relay Contact (Optional) 8 Not Used 9 Ground Page 1 of 8

OPTIONS Page 2 C: When this option Crystal Timebase is specified, a trimmer capacitor is included for greater accuracy. The crystal (.002% accuracy) is factory calibrated to provide an accuracy of 2-3 seconds per week and can also be field adjusted for greater accuracy. D: When this option is specified, a standard 6' remote cable that attaches to a rear-mounted 25-Pin connector is provided. All function controls (UP, DOWN, STOP, RESET and PRESET) and thumbwheel switches are mounted on a 1/8" clear anodized aluminum switch plate. With this option, the unit is housed in an etched aluminum case 2.5" High x 8" Wide x 6" Deep. Extra cable length is available upon request. J: When this option is specified, input voltage is 220 VAC, 50/60Hz. N: When this option is specified, a change in count direction occurs when the Down count reaches zero. P: When this option is specified, the unit is housed in an etched aluminum rackmount enclosure 1.75 high x 19 wide x 10 deep. P2: When this option is specified, a 19 rackmount panel allows any two units with a P2 option to be mounted side by side. Option D is required. Q: When this option is specified, the unit is housed in a console mount enclosure with an etched aluminum front panel 3.5 high x 9 wide x 8 deep. Option D is required. T: When this option (Tenths of Seconds display) is specified, a tenths digit is included to the right of seconds, with decimal point. The tenths digit is returned to zero when the reset switch is pressed. UL: When this option is specified, the unit is supplied with a UL approved wall mount power supply. W: When this option is specified, the unit is supplied with a three-wire line cord. X: This option has been optimized for timing and controlling individuals who are engaged in public speaking. Typically, as a speaker timer, the unit is operated in a countdown mode. The timer counts until it reaches 00:00, when it automatically stops. When the PRESET switch is pressed while holding down the STOP switch the thumbwheel setting is instead loaded to a special memory, called the yellow time memory, to be described below. Normally, during operation, the thumbwheel is left set to the main timer preset time so that the timer may be easily preset to the beginning of the cycle. The ES-362UX provides three isolated relay outputs that may be used for controlling different colored lamps. These are identified as the GREEN, YELLOW and RED outputs. The GREEN output contacts close when the DOWN switch is pressed, signaling the speaker to begin talking. When the timer reaches the time set in the yellow time memory the GREEN output opens and the YELLOW output contacts close, signaling the speaker to begin summing up. By default, the yellow time is 00:30 (thirty seconds remaining) unless set otherwise as described above. When the timer reaches 00:00, the YELLOW output opens, and the RED output closes, signaling the speaker that his time is up. The timer may then be preset to the beginning of the cycle in preparation for the next speaker. The outputs remain in their present state (red lamp on) until the DOWN switch is again pressed. A 25-pin connector provides access to the relay outputs (pin designations are given on page 3). The relay contacts are rated at 10 watts maximum resistive load, 500 ma maximum switching current, 30 volts maximum. When using incandescent (filament) lamps, care should be taken to operate well under these ratings, as there is a large current surge when the lamp is energized. Using a larger buffer relay with an external DC supply is recommended for driving higher powered lamps; the coil of such a relay should have a spike suppression diode connected across it. LEDs, suitably current-limited with a resistor, are easily driven by the ES-362UX relays up to the stated rating. Y: When this option (relay closure output) is specified, a relay closure with a duration of 1 second (100 milliseconds for option "T") occurs when the timer completes a countdown to zero. The relay contacts are rated at 10 watts maximum resistive load, 500 ma maximum switching current. Z: When the option (Relay contact closure and stop at zero) is specified, the timer will stop and a reed relay contact closure output occurs when the timer completes a countdown to zero. The contacts remain closed until the timer is restarted. The relay contacts are rated at 10 watts maximum resistive load, 500 ma maximum switching current.

FRONT AND REAR VIEWS Page 3 UP DOWN STOP RESET PRESET 00 00 0 0 0 0 ES-362UD AND ES-362UX When option D is ordered, the DB-9 connector is replaced with a DB-25 connector. If options Y or Z are specified, access to the relay contacts is found on pins 6 and 7 of the DB-9 connector. When option X is ordered, a DB-25 connector is provided for the three relay closures. The pin designations are shown below. D PLATE CONNECTOR DESIGNATIONS Pin Function Pin Function 1 T1 13 T1 2 T2 14 T2 3 T4 Seconds 15 T4 10 Minutes 4 T8 16 T8 5 T1 17 UP 6 T2 18 DOWN 7 T4 10 Seconds 19 STOP Control 8 T8 20 RESET 21 PRESET 9 T1 10 T2 22 Seconds Common 11 T4 Minutes 23 Minutes Common 12 T8 24 Ground (Control Common) 25 Not Used DB-25 (Option X only) Pin Function Pin Function 1 Green Relay Contact 6 Not Used 2 Green Relay Contact 7 Red Relay Contact 3 Not Used 8 Red Relay Contact 4 Yellow Relay Contact 9-25 Not Used 5 Yellow Relay Contact

Page 4 ES-362U PARTS LIST PCB COMPONENTS QTY DESIGNATION DESCRIPTION PART NUMBER 1 Z2 INTEGRATED CIRCUIT LM330T-5.0 1 Z3 INTEGRATED CIRCUIT 4503 1 Z4 INTEGRATED CIRCUIT P87C51SBPN-CT5 1 Z6 INTEGRATED CIRCUIT UCN5895A 1 Z7 INTEGRATED CIRCUIT UCN5841A 1 X1 CRYSTAL 11.0592MHZ 1 Q1 TRANSISTOR PN2222 3 D1 - D3 DIODE 1N4003 16 D5 - D20 DIODE 1N4148 or 1N914 1 R8 RESISTOR 27 OHM 1/4W 7 R22 - R28 RESISTOR 47 OHM 1/4 W 1 R29 RESISTOR 68 OHM 1/4 W 5 R17 - R21 RESISTOR 1K 1/4 W 8 R30 - R37 RESISTOR 10K 1/4 W 1 R6 RESISTOR 51K 1/4 W 1 R5 RESISTOR 120K 1/4 W 1 C10 CERAMIC CAPACITOR 10pf 50v Cer K 1 C11 CERAMIC CAPACITOR 25pf 50v Cer K 1 C8 CERAMIC CAPACITOR.01uf 50v Cer Z 2 C5, C7 CERAMIC CAPACITOR.1uf 50v Cer Z 1 C12 ELECTROLYTIC CAPACITOR 4.7uf 10v R El 1 C6 ELECTROLYTIC CAPACITOR 100uf 25v R El 4 C1 - C4 ELECTROLYTIC CAPACITOR 3300 UF 25V 2 SOCKET 16 PIN DIP SOCKET 1 SOCKET 18 PIN DIP SOCKET 1 SOCKET 40 PIN DIP SOCKET 2 N1 - N2 LED DISPLAY LTD6840Y 1 PCB UCT2 DISPLAY 1 PCB UCT-2 LOGIC CHASSIS COMPONENTS QTY DESIGNATION DESCRIPTION PART NUMBER 4 THUMBWHEEL SWITCH THUMBWHEEL SWITCH 1 END PLATE LEFT END PLATE 1 END PLATE RIGHT END PLATE 1 LINE CORD 2 WIRE LINE CORD 1 BUSHING 2 WIRE BUSHING 5 SWITCH #44 CREAM PB SWITCH 1 CONNECTOR BNC (UG-1094) 1 CONNECTOR 9 PIN MALE D-SUB 1 CONNECTOR 9 PIN FEMALE D-SUB 1 CONNECTOR 9 PIN D-SUB HOOD 1 T1 TRANSFORMER P6134 1 CASE & HARDWARE ES-362U

Page 5 ES-362U PARTS LIST (CONTINUED) OPTIONAL COMPONENTS QTY DESIGNATION DESCRIPTION PART NUMBER 1 C9 (C) VARIABLE CAPACITOR 5-30 PF TRIMM 5MM V 1 (D) CONNECTOR 25 PIN MALE D-SUB 1 (D) CONNECTOR 25 PIN FEMALE D-SUB 1 (D) CONNECTOR 25 PIN D-SUB HOOD 1 T1 (J) TRANSFORMER SSA6-6.3/230 2 T1, T2 (LX) TRANSFORMER P6465 2 T1, T2 (J AND LX) TRANSFORMER P8705/SSA5-6.3/230 1 (LX) AC SOCKET AC SOCKET (IEC 300) 1 (LX) LINE CORD/PLUG 3 WIRE CORD/PLUG 2 T1, T2 (P) TRANSFORMER P6465 2 T1, T2 (J AND P) TRANSFORMER P8705/SSA5-6.3/230 1 N3 (T) LED DISPLAY LTD6840Y 1 (UL) POWER PLUG UL PWR PLUG 1 T1 (UL) TRANSFORMER AA-061A5-206 "UL" 1 (W) LINE CORD 3 WIRE LINE CORD 1 (W) BUSHING 3 WIRE BUSHING 3 Q2 - Q4 (X) TRANSISTOR 2N2907 or PN2907 3 D4, D21, D22 (X) DIODE 1N4003 3 R7, R38, R39 (X) RESISTOR 5.1K 1/4 W 3 K1 - K3 (X) RELAY 1A5A RELAY 1 (X) PCB ES-1424M DUAL RELAY 1 (X) CONNECTOR 25 PIN MALE D-SUB 1 (X) CONNECTOR 25 PIN FEMALE D-SUB 1 (X) CONNECTOR 25 PIN D-SUB HOOD 1 Q2 (Y AND Z) TRANSISTOR 2N2907 or PN2907 1 D4 (Y AND Z) DIODE 1N4003 1 R7 (Y AND Z) RESISTOR 5.1K 1/4 W 1 K1 (Y AND Z) RELAY 1A5A RELAY IF COMPONENT REMOVAL IS REQUIRED, WE RECOMMEND REMOVING ALL SOLDER USING A 35W OR SMALLER SOLDERING IRON AND SOLDER WICK TO PREVENT DAMAGE TO THE PRINTED CIRCUIT BOARD. ALL INFORMATION CONTAINED IN THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

This page is not available with online manual requests and was intentionally left blank.

This page is not available with online manual requests and was intentionally left blank.

This page is not available with online manual requests and was intentionally left blank.